首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A chelate resin immobilizing carboxymethylated pentaethylenehexamine (CM-PEHA resin) was prepared, and the potential for the separation and preconcentration of trace elements in water samples was evaluated through the adsorption/elution test for 62 elements. The CM-PEHA resin could quantitatively recover various elements, including Ag, Cd, Co, Cu, Fe, Ni, Pb, Ti, U, and Zn, and rare earth elements over a wide pH range, and also Mn at pH above 5 and V and Mo at pH below 7. This resin could also effectively remove major elements, such as alkali and alkaline earth elements, under acidic and neutral conditions. Solid phase extraction using the CM-PEHA resin was applicable to the determination of 10 trace elements, Cd, Co, Cu, Fe, Mn, Mo, Ni, Pb, V, and Zn, in certified reference materials (EnviroMAT EU-L-1 wastewater and ES-L-1 ground water) and treated wastewater and all elements except for Mn in surface seawater using inductively coupled plasma atomic emission spectrometry. The detection limits, defined as 3 times the standard deviation for the procedural blank using 500 mL of purified water (50-fold preconcentration, n = 8), ranged from 0.003 μg L−1 (Mn) to 0.28 μg L−1 (Zn) as the concentration in 500 mL of solution.  相似文献   

2.
The analytical utility of a tungsten (W)-coil atomization-laser-induced fluorescence (LIF) approach has been evaluated for trace level measurements of elemental chromium (Cr), arsenic (As), selenium (Se), antimony (Sb), lead (Pb), tin (Sn), copper (Cu), thallium (Tl), indium (In), cadmium (Cd), zinc (Zn) and mercury (Hg). Measurements of As, Cr, In, Se, Sb, Pb, Tl, and Sn were performed by laser-induced fluorescence using a single dye laser operating near 460 nm whose output was converted by frequency doubling and stimulated Raman scattering to wavelengths ranging from 196 to 286 nm for atomic excitation. Absolute limits of detection (LODs) of 1, 0.3, 0.3, 0.2, 1, 6, 1, 0.2 and 0.8 pg and concentration LODs of 100, 30, 30, 20, 100, 600, 100, 20, and 80 pg/mL were achieved for As, Se, Sb, Sn, In, Cu, Cr, Pb and Tl, respectively. Determinations of Hg, Pb, Zn and Cd were performed using two-color excitation approaches and resulted in absolute LODs of 2, 30, 5 and 0.6 pg, respectively, and concentration LODs of 200, 3000, 500 and 60 pg/mL, respectively. The sensitivities achieved by the W-coil LIF approaches compare well with those reported by W-coil atomic absorption spectrometry, graphite furnace atomic absorption spectrometry, and graphite furnace electrothermal atomization-LIF approaches. The accuracy of the approach was verified through the analysis of a multielement reference solution containing Sb, Pb and Tl which each had certified performance acceptance limits of 19.6-20.4 μg/mL. The determined concentrations were 20.05 ± 2.60, 20.70 ± 2.27 and 20.60 ± 2.46 μg/mL, for Sb, Pb and Tl, respectively. The results demonstrate that W-coil LIF provides good analytical performance for trace analyses due to its high sensitivity, linearity, and capability to measure multiple elements using a single tunable laser and suggest that the development of portable W-coil LIF instrumentation using compact, solid-state lasers is feasible.  相似文献   

3.
Kagaya S  Araki Y  Hirai N  Hasegawa K 《Talanta》2005,67(1):90-97
The coprecipitation behavior of 44 elements (47 ions because of chromium(III,VI), arsenic(III,V), and antimony(III,V)) with yttrium phosphate was investigated at various pHs. Yttrium phosphate could quantitatively coprecipitate iron(III), lead, bismuth, and indium over a wide pH range; however, 18 ions, including alkali metals and oxo anions, such as vanadium(V), chromium(VI), molybdenum(VI), tungsten(VI), germanium(IV), arsenic(III,V), selenium(IV), and tellurium(VI), were scarcely collected. In addition, 19 ions, including cobalt, nickel, and copper(II), were hardly coprecipitated at pHs below about 3. Based on these results, the separation of iron(III), lead, and bismuth from cobalt, nickel, and copper(II) matrices was investigated. Iron(III), lead, and bismuth ranging from 0.5 to 25 μg could be separated effectively from a solution containing 0.5 g of cobalt, nickel, or copper at pH 3.0. The separated iron(III), lead, and bismuth could be determined by inductively coupled plasma atomic emission spectrometry using internal standardization. The detection limits (3σ, n = 7) of iron(III), lead, and bismuth were 0.008, 0.137, and 0.073 μg, respectively. The proposed method was applied to the analyses of metals and chlorides of cobalt, nickel, and copper.  相似文献   

