首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A photoelectroactive film composed of CdS quantum dots and graphene sheets (GS) was coated on F-doped SnO2 (FTO) conducting glass for studying the electrochemical response of p-phenylenediamine (PPD) under photoirradiation. The result indicated that the cyclic voltammogram of PPD on CdS–GS hybrid film became sigmoidal in shape after exposed under visible light, due to the photoelectrocatalytic reaction. Such a photovoltammetric response was used to rapidly optimize the photoelectrocatalytic activity of hybrid films composed of different ratios of CdS to GS toward PPD. The influences of scan rate and pH on the photovoltammetric behavior of PPD on CdS–GS film revealed that although the controlled step for electrochemical process was not changed under photoirradiation, more electrons than protons might participate the photoelectrocatalytic process. Furthermore, the photoelectroactive CdS–GS hybrid film was explored for PPD determination based on the photocurrent response of film toward PPD. Under optimal conditions, the photocurrent signal on CdS–GS film was linearly proportional to the concentration of PPD ranging from 1.0 × 10−7 to 3.0 × 10−6 mol L−1, with a detection limit (3S/N) of 4.3 × 10−8 mol L−1. Our work based on CdS–GS hybrid film not only demonstrated a new facile photovoltammetric way to study the photoinduced electron transfer process of PPD, but also developed a sensitive photoelectrochemical strategy for PPD determination.  相似文献   

2.
Owing to its high affinity with phosphate, Zr(IV) can induce the aggregation of adenosine 5′-triphosphate (ATP)-stabilized AuNPs, leading to the change of surface plasmon resonance (SPR) absorption spectra and color of ATP-stabilized AuNP solutions. Based on these phenomena, visual and SPR sensors for Zr(IV) have been developed for the first time. The A660 nm/A518 nm values of ATP-stabilized AuNPs in SPR absorption spectra increase linearly with the concentrations of Zr(IV) from 0.5 μM to 100 μM (r = 0.9971) with a detection limit of 95 nM. A visual Zr(IV) detection is achieved with a detection limit of 30 μM. The sensor shows excellent selectivity against other metal ions, such as Cu2+, Fe3+, Cd2+, and Pb2+. The recoveries for the detection of 5 μM, 10 μM, 25 μM and 75 μM Zr(IV) in lake water samples are 96.0%, 97.0%, 95.6% and 102.4%, respectively. The recoveries of the proposed SPR method are comparable with those of ICP-OES method.  相似文献   

3.
A rhodamine spirolactam derivative (1) was developed as a colormetric and fluorescent chemosensor for adenosine-5′-triphosphate (ATP) via hydrogen bonds interaction. As far as we know, this is the first case to explore ATP-induced ring-opening of spirolactam in rhodamine derivatives. It exhibited a highly sensitive “turn-on” fluorescent response toward ATP with a 47-fold fluorescence intensity enhancement under 20 equiv. of ATP added. The chemosensor can be applied to the quantification of ATP with a linear range covering from 1.0 × 10−7 to 2.0 × 10−4 M and a detection limit of 2.5 × 10−8 M. The experiment results show that the response behavior of 1 toward ATP is pH independent in medium condition (pH 6.0–8.0). Most importantly, the novel chemosensor has well solved the problem of serious interferences from other nucleoside polyphosphates such as ADP and AMP generally met by previously reported typical fluorescent chemosensors for ATP. Moreover, the response of the chemosensor toward ATP is fast (response time less than 3 min). In addition, the chemosensor can be used for the fluorescence assay for protein kinase activity with satisfactory results. The chemosensor for ATP based on hydrogen bonds interaction provided a novel strategy for the design of colormetric and ratiometric fluorescent probes for other target anions with high sensitivity and selectivity.  相似文献   

