首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The present investigation is the first part of an initiative to prepare a regional map of the natural abundance of selenium in various areas of Brazil, based on the analysis of bean and soil samples. Continuous-flow hydride generation electrothermal atomic absorption spectrometry (HG-ET AAS) with in situ trapping on an iridium-coated graphite tube has been chosen because of the high sensitivity and relative simplicity. The microwave-assisted acid digestion for bean and soil samples was tested for complete recovery of inorganic and organic selenium compounds (selenomethionine). The reduction of Se(VI) to Se(IV) was optimized in order to guarantee that there is no back-oxidation, which is of importance when digested samples are not analyzed immediately after the reduction step. The limits of detection and quantification of the method were 30 ng L−1 Se and 101 ng L−1 Se, respectively, corresponding to about 3 ng g−1 and 10 ng g−1, respectively, in the solid samples, considering a typical dilution factor of 100 for the digestion process. The results obtained for two certified food reference materials (CRM), soybean and rice, and for a soil and sediment CRM confirmed the validity of the investigated method. The selenium content found in a number of selected bean samples varied between 5.5 ± 0.4 ng g−1 and 1726 ± 55 ng g−1, and that in soil samples varied between 113 ± 6.5 ng g−1 and 1692 ± 21 ng g−1.  相似文献   

2.
Hg concentrations in seawater are usually too low to allow direct (without pre-concentration and removal of salt matrix) measurement of its isotope ratios with multicollector-inductively coupled plasma mass spectrometry (MC-ICP-MS). Therefore, a new method for the pre-concentration of Hg from large volumes of seawater was developed. The final method allows for relatively fast (about 2.5 L h−1) and quantitative pre-concentration of Hg from seawater samples with an average Hg recovery of 98 ± 6%. Using this newly developed method we determined Hg isotope ratios in seawater. Reference seawater samples were compared to samples potentially impacted by anthropogenic activity. The results show negative mass dependent fractionation relative to the NIST 3133 Hg standard with δ202Hg values in the range from −0.50‰ to −1.50‰. In addition, positive mass independent fractionation of 200Hg was observed for samples from reference sites, while impacted sites did not show significant Δ200Hg values. Although the influence of the impacted sediments is limited to the seawater and particulate matter in very close proximity to the sediment, this observation may raise the possibility of using Δ200Hg to distinguish between samples from impacted and reference sites.  相似文献   

3.
A microwave-assisted persulfate oxidation method followed by ion chromatographic determination of nitrate was developed for total nitrogen determination in atmospheric wet and dry deposition samples. Various operating parameters such as oxidation reagent concentrations, microwave power, and extraction time were optimized to maximize the conversion of total nitrogen to nitrate for subsequent chemical analysis. Under optimized conditions, 0.012 M K2S2O8 and 0.024 M NaOH were found to be necessary for complete digestion of wet and dry deposition samples at 400 W for 7 min using microwave. The optimized extraction method was then validated by testing different forms of organic nitrogen loaded to pre-baked filter substrates and NIST SRM 1648 (urban particulate matter), and satisfactory results were obtained. In the case of wet deposition samples, standard addition experiments were performed. The suitability of the method for real-world application was assessed by analyzing a number of wet and dry deposition samples collected in Singapore during the period of March-April 2007. The organic nitrogen content was 15% (wet) and 30% (dry) of the total nitrogen. During the study period, the estimated wet fluxes for nitrate (NO3), ammonium (NH4+), organic nitrogen (ON), and total nitrogen (TN) were 16.1 ± 6.5 kg ha−1 year−1, 11.5 ± 5.7 kg ha−1 year−1, 3.8 ± 1.5 kg ha−1 year−1and 31.5 ± 13.2 kg ha−1 year−1, respectively, while the dry fluxes were 2.5 ± 0.8 kg ha−1 year−1, 1.4 ± 0.9 kg ha−1 year−1, 2.3 ± 1.4 kg ha−1 year−1 and 7.5 ± 2.6 kg ha−1 year−1, respectively.  相似文献   

