首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Yinhuan Li  Weifen Niu 《Talanta》2007,71(3):1124-1129
A flow injection chemiluminescence method was described for the determination of four phenothiazine drugs, namely, chlorpromazine hydrochloride, perphenazine hydrochloride, fluphenazine hydrochloride and thioridazine hydrochloride. Strong Chemiluminescence (CL) signal was produced when above-mentioned drug was injected into the mixed stream of luminol with KMnO4. The linear ranges of the method were 0.0020-1.0 μg/mL chlorpromazine hydrochloride, 0.0040-3.0 μg/mL perphenazine hydrochloride, 0.0020-5.0 μg/mL fluphenazine hydrochloride and 0.0050-1.0 μg/mL thioridazine hydrochloride. The detection limits were 0.4 ng/mL chlorpromazine hydrochloride, 0.7 ng/mL perphenazine hydrochloride, 2 ng/mL fluphenazine hydrochloride and 0.7 ng/mL thioridazine hydrochloride. The proposed method was applied to the determination of chlorpromazine hydrochloride in injections and in mental patient's urine samples and the satisfactory results were achieved. The possible CL reaction mechanism was also discussed briefly.  相似文献   

2.
Xu X  Su R  Zhao X  Liu Z  Li D  Li X  Zhang H  Wang Z 《Talanta》2011,85(5):2632-2638
A simple method based on simultaneous microwave-assisted derivatization and ionic liquid-based dispersive liquid-liquid microextraction (IL-based DLLME) is proposed for the derivatization, extraction and preconcentration of formaldehyde in beverage samples prior to the determination by high-performance liquid chromatography (HPLC). Formaldehyde was in situ derivatized with 2,4-dinitrophenylhydrazine (DNPH) and simultaneously extracted and preconcentrated by using microwave-assisted derivatization and IL-based DLLME in a single step. Several experimental parameters, including type and volume of extraction solvent, type and volume of disperser, microwave power and irradiation time, volume of DNPH, pH of sample solution, and ionic strength were evaluated. When the microwave power was 120 W, formaldehyde could be derivatized and extracted simultaneously only within 90 s. Under optimal experimental conditions, good linearity was observed in the range of 0.5-50 ng/mL with the correlation coefficient of 0.9965, and the limit of detection was 0.12 ng/mL. The proposed method was applied to the analysis of different beverage samples, and the recoveries of formaldehyde obtained were in the range of 84.9-95.1% with the relative standard deviations lower than 8.4%. The results showed that the proposed method was a rapid, convenient and feasible method for the determination of formaldehyde in beverage samples.  相似文献   

3.
Ming-Chi Wei 《Talanta》2007,72(4):1269-1274
The novel pretreatment technique, microwave-assisted heating coupled to headspace solid-phase microextraction (MA-HS-SPME) has been studied for one-step in situ sample preparation for polycyclic aromatic hydrocarbons (PAHs) in aqueous samples before gas chromatography/flame ionization detection (GC/FID). The PAHs evaporated into headspace with the water by microwave irradiation, and absorbed directly on a SPME fiber in the headspace. After being desorbed from the SPME fiber in the GC injection port, PAHs were analyzed by GC/FID. Parameters affecting extraction efficiency, such as SPME fiber coating, adsorption temperature, microwave power and irradiation time, and desorption conditions were investigated.Experimental results indicated that extraction of 20 mL aqueous sample containing PAHs at optional pH, by microwave irradiation with effective power 145 W for 30 min (the same as the extraction time), and collection with a 65 μm PDMS/DVB fiber at 20 °C circular cooling water to control sampling temperature, resulted in the best extraction efficiency. Optimum desorption of PAHs from the SPME fiber in the GC hot injection port was achieved at 290 °C for 5 min. The method was developed using spiked water sample such as field water with a range of 0.1-200 μg/L PAHs. Detection limits varied from 0.03 to 1.0 μg/L for different PAHs based on S/N = 3 and the relative standard deviations for repeatability were <13%. A real sample was collected from the scrubber water of an incineration system. PAHs of two to three rings were measured with concentrations varied from 0.35 to 7.53 μg/L. Recovery was more than 88% and R.S.D. was less than 17%. The proposed method is a simple, rapid, and organic solvent-free procedure for determination of PAHs in wastewater.  相似文献   