4.
In the present work a systematic comparison among spectrophotometric flow injection methods for sulfide determination based on phenothiazine dye production from diverse aromatic p-substituted amines were performed. The behavior of N,N-dimethylphenyl-p-diamine (DMPD), N,N-diethylphenyl-p-diamine (DEPD), phenyl-p-diamine (PPD), p-aminophenol (PAP) and other three aromatic amines was investigated and the chemical parameters of proposed flow methods were optimized by applying central composite design. For each evaluated method the concentration of amine, Fe3+ and H2SO4 was optimized and after the evaluation of reagents addition order the flow parameters were independently ascertained. Analytical signal was strongly diminished in the presence of iodide for flow methods based on the reaction of sulfide with DMPD, PPD or DEPD while fluoride was considered as an important interference for methods based on the reaction with PPD or PAP. The evaluated aromatic amines have permitted sulfide determination in a wide concentration range from 0.05 to 3.0 mg L− 1 and limits of detection (3σ) varying from 18.8 to 51.0 μg L− 1, for DEPD and PPD, respectively. The sensitivity of flow methods based on PPD and DMPD was higher even as PAP has permitted sulfide determination in a large sulfide concentration range. In addition, higher throughput was attained for DMPD method. The proposed methods were applied for sulfide determination in industrial wastewater and the obtained results were in agreement with reference method at 95% confidence level.  相似文献   

5.
《Electroanalysis》2004,16(20):1711-1716
A glucose microbiosensor has been developed using electrochemical codeposition of glucose oxidase (GOx) along with MnO2 as mediator, onto a single carbon fiber microelectrode. A two‐step deposition of only MnO2 initially and then of MnO2 in the presence of GOx has been introduced to ensure appropriate activity of the mediator. Several parameters such as deposition potential and time, concentration levels etc. have been characterized and optimized. A thin Nafion film was applied as an immobilization/encapsulation and interference‐free protective layer. The proposed microbiosensor was employed as an amperometric glucose detector at pH 7.5 at an operating potential of +0.58 V (vs. Ag/AgCl). The microbiosensor is characterized by a well‐reproducible amperometric response, linear signal‐to‐glucose concentration range from 1.5 mmol L?1 to 15 mmol L?1, and a limit of detection (S/N=3) of 0.8 mmol L?1. The microbiosensor exhibits good stability over more than ten hours of continuous measurement.  相似文献   

6.
Chang G  Tatsu Y  Goto T  Imaishi H  Morigaki K 《Talanta》2010,83(1):61-65
Optical biosensor arrays for rapidly determining the glucose concentrations in a large number of beverage and blood samples were developed by immobilizing glucose oxidase (GOD) on oxygen sensor layer. Glucose oxidase was first encapsulated in silica based gels through sol-gel approach and then immobilized on 96-well microarrays integrated with oxygen sensing film at the bottom. The oxygen sensing film was made of an organically modified silica film (ORMOSIL) doped with tris(4,7-diphenyl-1,10-phenanthroline) ruthenium dichloride (Ru(dpp)3Cl2). The oxidation reaction of glucose by glucose oxidase could be monitored through fluorescence intensity enhancement due to the oxygen consumption in the reaction. The luminescence changing rate evaluated by the dynamic transient method (DTM) was correlated with the glucose concentration with the wide linear range from 0.1 to 5.0 mM (Y = 13.28X − 0.128, R = 0.9968) and low detection limit (0.06 mM). The effects of pH and coexisting ions were systemically studied. The results showed that the optical biosensor arrays worked under a wide range of pH value, and normal interfering species such as Na+, K+, Cl, PO43−, and ascorbic acid did not cause apparent interference on the measurement. The activity of glucose oxidase was mostly retained even after 2-month storage, indicating their long-term stability.  相似文献   