4.
A surfactant-sensitized spectrophotometric method for determination of trace orthophosphate has been developed using anion surfactant (Ultrawet 60 L) with molybdate and malachite green in low acidic medium (pHT 1.0). The method detection limit (3 × standard deviation of blank, n = 10) was 8 nM and the calibration curve was linear over a range of 10-400 nM (r2 = 0.997). The molar absorptivity was 1.26 × 105 L mol−1 cm−1 at 600 nm with the background correction at 530 nm. The precision of method was 3.4% at 50 nM and 2.4% at 100 nM orthophosphate (n = 10). The hydrolysis of eight organic phosphorus and polyphosphate compounds was less than 2% of the total phosphorus present (5-10 μM). This method showed less arsenate interference than previous methods, with only 3% even in the presence of orthophosphate in the samples. No interference of silicate up to 40 μM was observed. Background anions (in an order of SO42− > NO3 > Cl) have greater effects than cations (Ca2+ > Mg2+ > Na+) on the reagent blank and the molar absorptivity of the color product.  相似文献   

5.
A new technique for the determination of suspended particulate trace metals (P-metals >0.2 μm), such as Co, Ni, Cu, Zn, Cd and Pb, in open ocean seawater has been developed by using microwave digestion coupled with flow injection inductively coupled plasma mass spectrometry (FI-ICP-MS). Suspended particulate matter (SPM) was collected from 500 mL of seawater on a Nuclepore filter (0.2 μm) using a closed filtration system. Both the SPM and filter were completely dissolved by microwave digestion. Reagents for the digestion were evaporated using a clean evaporation system, and the metals were redissolved in 0.8 M HNO3. The solution was diluted with buffer solution to give pH 5.0 and the metals were determined by FI-ICP-MS using a chelating adsorbent of 8-hydroxyquinoline immobilized on fluorinated metal alkoxide glass (MAF-8HQ). The procedure blanks with a filter were found to be 0.048 ± 0.008, 10.3 ± 0.3, 0.27 ± 0.05, 3.3 ± 1.8, 0.02 ± 0.03 and 0.85 ± 0.09 ng L−1 for Co, Ni, Cu, Zn, Cd and Pb, respectively (n = 14). Detection limits defined as 3 times the standard deviation of the blanks were 0.023, 0.90, 0.14, 5.3, 0.078 and 0.28 ng L−1 for Co, Ni, Cu, Zn, Cd and Pb, respectively. Accuracy was evaluated using certified reference materials of chlorella (NES CRM No. 3) and marine sediment (HISS-1). The method was applied to the determination of vertical distributions for P-Co, Ni, Cu, Zn, Cd and Pb in the Western North Pacific.  相似文献   

6.
E.K. Janghel  V.K. Gupta  J.K. Rai 《Talanta》2007,72(3):1013-1016
A new simple and sensitive analytical spectrophotometric method is developed for the determination of ascorbic acid reduces methyl viologen to form a stable blue coloured free radical ion. This method has a sensitivity and lower limit detection of 0.1 μg ml−1 of ascorbic acid (0.1 ppm) which is comparable to the flow injection analysis reported earlier. Beer's law is obeyed over the concentration range of 1.0-10 μg ml−1 of ascorbic acid per 10 ml of the final solution (0.1-1.0 μg ml−1) at 600 nm. The molar absorptivity and Sandell's sensitivity were found to be 1.5 × 105 ± 100 l mol−1 cm−1 and 0.001 μg cm−2, respectively. The method has been applied to the determination of ascorbic acid in food, pharmaceuticals and biological samples.  相似文献   