4.
A simple and sensitive spectrophotometric flow method for determination of low concentrations of the flotation collector O-ethyldithiocarbonate (ethyl xanthate, CH3CH2-O-CS2) in solutions is described. The method is based on ethyl xanthate detection at 301 nm in medium of NaOH 50 mmol L−1. By injection of 200 μL of sample, the analytical method shows linear response for the ethyl xanthate concentration from 0.5 up to 500 μmol L−1. Successive injections of 4 μmol L−1 ethyl xanthate (n = 23) show a coefficient of variation lower than 0.6%, denoting high repeatability. The detection limit is 0.3 μmol L−1. At a flow rate of 2.0 mL min−1, a frequency of 120 injections/h of ethyl xanthate can be attained. By introduction of a tangential dialysis cell in the FIA system, the manual sample filtration step with 0.22 μm filter was eliminated and the residual interference of suspended material, was completely overcome even for unfiltered sludge suspension samples, an important advantage that compensates for the frequency reduction to 25 injections/h elevation and detection limit elevation to 2 μmol L−1, still outreaching for many applications. Potential applications of the method embrace the at line determination of ethyl xanthate in the ore processing industry, control of the concentration at its optimal level during the flotation process, as well as monitoring of residues in the effluents.  相似文献   

5.
We performed the quantification of phosphorus in deoxynucleotides using capillary electrophoresis (CE) and micro-HPLC (μHPLC) hyphenated with inductively coupled plasma mass spectrometry (ICP-MS). DNA and its component units have conventionally been determined by photometry; however, more selective and sensitive methods are needed for small biological samples. CE and μHPLC offer the advantages of good separation and small consumption of samples, and ICP-MS is a highly sensitive technique for the determination of a chemical element. Therefore, we have developed an interface device for combining CE and μHPLC with ICP-MS for quantifying nucleotides based on phosphorus content. The interface utilizes 4.5 μL/min for nebulizing and effective introduction of the sample into ICP. The samples of nucleotides and free phosphoric acid were well separated in the CE–ICP-MS measurement, and the calibration curves (1–100 μg/mL) of the nucleotides showed a linear (R2 > 0.999) increase in intensity. Similarly, the samples of nucleotides were baseline separated using μHPLC–ICP-MS, and the calibration curves of the nucleotides were linear (R2 > 0.998). The detection limits of these species and phosphorus in nucleotides using CE–ICP-MS and μHPLC–ICP-MS were 0.77–6.5 ng/mL and 4.0–6.5 ng/mL, respectively. These values were about one or two orders lower than those in a previous report. The sample volumes of these experiments were calculated to be about 10 nL and 50 nL per analysis. Therefore, these analytical methods have the potential to be useful for the determination of biological samples, such as DNA and RNA molecules.  相似文献   

6.
This work assesses the potential of a new adsorptive material, Amberlyst 36, for the separation and preconcentration of trace manganese(II) from various media. It is based on the sorption of manganese(II) ions onto a column filled with Amberlyst 36 cation exchange resin, followed by the elution with 5 mL of 3 mol/L nitric acid and determination by flame atomic absorption spectrometry (FAAS) without interference of the matrix. Different factors including pH of sample solution, sample volume, amount of resin, flow rate of sample solution, volume and concentration of eluent, and matrix effects for preconcentration were investigated. Good relative standard deviation (3%) and high recovery (>95%) at 100 μg/L and high enrichment factor (200) and low analytical detection limit (0.245 μg/L) were obtained. The adsorption equilibrium was described well by the Langmuir isotherm model with maximum adsorption capacity of 88 mg/g of manganese on the resin. The method was applied for the manganese determination by FAAS in tap water, commercial natural drinking water, commercial treated drinking water and commercial tea bag sample. The accuracy of the method is confirmed by analyzing the certified reference material (tea leaves GBW 07605). The results demonstrated good agreement with the certified values.  相似文献   

7.
Based on the enhancement of chemiluminescence (CL) of luminol-hydrogen peroxide-gold nanoparticles system by fluoroquinolones (FQs), a novel and rapid CL method is reported for the determination of FQs derivatives. Under the optimum conditions, the CL intensity is proportional to the concentration of FQs derivative in solution. The corresponding linear regression equations are established over the range of 0.08-1.28 μg/mL for norfloxacin, 0.013-1.32 μg/mL for ciprofloxacin, 0.014-1.4 μg/mL for lomefloxacin, 0.029-1.46 μg/mL for fleroxacin, 0.02-1.0 μg/mL for ofloxacin and 0.01-1.44 μg/mL for levofloxacin, respectively. The limits of detection (S/N = 3) are 3.2, 9.5, 7.0, 9.0, 8.0, and 8.0 ng/mL with the relative standard deviation (n = 11) 4.3, 1.5, 1.9, 1.3, 1.6 and 2.1% for norfloxacin, ciprofloxacin, lomefloxacin, fleroxacin, ofloxacin and levofloxacin, respectively. This proposed method has been applied to detect FQs derivatives in human urine successfully.  相似文献   