7.
A block copolymer (PS-b-poly(l-Glu)) composed of polystyrene and poly(l-glutamic acid) was used as a stabilizer for dispersion polymerization of styrene. When dispersion polymerization of styrene was conducted at 70 °C in 80% dimethylformamide-water with 0.5 wt% PS-b-poly(l-Glu), spherical polystyrene particles with Dn = 0.72 μm and narrow size distribution were obtained. Whereas AIBN concentration did not have any effects on particle size, molecular weight of the polystyrene particles was strongly dependent on the initiator concentration. As concentration of the PS-b-poly(l-Glu) increased from 0.2 to 1.0 wt%, particle size decreased from Dn = 0.91 to 0.69 μm with keeping surface area occupied by one poly(l-glutamic acid) chain about = 50 nm2. On the other hand, an increase in initial concentration of styrene from 2 to 20 wt% caused an increase in particle size from Dn = 0.48 to 1.36 μm and a decrease in surface area per poly(l-glutamic acid) block from = 91 to 45 nm2. Colloidal stability of the polystyrene particles in aqueous solution was responsive to pH due to the surface-grafted poly(l-glutamic acid). For dispersion polymerization of styrene, the PS-b-poly(l-Glu) functions as both a stabilizer and a surface modifier.  相似文献   

8.
A highly sensitive electrochemical amplification immunoassay for Salmonella typhi (S. typhi) determination has been developed for the first time by using a copper-enhanced gold nanoparticle label coupled with anodic stripping voltammetry. Monoclonal antibodies for S. typhi were first immobilized on polystyrene microwells and then captured by S. typhi bacteria. After an immunoreaction occurred, a polyclonal, antibody-colloidal gold conjugate was added to bind to the S. typhi bacteria. Next, a copper-enhancer solution containing ascorbic acid and copper (II) sulfate was added into the polystyrene microwells. The ascorbic acid was employed to reduce the copper (II) ions to copper (0), which was subsequently deposited onto the gold nanoparticle tags. After the copper was dissolved in nitric acid, the released copper ions were detected by anodic stripping voltammetry. The amount of deposited copper was related to the amount of gold nanoparticle tag present, which was controlled by the amount S. typhi attached to the polyclonal antibody-colloidal gold conjugate. Therefore, the anodic stripping peak current was linearly dependent on the S. typhi concentration over concentration range of 1.30 × 102 cfu/mL to 2.6 × 103 cfu/mL in a logarithmic plot, with a detection limit as low as 98.9 cfu/mL. The influences of the relevant experimental variables, such as the concentration of copper and the reaction time of S. typhi with antibody, were investigated. We also successfully applied this method to determine the presence of S. typhi in human serum. Our results are a step towards developing more sensitive and reliable nanoparticle immunoassays.  相似文献   

9.
The dependence of Th recovery on hydrofluoric acid (HF) concentration in nitric acid (HNO3) solutions (1–5 mol/dm3) containing 1 × 10−6 mol/dm3 of Th and various concentrations of HF and the elution behavior were studied using a commercially available UTEVA (for uranium and tetravalent actinide) resin column. Thorium recovery decreased with an increase in HF concentration in the sample solutions. The concentration of HF at which Th recovery started to decrease was ∼1 × 10−4 mol/dm3 in 1 mol/dm3 HNO3 solution, ∼1 × 10−3 mol/dm3 in 3 mol/dm3 HNO3 solution, and ∼1 × 10−2 mol/dm3 in 5 mol/dm3 HNO3 solution. When Al(NO3)3 (0.2 mol/dm3) or Fe(NO3)3 (0.6 mol/dm3) was added as a masking agent for F to the Th solution containing 1 × 10−1 mol/dm3 HF and 1 mol/dm3 HNO3, Th recovery improved from 1.4 ± 0.3% to 95 ± 5% or 93 ± 3%. Effective extraction of Th using UTEVA resin was achieved by selecting the concentration of HNO3 and/or adding masking agents such as Al(NO3)3 according to the concentration of HF in the sample solution.  相似文献   

