首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Gurban AM  Rotariu L  Baibarac M  Baltog I  Bala C 《Talanta》2011,85(4):2007-2013
Simple and low cost biosensor based on screen-printed electrode for sensitive detection of some alkylphenols was developed, by entrapment of HRP in a nanocomposite gel based on single-walled carbon nanotubes (SWCNTs) and 1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM][PF6]) ionic liquid. Raman and FTIR spectroscopy, CV and EIS studies demonstrate the interaction between SWCNTs and ionic liquid. The nanocomposite gel, SWCNT-[BMIM][PF6] provides to the modified sensor a considerable enhanced electrocatalytic activity toward hydrogen peroxide reduction. The HRP based biosensor exhibits high sensitivity and good stability, allowing a detection of the alkylphenols at an applied potential of −0.2 V vs. Ag/AgCl, in linear range from 5.5 to 97.7 μM for 4-t-octylphenol and respectively, between 5.5 and 140 μM for 4-n-nonylphenol, with a response time of about 5 s. The detection limit was 1.1 μM for 4-t-octylphenol, and respectively 0.4 μM for 4-n-nonylphenol (S/N = 3).  相似文献   

2.
A highly sensitive and selective glucose biosensor has been constructed by using highly dispersed NiO nanoparticles supported on well-aligned MWCNTs (NiO/MWCNTs) as sensing interface. The NiO/MWCNTs nanocomposite was synthesized by magnetron sputtering deposition of NiO nanoparticles on vertically aligned carbon nanotubes. The nanocomposite electrode showed high electrochemical activity towards the oxidation of glucose in 0.20 M NaOH solution. At an applied potential of +0.50 V, it gives a fast response time (< 5 s) and a linear dependence (R?=?0.997) on the glucose concentration up to 7.0 mM with an extraordinarily high sensitivity of 1.77 mA mM-1 cm-2 and a detection limit of 2 μM. The interference by the oxidation of common interfering species such as ascorbic acid, dopamine, uric acid, lactose, and fructose is effectively avoided. The electrode was used to analyze glucose concentration in human serum samples. It allows highly sensitive, stable, and fast amperometric sensing of glucose, which is promising for the development of nonenzymatic glucose sensors.  相似文献   

3.
Electrodeposition of Pt-Pb nanoparticles (PtPbNPs) to multi-walled carbon nanotubes (MWCNTs) resulted in a stable PtPbNP/MWCNT nanocomposite with high electrocatalytic activity to glucose oxidation in either neutral or alkaline medium. More importantly, the nanocomposite electrode with a slight modification exhibited high sensitivity, high selectivity, and low detection limit in amperometric glucose sensing at physiological neutral pH (poised at a negative potential). At +0.30 V in neutral solution, the nanocomposite electrode exhibited linearity up to 11 mM of glucose with a sensitivity of 17.8 μA cm−2 mM−1 and a detection limit of 1.8 μM (S/N = 3). Electroactive ascorbic acid (0.1 mM), uric acid (0.1 mM) and fructose (0.3 mM) invoked only 23%, 14% and 9%, respectively, of the current response obtained for 3 mM glucose. At −0.15 V in neutral solution, the electrode responded linearly to glucose up to 5 mM with a detection limit of 0.16 mM (S/N = 3) and detection sensitivity of ∼18 μA cm−2 mM−1. At this negative potential, ascorbic acid, uric acid, and fructose were not electroactive, therefore, not interfering with glucose sensing. Modification of the nanocomposite electrode with Nafion coating followed by electrodeposition of a second layer of PtPbNPs on the Nafion coated PtPbNP/MWCNT nanocomposite produced a glucose sensor (poised at −0.15 V) with a lower detection limit (7.0 μM at S/N = 3) and comparable sensitivity, selectivity and linearity compared to the PtPbNP/MWCNT nanocomposite. The Nafion coating lowered the detection limit by reducing the background noise, while the second layer of PtPbNPs restored the sensitivity to the level before Nafion coating.  相似文献   