8.
Zuo Y  Wang C  Van T 《Talanta》2006,70(2):281-285
A simple, fast, sensitive and accurate reversed-phase ion-pair HPLC method for simultaneous determination of nitrite and nitrate in atmospheric liquids and lake waters has been developed. Separations were accomplished in less than 10 min using a reversed-phase C18 column (150 mm × 2.00 mm i.d., 5 μm particle size) with a mobile phase containing 83% 3.0 mM ion-interaction reagent tetrabutylammonium hydroxide (TBA-OH) and 2.0 mM sodium phosphate buffer at pH 3.9 and 17% acetonitrile (flow rate, 0.4 mL/min). UV light absorption responses at 205 nm were linear over a wide concentration range from 100 μg/mL to the detection limits of 10 μg/L for nitrite and 5 μg/L nitrate. Quantitation was carried out by the peak area method. The relative standard deviation for the analysis of nitrite and nitrate was less than 3.0%. This method was applied for the simultaneous determination of nitrite and nitrate in dew, rain, snow and lake water samples collected in southeast Massachusetts. Nitrate was found being present at 4.79-5.99 μg/mL in dew, 1.20-2.63 μg/mL in rain, 0.32-0.60 μg/mL in snow and 0.12-0.23 μg/mL in lake water. Nitrite was only a minor species in dew (0.62-0.83 μg/mL), rain (<0.005-0.14 μg/mL), snow (0.021-0.032 μg/mL) and lake water (0.12-0.16 μg/mL). High levels of nitrite and nitrate observed in dew water droplets may constitute an important source of hydroxyl radicals in the sunny early morning.  相似文献   

9.
Oguma K  Suzuki T  Saito K 《Talanta》2011,84(5):1209-1214
A flow injection method has been developed for the determination of uranium in seawater combining the on-line preconcentration with spectrophotometric detection. An aliquot (10 mL) of the seawater sample adjusted to pH 5.5 was injected into the analytical system and uranium was adsorbed on the column packed with styrene-divinylbenzene copolymer resin (Bio-Beads SM-2) modified with dodecylamidoxime which showed high selectivity to uranium. Uranium was then eluted with 0.01 M hydrochloric acid and detected spectrophotometrically after the reaction with Chlorophosphonazo III. Interference from calcium and strontium was masked with cyclohexanediaminetetraacetic acid added to the chromogenic reagent solution. The sample throughput, the detection limit (3σ), and the preconcentration factor were 23 per hour, 0.13 μg/L, and 20, respectively, when the sample injection volume was kept at 10 mL. The precision at the 2 μg/L level was less than 4% (RSD). The proposed method was applied to the determination of uranium in the seawater samples collected off the Boso peninsula, Japan and the uranium concentration was found to be ca. 3 μg/L, which is close to the literature data. The yield of the recovery test ranged from 95% to 99%.  相似文献   

10.
Tormin TF  Gimenes DT  Richter EM  Munoz RA 《Talanta》2011,85(3):1274-1278
We report here, for the first time, application of batch injection analysis (BIA) with amperometric detection for determination of the phenolic antioxidant butylated hydroxyanisole (BHA) in biodiesel. A sample plug was directly injected onto a boron-doped diamond electrode immersed in 50% v/v hydroethanolic solution with 0.1 mol L−1 HClO4 using an electronic micropipette. Importantly, the only preparation step required for biodiesel analysis is dilution in the same hydroethanolic electrolyte solution. Our proposed method has several advantages for routine biodiesel analysis, including: a low relative standard deviation between injections (0.29%, n = 20), high analytical frequency (120 h−1), adequate recovery values (93-101%) for spiked samples, satisfactory accuracy (based on comparative determinations by high-performance liquid-chromatography), and a low detection limit (100 ng of BHA per g of biodiesel). Finally, our method can be adapted for the determination of other antioxidants in biodiesel samples.  相似文献   