10.
Jingmin Qiu  Hui Chen 《Talanta》2009,79(3):787-515
This paper describes an immunomagnetic separation of target bacterial cells from others by using magnetic bead. The surface of bead was coated with antibodies which can capture specific organism. The binding efficiency of immunomagnetic bead (IMB) capturing target bacterial cells was higher than 98% when the concentrations of target and interferent bacterial cells were at the same level. The concentration of bacteria was determined indirectly by detecting adenosine 5′-triphosphate (ATP) employing bioluminescence (BL) reaction of firefly luciferin-ATP. Benzalkonium chloride (BAC) was used as an ATP extractant from living bacterial cells. We found that BAC could enhance the light emission when the concentration of BAC was less than 5.3 × 10−2% (w/v) and the BL intensity reached its maximum at the concentration of BAC was 2.7 × 10−2%, which was 10-fold stronger than that without BAC. Based on the principle of the IMB, a microfluidic chip combined with immunofluorescence assay for separating and detecting bacteria simultaneously was also developed. The IMBs were magnetically fixed in the bead-beds of chip channels with a 3-mm diameter of NdFeB permanent magnet. The target bacterial cells can be captured magnetically and observed by a fluorescent microscope.  相似文献   

11.
A new, simple and sensitive spectrofluorimetric method for the determination of salicylic acid (λex = 315 nm, λem = 408 nm) using As(III) as a sensitizing reagent has been investigated by measuring the increase of fluorescence intensity of salicylic acid due to the complexation of As(III)-salicylic acid in presence of sodium dodecyl sulfate (SDS) 10−3 M. Under optimum conditions, a significant relationship was obtained between the fluorescence intensity and salicylic acid concentration. A linear calibration curve was obtained in the range 13.8-13812 μg l−1 with product-moment correlation coefficient (R) 0.99985 and detection limit 4.2 μg l−1. The R.S.D. is 2.35% (n = 5).The method was applied successfully to the determination of salicylic acid in human serum.  相似文献   

12.
Yu C  Liu G  Zuo B  Tang Y  Zhang T 《Analytica chimica acta》2008,618(2):204-209
A cataluminescence (CTL) sensor using Al2O3 nanowires as the sensing material was developed for the determination of trace pinacolyl alcohol in air samples based on the catalytic chemiluminescence (CL) of pinacolyl alcohol on Al2O3 nanowires. Eight catalysts were examined and the CL intensity on Al2O3 nanowires prepared by supercritical fluid drying was the strongest. This novel CL sensor showed high sensitivity and selectivity to gaseous pinacolyl alcohol at optimal temperature of 340 °C. Quantitative analysis was performed at a wavelength of 460 nm. The linear range of CTL intensity versus concentration of gaseous pinacolyl alcohol was 0.09 × 10−6 to 2.56 × 10−6 g mL−1 (r = 0.9983, n = 6) with a detection limit (3σ) of 0.0053 × 10−6 g mL−1. None or only very low levels of interference were observed while the foreign substances such as water vapor, ethanol, ammonia, chloroform, benzene, nitrogen dioxide, methylbenzene, hydrochloric acid, methanol and butanol were passing through the sensor. The response time of the sensor is less than 100 s, and the sensor had a long lifetime more than 60 h. The sensor would be potentially applied to analysis of the nerve agents such as Soman.  相似文献   

13.
The quantitative analysis of ketones using DNPH is usually conducted in the presence of an acid catalyst. However, this method may cause an analytical error because 2,4-dinitrophenylhydrazones have both E- and Z-stereoisomers. Purified ketone-2,4-dinitrophenylhydrazone comprised only the E-isomer. However, under the addition of acid, both E- and Z-isomers were seen. In the case of 2-butanone-, 2-pentanone- and 2-hexanone-2,4-dinitrophenylhydrazone, the equilibrium Z/E isomer ratios were 0.20, 0.21 and 0.22, respectively. In addition, when trace water was added to the hydrazone derivatives in acetonitrile solution, the concentration of ketone derivatives were seen to decrease and the concentration of free DNPH was seen to increase. The decomposition rate of 2-butanone-2,4-dinitrophenylhydrazone was dependent on the concentration of acid-catalysis and reached an equilibrium state - carbonyl, DNPH, hydrazone-derivative and H2O - within 10 h at 0.1 mol L−1 phosphoric acid solution. The equilibrium constants of ketone-2,4-dinitrophenylhydrazones, [carbonyl] [DNPH]/[hydrazone] [H2O], were relatively large and ranged from 0.74 × 10−4 to 5.9 × 10−4. Hydrazone derivatives formed from 2-ketones such as 2-pentanone, 2-hexanone and 4-methyl-2-pentanone showed lower equilibrium constants than corresponding 3-ketones. Consequently, only a minimum concentration of catalytic acid must be added. The best method for the determination of ketone-2,4-dinitrophenylhydrazones by HPLC or GC is to add phosphoric acid to both the standard reference solution and samples, forming a 0.001 mol L−1 acid solution, and analyze after 27 h.  相似文献   

