首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
A newly synthesized substrate, 3-hydroxybutyrylglycyl-glycyl-glycine (3HB-GGG), was applied to the assay of ACE-inhibiting activity to overcome the smaller selectivity and sensitivity of the conventional method. In this study, an ACE-inhibiting assay was improved by the use of a water-soluble tetrazolium salt, 4-[3-(4-iodophenyl)-2-(4-nitrophenyl)-2H-5-tetrazolio]-1,3-benzene disulfonate sodium salt (WST-1), for the detection of 3-hydroxybutyrate, derived from 3HB-GGG. The optimized conditions were as follows: 0.333 mM NAD(+), 0.333 mM WST-1, 0.1 mM EDTA, 0.633 U ml(-1) diaphorase, and 0.700 U ml(-1) 3-hydroxybutyrate dehydrogenase. The developed assay was efficiently applicable to evaluate the ACE-inhibiting activity of practical ACE inhibitors.  相似文献   

2.
Two miniature and compact optoelectronic devices fabricated by means of integration of light emitting diodes have been developed for turbidimetric and nephelometric measurements. These devices are operating according to paired-emitter-detector-diode (PEDD) principle. The detectors have been characterized using bovine serum albumin and Exton protein assay as a model analyte and a model analytical method, respectively. The developed detectors have been adapted for measurements under conditions of flow injection analysis (FIA). Under optimized conditions the turbidimetric flow system offers the range of linear response up to 400 mg L−1 with the detection limit at 20 mg L−1. The linear range and detection limit found for optimized nephelometric FIA system are 15–500 mg L−1 and 8 mg L−1, respectively. The PEDD-based FIA systems with the detector operating according to both modes of measurements have been successfully applied for urinalysis offering total protein determination at physiological and pathological levels with high throughput (over 60 injections per hour).  相似文献   

3.
A new kinetic method is proposed for the simultaneous determination of 3-hydroxybutyrate (3HB) and 3-hydroxyvalerate (3HV) based on the different rate of the 3-hydroxybutyrate dehydrogenase-catalysed reactions of these compounds with coenzyme NAD+. A flow injection system with two reactors of immobilised 3-hydroxybutyrate dehydrogenase and dual detection is used. The concentrations of NADH produced after two different reaction times are measured by fluorometry or spectrophotometry and multivariate linear calibration is applied for quantification. Concentrations of 3HB and 3HV between 1 × 10−6 and 1 × 10−4 M can be determined at an average sampling frequency of 20 h−1. In contrast to usual methods, the proposed here makes possible the discrimination of 3HB and 3HV without previous separation so that usual extraction with chlorinated solvents and/or chromatographic separation is not required. The method is of interest in a wide variety of fields concerning PHAs, as it can provide information on the degradation rate and mechanism, composition and structure of these polymers. Its applicability has been proved through the determination of 3HB and 3HV in the digests of some chemically degraded commercial PHAs.  相似文献   

4.
Sohn OJ  Han KA  Rhee JI 《Talanta》2005,65(1):185-191
In this study, a flow injection analysis (FIA) system using a cartridge of immobilized isocitrate lyase (ICL) and isocitrate dehydrogenase (ICDH) was developed to monitor the concentrations of succinic acid in biotechnological processes. The ICL and ICDH immobilized on VA-Epoxy Biosynth E3-carrier had a good operational lifetime (up to 24 h) and storage stability (up to 30 days). The FIA system with the immobilized ICL/ICDH cartridge was characterized with respect to the factors affecting the activity of the immobilized enzymes, such as pH of carrier solution, temperature, sample matrix, etc. Optimal pH value of the immobilized enzymes was slightly shifted in the alkaline range, i.e. 9.0. Some components such as 10 g l−1 lactose, 3 g l−1 malate and 3 g l−1 oxaloacetate in sample solution had significant activating effects (more than 10%) on the response of the FIA system. But the activity of the immobilized ICL and ICDH was not largely influenced by some components like imidazole (1 mM), sodium azide (10 mM) and semicarbazide (2 g l−1) added to carrier buffer solution. The FIA system with an enzyme cartridge was applied to on-line monitor the concentrations of succinic acid in a continuously stirred reactor and a fermentation process of immobilized Escherichia coli, and showed good sensitivity and reliability of the FIA system developed in this work.  相似文献   

5.
The enzyme xanthine oxidase (XOD) has been recognized as a key enzyme causing oxidative injury to tissues by ischemia-reperfusion. For this reason, XOD inhibitor, which effectively suppresses this enzyme, plays an important role in the inhibition of many diseases related to reactive oxygen species (ROS). In order to screen XOD inhibitors rapidly and conveniently, a novel assay using flow injection analysis (FIA) was proposed in the present investigation. To optimize the practical FIA system, we studied the effect of the reagent concentrations and the flow condition on the enzymatic reaction, and then selected the optimum condition as follows: 200-mU/ml XOD concentration, 0.5-mM xanthine concentration, 0.5-ml/min flow rate, and 2-m mixing coil length. Under this condition, a typical XOD inhibitor quercetin was determined in the concentration range 0.1 - 1.5 mM at a sampling frequency of 10 samples/h. Using the optimized FIA method, we determined the XOD inhibitory activity of some food samples: onions, apples and teas, which are the high sources of flavonoids known as the potential XOD inhibitors. Among these samples, tea leaves showed the highest activity, the second was onions and the lowest was apples. Based on the result of the assay, not only quercetin, but also other components in investigated samples, contributed to the XOD inhibitory activity.  相似文献   