7.
On-site colorimetric methods are a valuable, cost-effective tool to assess the nature and extent of contamination in remediated sites and to enable on-site screening for police criminology laboratories. The existing colorimetric method for cyclotrimethylenetrinitramine (RDX) based on a Griess reaction suffers from the non-quantitative reduction to nitrite and from the unstable character of HNO2 in acidic medium. Thus we propose a novel spectrophotometric RDX assay in explosive mixtures and residues, based on (Zn + HCl) reduction of RDX in a microwave oven, followed by neutralization of the reduction products to ammonia and low molecular-weight amines, and Berthelot reaction of these amine-compounds with phenol and hypochlorite in alkaline medium to give an intensely blue indophenol dye absorbing at 631 nm. The molar absorptivity and limit of detection (LOD) for RDX were (1.08 ± 0.04) × 104 L mol−1 cm−1 and 0.18 mg L−1, respectively. Application of the method to synthetic mixture solutions of RDX and trinitrotoluene (TNT) at varying proportions showed that there was minimal interference from TNT (which could be compensated for by dicyclohexylamine colorimetry), since the Berthelot reaction was essentially non-responsive to m-substituted anilines derived from TNT upon (Zn + HCl) reduction. The proposed method was successfully applied to military-purpose explosive mixtures of (RDX + inert matter) such as Comp A5, Comp C4, and Hexal P30, and to (RDX + TNT) mixtures such as Comp B. The molar absorptivity of RDX was much higher than that of either ammonium or nitrate; RDX could be effectively separated from ammonium and nitrate in soil mixtures, based on solubility differences. The Berthelot method for RDX was statistically validated using Comp B mixtures against standard HPLC equipped with a Hypersil C-18 column with (40% MeOH-60% H2O) mobile phase, and against gas chromatography-thermal energy analysis (GC-TEA) system.  相似文献   

8.
A robust, accurate and sensitive analytical procedure for the determination of Se in plant and peat samples by hydride generation-atomic fluorescence spectrometry (HG-AFS) was developed. Aliquots (200 mg) of dried samples were digested with 3 mL nitric acid and 0.5 mL hydrogen peroxide in closed, pressurized PTFE vessels in a microwave oven at 220 °C. Addition of HBF4 or HF to the digestion mixture was not required because experiments demonstrated that Se was not hosted in the silicate fraction of the investigated sample matrices. Selenium(VI) was directly reduced to Se(IV) in the undiluted digestion solutions after addition of 3.8 mL of 4 M HCl in a microwave oven at 103 °C for 3 min. Other reduction reagents, such as hydroxylamine hydrochloride or urea, were not necessary to cope with potential interferences from nitrogen oxides that could hamper the reliable determination of Se by HG-AFS. Optimum hydride generation of Se was achieved by using 0.9% NaBH4 and 4.5 M HCl. A solution detection limit of 11 ng L−1 was obtained under the optimized experimental conditions which corresponds to a method detection limit of 2.8 ng g−1 in solid peat and plant materials. The precision of replicate measurements was better than 3% at Se concentrations of 50 ng L−1. The analytical procedure was critically evaluated by analysing two certified plant reference materials (SRM 1515 Apple Leaves and SRM 1547 Peach Leaves) as well as three peat reference materials. Excellent agreement between the experimental values ranging from 50 ng g−1 to ∼2 μg g−1 and the certified concentrations was obtained.  相似文献   

9.
A simple and fast analytical procedure has been developed for the determination of As, Sb, Se, Te and Bi in milk samples by hydride generation atomic fluorescence spectrometry (HG-AFS). Samples were treated with aqua regia for 10 min in an ultrasound water bath and pre-reduced with KBr for total Se and Te determination or with KI and ascorbic acid for total As and Sb, the determination of Bi being possible in all with or without pre-reduction. Slurries of samples, in the presence of antifoam A, were treated with NaBH4 in HCl medium to obtain the corresponding hydrides, and AFS measurements were processed in front of external calibrations prepared and measured in the same way as samples. Results obtained by the developed procedure compare well with those found after microwave-assisted complete digestion of samples. The proposed method is simple and fast, and only 1 ml of milk is needed. The values obtained for detection limit are 2.5, 1.6, 3, 6 and 7 ng l−1 for As, Sb, Se, Te and Bi respectively in the diluted samples, with average relative standard deviation values of 3.8, 3.1, 1.9, 6.4 and 1.2% for three independent analysis of a series of commercially available samples of different origin. Data found in Spanish market samples varied from 3.2±0.3 to 11.3±0.2 ng g−1 As, from 3.1±0.2 to 11.6±0.4 ng g−1 Sb, from 10.7±0.5 to 25.5±0.4 ng g−1 Se, from 0.9±0.2 to 9.4±0.6 ng g−1 Te and from 11.5±0.1 to 27.7±0.4 ng g−1 Bi.  相似文献   

