首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Maya F  Estela JM  Cerdà V 《Talanta》2008,74(5):1534-1538
A multisyringe flow injection system (MSFIA) with spectrophotometric detection is proposed as a fast, robust and low-reagent consumption system for the determination of chloride (Cl) in waters. The system is based in the classic reaction of Cl with Fe3+ and Hg(SCN)2, but due to the hazardous properties of this last reagent, the proposed methodology has been developed with the aim to minimize the consumption of this one, consuming less than 0.05 mg of Hg for a Cl determination, being the system of this type with the lowest Hg consumption. The linear working range was between 1 and 40 mg L−1 Cl and the detection limit was 0.2 mg L−1 Cl. The repeatability (RSD) was 0.8% for a 10 mg L−1 Cl solution, and the injection throughput was 130 h−1. The proposed system is compared with other chloride monitoring flow systems, this comparison is realized with a point of view of the equilibrium between the obtained analytical features and produced residues toxicity. The proposed system was applied to the determination of Cl in mineral, tap and well water.  相似文献   

2.
Ferrer L  de Armas G  Miró M  Estela JM  Cerdà V 《Talanta》2004,64(5):1119-1126
In this paper, a fully software-controlled multisyringe flow injection (MSFIA) spectrophotometric system is proposed for the determination of sulfide in environmental and waste waters. The implementation of ancillary solenoid valves into the flow network allows a multitude of injection modalities to be explored, the selected modality being directly dependent on the aim of the assays. The multicommuted sandwich-type approach is introduced in this work as an efficient means to warrant high sensitivity for the particular assay with excellent repeatabilities and a considerable reagent saving. Moreover, a high injection frequency may be easily attained by carrying out a multiple injection modality during a single forward displacement of the piston driver bar. The interfacing of the robust and versatile multisyringe piston pump with an optical fiber plug-in spectrophotometer furnished with a light emitting diode enables the miniaturization of the flow analyzer, which is thus readily adaptable to in-situ and real-time monitoring schemes. The flow method is based on the coupling Fischer’s reaction of sulfide with N,N-dimethyl-p-phenylenediamine in the presence of Fe(III) as oxidizing reagent in a 0.7 M HCl medium. Careful selection of the physical and chemical variables enabled coefficients of variations better than 1.5% (n = 10) at the 1 mg l−1 level for both injection modalities. Dynamic working ranges of 0.2–2.0 and 0.5–5 mg l−1 sulfide for sandwich and multiple injection techniques, and detection limits of 0.09 and 0.15 mg l−1, respectively, were obtained. Furthermore, the sandwich modality featured an average slope of 0.43 ± 0.02 l mg−1 calculated from 10 day-to-day calibration plots. This result reveals better sensitivity than other flowing stream methods described in the literature. The multiple injection technique allowed an improvement of the injection throughput up to 80 h−1, although a decrease of sensitivity was concomitantly observed (average slope of 0.17 ± 0.01 l mg−1).

The multisyringe flow method was successfully applied to the determination of sulfide in different spiked water matrices (namely, mineral, tap, freshwater, seawater and wastewater) with recoveries ranging from 96 to 104%. Good agreement was also found in water samples between the MSFIA results and those of the batch APHA-standard method.  相似文献   


