首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Filik H  Giray D  Ceylan B  Apak R 《Talanta》2011,85(4):1818-1824
A novel fiber optic spectrophotometric method for nitrite determination in different samples is suggested, based on the reaction of nitrite with Safranin O in acidic medium to form a diazo-safranin, which is subsequently coupled with pyrogallol in alkaline medium to form a highly stable, red azo dye, followed by cloud point extraction (CPE) using a mixed micelle of a nonionic surfactant, Triton X-114, with an anionic surfactant, sodium dodecyl sulphate (SDS). The reaction and extraction conditions (e.g., acidity for diazotization and alkalinity for pyrogallol coupling, and other reagent concentrations, time, and tolerance to other ions) were optimized. Linearity was obeyed in a concentration range up to 230 μg L−1, and the detection limit of the method is 0.5 μg L−1 of nitrite ion. The molar absorptivity for nitrite of the Safranin-diazonium salt (?610 nm = 4 × 103 L mol−1 cm−1) existing in literature was greatly enhanced by pyrogallol coupling and CPE enrichment (?592 nm = 1.39 × 105 L mol−1 cm−1). The method was applied to the determination of nitrite in tap water, lake water and milk samples with an optimal preconcentration factor of 20.  相似文献   

2.
A pyrimethanil-imprinted polymer (P1) was prepared by iniferter-mediated photografting a mixture of methacrylic acid and ethylene dimethacrylate onto homemade near-monodispersed chloromethylated polydivinylbenzene beads. The chromatographic behaviour of a column packed with these imprinted beads was compared with another column packed with irregular particles obtained by grinding a bulk pyrimethanil-imprinted polymer (P2). The comparison was made using the kinetic model of non-linear chromatography, studying the elution of the template and of two related substances, cyprodinil and mepanipyrim. Extension of the region of linearity, capacity factors for the template and the related substances, column selectivity, binding site heterogeneity, apparent affinity constant (K) and lumped kinetic association (ka) and dissociation rate constant (kd) were studied during a large interval of solute concentration, ranging between 1 and 2000 μg/ml. From the experimental results obtained, in the linearity region of solute concentration column selectivity and binding site heterogeneity remained essentially the same for the two columns, while column capacity (at 20 μg/ml, P1 = 23.1, P2 = 11.5), K (at 20 μg/ml, P1 = 8.3 × 106 M−1, P2 = 2.5 × 106 M−1) and ka (at 20 μg/ml, P1 = 3.5 μM−1 s−1, P2 = 0.47 μM−1 s−1) significantly increased and kd (at 20 μg/ml, P1 = 0.42 s−1, P2 = 0.67 s−1) decreased for the column packed with the imprinted beads. These results are consistent with an influence of the polymerisation method on the morphology of the resulting polymer and not on the molecular recognition properties due to the molecular imprinting process.  相似文献   

3.
The development of a highly sensitive amperometric sensor for nitrite using a glassy carbon electrode modified with alternated layers of iron(III) tetra-(N-methyl-4-pyridyl)-porphyrin (FeT4MPyP) and cobalt(II) tetrasulfonated phthalocyanine (CoTSPc) is described. The modified electrode showed an excellent catalytic activity and stability for the nitrite oxidation decreasing the peak potentials about 200 mV toward less positive values and presenting much higher peak currents than those obtained on the bare GC electrode. A linear response range of 0.2-8.6 μmol l−1, with a sensitivity of 0.37 μA l μmol−1 and detection limit of 0.04 μmol l−1 were obtained with this sensor. The repeatability of the proposed sensor, evaluated in term of relative standard deviation, was verified to be 1.4% for 10 measurements of 0.2 μmol l−1 nitrite solution. Interference caused by common ions has been investigated in simulated mixtures containing high concentration level of interfering ions and the sensor was found to be tolerant against these ions. The developed sensor was applied for the nitrite determination in water samples and the results were in agreement with those obtained by a comparative method described in the literature. The average recovery for these samples was 100.1 (±0.7)%.  相似文献   