10.
The use of a permeation liquid membrane system for the preconcentration and separation of nickel in natural and sea waters and subsequent determination by atomic absorption spectroscopy is presented. 2-Hydroxybenzaldehyde N-ethylthiosemi-carbazone (2-HBET) in toluene is used as the active component of the liquid membrane. A study strategy based on a simplex design has been followed. Several chemical and physical parameters were optimized. Maximum permeation coefficient was obtained at a feed solution pH of 9.4, 0.3 mol l−1 of HNO3 in the stripping solution and 1.66 mmol l−1 of 2-HBTE in toluene as carrier. The precision of the method was 4.7% at 95% significance level and a detection limit of 0.012 μg l−1 of nickel was achieved. The preconcentration procedure showed a linear response within the studied concentration range from 3 to 500 μg l−1 of Ni in the feed solution. The method was validated with different spiked synthetic seawater and certified reference water samples: TMDA-62 and LGC 6016, without matrix interferences and showing good concordance with the certified values, being the relative errors −5.9% and −2.2%, respectively. Under optimal conditions, the average preconcentration yield for real seawater samples was 98 ± 5%, with a nickel preconcentration factor of 20.83 and metal concentrations ranging between 2.8 and 5.4 μg l−1.  相似文献   

11.
A method for estimation of uranium in seawater by using steady state laser flourimetry is described. Uranium present in seawater, in concentration of approximately 3 ng ml−1 was estimated without prior separation of matrix. Quenching effect of major ions (Cl, Na+, SO4, Mg+, Ca+, K+, HCO3, Br) present in seawater on fluorescence intensity of uranium was studied. The concentration of phosphoric acid required for maximum enhancement of fluorescence intensity was optimized and was found to be 5%. Similarly the volume of concentrated nitric acid required to eliminate the quenching effect of chloride and bromide completely from 5 ml of seawater were optimized and was found to be 3 ml. A simple equation was derived using steady state fluorescence correction method and was used for calculation of uranium concentration in seawater samples. The method has a precesion of 1% (1 s, n = 3). The values obtained from laser fluorimetry were validated by analyzing the same samples by linear sweep adsorptive stripping voltametry (LSASV) of the uranium-chloranilic acid (2,5-dichloro-3,6-dihydroxy-1,4-benzoquinone) complex. Both the values are well in agreement.  相似文献   

12.
Ion exclusion chromatograph (IEC) isotope dilution (ID) inductively coupled plasma mass spectrometry (ICP–MS) (IEC–ID–ICP–MS) was developed for measurement of dissolved silica in seawater, which was applied to production of certified reference materials (CRMs) of three concentration levels of nutrients (high, medium and low levels). IEC–ICP–MS has been employed to separate dissolved silica from seawater matrix. In the present study, in order to solve substantial problems due to spectral interference in ICP–MS and to improve the accuracy of IEC–ICP–MS beyond standard addition or conventional calibration methods, ID method was coupled with ICP-sector field mass spectrometry (operated under medium resolution,i.e., mm = 4000). In addition, effects of various operating parameters in ICP–MS on a silicon background level were also investigated to obtain lower background equivalent concentration (BEC). As a result, 3 ng g−1 of the BEC and 0.5 % of relative standard uncertainties were achieved in the analyses of dissolved silica in seawater samples at concentration levels from 4.0 mg kg -1 to 0.8 mg kg−1 as silicon. The developed method was successfully validated by analyses of an artificial seawater containing a known amount of silicate and the seawater certified reference material MOOS-2 produced by the National Research Council Canada.  相似文献   