4.
Cadmium ranging from 1 - 8 ng could be coprecipitated quantitatively with lanthanum phosphate at pH 5 - 6 from up to 200 mL of river water samples spiked with 5 microg of indium as an internal standard. Cadmium and indium coprecipitated were measured by using electrothermal atomic absorption spectrometry. The cadmium content in the original sample solution could be determined by internal standardization with indium. Since complete collection of the precipitate and strict adjustment of the volume of the final solution after coprecipitation are not required in this method, the precipitate could be collected by using decantation and centrifugation, and then dissolved with 1 mL of about 2.4 mol L(-1) nitric acid. The proposed method is simple and rapid, and enrichment close to 200-times can be attained; the detection limit (3sigma, n = 6) was 0.63 ng L(-1) in 200 mL of the sample solution.  相似文献   

5.
Saracoglu S  Soylak M  Elci L 《Talanta》2003,59(2):287-293
Multi-element determination of trace elements in urine and dialysis solutions by atomic absorption spectrometry has been investigated. Coprecipitation with samarium hydroxide was used for preconcentration of trace elements and elimination of matrix elements. To 10 ml of each sample was added 500 μl of 2 mg ml−1 samarium solutions; the pH was then adjusted to 12.2 in order to collect trace heavy metals on samarium hydroxide. The precipitate was separated by centrifugation and dissolved in 1 ml of 1 mol l−1 HNO3. Coprecipitation parameters and matrix effects are discussed. The precision, based on replicate analysis, is around 5% for the analytes, and recovery is quantitative, based on analysis of spiked samples and solutions including matrix components. The time required for the coprecipitation and determination was about 30 min.  相似文献   

6.
In order to determine trace amounts of phosphorus in geological and cosmochemical rock samples, simple as well as reliable analytical schemes using an ICP-AES instrument were investigated. A (conventional) ICP-AES procedure could determine phosphorus contents at the level of several 100 μg g−1 with a reasonable reproducibility (<10% for 200 μg g−1; 1σ). An ICP-AES procedure coupled with matrix-separation using cation and anion exchange resins could lower the quantification level down to 1 μg g−1 or even lower under the present experimental conditions. The matrix-separation ICP-AES procedure developed in this study was applied to twenty-one geological reference samples issued by Geological Survey of Japan. Obtained values vary from 1250 μg g−1 for JB-3 (basalt) to 2.07 μg g−1 for JCt-1 (carbonate). Matrix-separation ICP-AES yielded reasonable reproducibility (less than 8.3%; 1σ) of three replicate analyses for all the samples analyzed. In comparison of our data with certificate values as well as literature or reported values, there appear to be an apparent (and large) discrepancy between our values and certificate/reported values regardless of phosphorus contents. Based on the reproducibility of our data and the analytical capability of the matrix-separation ICP-AES procedure developed in this study (in terms of quantification limit, recovery, selectivity of an analyte through pre-concentration process, etc.), it is concluded that certified values for several reference standard rocks should be reevaluated and revised accordingly. It may be further pointed that some phosphorus data reported in literatures should be critically evaluated when they are to be referred in later publications.  相似文献   

7.
Baytak S  Zereen F  Arslan Z 《Talanta》2011,84(2):319-323
A trace element preconcentration procedure is described utilizing a minicolumn of yeast (Yamadazyma spartinae) immobilized TiO2 nanoparticles for determination of Cr, Cu, Fe, Mn, Ni and Zn from water samples by inductively coupled plasma atomic emission spectrometry. The elements were quantitatively retained on the column between pH 6 and 8. Elution was made with 5% (v/v) HNO3 solution. Recoveries ranged from 98 ± 2 (Cr) to 100 ± 4 (Zn) for preconcentration of 50 mL multielement solution (50 μg L−1). The column made up of 100 mg sorbent (yeast immobilized TiO2 NP) offers a capacity to preconcentrate up to 500 mL of sample solution to achieve an enrichment factor of 250 with 2 mL of 5% (v/v) HNO3 eluent. The detection limits obtained from preconcentration of 50 mL blank solutions (5%, v/v, HNO3, n = 11) were 0.17, 0.45, 0.25, 0.15, 0.33 and 0.10 μg L−1 for Cr, Cu, Fe, Mn, Ni and Zn, respectively. Relative standard deviation (RSD) for five replicate analyses was better than 5%. The retention of the elements was not affected from up to 500 μg L−1 Na+ and K+ (as chlorides), 100 μg L−1 Ca2+ (as nitrate) and 50 μg L−1 Mg2+ (as sulfate). The method was validated by analysis of freshwater standard reference material (SRM 1643e) and applied to the determination of the elements from tap water and lake water samples.  相似文献   