4.
Feres MA  Reis BF 《Talanta》2005,68(2):422-428
In this work, a downsized flow set up designed based on multicommutation concept for photometric determination of iron(II)/iron(III) and nitrite/nitrate is surface water is described. The flow system network comprised a set of three-way solenoid valves, reaction coil and a double-channel flow cell, which were nested in order to obtain a compact and small-size instrument. To accomplish the downsizing requirement light source (LED) and radiation detection (phototransistor) were coupled to the flow cell. In order to demonstrated the effectiveness of the system, the photometer methods based on Griess reaction and 1-10-phenantroline for nitrite and iron(II) determination, respectively, were selected. Under computer control the set up provided facilities to handle four reagent solutions employing a single pumping channel, thus permitting also the determination of nitrate and iron(III) after its reduction to nitrite and to iron(II), respectively. The overall system performance was demonstrated working several days running standard solution, no significant variation of base line, linear response range and slop (less than 1%) were observed. The usefulness of the downsized system was ascertained by analyzing a set of surface water. Aiming to access the accuracy sample were also analyzed employing reference procedures and no significant difference at 95% confidence level were observed for the four analytes. Other profitable features such as analytical throughput of 40 determination per hour; relative standard deviation of 1%; linear response range between 50 and 300 μg l−1 for nitrite and nitrate, 0.5-6.0 mg l−1 iron(II) and iron(III); low reagent consumption 75 μg for nitrate/nitrite and 0.6 mg for iron(II)/iron(III) per determination; and 2.4 ml waste generation per determination were also achieved.  相似文献   

5.
A new tetrazolium-triiodomercurate-modified carbon paste electrode has been described for the sensitive and selective determination of mercury. The electrode shows a stable, near-Nernstian response for 1×10−3 to 6×10−6 M [HgI3] at 25 °C over the pH range of 4.0-9.0, with an anionic slope of 55.5±0.4 mV. The lower detection limit is 4×10−6 M with a fast response time of 30-50 s. Selectivity coefficients of a number of interfering anions and iodo complexes of some metal ions have been estimated. The interference from many of the investigated ions is negligible. The determination of 1-200 μg/ml of mercury in aqueous solutions shows an average recovery of 98.5% and a mean relative standard deviation of 1.6% at 50.0 μg/ml. The direct determination of mercury in spiked wastewater, metal amalgams and dental alloy gave results that compare favorably with those obtained by the cold vapor atomic absorption spectrometric method. Potentiometric titration of mercury and phenylmercury acetate with standard potassium iodide has been monitored using the developed triiodomercurate-carbon paste electrode (CPE) as an end point indicator electrode.  相似文献   

6.
7.
Pt nanoclusters were deposited in polypyrrole (PPy) nanowires by cyclic voltammetry method, fabricating a PPy-Pt nanocomposite on glassy carbon electrode (PPy-Pt/GCE). The electrocatalytic reduction of nitrite at PPy-Pt/GCE has been investigated using 0.5 M H2SO4 solution. The sensor exhibited excellent electrocatalytic activity toward nitrite reduction. In acidic medium, the cyclic voltammetry at 20 mV s− 1 gave a nitrite reduction peak at − 0.124 V with 0.566 μA μM− 1 current sensitivity in the range of 5.0 × 10− 7-1.0 × 10− 3 M. The detection limit was 1.5 × 10− 7 M (s/n = 3). The proposed method was successfully applied in the detection of nitrite in real water samples and obtained satisfactory results. The PPy-Pt composite modified electrode had good storage stability, reproducibility and anti-interference ability.  相似文献   

8.
A polyaniline (PANI)/carbon nanotubes (CNTs) composite modified electrode was fabricated by galvanostatic electropolymerization of aniline on multi-walled carbon nanotubes (MWNTs)-modified gold electrode. The electrode thus prepared exhibits enhanced electrocatalytic behavior to the reduction of nitrite and facilitates the detection of nitrite at an applied potential of 0.0 V. Although the amperometric responses toward nitrite at MWNTs/gold and PANI/gold electrodes have also been observed in the experiments, these responses are far less than that obtained at PANI/MWNTs/gold electrode. The effects of electropolymerization time, MWNTs concentration and pH value of the detection solution on the current response of the composite modified electrode toward sodium nitrite, were investigated and discussed. A linear range from 5.0 × 10−6 to 1.5 × 10−2 M for the detection of sodium nitrite has been observed at the PANI/MWNTs modified electrode with a sensitivity of 719.2 mA M−1 cm−2 and a detection limit of 1.0 μM based on a signal-to-noise ratio of 3.  相似文献   