11.
An analytical procedure with improved sensitivity was developed for cyanide determination in natural waters, exploiting the reaction with the complex of Cu(I) with 2,2′-biquinoline 4,4′-dicarboxylic acid (BCA). The flow system was based on the multi-pumping approach and long pathlength spectrophotometry with a flow cell based on a Teflon AF 2400® liquid core waveguide was exploited to increase sensitivity. A linear response was achieved from 5 to 200 μg L−1, with coefficient of variation of 1.5% (n = 10). The detection limit and the sampling rate were 2 μg L−1 (99.7% confidence level), and 22 h−1, respectively. Per determination, 48 ng of Cu(II), 5 μg of ascorbic acid and 0.9 μg of BCA were consumed. As high as 100 mg L−1 thiocyanate, nitrite or sulfite did not affect cyanide determination. Sulfide did not interfere at concentrations lower than 40 and 200 μg L−1 before or after sample pretreatment with hydrogen peroxide. The results for natural waters samples agreed with those obtained by a fluorimetric flow-based procedure at the 95% confidence level. The proposed procedure is then a reliable, fast and environmentally friendly alternative for cyanide determination in natural waters.  相似文献   

12.
An analytical method to identify and quantify trace levels of C5–C12 perfluorocarboxylic acids (PFCAs) in articles of commerce (AOCs) was developed and rigorously validated. Solid samples were extracted in methanol, and liquid samples were diluted with a solvent consisting of 60:40 (v/v) methanol and 2 mM ammonium acetate (NH4Ac) aqueous solution. In both cases, the samples were spiked with an isotopically labeled recovery check standard. The samples were concentrated in a nitrogen atmosphere (solid samples only), filtered, and then analyzed by HPLC coupled with a tandem mass spectrometer. Method evaluation included selection of the extraction solvent and the sample preparation solvent used to facilitate sample injection into the analytical system, method comparison for extraction and sample concentration, determination of extraction efficiency, instrument and method detection limits, and determination of potential sample loss during filtration and sample storage. Results of consecutive extractions demonstrated that a single extraction step accounts for 70–100% of the “total” PFCAs in the AOCs with the exception of cookware. The instrument's detection limit was ≤0.05 ng/mL, and the method detection limit were 1.0–3.9 ng/g for solid AOCs and 1.1–6.8 ng/g for liquid AOCs. The method has been used to determine the PFCA content in a wide range of AOCs containing or treated with fluoropolymers and fluorotelomers.  相似文献   

13.
A sensitive and selective column adsorption method is proposed for the preconcentration and determination of diazinon. Diazinon was preconcentrated on multiwalled carbon nanotubes (MWCNTs) as an adsorbent and then determined by high-performance liquid chromatography (HPLC). Several parameters on the recovery of the analyte were investigated. The experimental results showed that it was possible to obtain quantitative analysis when the solution pH was 6 using 200 mL of validation solution containing 2 μg of diazinon and 5 mL of acetonitrile as an eluent. Recovery of diazinon was 95.2 ± 4.2% with a relative standard deviation for seven determinations of 4.9% under optimum conditions. The maximum preconcentration factor was 200 for diazinon when 1000 mL of sample solution volume was used. The linear range of calibration curve was 0.3 to 10,000 ng mL− 1 with a correlation coefficient of 0.997 and the detection limit (3S/N) was 0.06 ng mL− 1. The proposed method was successfully applied to the determination of diazinon in tap water with high precision and accuracy.  相似文献   

14.
A simple and efficient dual preconcentration method of on-column liquid–liquid–liquid microextraction (LLLME) coupled with base stacking was developed for capillary zone electrophoresis (CZE) in this paper. Four N-methyl carbamates were used as target compounds to evaluate the enrichment means. The carbamates in sample solutions (donor phase) were extracted into a dodecanol phase immobilized on a porous hollow fiber, hydrolyzed and back extracted into 0.20 μL running buffer (acceptor phase) of 30 mmol/L methylamine hydrochloride (pH 11.6) containing 0.5 mmol/L tetradecyltrimethylammonium bromide inside the hollow fiber, stacked further with 0.5 mol/L NaOH injected at −10 kV for 60 s, and separated by CZE. Analytical parameters affecting the LLLME, base stacking and CZE were investigated, including sample solution volume, pH and temperature, extraction time, stirring rate, buffer component, buffer pH, NaOH concentration, stacking time, etc. The enrichment factors of the carbamates were higher than 1100. The relative standard deviation (RSD) of peak height and limits of detection (LODs) were 4.5–5.5% (n = 6) and 2–4 ng/mL (S/N = 3) for standard solutions, respectively. The proposed method was applied to the analysis of vegetable and fruit samples with the RSD less than 6.0% (n = 3) and LODs of 6–10 ng/g (S/N = 3). The calibration solutions were prepared by diluting the stock solutions with blank sample solutions, and the calibration concentrations ranged from 0.012 to 1.0 μg/mL (r > 0.9951). The analytical results demonstrated that the LLLME coupled with base stacking was a simple, convenient and reliable on-column sample pretreatment method for the analysis of anionic analytes in CZE.  相似文献   