3.
A fully automated flow-through microcolumn fractionation system with on-line post-extraction derivatization is proposed for monitoring of orthophosphate in solid samples of environmental relevance. The system integrates dynamic sequential extraction using 1.0 mol l−1 NH4Cl, 0.1 mol l−1 NaOH and 0.5 mol l−1 HCl as extractants according to the Hieltjes-Lijklema (HL) scheme for fractionation of phosphorus associated with different geological phases, and on-line processing of the extracts via the Molybdenum Blue (MB) reaction by exploiting multisyringe flow injection as the interface between the solid containing microcolumn and the flow-through detector. The proposed flow assembly, capitalizing on the features of the multicommutation concept, implies several advantages as compared to fractionation analysis in the batch mode in terms of saving of extractants and MB reagents, shortening of the operational times from days to hours, highly temporal resolution of the leaching process and the capability for immediate decision for stopping or proceeding with the ongoing extraction. Very importantly, accurate determination of the various orthophosphate pools is ensured by minimization of the hydrolysis of extracted organic phosphorus and condensed inorganic phosphates within the time frame of the assay. The potential of the novel system for accommodation of the harmonized protocol from the Standards, Measurement and Testing (SMT) Program of the Commission of the European Communities for inorganic phosphorus fractionation was also addressed. Under the optimized conditions, the lowest detectable concentration at the 3σ level was ≤0.02 mg P l−1 for both the HL and SMT schemes regardless of the extracting media. The repeatability of the MB assay was better than 2.5% and the dynamic linear range extended up to 7.0 mg P l−1 in NH4Cl and NaOH media and 15 mg P l−1 whenever HCl is utilized as extractant for both the HL and SMT protocols.  相似文献   

4.
《Analytica chimica acta》2002,455(1):149-157
A time-based multisyringe flow injection procedure with spectrofluorimetric detection is proposed in this paper for the determination of aluminium in drinking water. The flow methodology is based on the simultaneous or sequential injection of sample and chelating reagent (viz. 8-hydroxyquinoline-5-sulphonic acid) plugs using a multicommutation approach so that three successive injections may be performed with a sole displacement of the piston driver bar of the burette. Thus, an injection throughput as high as 154 h−1 is achieved by sampling a 182 μl sample zone. In order to enhance the luminescence, the reaction is carried out in micellar medium using hexadecyltrimethylammonium chloride as surfactant. The influence of geometric and hydrodynamic variables as well as several parameters such as multicommutation timing, ligand and surfactant concentration and reagent pH was assessed.Under the selected working conditions, a linear dynamic range from 10 to 500 μg l−1 Al(III), a 3σ detection limit of 0.5 μg l−1 and a coefficient of variation of 0.6% at the 30 μg l−1 level were obtained. The analytical features were compared with those reported in previous flow injection and sequential injection methods. The multisyringe technique was successfully applied to the determination of aluminium in drinking water at low mineralisation levels, validating the results by inductively coupled plasma atomic emission spectrometry.  相似文献   

5.
An integrated analyzer based on the multisyringe flow injection analysis approach is proposed for the automated determination of dissolved oxygen in seawater. The entire Winkler method including precipitation of manganese(II) hydroxide, fixation of dissolved oxygen, dissolution of the oxidized manganese hydroxide precipitate, and generation of iodine and tri-iodide ion are in-line effected within the flow network. Spectrophotometric quantification of iodine and tri-iodide at the isosbestic wavelength of 466 nm renders enhanced method reliability. The calibration function is linear up to 19 mg L−1 dissolved oxygen and an injection frequency of 17 per hour is achieved. The multisyringe system features a highly satisfying signal stability with repeatabilities of 2.2% RSD that make it suitable for continuous determination of dissolved oxygen in seawater. Compared to the manual starch-end-point titrimetric Winkler method and early reported automated systems, concentrations and consumption of reagents and sample are reduced up to hundredfold. The versatility of the multisyringe assembly was exploited in the implementation of an ancillary automatic batch-wise Winkler titrator using a single syringe of the module for accurate titration of the released iodine/tri-iodide with thiosulfate.  相似文献   

6.
A fully automated flow system for drug-dissolution studies based on the sequential injection analysis (SIA) was described and used for monitoring dissolution profiles of Ergotamine Tartrate (ET) in pharmaceutical formulations. 50 μl of dissolution medium was taken for each measurement at a flow rate of 40 μl s−1 and detected by fluorescence detector using λex=236 nm (λem≥390 nm). The calibration curve was linear over the range 0.03–0.61 mg l−1 of ET (sufficient for the dissolution tests). Equation of the calibration curve was calculated giving the following values: F=117.7 c+0.80 (n=6); r=0.9998. Detection limit was 0.01 mg l−1 of ET. The R.S.D. is less than 0.54 and 0.86% (n=10) when determining 0.61 and 0.03 mg l−1 of ET in standard solution, respectively. The dissolution test of Bellaspon tablets (0.3 mg of ET in 1 tablet) was programmed for 20 min, with a continuous sampling rate of 120 h−1 under conditions required by BP 1993.  相似文献   