9.
The preparation and electrochemical characterization of a carbon paste electrode modified with layered birnessite-type manganese oxide for use as a sodium sensor is described. The effects of powder synthesis process (sol-gel and redox precipitation) for birnessite on the electrochemical activity of the sensor was investigated by cyclic voltammetry. The carbon paste electrode modified with birnessite-type manganese oxide that was synthesized by the sol-gel method showed a best electrochemical for sodium ions. The detection is based on the measurement of anodic current generated by oxidation of Mn(III) to Mn(IV) at the surface of the electrode and consequently the sodium ions extraction into the birnessite structure. The best voltammetric response was obtained for an electrode composition of 15% (w/w) birnessite oxide in the paste, a TRIS buffer solution of pH 8.0 and a scan rate of 50 mV s−1. A sensitive linear voltammetric response for sodium ions was obtained in the concentration range of 7.89 × 10−5 to 3.49 × 10−4 mol L−1 with a slope of 37.5 μA L mmol−1 and a detection limit (3σ/slope) of 3.43 × 10−5 mol L−1 using cyclic voltammetry. Under the working conditions, the proposed method was successfully applied to determination of sodium ions in urine samples.  相似文献   

10.
Microwave energy has been novelty applied to speed up a tetramethylammonium hydroxide (TMAH) alkaline digestion of seaweed samples and to assist distillation of iodine from seaweed alkaline digests. Iodide in the alkaline digests from seaweed and distilled iodine, reduced back to iodine in a hydroxylamine hydrochloride solution, was determined by a catalytic spectrophotometric method based on the catalytic effect of iodide on the oxidation of As(III) by Ce(IV) in H2SO4/HCl medium (Sandell-Kolthoff reaction). The determination of iodide was directly performed in the alkaline digests, while total iodine was assessed by analyzing the hydroxylamine hydrochloride solution after the distillation process. Microwave-assisted alkaline digestion was performed using 7.5 mL of TMAH and irradiating samples at 670 W for two 5.5 min steps. Microwave-assisted distillation was carried out using 4.0 mL of the alkaline digest and 3 mL of a 2.2 M hydrochloric acid and 0.05% (m/v) sodium nitrite solution, with a microwave power at 670 W for two 90 s steps. The distillate (iodine vapor) was bubbled in 10 mL of a 500 μg mL−1 hydroxylamine hydrochloride solution (accepting solution). The linear calibration ranges were 0.30-20.0 and 0.40-20.0 μg L−1 for iodide determination and total iodine determination, respectively. The limit of detection was 9.2 μg g−1 for iodide and 28.5 μg g−1 for total iodine. Repeatability of the overall procedures, expressed as R.S.D. for 11 determinations, was 2.6% for 196.3 μg g−1 of iodide measured after microwave-assisted alkaline digestion, and 5.8% for 954.3 μg g−1 of total iodine by microwave-assisted alkaline digestion followed by microwave-assisted distillation. Finally, accuracy of the methods was assessed by analyzing the NIST-09 (Sargasso) certified reference material and the methods were applied to the determination of iodide and total iodine in different Atlantic edible seaweed samples with satisfactory results.  相似文献   

11.
A screening method was developed to discriminate among water samples contaminated or uncontaminated with N-nitrosamines in order to reduce the use of expensive instruments such as chromatographs. The system is based on the preconcentration of the analytes onto a sorbent column, elution and derivatization to form nitrite, then formation of a coloured product (Griess reaction) and photometric detection. The limit of detection achieved for 100 ml of sample volume was 0.2 μg/l and the sample frequency 3 h−1. The reliability of the proposed method of the N-nitrosamines was established at five concentrations (between 0.5 and 3 times the limit of detection). For a level concentration of 0.6 μg/l (three times the limit of detection), the percentage of false negatives is 0%. The method was applied to the screening of several water samples (river, pond, well, tap and waste) with a positive response only for waste water samples.  相似文献   

12.
This work describes an arsenic speciation analysis in aqueous effluent from a shale industrial plant using liquid chromatography coupled to inductively coupled plasma mass spectrometry (LC–ICP–MS). Arsenic species have been separated through an anion-exchange column and several parameters investigated, such as retention time, pH, flow rate and concentration of the mobile phase (ammonium carbonate), chloride interference and column conditioning time. The best conditions have been found by fixing the pH of the mobile phase at 8.7. Keeping the mobile phase flow rate at 1.5 ml min− 1, arsenic species were separated by varying the concentration of the mobile phase and the time of elution, as follow: 1.5 mmol l− 1 for 10 min, 12 mmol l− 1 for 10 min and 20 mmol l− 1 for 10 min, respectively. Up to 13 As species present in the samples were separated under these conditions and the following species could be identified and quantified: arsenite [As(III)], dimethylarsinic acid (DMA), monomethylarsonic acid (MMA) and arsenate [As(V)]. The limits of detection of the LC–ICP–MS method were 0.02, 0.06, 0.04 and 0.10 μg l− 1 of As(III), DMA, MMA, and As(V), respectively. The concentration of these species in the samples were from 3.7 to 6.4 μg l− 1, 6.9 to 13.2 μg l− 1, 100 to 142 μg l− 1 and 808 to 1363 μg l− 1 for As(III), DMA, MMA and As(V), respectively. The accuracy, evaluated by recovery tests, varied from 94 to 105% and the precision, evaluated by the relative standard deviation was typically lower than 10%.  相似文献   