15.
We developed a sensitive and useful method for the determination of five fluoroquinolones (FQs), enoxacin, ofloxacin, ciprofloxacin, norfloxacin, and lomefloxacin in environmental waters, using a fully automated method consisting of in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-tandem mass spectrometry (LC/MS/MS). These compounds were analysed within 7 min by high-performance liquid chromatography (HPLC) using a CAPCELL PAK C8 column and aqueous ammonium formate (pH 3.0, 5 mM)/acetonitrile (85/15, v/v) at a flow rate of 0.2 mL/min. Electrospray ionization conditions in the positive ion mode were optimized for MS/MS detection. In order to optimize the extraction of FQs, several in-tube SPME parameters were examined. The optimum in-tube SPME conditions were 20 draw/eject cycles of 40 μL of sample at a flow-rate of 150 μL/min, using a Carboxen 1010 PLOT capillary column as an extraction device. The extracted compounds were easily desorbed from the capillary by passage of the mobile phase. Using the in-tube SPME LC/MS/MS method, good linearity of the calibration curve (r ≥ 0.997) was obtained in the concentration range from 0.1 to 10 ng/mL for all compounds examined. The limits of detection (S/N = 3) of the five FQs ranged from 7 to 29 pg/mL. The in-tube SPME method showed 60-94-fold higher sensitivity than the direct injection method (5 μL injection). This method was applied successfully to the analysis of environmental water samples without any other pretreatment and interference peaks. Several surface waters and wastewaters were collected from the area around Asahi River, and ofloxacin was detected in wastewater samples of a sewage treatment plant and other two hospitals at 17.5-186.2 pg/mL. The recoveries of FQs spiked into river water were above 81% for a 0.1 or 0.2 ng/mL spiking concentration, and the relative standard deviations were below 1.9-8.6%.  相似文献   

16.
In the present study, an analytical method using capillary electrophoresis with on-line preconcentration technique was developed for rapid determination of melamine in infant formula. Both stacking and sweeping preconcentration techniques had been investigated for the comparison of their effectiveness in melamine analysis. The limit of detection of melamine standard was 0.5 ng/mL for the field amplified sample stacking (FASS) technique and 9.2 ng/mL for the sweeping technique. Although the FASS technique provided better concentration efficacy than the sweeping technique, the matrix effect was more profound with the former. Matrix effect was evaluated by comparing the enhancement factor (EF) of melamine standard and post-extraction spiked infant formula solution. The EF was changed from 429.86 ± 9.81 to the level less than 133.31 with significant peak distortion in the FASS system, and it was remained unchanged in the sweeping system. Sweeping-micellar electrokinetic chromatography (sweeping-MEKC) was demonstrated to be most suitable for real sample analysis. Under optimum sweeping-MEKC conditions, melamine content in infant formulas could be determined within 6 min. The developed solid phase extraction (SPE) procedures coupled with the sweeping-MEKC method was subjected to method validation. Run-to-run repeatability (n = 3) and day-to-day reproducibility (n = 3) of peak area were within 3.6% and 4.8% RSD, respectively. The accuracy was tested by spiking 0.5 and 2 μg/mL of melamine standard in the melamine contaminated milk powder provided by the European Commission, and the recoveries were 93.4 ± 0.5% and 98.7 ± 0.4%, respectively. Results of this study show a great potential for the sweeping-MEKC method as a tool for the fast screening of melamine in infant formulas.  相似文献   