7.
Leal LO  Forteza R  Cerdà V 《Talanta》2006,69(2):500-508
In this study, a new technique by hydride generation-atomic fluorescence spectrometry (HG-AFS) for determination and speciation of inorganic arsenic using multisyringe flow injection analysis (MSFIA) is reported. The hydride (arsine) was generated by injecting precise known volumes of sample, a reducing sodium tetrahydroborate solution (0.2%), hydrochloric acid (6 M) and a pre-reducing solution (potassium iodide 10% and ascorbic acid 0.2%) to the system using a multisyringe burette coupled with one multi-port selection valve. This solution is used to pre-reduce As(V) to As(III), when the task is to speciate As(III) and As(V). As(V) is determined by the difference between total inorganic arsenic and As(III). The reagents are dispensed into a gas-liquid separation cell. An argon flow delivers the arsine into the flame of an atomic fluorescence spectrometer. A hydrogen flow has been used to support the flame. Nitrogen has been employed as a drier gas (Fig. 1).Several variables such as sample and reagents volumes, flow rates and reagent concentrations were investigated in detail. A linear calibration graph was obtained for arsenic determination between 0.1 and 3 μg l−1. The detection limit of the proposed technique (3σb/S) was 0.05 μg l−1. The relative standard deviation (R.S.D.) of As at 1 μg l−1 was 4.4 % (n = 15). A sample throughput of 10 samples per hour was achieved. This technique was validated by means of reference solid and water materials with good agreement with the certified values. Satisfactory results for speciation of As(III) and As(V) by means of the developed technique were obtained.  相似文献   

8.
Leal LO  Semenova NV  Forteza R  Cerdà V 《Talanta》2004,64(5):1335-1342
A new multisyringe flow injection system for inorganic arsenic determination at trace levels by hydride generation-atomic fluorescence spectrometry (HGAFS) is presented. Preconcentration on a solid-phase was carried out using a column packed with an anion-exchange resin (Amberlite IRA-410). The reagents are dispensed to the system using a multisyringe burette coupled with two multi-port selection valves.

Different parameters were changing in order to make the system as effective as possible. An analytical curve was obtained for arsenic determination between 50 and 2000 ng l−1. This new approach improved five times the sensitivity over a MSFIA–HGAFS technique developed previously by the authors. Detection limit of the proposed technique was (3σb/S) of 30 ng l−1. The relative standard deviation (R.S.D.) of As at 1 μg l−1 was 4.8% (n=7). A sample throughput of 10 h−1 has been achieved. The proposed method has been applied to different reference solid and water materials with satisfactory results.  相似文献   


9.
A multisyringe flow injection analysis system was used for the determination of hypochlorite in cleaning agents, by measurement of the native absorbance of hypochlorite at 292 nm. The methodology was based on the selective decomposition of hypochlorite by a cobalt oxide catalyst giving chloride and oxygen. The difference of the absorbance of the sample before and after its pass through a cobalt oxide column was selected as analytical signal. As no further reagent was required this work can be considered as a contribution to environmental friendly analytical chemistry. The entire analytical procedure, including in-line sample dilution in three steps was automated by first, dilution in a stirred miniature vessel, second by dispersion and third by in-line addition of water using multisyringe flow injection technique. The dynamic concentration range was 0.04-0.78 g L−1 (relative standard deviation lower than 3%), where the extension of the hypochlorite decomposition was of 90 ± 4%. The proposed method was successfully applied to the analysis of commercial cleaning products. The accuracy of the method was established by iodometric titration.  相似文献   