4.
Zhu H  Liang X  Chen J  Li M  Zhu Z 《Talanta》2011,85(3):1592-1597
Gold nanoparticles (GNPs) embedded in a Bucky gel consisting of carbon nanotubes (CNTs) and ionic liquid (IL) show an excellent electrocatalytic activity to glucose oxidation owing to some synergistic effects among GNPs, CNTs and IL. Each component in such a composite has its specific function while there are complicate interactions among them. Based on this strategy, the use of composite as the modified coating allows the fabrication of a novel nonenzymatic glucose electrochemical sensor, which shows a substantial enhancement in detection sensitivity. This paper centers on the influence of several ILs with various anions and cations as well as alkyl branch lengths on the function of sensor. Based on our results, the performance of the sensor is strongly influenced by ILs. A few conclusions can be drawn. Firstly, an imidazolium cation facilitates both the stability of sensor and the efficiencies of GNPs and CNTs, while the alkyl branch lengths have few effects on the performance of sensor. Secondly, a hydrophilic anion is beneficial to the formation of environment where the direct oxidation of glucose takes place. Thirdly, other anions such as BF4 and PF6 do not matter for imidazolium-based IL. Fourthly, non-imidazolium-based IL militates against the dispersion of CNTs and GNPs in Bucky gel, reducing the detection sensitivity to glucose. Of the ILs studied, the best performance for glucose determination is obtained with an IL mainly benefitted by the combination of imidazole and sulfonate.  相似文献   

5.
Platinum nanoparticles (Pt NPs) were deposited onto multi-walled carbon nanotubes (MWNTs) through direct chemical reduction without any other stabilizing agents. Transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS) and cyclic voltammetry were employed to characterize the morphology of the as-prepared nanocomposite (noted as Pt NPs-MWNTs) and further identify the Pt NPs on the surface of MWNTs. The nanocomposite demonstrated the ability to electrocatalyze the oxidation of hydrogen peroxide and substantially raises the response current. A sensitivity of 591.33 μA mM−1 cm−2 was obtained at Pt NPs-MWNTs modified electrode. Thus, we immobilized glucose oxidase (GOD) as a model enzyme on the nanocomposite-based electrode with a thin layer of Nafion to fabricate a glucose biosensor, which showed sensitive and fast response to glucose. The influence of the GOD loading was investigated and the biosensor with an enzyme loading concentration of 10 mg/mL shows optimal performance for glucose detection, that is, a detection limit of 3 μM and a response time of 3 s, respectively.  相似文献   

6.
The bionanocomposite film consisting of glucose oxidase/Pt/functional graphene sheets/chitosan (GOD/Pt/FGS/chitosan) for glucose sensing is described. With the electrocatalytic synergy of FGS and Pt nanoparticles to hydrogen peroxide, a sensitive biosensor with a detection limit of 0.6 μM glucose was achieved. The biosensor also has good reproducibility, long-term stability and negligible interfering signals from ascorbic acid and uric acid comparing with the response to glucose. The large surface area and good electrical conductivity of graphene suggests that graphene is a potential candidate as a sensor material. The hybrid nanocomposite glucose sensor provides new opportunity for clinical diagnosis and point-of-care applications.  相似文献   

7.
Wu L  McIntosh M  Zhang X  Ju H 《Talanta》2007,74(3):387-392
Thionine had strong interaction with carbon nanofiber (CNF) and was used in the non-covalent functionalization of carbon nanofiber for the preparation of stable thionine-CNF nanocomposite with good dispersion. With a simple one-step electrochemical polymerization of thionine-CNF nanocomposite and alcohol oxidase (AOD), a stable poly(thionine)-CNF/AOD biocomposite film was formed on electrode surface. Based on the excellent catalytic activity of the biocomposite film toward reduction of dissolved oxygen, a sensitive ethanol biosensor was proposed. The ethanol biosensor could monitor ethanol ranging from 2.0 to 252 μM with a detection limit of 1.7 μM. It displayed a rapid response, an expanded linear response range as well as excellent reproducibility and stability. The combination of catalytic activity of CNF and the promising feature of the biocomposite with one-step non-manual technique favored the sensitive determination of ethanol with improved analytical capabilities.  相似文献   