8.
A systematic evaluation of different variables affecting the enzymatic hydrolysis of mussel soft tissue by five enzymes, three proteases (pepsin, pancreatin and trypsin), lipase and amylase, has been carried out for the determination of trace elements (As, Al, Cd, Cr, Cu, Fe, Mn, Ni, Pb and Zn) by inductively coupled plasma-atomic emission spectrometry (ICP-AES). Enzymatic hydrolysis methods offers advantages such as a less species alteration, safer laboratory conditions and a less contaminant wastes. The enzymatic hydrolysis was performed in an incubation camera Boxcult with orbital and horizontal shaker. Variables affecting the enzymatic hydrolysis process were simultaneously studied by applying a Plackett-Burman design (PBD). For a confidence interval of 95%, the significant factors for all enzymes and for most of the elements were the pH, the incubation temperature and the ionic strength. These significant factors were optimized later by using a central composite design (CCD), which gave optimum conditions at pH of 1, incubation temperature of 37 °C and ionic strength fixed by sodium chloride at 0.2 M when using pepsin. For pancreatin, trypsin, lipase and amylase there were found two different optimum condition sets. The first one involves the use of a 0.5 M phosphate buffer (ionic strength), at a pH of 6 and at an incubation temperature of 37 °C, which allows the quantitative extraction of Al, Cr, Mn, Pb and Zn. The second conditions set employees a 0.1 M phosphate buffer (ionic strength), a pH of 9 and an incubation temperature at 37 °C, and it results adequate to extract As, Cd, Cu, Fe and Ni. Analytical performances, repeatability of the over-all procedure and accuracy, by analyzing DORM-1, DORM-2 and TORT-1 certified reference materials, were finally assessed for each enzyme. Good agreement with certified values has been assessed for most of the elements (As, Cd, Cr, Cu, Mn, Ni, Pb and Zn) when using trypsin, pepsin and/or pancreatin, except for Cd and Pb in DORM-1 and DORM-2 because of the certified contents in such certified reference materials are lower than the limit of detection (0.10 and 0.16 μg g−1 for Cd and Pb, respectively, for the use of trypsin).  相似文献   

9.
A new functionalized mesoporous silica (MCM-41) using salicylaldehyde was utilized for the separation, preconcentration and determination of uranium in natural water by inductively coupled plasma atomic emission spectrometry (ICP-AES).Experimental conditions for effective adsorption of trace levels of U(VI) were optimized. The preconcentration factor was 100 (1.0 mL of elution for a 100 mL sample volume). The analytical curve was linear in the range 2-1000 μg L−1 and the detection limit was 0.5 ng mL−1. The relative standard deviation (R.S.D.) under optimum conditions was 2.5% (n = 10). Common coexisting ions did not interfere with the separation and determination of uranium at pH 5. The sorbent exhibited excellent stability and its sorption capacity under optimum conditions has been found to be 10 mg of uranium per gram of sorbent. The method was applied for the recovery and determination of uranium in different water samples.  相似文献   