13.
Use of seawater electrolytically enriched with hypochlorite and the in situ generation of hypochlorite on the high seas, stand a good chance for disinfection and decrease of bio and non-biodegradable organics in effluent before discharged into estuaries and deep oceans. Enriched seawater effectively decreased the biological oxygen demand measured over 5 days (BOD) and chemical oxygen demand (COD) levels of semi-treated wastewater. The oxidative degradation of Brilliant Blue, a triaryl industrial dye by hypochlorite and electrolytically enriched seawater are compared at pH 6.5. Both had similar magnitude second-order rate constants (21±1 M−1 s−1) and procedure is feasible. Increase in acid concentration enhanced the reaction rate. With 1:1 and 1:100 molar ratios of dye to hypochlorite, the COD=140 mg L−1 of 1.0×10−3 M dye reduced to 100 and 30 mg L−1 respectively.  相似文献   

14.
The chlorite ion is the principal by-product of the treatment of drinking water by chlorine dioxide. In function of the chlorite salt instability, standard solutions of this ion need standardization by iodometric titration, which is a reliable method although labor intensive and time consuming. An alternative method to standardization of aqueous chlorite solutions, based on its direct UV absorption measurement, was presented. Besides the maximum absorption (260 nm) generally used in other studies, the minimum (239 nm) and isosbestic (248 nm) wavelengths were proposed as supplementary points to chlorite quantification and their molar absorptivity coefficients were estimated (155.2 ± 0.6, 104.5 ± 1.0 and 69.0 ± 1.2 L cm−1 mol−1, respectively). The direct spectrophotometric determination of chlorite could be made selectively even in the presence of high concentration of major contaminants (chorine dioxide, chloride and chlorate), being a simple and rapid method, consuming very low volume of sample and generating low quantities of laboratory wastes.  相似文献   

15.
Isotope dilution analysis method coupled with flow injection and inductively coupled plasma mass spectrometry (ID-FI-ICP-MS), enabled trace lead concentration in seawater to be determined and the high salt concentration in the matrix, such as Na+, Ca2+ and Mg2+, to be removed on-line. The operational parameters of the FI system including pH for the chelating reaction, concentration of 8-hydroxyquinoline-5-sulfonic acid (8-HQS), sample loading time and injection speed, washing time and speed, eluting acid concentration and eluting speed, and instrumental parameters for ICP-MS were optimized and selected. Accurate results could be achieved because the isotope ratios required can be precisely measured in the range of the eluting peak by means of ID-FI-ICP-MS. The 3σ detection limit was 0.204 ng ml−1. The trace lead concentration of seawater in south Xiamen, China was 0.988 ± 0.039 ng ml−1. The recoveries of spiked Pb standard in seawater and standard reference water (GBW 08607) were 97.9 and 101.0%, respectively, with a relative standard deviation of 0.98%. This method can be used to determine trace lead concentration in high salt matrix samples, and is especially useful when the eluting peaks do not have a Gaussian-distribution.  相似文献   

16.
A new method is described for a precise and simultaneous determination of the rate of production and dissolution of biosilica in marine waters, using isotopic dilution technique. No HF or F2 is required for chemical preparations as the change in isotopic composition is measured on silica producing SiO2 ions. The seawater sample flask is spiked with 30Si(OH)4 (<10% of increase in situ concentration) and incubated in in situ conditions. At the end of incubation, changes of the 30Si:28Si ratios in particulate and liquid phases are measured by using a thermal ionisation mass spectrometer Finnigan THQ. The relative analytical precision of the isotopic ratio measurements is <0.5%. The limit of detection of the change in isotopic ratio during incubation is 0.02 atom%. The overall repeatability determined on eight subsamples (average production: 0.23 μM day−1; average dissolution: 0.07 μM day−1) is ±0.02 and ±0.01 μM day−1 for production and dissolution, respectively. Using mass and isotopic balances of the particulate and dissolved phases in the incubation flask, the best estimates for production and dissolution rates are calculated iteratively. This method was applied to 112 samples of marine waters (production, range: 0.00-2.38 μM day−1; dissolution, range: 0.00-1.18 μM day−1).  相似文献   