8.
In this work, a glassy carbon electrode (GCE) was modified with multiwall carbon nanotubes/ionic liquid/graphene quantum dots (MWCNTs/IL/GQDs) nanocomposite. Then, the nanocomposite was decorated with nickel‐cobalt nanoparticles (Ni?Co NPs), and it was used as a non‐enzymatic glucose sensor. Field emission scanning electron microscopy, X‐ray diffraction spectroscopy, and energy dispersive spectroscopy were employed to prove the electrodeposition of the Ni?Co NPs on the surface of MWCNTs/IL/GQDs/GCE. Also, cyclic voltammetric and amperometric methods were utilized for the investigation of the electrochemical behaviour of the Ni?Co NPs/MWCNTs/IL/GQDs/GCE for glucose oxidation. The novel amperometric sensor displayed two linear ranges from 1.0 to 190.0 μmol L?1 and 190.0 to 4910 μmol L?1 with a low detection limit of 0.3 μmol L?1 as well as fast response time (2 s) and high stability. Also, the sensor showed good selectivity for glucose determination in the presence of ascorbic acid, citric acid, dopamine, uric acid, fructose, and sucrose, as potential interference species. Finally, the performance of the proposed sensor was investigated for the glucose determination in real samples. Ni?Co NPs/MWCNTs/IL/GQDs/GCE showed good sensitivity and excellent selectivity.  相似文献   

9.
Navid Nasirizadeh 《Talanta》2009,80(2):656-661
A highly efficient noradrenalin (NA) biosensor was fabricated on the basis of hematoxylin electrodeposited on a glassy carbon electrode, GCE. The cyclic voltammetric responses of the hematoxylin biosensor at various scan rates, which were obtained in a 0.25 mmol L−1 NA solution, showed the characteristic shape typical of an ECcat process. The kinetic parameters such as electron transfer coefficient, α, the catalytic electron transfer rate constant, k′, and the standard catalytic electron transfer rate constant, k0, for oxidation of NA at the hematoxylin biosensor surface were estimated using cyclic and RDE voltammetry. The peaks of differential pulse voltammetric (DPV) for NA and acetaminophen (AC) oxidation at the hematoxylin biosensor surface were clearly separated from each other when they co-exited in the physiological pH (pH 7.0). It was, therefore, possible to simultaneously determine NA and AC in the samples at a hematoxylin biosensor. Linear calibration curves were obtained for 5.0 × 10−1 to 65.40 μmol L−1 and 65.40-274.20 μmol L−1 of NA, and for 12.00-59.10 μmol L−1 and 59.10-261.70 μmol L−1 of AC. The sensitivities of the biosensor to NA in the absence and presence of AC were found virtually the same, which indicates the fact that the electrocatalytic oxidation processes of NA are independent of AC and, therefore, simultaneous or independent measurements of the two analytes (NA and AC) are possible without any interference. The results of 16 successive measurements show an average voltammetric peak current of 1.13 ± 0.03 μA for an electrolyte solution containing 5.00 μmol L−1 NA. The hematoxylin biosensor has been satisfactorily used for the determination of NA and AC in pharmaceutical formulations. The results obtained, using the biosensor, are in very good agreement with those declared in the label of pharmaceutical inhalation products.  相似文献   

10.
An amperometric biosensor for sensitive and selective detection of glucose has been constructed by using highly dispersed Pt nanoparticles supported on carbon nanotubes (Pt-MWCNTs) as sensing interface. The Pt-MWCNTs were synthesized by using the two-step pyrolysis method. This composite shows good electrocatalytic activity towards the oxidation of glucose in alkaline and thus can be used to selectively detect glucose. We found that detection potential and Nafion amount covered on the Pt-MWCNTs modified glassy carbon electrode had considerable influence on the selectivity for amperometric detection of glucose. Under optimal detection conditions (detection potential of 0.0 V versus SCE and 10 μL 1.5% Nafion), selective detection of glucose in the glucose concentration range of 1.0-26.5 mM (correlation coefficient, >0.999) can be performed. The results demonstrate that the Pt-MWCNTs composite is promising for the fabrication of nonenzymatic glucose sensors.  相似文献   