10.
A method for the simultaneous determination of Pb(II), Cd(II), and Zn(II) at low μg L−1 concentration levels by sequential injection analysis-anodic stripping voltammetry (SIA-ASV) using screen-printed carbon nanotubes electrodes (SPCNTE) was developed. A bismuth film was prepared by in situ plating of bismuth on the screen-printed carbon nanotubes electrode. Operational parameters such as ratio of carbon nanotubes to carbon ink, bismuth concentration, deposition time and flow rate during preconcentration step were optimized. Under the optimal conditions, the linear ranges were found to be 2-100 μg L−1 for Pb(II) and Cd(II), and 12-100 μg L−1 for Zn(II). The limits of detection (Sbl/S = 3) were 0.2 μg L−1 for Pb(II), 0.8 μg L−1 for Cd(II) and 11 μg L−1 for Zn(II). The measurement frequency was found to be 10-15 stripping cycle h−1. The present method offers high sensitivity and high throughput for on-line monitoring of trace heavy metals. The practical utility of our method was also demonstrated with the determination of Pb(II), Cd(II), and Zn(II) by spiking procedure in herb samples. Our methodology produced results that were correlated with ICP-AES data. Therefore, we propose a method that can be used for the automatic and sensitive evaluation of heavy metals contaminated in herb items.  相似文献   

11.
A multi-element preconcentration-separation technique for heavy metal ions in environmental samples has been established. The procedure is based on coprecipitation of gold(III), bismuth(III), cobalt(II), chromium(III), iron(III), manganese(II), nickel(II), lead(II), thorium(IV) and uranium(VI) ions by the aid of Cu(II)-9-phenyl-3-fluorone precipitate. The Cu(II)-9-phenyl-3-fluorone precipitate was dissolved by the addition 1.0 mL of concentrated HNO3 and then the solution was completed to 5 mL with distilled water. Iron, lead, cobalt, chromium, manganese and nickel levels in the final solution were determined by flame atomic absorption spectrometer, while gold, bismuth, uranium and thorium were determined by inductively coupled plasma mass spectrometer. The optimal conditions are pH 7, amounts of 9-phenyl-3-fluorone: 5 mg and amounts of Cu(II): 1 mg. The effects of concomitant ions as matrix were also examined. The preconcentration factor was 30. Gold(III), bismuth(III), chromium(III), iron(III), lead(II) and thorium(IV) were quantitatively recovered from the real samples. The detection limits for the analyte elements based on 3 sigma (n = 15) were in the range of 0.05-12.9 μg L−1. The validation of the presented procedure was checked by the analysis of two certified reference materials (Montana I Soil (NIST-SRM 2710) and Lake Sediment (IAEA-SL-1)). The procedure was successfully applied to some environmental samples including water and sediments.  相似文献   

12.
Yongchun Zhu  Jingjing Guan  Lu Cao  Jie Hao 《Talanta》2010,80(3):1234-1238
Electrochemical solid phase nano-extraction, a novel sample preparation technique, was used for the determination of trace iodide in iodised table salt based on the silver sulfate nanoparticle-modified carbon paste electrode. Electrochemical solid phase nano-extraction was realized in the exchange between the sulfate anion in nanoparticles and an iodide anion from aqueous solution. The released silver cation serves as the electrochemical probe for the determination of iodide. The extraction follows a Freundlich adsorption isotherm, and can be used in the detection of iodide in the concentration range 5.0 × 10−12-4.0 × 10−9 M. The amount of iodide in iodised table salt was determined as 0.875 ± 0.002 μg/g, which is about 2.5% of the addition amount of iodate with a relative deviation of 5.92% and a standard addition recovery of 90-110%. The large amounts of chloride and iodate did not interfere with the detection.  相似文献   

13.
Determinations of low atomic number elements Na, Mg and Al present at trace concentrations in uranium matrix were made by vacuum chamber total reflection X-ray fluorescence spectrometer for the first time. For this purpose, synthetic samples of uranium with known amounts of these low atomic number elements were prepared by mixing different volumes of their solutions with U solution of high purity. The concentrations of these elements in the samples were in the range of 100–300 μg/g with respect to uranium and 10–20 μg/mL in the solutions. Major matrix uranium was separated by solvent extraction with 30% solution of tri-n-butyl phosphate in dodecane. After the solvent extraction, aqueous phase containing trace elements was mixed with Sc internal standard and the samples were analyzed by vacuum chamber total reflection X-ray fluorescence spectrometer having a Cr Kα excitation source. The total reflection X-ray fluorescence results obtained, after blank corrections, indicated an average deviation of 14% from the calculated concentrations of these low atomic number elements on the basis of their preparation. However, the total reflection X-ray fluorescence determined concentration of Mg was exceptionally lower than the calculated concentration in two samples. These studies have shown that vacuum chamber total reflection X-ray fluorescence is a promising technique for the determination of low atomic number elements in uranium matrix after its separation.  相似文献   