17.
A one-step microwave-assisted headspace solid-phase microextraction (MA-HS-SPME) has been applied to be a pretreatment step in the analysis of aqueous pyrethroid residuals by gas chromatography (GC) with electron capture detection (ECD). Microwave heating was applied to accelerate the vaporization of pyrethroids (bioallenthrin, bifenthrin, fenpropathrin, cyhalothrin, permethrin, cyfluthrin, cypermethrin, fluvalinate, fenvalerate and deltamethrin) into the headspace, and then being absorbed directly on a SPME fiber under the controlled conditions. Optimal conditions for the SPME sampling, such as the selection of sampling fiber, sample pH, sampling temperature and time, microwave irradiation power, desorption temperature and time were investigated and then applied to real sample analysis. Experimental results indicated that the extraction of pyrethroids from a 20-mL aquatic sample (pH 4.0) was achieved with the best efficiency through the use of a 100-μm PDMS fiber, microwave irradiation of 157 W and sampling at 30 °C for 10 min. Under optimum conditions, the detections were linear in the range of 0.05-0.5 μg/L with the square of correlation coefficients (R2) of >0.9913 for pyrethroids except bifenthrin being 0.9812. Method detection limits (MDL) were found to be varied from 0.2 to 2.6 ng/L for different pyrethroids based on S/N (signal to noise) = 3. The coefficients of variation (CVs) for repeatability were 7-21%. A field underground water sample was analyzed with recovery between 88.5% to 115.5%. This method was proven to be a very simple, rapid, and solvent-free process to achieve the sample pretreatment before the analysis of trace pyrethroids in aqueous samples by gas chromatography.  相似文献   

18.
In the study, a kind of novel styrene-co-4-vinylpyridine (St-co-4-VP) porous magnetic polymer beads was prepared by microwave irradiation using suspension polymerization. Microwave heating preparation greatly reduced the polymerization time to 1 h. Physical characteristic tests suggested that these beads were cross-linking and possessed spherical shape, good magnetic response and porous morphologies with a narrow diameter distribution of 70–180 μm. Therefore, these beads displayed the long-term stability after undergoing 100-time extractions. Then, an analytical method for the determination of trace 24-epiBR in plant samples was developed by magnetic polymer bead extraction coupled with high performance liquid chromatography–fluorescence detection. St-co-4-VP magnetic polymer beads demonstrated the higher extraction selectivity for 24-epiBR than other reference compounds. Linear range was 10.00–100.0 μg/L with a relative standard deviation (RSD) of 6.7%, and the detection limit was 6.5 μg/kg. This analytical method was successfully applied to analyze the trace 24-epiBR in cole and breaking-wall rape pollen samples with recoveries of 77.2–90.0% and 72.3–83.4%, respectively, and RSDs were less than 4.1%. The amount of 24-epiBR in real breaking-wall rape pollen samples was found to be 26.2 μg/kg finally. This work proposed a sensitive, rapid, reliable and convenient analytical method for the determination of trace brassinosteroids in complicated plant samples by the use of St-co-4-VP magnetic polymer bead extraction coupled with chromatographic method.  相似文献   

19.
A simple, rapid and sensitive high-performance liquid chromatography (HPLC) method has been developed for the determination of triptolide. Triptolide was separated from skin endogenous and blank matrices on a 5 μm LiChrospher RP-C18 column by a mobile phase of methanol-water (65:35, v/v). The permeation samples were injected directly without pretreatment. The limit of quantitation (LOQ) and detection (LOD) for triptolide in permeation samples were far below (0.01 and 0.005 μg/mL, respectively). The method was linear over the range of 0.1-104.2 μg/mL with r2 = 0.9999. This HPLC assay is promising for measuring in vitro percutaneous penetration of triptolide through mice skins and also can be performed in the triptolide-loaded microemulsions formulation screening.  相似文献   

20.
Zhao Y  Zheng J  Yang M  Yang G  Wu Y  Fu F 《Talanta》2011,84(3):983-988
An enzyme-assisted extraction used to extract all species of selenium in rice sample and a sensitive analytical method for the determination of ultratrace Se(VI), Se(IV), SeCys2 (selenocystine) and SeMet (selenomethionine) with capillary electrophoresis-inductively coupled plasma mass spectrometry were firstly described in this study. The extraction method is simple, effective and can be used to extract trace selenium compounds in rice with high extraction efficiency and no altering its species. The analytical method has a detection limit of 0.1-0.9 ng Se/mL, and can be used to determine trace Se(VI), Se(IV), SeCys2 and SeMet in rice directly without any derivatization and pre-concentration. With the help of above methods, we have successfully determined Se(VI), Se(IV), SeCys2 and SeMet in selenium-enriched rice within 18 min with a recovery of 90-103% and a RSD (relative standard deviation, n = 6) of 3-7%. Our results indicated that selenium-enriched rice contained only one species of selenium, SeMet, and its concentration is in range of 0.136-0.143 μg Se/g dried weight. The proposed method providing a realistic approach for the nutritional and toxical evaluation of different selenium compounds in nutritional supplements.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号