14.
A method was developed to determine traces of trifluoroacetic acid as impurity in synthetic or semi-synthetic drugs as antibiotics, macropeptides, etc. Capillary electrophoresis in combination with capacitively coupled contactless conductivity detection (CE-C4D) was used due to lack of UV absorbance property of trifluoroacetic acid (TFA). The optimized method took less than 1 min with good linearity (R2 = 0.9995) for trifluoroacetic acid concentration from 2 to 100 ppm. It also has a good repeatability expressed by the relative standard deviation (% RSD) which is 1.2 and 2.1% for intraday and interday precision, respectively, at 50 ppm TFA, and good sensitivity with 0.34 ppm, 1.2 ppm LOD and LOQ, respectively. In addition, the content of TFA in synthetic drug, was determined using the validated method which gave good linearity (R2 = 0.9996) for trifluoroacetic acid spiked into drug in a concentration range of 2-80 ppm, with good intraday repeatability of 2.0%.The analysis is performed in a background electrolyte composed of 20 mM morpholinoethane-sulfonic acid (Mes) and 20 mM l-histidine (l-His) pH 6.1. Cetyltrimethylammonium bromide (CTAB) was added as flow modifier in a concentration (0.2 mM) lower than the critical micellar concentration. Ammonium formate 6 ppm was used as internal standard. The applied voltage was 30 kV in reverse polarity. A fused silica capillary with 75 μm internal diameter and total length 47 cm (31 cm to C4D detector and 37 cm to DAD detector) was used.  相似文献   

15.
In this work, an ultrasensitive fluorescent polarization immunoassay (FPIA) method based on the quantum dot/aptamer/antibody/gold nanoparticles ensemble has been developed for the detection of adenosine triphosphate (ATP). DNA hybridization is formed when ATP is present in the PBS solution containing the DNA-conjugated quantum dots (QDs) and antibody-AuNPs. The substantial sensitivity improvement of the antibody-AuNPs-enhanced method is mainly attributed to the slower rotation of fluorescent unit when QDs-labeled oligonucleotides hybridize with antibody modified the gold nanoparticle. As a result, the fluorescent polarization (FP) values of the system increase significantly. Under the optimal conditions, a linear response with ATP concentration is ranged from 8 × 10−12 M to 2.40 × 10−4 M. The detection limit reached as low as 1.8 pM. The developed work provides a sensitive and selective immunoassay protocol for ATP detection, which could be applied in more bioanalytical systems.  相似文献   

16.
A biosensor based on the ionic liquid, 1-n-butyl-3-methylimidazolium hexafluorophosphate containing dispersed iridium nanoparticles (Ir-BMI.PF6) and polyphenol oxidase was constructed. This enzyme was obtained from the sugar apple (Annona squamosa), immobilized in chitosan ionically crosslinked with oxalate. The biosensor was used for determination of chlorogenic acid by square wave voltammetry. The polyphenol oxidase catalyzes the oxidation of chlorogenic acid to the corresponding o-quinone, which is electrochemically reduced back to this substance at +0.25 V vs. Ag/AgCl. Under optimized operational conditions the chlorogenic acid concentration was linear in the range of 3.48 × 10−6 to 4.95 × 10−5 mol L−1 with a detection limit of 9.15 × 10−7 mol L−1. The biosensor was applied in the determination of chlorogenic acid in organic and decaffeinated coffee and the results compared with those obtained using the capillary electrophoresis method. The recovery study for chlorogenic acid in these samples gave values of 93.2-105.7%.  相似文献   