14.
The application of sulfur microparticles as efficient adsorbents for the solid-phase extraction (SPE) and determination of trace amounts of 10 polycyclic aromatic hydrocarbons (PAHs) was investigated in sea water and wastewater samples using high performance liquid chromatography coupled with an ultraviolet detector (HPLC–UV). Parameters influencing the preconcentration of PAHs such as the amount of sulfur, solution flow rate and volume, elution solvent, type and concentration of organic modifier, and salt effect were examined. The results showed that at a flow rate of 10 mL min−1 for the sample solutions (100 mL), the PAHs could be adsorbed on the sulfur microparticles and then eluted by 2.0 mL of acetonitrile. For HPLC–UV analysis of extracted PAHs, the calibration curves were linear in the range of 0.05–80.0 μg L−1; the coefficients of determinations (r2) were between 0.9934 and 0.9995. The relative standard deviations (RSDs) for eight replicates at two concentration levels (0.5 and 4.0 μg L−1) of PAHs were lower than 7.3%, under optimized conditions. The limits of detection (LODs, <!-- no-mfc -->S/N<!-- /no-mfc --> = 3) of the proposed method for the studied PAHs were 0.007–0.048 μg L−1. The recoveries of spiked PAHs (0.5 and 4 μg L−1) in the wastewater and sea water samples ranged from 78% to 108%. The simplicity of experimental procedure, high extraction efficiency, short sample analysis, and using of low cost sorbent demonstrate the potential of this approach for routine trace PAH analysis in water and wastewater samples.  相似文献   

15.
Rosi Ketrin Katarina 《Talanta》2009,78(3):1043-990
On-line preconcentration and determination of transition and rare-earth metals in water samples was performed using a Multi-Auto-Pret system coupled with inductively coupled plasma-atomic emission spectrometry (ICP-AES). The Multi-Auto-Pret AES system proposed here consists of three Auto-Pret systems with mini-columns that can be used for the preconcentration of trace metals sequentially or simultaneously, and can reduce analysis time to one-third and running cost of argon gas and labor. A newly synthesized chelating resin, ethylenediamine-N,N,N′-triacetate-type chitosan (EDTriA-type chitosan), was employed in the Multi-Auto-Pret system for the collection of trace metals prior to their measurement by ICP-AES. The proposed resin showed very good adsorption ability for transition and rare-earth metal ions without any interference from alkali and alkaline-earth metal ions in an acidic media. For the best result, pH 5 was adopted for the collection of metal ions. Only 5 mL of samples could be used for the determination of transition metals, while 20 mL of samples was necessary for the determination of rare-earth metals. Metal ions adsorbed on the resin were eluted using 1.5 M nitric acid, and were measured by ICP-AES. The proposed method was evaluated by the analysis of SLRS-4 river water reference materials for trace metals. Good agreement with certified and reference values was obtained for most of the metals examined; it indicates that the proposed method using the newly synthesized resin could be favorably used for the determination of transition and rare-earth metals in water samples by ICP-AES.  相似文献   

16.
Zuo Y  Wang C  Van T 《Talanta》2006,70(2):281-285
A simple, fast, sensitive and accurate reversed-phase ion-pair HPLC method for simultaneous determination of nitrite and nitrate in atmospheric liquids and lake waters has been developed. Separations were accomplished in less than 10 min using a reversed-phase C18 column (150 mm × 2.00 mm i.d., 5 μm particle size) with a mobile phase containing 83% 3.0 mM ion-interaction reagent tetrabutylammonium hydroxide (TBA-OH) and 2.0 mM sodium phosphate buffer at pH 3.9 and 17% acetonitrile (flow rate, 0.4 mL/min). UV light absorption responses at 205 nm were linear over a wide concentration range from 100 μg/mL to the detection limits of 10 μg/L for nitrite and 5 μg/L nitrate. Quantitation was carried out by the peak area method. The relative standard deviation for the analysis of nitrite and nitrate was less than 3.0%. This method was applied for the simultaneous determination of nitrite and nitrate in dew, rain, snow and lake water samples collected in southeast Massachusetts. Nitrate was found being present at 4.79-5.99 μg/mL in dew, 1.20-2.63 μg/mL in rain, 0.32-0.60 μg/mL in snow and 0.12-0.23 μg/mL in lake water. Nitrite was only a minor species in dew (0.62-0.83 μg/mL), rain (<0.005-0.14 μg/mL), snow (0.021-0.032 μg/mL) and lake water (0.12-0.16 μg/mL). High levels of nitrite and nitrate observed in dew water droplets may constitute an important source of hydroxyl radicals in the sunny early morning.  相似文献   