11.
A novel electrode was developed through electrodepositing gold nanoparticles (GNPs) on overoxidized-polyimidazole (PImox) film modified glassy carbon electrode (GCE). The combination of GNPs and the PImox film endowed the GNPs/PImox/GCE with good biological compatibility, high selectivity and sensitivity and excellent electrochemical catalytic activities towards ascorbic acid (AA), dopamine (DA), uric acid (UA) and tryptophan (Trp). In the fourfold co-existence system, the peak separations between AA–DA, DA–UA and UA–Trp were large up to 186, 165 and 285 mV, respectively. The calibration curves for AA, DA and UA were obtained in the range of 210.0–1010.0 μM, 5.0–268.0 μM and 6.0–486.0 μM with detection limits (S/N = 3) of 2.0 μM, 0.08 μM and 0.5 μM, respectively. Two linear calibrations for Trp were obtained over ranges of 3.0–34.0 μM and 84.0–464.0 μM with detection limit (S/N = 3) of 0.7 μM. In addition, the modified electrode was applied to detect AA, DA, UA and Trp in samples using standard addition method with satisfactory results.  相似文献   

12.
Ming Chen 《Talanta》2009,80(2):815-134
A novel amperometric glucose sensor based on inclusion complex of mono-6-thio-β-cyclodextrin/ferrocene capped on gold nanoparticles (GNPs/CD-Fc) and glucose oxidase (GOD) was described. The inclusion complex of mono-6-thio-β-cyclodextrin/ferrocene capped on gold nanoparticles played an effective role of an electron shuttle and allowed the detection of glucose at 0.25 V (versus SCE), with dramatically reduced interference from easily oxidizable constituents. The sensor (GNPs/CD-Fc/GOD) showed a relatively fast response time (5 s), low detection limit (15 μM, S/N = 3), and high sensitivity (ca. 18.2 mA M−1 cm−2) with a linear range of 0.08-11.5 mM of glucose. The excellent sensitivity was possibly attributed to the presence of the GNPs/CD-Fc film that can provide a convenient electron tunneling between the protein and the electrode. In addition, the biosensor demonstrated high anti-interference ability, stability and natural life. The good stability and natural life can be attributed to the following two aspects: on the one hand, the fabrication process was mild and no damage was made on the enzyme molecule, on the other hand, the GNPs possessed good biocompatibility that could retain the bioactivity of the enzyme molecules immobilized on the electrode.  相似文献   

13.
Urchin-like gold submicrostructures (UGS) were successfully synthesized by a seed-mediated method which is quite facile and does not need any template or surfactant agent. The effect of the added silver seeds on the morphology and size of final products were investigated, and a possible growth mechanism of crystals was proposed. Electrochemical characterization indicated that these UGS have better catalytic activity for the glucose oxidation compared with flower-like gold submicrostructures (FGS), which could be ascribed to its higher surface to volume ratio. An electrochemical nonenzymatic glucose sensor was fabricated simply by casting the UGS and Nafion solution onto glass carbon electrode. This sensor displays a wide linear range from 0.2 to 13.2 mM with a high sensitivity of 16.8 μA mM−1 cm−2, and a detection limit of 10 μM. The unique properties of this sensor, such as fast response and well stability reveal the potential application of the UGS based materials in nonenzymatic detection of glucose.  相似文献   

14.
We utilized CuNiO nanoparticles modified graphene sheets (CuNiO–graphene) to the application of enzymeless glucose sensing. The hydrothermal synthesized CuNiO nanoparticles were successfully assembled on graphene sheets. Distinct from general method, the high quality pristine graphene was produced by chemical vapor deposition (CVD) and bubbling transferred on the electrode. Incorporating the excellent electronic transport of graphene and high electrocatalytic activity of CuNiO nanoparticles, the CuNiO–graphene nanocomposite modified electrode possessed strong electrocatalytic ability toward glucose in alkaline media. The proposed nonenzymatic glucose sensor exhibited wide linear range up to 16 mM (two parts, from 0.05 to 6.9 mM and 6.9–16 mM) and high sensitivity (225.75 μA mM−1 cm−2 and 32.44 μA mM−1 cm−2, respectively). Excellent selectivity and acceptable stability were also achieved. Such an electrode would be attractive to sensor construction for its good properties, simple operation and low expense.  相似文献   