10.
A new analytical method was developed for on-line monitoring of residual coagulants (aluminium and iron salts) in potable water. The determination was based on a sequential procedure coupling an extraction/enrichment step of the analytes onto a modified resin and a spectrophotometric measurement of a surfactant-sensitized binary complex formed between eluted analytes and Chrome Azurol S. The optimization of the solid phase extraction was performed using factorial design and a Doehlert matrix considering six variables: sample percolation rate, sample metal concentration, flow-through sample volume (all three directly linked to the extraction step), elution flow rate, concentration and volume of eluent (all three directly linked to the elution step). A specific reagent was elaborated for sensitive and specific spectrophotometric determination of Al(III) and Fe(III), by optimizing surfactant and ligand concentrations and buffer composition. The whole procedure was automated by a multisyringe flow injection analysis (MSFIA) system. Detection limits of 4.9 and 5.6 μg L−1 were obtained for Al(III) and Fe(III) determination , respectively, and the linear calibration graph up to 300 μg L−1 (both for Al(III) and Fe(III)) was well adapted to the monitoring of drinking water quality. The system was successfully applied to the on-site determination of Al(III) and Fe(III) at the outlet of two water treatment units during two periods of the year (winter and summer conditions).  相似文献   

11.
A novel optical fibre reflectance sensor coupled to a multisyringe flow injection system (MSFIA) for the determination and speciation analysis of iron at trace level using chelating disks (iminodiacetic groups) is proposed. Once iron(III) has been retained onto a chelating disk, an ammonium thiocyanate stream is injected in order to form the iron(III)-thiocyanate complex which is spectrophotometrically detected at 480 nm. Iron(III) is eluted with 2 M hydrochloric acid so that the chelating disk is regenerated for subsequent experiments. The determination of total iron is achieved by the on-line oxidation of iron(II) to iron(III) with a suitable hydrogen peroxide stream.A mass calibration was feasible in the range from 0.001 to 0.25 μg. The detection limit (3sb/S) was 0.001 μg. The repeatability (RSD), calculated from nine replicates using 1 ml injections of a 0.1 mg/l concentration, was 2.2%. The repeatability between five chelating disks was 3.6%. The applicability of the proposed methodology in fresh and seawater samples has been proved.The proposed technique has been validated by replicate analysis (n = 4) of certified reference materials of water with satisfactory results.  相似文献   

12.
A review on sequential injection methods for water analysis   总被引:1,自引:0,他引:1  
The development of fast, automatic and less expensive methods of analysis has always been the main aim of flow methodologies. The search for new procedures that still maintain the reliability and accuracy of the reference procedures is an ever growing challenge. New requirements are continually added to analytical methodologies, such as lower consumption of samples and reagents, miniaturisation and portability of the equipment, computer interfaces for full decision systems and so on. Therefore, the development of flow methodologies meeting the extra requirements of water analysis is a challenging work.Sequential injection analysis (SIA) presents a set of characteristics that make it highly suitable for water analysis. With sequential injection analysis, most routine determinations in waters can be performed more quickly with much lower reagent consumption when compared to reference procedures. Additionally, SIA can be a valuable tool for analyte speciation and multiparametric analysis. This paper critically reviews the overall work in this area.  相似文献   

13.
Passos ML  Saraiva ML  Santos JL  Reis S  Lúcio M  Lima JL 《Talanta》2011,84(5):1309-1313
According to the current demands of environmentally friendly analytical chemistry and with a view to achieving lower reagent consumption with improved analytical performance, an automatic methodology composed of a photoreactor and fluorimetric detection (λexc = 287 nm, λem = 378 nm) was developed. To this end, a sequential injection analysis (SIA) system was developed for indomethacin determination using ultra-violet (UV) light which promotes an increase in the fluorescence of indomethacin. This increase in sensitivity makes it possible to apply this methodology to a dissolution test and to determine indomethacin in pharmaceutical formulations.The calibration graph for indomethacin was linear between 4.10 × 10−6 and 9.00 × 10−5 mol L−1and the detection limit was 1.23 × 10−6 mol L−1. The method was proven to be reproducible with a R.S.D. < 5% and sampling rate of approximately 20 per hour. The potential effect of several compounds commonly used as excipients on analytical signals was studied and no interfering effect was observed. Statistical evaluation at the 95% confidence level showed good agreement between the results obtained for the pharmaceutical samples with both the SIA system and comparison batch procedures.  相似文献   