17.
A simple and rapid method was proposed for humic substances (HS) determination at microgram levels in natural waters. This assay method is based on the binding of a dye, Toluidine Blue (TB), to HS molecules to produce a dye-HS complex, which causes a decrease in absorbance at 630 nm. This method was calibrated with HS samples with up to a concentration of 40 mg L−1, which covered the range of dissolved HS concentrations present in natural waters. The detection limit was 0.8 mg L−1 of HS, and the relative standard deviation of 10 replicate measurements for a 20-mg L−1 standard sample was 3.5%. From the Langmuir adsorption isotherm theory, the binding equilibrium constant and total number of binding sites at neutral pH were calculated to be (8.17 ± 0.42) × 105 L mol−1 and N of 1.45 ± 0.04 mmol g−1 HS, respectively. The determination results with five water samples from lake, river and pond were consistent with those measured with the reference methods, demonstrating that this quantification method for HS determination was rapid, sensitive and feasible.  相似文献   

18.
A highly sensitive and relatively interference-free spectrophotometric method for determination of calcium is described. The method is based on the reaction between calcium ions and carboxyazo-p-CH3 in aqueous citrate medium of pH 7, to form a blue complex with maximum absorption at 716 nm. The calibration is linear up to 0.12 μg ml−1 calcium with a repeatability (R.S.D.) of 1.0% at a concentration of 0.04 μg ml−1 (n=5). The molar absorptivity of the complex and Sandell’s sensitivity are 3.5×105 l mol−1 cm−1 and 0.11 ng cm−2, its 10σ limit of quantification and the 3σ limit of detection were found to be 0.3 ng ml−1 and 0.09 ng ml−1 respectively. The influence of reaction variables and the effect of interfering ions are studied; no interference was observed in clinical samples. The proposed method has been applied directly to the determination of calcium in clinical samples without the need for pre-concentration, masking metal ions and digesting samples.  相似文献   

19.
The development of a slurry sampling method for the determination of calcium, copper, iron, magnesium and zinc in fish tissue samples by flame atomic absorption spectrometry is described. In comparison with microwave-assisted digestion, the proposed method is simple, requires short time and eliminates total sample dissolution before analysis. Suspension medium was optimized for each analyte to obtain quantitative recoveries from fish tissue samples without matrix interferences. Nevertheless, iron recoveries higher than 46% were not found. Treatment of samples slurried in nitric acid by microwave irradiation for 15-30 s at 75-285 W permitted to achieve efficient recoveries for calcium, iron, magnesium and zinc. Further improvement in the matrix effects for iron determination was accomplished by the use of an additional step of short microwave-assisted suspension treatment. However, standard addition method was required for calcium and copper determination, being necessary hydrochloric acid as suspension medium for the last one. Although copper could not be determined in the certified reference material using microwave-assisted digestion, the accuracy of the slurry sampling method was verified for all the investigated analytes. Detection limits were 22.8 ± 8.0, 0.884 ± 0.092, 5.07 ± 0.76, 35.5 ± 0.7 and 1.17 ± 0.04 μg g−1 for calcium, copper, iron, magnesium and zinc, respectively. The standard deviations obtained using slurry sampling method and microwave-assisted digestion were not significantly different, and the mean relative standard deviation of the over-all method (n = 3) of the slurry sampling method for different concentration levels was below 12%.  相似文献   

20.
A multi-pumping flow system (MPFS) for the spectrophotometric determination of dissolved orthophosphate and dissolved organic phosphorus in wastewater samples is proposed. The determination of orthophosphate is based on the vanadomolybdate method. In-line ultraviolet photo-oxidation is employed to mineralise organic phosphorus to orthophosphate prior to detection. A solenoid valve allows the deviation of the flow towards the UV-lamp to carry out the determination of organic phosphorus.Calibration was found to be linear up to 20 mg P L−1, with a detection limit (3sb/S) of 0.08 mg P L−1, an injection throughput of 75 injections h−1 and a repeatability (R.S.D.) of 0.6% for the direct determination of orthophosphate. On the other hand, calibration graphs were linear up to 40 mg P L−1, with a detection limit (3sb/S) of 0.5 mg P L−1, an injection throughput of 11 injections h−1 and a repeatability (R.S.D.) inferior to 2.3% for the procedures involving UV photo-oxidation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号