15.
Zhong H  Yuan R  Chai Y  Li W  Zhong X  Zhang Y 《Talanta》2011,85(1):104-111
A new glucose amperometric biosensor, based on electrodeposition of platinum nanoparticles onto the surface of multi-wall carbon nanotube (MWNT)-polyaniline (PANI) nanocomposites, and then immobilizing glucose oxidase (GOD) with covalent interaction and adsorption effect, was constructed in this paper. Firstly, the MWNT-PANI nanocomposites had been synthesized by in situ polymerization and were characterized through transmission electron microscopy (TEM), Fourier transform infrared (FT-IR) spectroscopy, and ultraviolet and visible (UV-vis) absorption spectra. The assembled process of the modified electrode was probed by scanning electron microscopy (SEM) and cyclic voltammetry (CV). Chronoamperometry was used to study the electrochemical performance of the resulting biosensor. The glucose biosensor exhibited a linear calibration curve over the range from 3.0 μM to 8.2 mM, with a detection limit of 1.0 μM and a high sensitivity of 16.1 μA mM−1. The biosensor also showed a short response time (within 5 s). Furthermore, the reproducibility, stability and interferences of the biosensor were also investigated.  相似文献   

16.
Wang W  Zhang TJ  Zhang DW  Li HY  Ma YR  Qi LM  Zhou YL  Zhang XX 《Talanta》2011,84(1):71-77
A novel matrix, gold nanoparticles-bacterial cellulose nanofibers (Au-BC) nanocomposite was developed for enzyme immobilization and biosensor fabrication due to its unique properties such as satisfying biocompatibility, good conductivity and extensive surface area, which were inherited from both gold nanoparticles (AuNPs) and bacterial cellulose nanofibers (BC). Heme proteins such as horseradish peroxidase (HRP), hemoglobin (Hb) and myoglobin (Mb) were successfully immobilized on the surface of Au-BC nanocomposite modified glassy carbon electrode (GCE). The immobilized heme proteins showed electrocatalytic activities to the reduction of H2O2 in the presence of the mediator hydroquinone (HQ), which might be due to the fact that heme proteins retained the near-native secondary structures in the Au-BC nanocomposite which was proved by UV-vis and IR spectra. The response of the developed biosensor to H2O2 was related to the amount of AuNPs in Au-BC nanocomposite, indicating that the AuNPs in BC network played an important role in the biosensor performance. Under the optimum conditions, the biosensor based on HRP exhibited a fast amperometric response (within 1 s) to H2O2, a good linear response over a wide range of concentration from 0.3 μM to 1.00 mM, and a low detection limit of 0.1 μM based on S/N = 3. The high performance of the biosensor made Au-BC nanocomposite superior to other materials as immobilization matrix.  相似文献   

17.
PtRu nanoparticles were supported on multiwall carbon nanotubes (MWNTs), which were further fabricated as an electrode for nonenzymatic glucose sensing. Transmission electron microscope and X‐ray diffraction patterns were used for characterization of the PtRu nanoparticles on MWNTs. Cyclic voltammetry and chronopotentiometry were applied to investigate the performance of the PtRu/MWNTs nanocomposite electrode for nonenzymatic oxidation of glucose. The PtRu/MWNTs electrode shows high electrocatalytic activity towards the oxidation of glucose in 0.1 M NaOH solution and thus can be used to selectively detect glucose. Under the optimal potential (+0.55 V vs. Ag/AgCl), the biosensor effectively performs a selective electrochemical analysis of glucose in the presence of common interferents, such as ascorbic acid (AA), dopamine (DP) and uric acid (UA). Wide linear calibration ranging from 1 mM to 15 mM, high sensitivity of 28.26 μA cm?2 mM?1, low detection limit of 2.5×10?5 M, and fast response time of 10 s were achieved for the detection of glucose at the PtRu/MWNTs electrode.  相似文献   