14.
A PC-controlled sequential injection analysis (SIA) system equipped with a spectrophotometric diode-array detector is used for rapid monitoring and evaluation of antioxidation/radical scavenging activity of biological samples. The automated method is based on the known reaction of stable 2,2-diphenyl-1-picrylhydrazyl radical (DPPH) with antioxidants in organic or aqueous-organic media resulting in bleaching of DPPH due to its quenching by the interaction with the analytes. The decrease of the absorbance of DPPH (compared to blank experiment carried out with water–ethanol 1:1 instead of the test solution) measured at 525 nm is related to concentration of an antioxidant in the test solution. With the optimised SIA procedure it is possible to detect down to micromolar concentrations of model antioxidants such as ascorbic acid, caffeic acid, (+)-catechin, (–)-epicatechin and rutin and to evaluate the concentration of these antioxidants in the micromolar to millimolar range. The sample throughput is 45 h–1. Thanks to its rapidity and sensitivity, the proposed SIA method is suitable for performing routine screening tests for the presence of various antioxidants in large series of lyophilised herbal or mushroom extracts (the amount of sample needed for the analysis is several milligrams).  相似文献   

15.
A new separation method based on a novel reversed-phase sequential injection chromatography (SIC) technique was used for simultaneous determination of ambroxol hydrochloride and doxycycline in pharmaceutical preparations in this contribution.The coupling of short monolith with SIA system results in an implementation of separation step to until no-separation low-pressure method.A Chromolith® Flash RP-18e, 25-4.6 mm column (Merck, Germany) and a FIAlab® 3000 system (USA) with a six-port selection valve and 5 ml syringe were used for sequential injection chromatographic separations in our study. The mobile phase used was acetonitrile-water (20:90, v/v), pH 2.5 adjusted with 98% phosphoric acid, flow rate 0.48 ml min−1, UV detection was at 213 nm.The validation parameters have shown good results: linearity of determination for both compounds including internal standard (ethylparaben) >0.999; repeatability of determination (R.S.D.) in the range 0.5-5.4% at three different concentration levels, detection limits in the range 0.5-2.0 μg ml−1, and recovery from the pharmaceutical preparation in the range 99.3-99.9%. The chromatographic resolution between peak compounds was >5.0 and analysis time was <9 min under the optimal conditions. The method was found to be applicable for routine analysis of the active compounds ambroxol hydrochloride and doxycycline in various pharmaceutical preparations.  相似文献   

16.
Oms MT  Cerdà A  Cerdà V 《Talanta》2003,59(2):319-326
An automatic method for the determination of total nitrogen in wastewater by sequential injection analysis and mineralization with UV radiation has been developed. The method is based on the mineralization of the samples with sodium persulphate in basic medium under UV radiation. Small volumes of sample and reagents are firstly aspirated into a single channel and then propelled by flow reversal to the UV reactor and then to the detector. The organic and inorganic nitrogen compounds are oxidized to nitrate that is then measured at 226 nm. The sequential injection procedure has been optimized and the factors affecting the efficiency of the oxidation have been studied with a number of test substances with different chemical structures and properties. Solutions in the concentration range 1-56 g l−1 of nitrogen can be analyzed with the described procedure. The sample rate is of 30-40 samples h−1. The LOD is 0.6 mg l−1 N and the reproducibility is 1.8% (28 mg l−1 N). Organic carbon in the form of glucose was added to a number of test solutions to study the potential interference of organic matter.The method was compared with the Kjeldahl digestion method by analyzing 15 wastewater samples with both methods. The nitrate and nitrite content of the non-oxidized samples were subtracted from the corresponding nitrogen content determined after photo-oxidation and the value compared with the Kjeldahl nitrogen content.  相似文献   