13.
Jun Kato  Michihito Chiba 《Talanta》2009,79(4):1154-1160
Trace amounts of l-cysteine can function as a trigger, i.e., reaction initiator, in the autocatalytic sodium sulfite/hydrogen peroxide reaction system. Rapidly changing of pH after induction time is visually confirmed by color changing of bromothymol blue in this autocatalytic reaction. Based on this finding, μg L−1 levels of l-cysteine were measured over time using the autocatalytic reaction system. The determination range using the above method was 5.0 × 10−8-2.5 × 10−6 M, the detection limit (3σ) was 1.8 × 10−8 M (1.94 μg L−1), and the relative standard deviation was 2.41% at an l-cysteine concentration of 5 × 10−7 M (n = 5). This method was also applied to length detection-flow injection analysis. The determination range for the flow injection analysis was 2.0 × 10−7-1.0 × 10−5 M. The detection limit (3σ) was 1.4 × 10−7 M (17.0 μg L−1), and the relative standard deviation was 0.91% at an initial l-cysteine concentration of 10−6 M (n = 5).  相似文献   

14.
A high sensitive flow-injection chemiluminescence method for determination of calf thymus DNA and herring sperm DNA has been developed. The method is based on the chemiluminescence reaction of Rhodamine B-cerium(IV)-thermally denatured DNAs in sulfuric acid media. The proposed procedure allows quantitation of DNAs in the range 2.6×10−5 to 0.26 μg ml−1 for calf thymus DNA and 5.0×10−8 to 5.0×10−5 μg ml−1 for herring sperm DNA with correlation coefficients 0.9998 and 0.9996 (both n=11), respectively. The detection limits (3σ) are 6.5×10−6 μg ml−1 for calf thymus DNA and 4.3×10−8 μg ml−1 for herring sperm DNA. The possible mechanism of chemiluminescence in the system is discussed.  相似文献   

15.
An analytical procedure with improved sensitivity was developed for cyanide determination in natural waters, exploiting the reaction with the complex of Cu(I) with 2,2′-biquinoline 4,4′-dicarboxylic acid (BCA). The flow system was based on the multi-pumping approach and long pathlength spectrophotometry with a flow cell based on a Teflon AF 2400® liquid core waveguide was exploited to increase sensitivity. A linear response was achieved from 5 to 200 μg L−1, with coefficient of variation of 1.5% (n = 10). The detection limit and the sampling rate were 2 μg L−1 (99.7% confidence level), and 22 h−1, respectively. Per determination, 48 ng of Cu(II), 5 μg of ascorbic acid and 0.9 μg of BCA were consumed. As high as 100 mg L−1 thiocyanate, nitrite or sulfite did not affect cyanide determination. Sulfide did not interfere at concentrations lower than 40 and 200 μg L−1 before or after sample pretreatment with hydrogen peroxide. The results for natural waters samples agreed with those obtained by a fluorimetric flow-based procedure at the 95% confidence level. The proposed procedure is then a reliable, fast and environmentally friendly alternative for cyanide determination in natural waters.  相似文献   

16.
This work reports on the electrooxidation of nitrite using Co(II), Fe(II) and Mn(III) tetrakis (benzylmercapto) and tetrakis (dodecylmercapto) phthalocyanines electrodeposited onto a gold electrode. Good catalytic activity (in terms of lowering overpotential) was obtained for these molecules when compared to previously reported MPc catalysts. The catalytic current was found to vary linearly with nitrite concentration in the range employed in this work (0.1-1 mM) and high sensitivities ranging from 6.9 to 9.9 μA mM−1 were observed for all the modified electrodes.  相似文献   