17.
A field oriented and economical method of coprecipitation of trace elements like Al, Au, Bi, Cd, Co, Cu, Fe, Mo, Ni, Pb, Pd, Ti, V, W, Zn and REE has been developed. A novel reductant D-glucose, reduces KMnO4 in solution to form a precipitate of MnO2. Two liters of clear natural water sample is adjusted to pH 3.5–4.0, and is treated with 10 ml of 1% KMnO4 and 20 ml of 0.1% D-glucose. The sample is heated at a temperature of 75–80 °C, MnO2 is formed which coprecipitates the above trace elements. The precipitate is separated by filtration, dissolved in 2 ml of 50% HCl and 2 ml of 30% H2O2 and diluted to 25 ml for analysis using AAS and ICP-AES. The recoveries were found to be 96–105%. The preconcentration factor is 80. Limits of determination by the proposed method in natural waters are 1 μg l−1 for Al, Cd, Mo, V, W, Ti and Zn, 5 μg l−1 for Au, Bi, Co, Cu, Fe, Ni, Pb and Pd and 8 μg l−1 for REE. The RSD of the present procedure (n=5) is 8% at 5 μg l−1 level. Twenty water samples can be analyzed by an analyst in an 8-h day.  相似文献   

18.
The rapid industrial development in regions of Mexico during recent years has had the side effect of introducing toxic metals, fertilizers, and pesticides into the ecosystem. Sediment cores were collected from eight locations around the Julian Adame-Alatorre dam located in the Municipality of Villanueva in the State of Zacatecas, México. The cores were analyzed for 32 major, trace, and rare earth elements (As, La, Lu, Nd, Sm, U, Yb, Ce, Co, Cr, Cs, Eu, Fe, Hf, Rb, Sb, Sc, Sr, Ta, Tb, Th, Zn, Zr, Al, Ba, Ca, Dy, K, Mn, Na, Ti, and V) in order to estimate the health risk. The samples were analyzed by instrument neutron activation analysis (INAA) using thermal neutron fluxes of 8 × 1013 and 5 × 1013 n cm−2 s−1 for short and long irradiations, respectively. The results of the contamination levels for elements such as As, Ba, Cr, Fe, Mn, Ta, V, and Zn were compared with the Mexican regulations and the guidelines of USEPA. Enrichment factors for quantified elements identified high As, Sb, Hf, and Cs contents using Fe as a crustal reference.  相似文献   

19.
In this work, a water-soluble polymer, polyethylenimine (PEI) was used for the simultaneous separation and preconcentration of trace Cu and Mn prior to their determination by flame atomic absorption spectrometry. For this purpose, the sample and the PEI solution were mixed and the metal-bound polymer was precipitated by adding acetone. The precipitate was separated and dissolved in a minimum amounts of water and aspirated into a flame AAS. By increasing the ratio of the volumes of sample to water used in dissolving the precipitate, the analyte elements were concentrated as needed. The sorption is quantitative in the pH ≥6. Detection limits were 5.2 μg/L for Cu and 5.4 μg/L for Mn. This method is simple, fast and precise.  相似文献   

20.
By applying an internal standardization, we could use a rapid coprecipitation technique using lanthanum phosphate as a coprecipitant for preconcentration of iron(III) and lead in their flame atomic absorption spectrometric determination. Indium as an internal standard was added to the initial sample solution together with lanthanum and phosphoric acid; the coprecipitation of iron(III) and lead was then carried out at pH about 3. After measuring the atomic absorbances of iron, lead, and indium in the final sample solution, we determined the contents of iron(III) and lead in the original sample solution by using the internal standardization with indium. In this method, complete collection of the precipitate was not required after the coprecipitation of iron(III), lead, and indium, because the ratio of the recovery of iron(III) or lead to that of indium was almost constant regardless of the recovery of the precipitate. This method was simple and rapid, and was available for the determination of 2-300 micrograms L-1 of iron(III) and 5-400 micrograms L-1 of lead in some water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号