17.
Aim of this study was to automate sampling and quantification of the previously described apparatus for combined determination of dissolution and permeation through Caco-2 monolayer by means of sequential injection analysis (SIA). Native fluorescence of propranolol HCl in Krebs-Ringer buffer (KRB) was used for quantification. Sampling was done at three different locations within the apparatus at a high sampling frequency (approximately 60 h−1). Injection volume delivered to the fluorescence detector was 50 μL for permeation monitoring and 25 μL for dissolution monitoring. Linear regression for 50 μL injection yielded a detection limit calculated as 0.04 μg mL−1 of propranolol HCl in KRB (R2 > 0.999). However, linearity for dissolution monitoring was not given for the complete range of concentrations and first order polynomial calibration was established (R2 > 0.9999). To conclude, the SIA system was able to monitor simultaneously dissolution and permeation of the immediate release propranolol HCl tablets and the authors succeeded in automating the apparatus for combined measurement of dissolution and permeation. In addition, the obtained data was consistent with data obtained by manual sampling followed by HPLC analysis.  相似文献   

18.
Mai TD  Hauser PC 《Talanta》2011,84(5):1228-1233
Pressure assisted capillary electrophoresis in capillaries with internal diameters of 10 μm was found possible without significant penalty in terms of separation efficiency and sensitivity when using contactless conductivity detection. A sequential injection analysis manifold consisting of a syringe pump and valves was used to impose a hydrodynamic flow in the separation of some inorganic as well as organic cations. It is demonstrated that the approach may be used to optimize analysis time by superimposing a hydrodynamic flow parallel to the electrokinetic motion. It is also possible to improve the separation by using the forced flow to maintain the analytes in the capillary, and thus the separation field, for longer times. The use of the syringe pump allows flexible and precise control of the pressure, so that it is possible to impose pressure steps during the separation. The use of this was demonstrated for the speeding up of late peaks, or forcing repeated passage of the sample plug through the capillary in order to increase separation.  相似文献   

19.
Various flow sample handling approaches coupled to capillary electrophoresis (CE) are reviewed, covering the research in this field in the 12 years since the milestone year of 1997, when practical interfaces to on-line couple flow injection (FI) and capillary electrophoresis were first developed independently by two research groups. Some previous attempts are also presented. Since 1997 a plethora of ingenious coupled systems have been developed. Although several reviews are available on various aspects of the topic, we have opted for a comprehensive overview of all FI-CE systems, as well as related and similar systems. This coupling has thus also led to the development of systems based on hybrids between the classical and microchip approaches. Truly microchip FI-CE systems are also included in this review.The developed systems have been used for various sample treatments, including on-line membrane-assisted sample treatment, column-based preconcentration, on-line derivatization and monitoring, to name just a few. The utility of coupling flow sampling to CE has been demonstrated in various practical applications that are discussed in detail. The current state-of-the-art and foreseeable future developments are also discussed.  相似文献   

20.
According to the current demands of Green Analytical Chemistry and regarding the need for lower reagent consumption with improved analytical performance, an automatic methodology with a flow-through optosensor incorporating solid-phase spectrophotometric detection was developed. The sensor used in this work was based on the redox state of thionine whose oxidized form is blue and reduced form is colorless with monitoring carried out at 621 nm. This redox indicator was immobilized on gel beads and subsequently packed into a flow-through cell. It was then assembled into a sequential injection system and was shown to be an excellent alternative to monitor enzymatic redox reactions automatically as the redox catalysis is performed by glucose dehydrogenase. This enzyme is a representative dehydrogenase enzyme and uses NAD+ as cofactor, promoting the oxidation of glucose to glucono-lactone and reduction of NAD+ to NADH. The produced NADH promotes color depletion on the surface of the sensor. The calibration graph for glucose was linear between 5.74 × 10−4 and 2.00 × 10−3 mol L−1 and detection limit was 1.72 × 10−4 mol L−1. Glucose concentration in different samples including sera, salines, perfusion solutions, powder for preparing oral solutions and solutions for hemodialysis was determined. The method proved to be reproducible with a RSD < 5% for glucose determinations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号