17.
A simple and robust on-line sequential insertion system coupled with hydride generation atomic absorption spectrometry (HG-AAS) was developed, for selective As(III) and total inorganic arsenic determination without pre-reduction step. The proposed manifold, which is employing an integrated reaction chamber/gas-liquid separator (RC-GLS), is characterized by the ability of the successful managing of variable sample volumes (up to 25 ml), in order to achieve high sensitivity. Arsine is able to be selectively generated either from inorganic As(III) or from total arsenic, using different concentrations of HCl and NaBH4 solutions. For 8 ml sample volume consumption, the sampling frequency is 40 h−1. The detection limit is cL = 0.1 and 0.06 μg l−1 for As(III) and total arsenic, respectively. The precision (relative standard deviation) at 2.0 μg l−1 (n = 10) level is sr = 2.9 and 3.1% for As(III) and total arsenic, respectively. The performance of the proposed method was evaluated by analyzing the certified reference material NIST CRM 1643d and spiked water samples with various concentration ratios of As(III) to As(V). The method was applied for arsenic speciation in natural waters samples.  相似文献   

18.
A flow-batch system was developed for the determination of Fe(III) in estuarine waters with high variability in salinity. The method is based on the catalytic effect of iron(III) on the oxidation rate of N,N-dimethyl-p-phenylenediammonium dichloride (DmPD) by hydrogen peroxide and the formed product is spectrophotometrically monitored at 554 nm. A controlled addition of sodium chloride to every assayed sample is accomplished for in-line individual salinity matching.The proposed system processes about 30 samples h−1 and yields reproducible results. Relative standard deviations were estimated as <1.5% after 10 injections of typical samples (10.0-50.0 μg l−1 Fe; ca. 0.5 mol l−1 Cl). Synthetic samples (15.0 μg l−1 Fe; 0.25-1.0 mol l−1 NaCl) were efficiently processed, and no significant differences in results were found at a probability level of 99.7%. The method works for the full range of salinities. Only 120 μg DmPD are consumed per determination. The analytical curve is linear up to about 60 μg l−1 Fe (r>0.999; n=5) and the detection limit is 5 μg l−1 Fe. Results are in agreement with graphite furnace atomic absorption spectrometry.  相似文献   

19.
Imipenem shows a fast chemical conversion to a more stable imin form (identical to that of biochemical dehydropeptidase degradation) in aqueous solutions and stabilizing agents used avoid its electrochemical study and determination.The aim of this work is the proposal of urea as stabilizing agent which allows the electrochemical study of imipenem and the proposal of electrochemical methods for the determination of imipenem and its primary metabolite (M1) in human urine samples. Electrochemical studies were realized in phosphate buffer solutions over pH range 1.5-8.0 using differential-pulse polarography, DC-tast polarography, cyclic voltammetry and adsorptive stripping voltammetry. In acidic media, a non-reversible diffusion-controlled reduction involving a two steps mechanism which involves one electron and one proton in the first step and two electrons and two protons in the second step occurs and the mechanism for the reduction was suggested.A differential-pulse polarographic method for the determination of imipenem in the concentration range 3.2 × 10−6 to 2 × 10−5 M (0.95-3.4 mg/L) and its primary metabolite in the concentration range 1.4 × 10−6 to 10−4 M (0.43-26.1 mg/L) with detection limits of 9.6 × 10−7 M (0.28 μg/L imipenem) and 4.3 × 10−7 M (0.14 μg/L M1) was proposed. Also, a method based on controlled adsorptive pre-concentration of imipenem on the hanging mercury drop electrode followed by voltammetric measure, allows imipenem determination in the concentration range 1.8 × 10−8 to 1.2 × 10−6 M (5.42-347 μg/L) with a detection limit of 5.4 × 10−9 M (1.63 μg/L). The proposed methods have been used for the direct determination of the analytes in a pharmaceutical formulation and human urine.  相似文献   

20.
Point-of-care platforms can provide fast responses, decrease the overall cost of the treatment, allow for in-home determinations with or without a trained specialist, and improve the success of the treatment. This is especially true for microfluidic paper-based analytical devices (μPAD), which can enable the development of highly efficient and versatile analytical tools with applications in a variety of biomedical fields. The objective of this work was the development of μPADs to identify and quantify levels of nitrite in saliva, which has been proposed as a potential marker of periodontitis. The devices were fabricated by wax printing and allowed the detection of nitrite by a colorimetric reaction based on a modified version of the Griess reaction. The presented modifications, along with the implementation of a paper-based platform, address many of the common drawbacks (color development, stability, etc.) associated with the Griess reaction and are supported by results related to the design, characterization, and application of the proposed devices. Under the optimized conditions, the proposed devices enable the determination of nitrite in the 10–1000 μmol L−1 range with a limit of detection of 10 μmol L−1 and a sensitivity of 47.5 AU [log (μmol L−1)]−1. In order to demonstrate the potential impact of this technology in the healthcare industry, the devices were applied to the analysis of a series of real samples, covering the relevant clinical range.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号