17.
A new method for separation/preconcentration of trace amounts of Cr, Cu and Pb in environmental samples by magnetic solid-phase extraction (SPE) with Bismuthiol-II-immobilized magnetic nanoparticles and their determination by ICP-OES has been developed. The separation of the target analytes from the aqueous solution containing the target analytes and Bismuthiol-II-immobilized magnetic nanoparticles was simply achieved by applying external magnetic field. Optimal experimental conditions including pH, sample volume, eluent concentration and volume and co-existing ions have been studied and established. Under the optimal experimental conditions, the detection limits for Cr, Cu and Pb with enrichment factors of 96, 95 and 87 were found to be 0.043, 0.058 and 0.085 ng mL−1 and their relative standard deviations (R.S.D.s) were 3.5%, 4.6% and 3.7% (n = 5, C = 2 ng mL−1), respectively. The method was validated with certified reference material (GBW50009-88) of environmental water sample and the analytical results coincided well with the certified values. Furthermore, the method was successfully applied to the determination of target analytes in river and lake water samples. Compared with established methods, the proposed method is characterized with high enrichment factor, fast separation and low detection limits.  相似文献   

18.
A new approach for in situ electrodeposition of a renewable copper layer onto a copper electrode is reported. The active surface was obtained by anodic dissolution of a copper electrode at an appropriate potential and further redeposition of copper ions still remaining at the diffusion layer. Under optimal experimental conditions the peak current response increases linearly with nitrate concentration over a range of 0.1-2.5 mmol L−1. The repeatability of measurements for nitrate was evaluated as 1.8% (N = 15) and the limit of detection of the method was found to be 11 μmol L−1 (S/N = 3). Nitrate contents in two different samples (mineral water and sausages) compared well with those obtained from using the standard Griess protocol at a 95% of confidence level measured by the t-student test. The interference from chloride on the nitrate analysis and the possibility of simultaneous determination of nitrite were also examined.  相似文献   

19.
A stability-indicating assay using a capillary zone electrophoresis method is reported for the determination of isothipendyl in an ointment formulation. Sample preparation consisted of a simple dissolution of the ointment in an internal standard (3-aminobenzoic acid hydrochloride) solution. Separation was carried out in a short fused silica capillary using a pH 2.5 phosphate buffer as electrolyte. After introduction of the sample solution into the capillary, the compounds were separated as cations and detected within 3 min. The procedure was validated following the guidelines of the International Conference on Harmonisation. The method was found to be specific in relation to potential degradation products and excipients. Linearity determined between 50 and 150% of the target concentration was satisfactory (r2 = 0.999). Recovery studies from an analytical placebo spiked with the analyte at five concentration levels (50-150% of the target concentration) on each of 3 days ranged from 103.5 to 99.2%. The repeatability of the entire procedure (n = 7) was better than 1.0%. The detection limit was estimated to be approximately 0.5 mg l−1.  相似文献   

20.
Potassium formate was extracted from airport storm water runoff by headspace solid-phase microextraction (HS-SPME) and analyzed by GC–MS. Formate was transformed to formic acid by adding phosphoric acid. Subsequently, formic acid was derivatized to methyl formate by adding methanol. Using sodium [2H]formate (formate-d) as an internal standard, the relative standard deviation of the peak area ratio of formate (m/z 60) and formate-d (m/z 61) was 0.6% at a concentration of 208.5 mg L−1. Calibration was linear in the range of 0.5–208.5 mg L−1. The detection limit calculated considering the blank value was 0.176 mg L−1. The mean concentration of potassium formate in airport storm water runoff collected after surface de-icing operations was 86.9 mg L−1 (n = 11) with concentrations ranging from 15.1 mg L−1 to 228.6 mg L−1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号