18.
Tessy Theres Baby 《Talanta》2010,80(5):2016-7814
A new type of amperometric glucose biosensor based on silicon dioxide coated magnetic nanoparticle decorated multiwalled carbon nanotubes (Fe3O4@SiO2/MWNTs) on a glassy carbon electrode (GCE) has been developed. MWNTs have been synthesized by catalytic chemical vapour decomposition (CCVD) of acetylene over rare earth (RE) based AB3 alloy hydride catalyst. The as-grown MWNTs have been purified and further functionlized. Functionalized MWNTs have been decorated with magnetic Fe3O4 nanoparticles which have been uniformly coated with biocompatible SiO2 using a simple chemical reduction method. The characterization of magnetic nanoparticle modified MWNTs have been done by X-ray diffraction (XRD), Fourier transform infra red spectroscopy (FT-IR), scanning electron microscope (SEM), transmission electron microscope (TEM), vibrating sample magnetometer (VSM), energy dispersive X-ray analysis (EDX) and UV-vis spectroscopy. Amperometric biosensor has been fabricated by the deposition of glucose oxidase (GOD) over Nafion-solubilized Fe3O4@SiO2/MWNTs electrode. The resultant bioelectrode retains its biocatalytic activity and offers fast and sensitive glucose quantification. The performance of the biosensor has been studied using cyclic voltammetry and amperometry and the results have been discussed. The fabricated glucose biosensor exhibits a linear response from 1 μM to 30 mM with an excellent detection limit of 800 nM indicating the potential applications in food industries.  相似文献   

19.
Gold nanoshells (GNSs), consisting of a silica core and a thin gold shell, were self-assembled on the surface of 3-aminopropyltrimethoxysilane (APTES) modified indium tin oxide (ITO) electrode. The resulting novel GNSs-coated ITO (GNSs/APTES/ITO) electrode could provide a biocompatible surface for the adsorption of hemoglobin (Hb). The UV-visible (UV-vis) spectra indicated that Hb adsorbed on the GNSs interface retained the native structure. Electrochemical impedance spectra and cyclic voltammetric techniques were employed to evaluate the electrochemical behaviors of Hb, the results demonstrated that GNSs could act as electron tunnels to facilitate electron transfer between Hb and the electrode. Based on the activity of Hb adsorbed on the GNSs/APTES/ITO electrode toward the reduction of hydrogen peroxide, a mediator-free H2O2 biosensor was constructed, which showed a broad linear range from 5 μM to 1 mM with a detection limit of 3.4 μM (S/N = 3). The apparent Michaelis-Menten constant was calculated to be 180 μM, suggesting a high affinity.  相似文献   

20.
A selective and simple biosensor was prepared by immobilizing chitosan/nickelnanoparticles/multi-walled carbon nanotubes biocomposite on the glassy carbon electrode surface for voltammetric quantification of neotame. The properties and morphology of the modified electrode surfaces were characterized by scanning electron microscope (SEM), energy dispersive X-ray analysis (EDX). Electro oxidation of neotame on this modified surface was examined through cyclic voltammetry (CV) and square wave voltammetry (SWV) techniques. The biocomposite modified surface (Chi/NiNPs/MWCNTs/GCE) proposed in this study showed good electrocatalytic activity for neotame with an improved voltammetric peak current at 1.004 V, unlike the bare glassy carbon electrode (GCE) surface and several other modified surfaces. Under optimum conditions, Chi/NiNPs/MWCNTs/GCE gave linear SWV responses at the range of 2 μM ∼50 μM for neotame with 0.84 μM determination limit. This voltammetric sensor was successfully employed for the quantification of neotame on food samples and showed long-term stability, advanced voltammetric behavior, and good repeatability. Selective, accurate, and precise determination of neotame highlight the importance of this electrode in monitoring the control of food additives and ensures attract a great deal of attention.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号