6.
Tsukatani T  Matsumoto K 《Talanta》2006,69(3):637-642
A flow-injection system for the quantification of pyruvate based on the coupled reactions of pyruvate decarboxylase (PDC) and aldehyde dehydrogenase (AlDH) was conceived and optimized. A co-immobilized PDC and AlDH reactor was introduced into the flow line. Sample and reagent (NAD+) were injected into the flow line by an open sandwich method and the increase of NADH produced by the immobilized-enzyme reactor was monitored fluorometrically at 455 nm (excitation at 340 nm). Linear relationships between the responses and concentrations of pyruvate were observed in the ranges of 2.0 × 10−5 to 1.5 × 10−3 M at the flow rate of 1.0 ml min−1 and 5.0 × 10−6 to 1.0 × 10−3 M at the flow rate of 0.5 ml min−1. The relative standard deviation for 10 successive injections was 0.95% at the 1.0 mM level. This FIA system for pyruvate was applied to the measurement of acetate, citrate and l-lactate.  相似文献   

7.
A sensitive FIA method was developed for the selective determination of formaldehyde in alcoholic beverages. This method is based on the reaction of Fluoral-P (4-amine-3-pentene-2-one) with formaldehyde, leading to the formation of 3,5-diacetyl-1,4-dihydrolutidine (DDL), which fluoresces at λex = 410 nm and λem = 510 nm. The analytical parameters were optimized by the response surface method using the Box-Behnken design. The proposed flow injection system allowed for the determination of up to 3.33 × 10−5 mol L−1 of formaldehyde with R.S.D. < 2.5% and a detection limit of 3.1 ng mL−1. The method was successfully applied to determine formaldehyde in alcoholic beverages, without requiring any sample pretreatment, and the results agreed with the reference at a 95% confidence level by paired t-test. In the optimized condition, the FIA system proved able to analyze up to 60 samples/h.  相似文献   

8.
A long-life capillary enzyme bioreactor was developed that determines glucose concentrations with high sensitivity and better stability than previous systems. The bioreactor was constructed by immobilizing glucose oxidase (GOx) onto the inner surface of a 0.53 mm i.d. fused-silica capillary that was part of a continuous-flow system. In the presence of oxygen, GOx converts glucose to gluconic acid and hydrogen peroxide (H2O2). Hydrogen peroxide detection was accomplished using an amperometric electrochemical detector. The integration of this capillary reactor into a flow-injection (FIA) system offered a larger surface-to-volume ratio, reduced band-broadening effects, and reduced reagent consumption compared to packed column in FIA or other settings. To obtain operational (at ambient temp) and storage (at 4 °C) stability for 20 weeks, the glucose biosensing system was prepared using an optimal GOx concentration (200 mg/mL). This exhibited an FIA peak response of 7 min and a detection limit of 10 μM (S/N = 3) with excellent reproducibility (coefficient of variation, CV < 0.75%). It also had a linear working range from 101 to 104 μM. The enzyme activity in this proposed capillary enzyme reactor was well maintained for 20 weeks. Furthermore, 20 serum samples were analyzed using this system, and these correlated favorably (correlation coefficient, r2 = 0.935) with results for the same samples obtained using a routine clinical method. The resulting biosensing system exhibited characteristics that make it suitable for in vivo application.  相似文献   

9.
Xu D  Liu S  Liu Z  Hu X 《Analytica chimica acta》2007,588(1):10-15
A flow injection analysis (FIA) method coupled to resonance Rayleigh scattering (RRS) detection for the determination of verapamil hydrochloride (VP) was proposed. In pH 1.0 acidic medium, 12-tungstophosphoric acid (TP) reacted with VP to form an ion-association complex, which resulted in a significant enhancement of RRS intensity. The maximum scattering peak was located at 293 nm. RRS intensity was proportional to the concentration of VP in the range of 0.017-13.0 μg mL−1, and the detection limit (3σ) was 5.1 ng mL−1. The proposed method exhibited satisfactory reproducibility with a relative standard derivation (R.S.D.) of 2.1% for 11 successive determinations of 5.0 μg mL−1 VP. Therefore, a novel method for the determination of VP by FIA-RRS was developed. The optimum reaction conditions and the parameters of the FIA operation such as flow rate, injection volume, reactor length, and so on had been optimized in this paper. The present method had been applied to the determination of VP in serum samples and pharmaceuticals with satisfactory results. The maximal sample throughput in the optimized system was 80 h−1.  相似文献   

10.
A convenient and continuous method for the assay of α-glucosidase (AGH) inhibitory activity was developed using a continuous-flow/stopped-flow system combined with biosensors. The amount of glucose liberated from maltose by the action of AGH was quantified by an immobilized glucose oxidase (GOD) reactor with a Clark oxygen sensor in the downstream. The immobilized AGH reactor was set in the flow-line. When an inhibitor containing 10 mM maltose substrate was injected and as it reaches the center of the immobilized AGH reactor, the working solution (synthetic intestinal fluid) was stopped for a certain period. After the reaction of inhibitor and/or substrate with AGH, the working solution was propelled again, and the glucose liberated was passed through the immobilized GOD reactor. The inhibition ratios (%) were calculated as the percent inhibition, which were the glucose concentrations in the presence of maltose and inhibitor divided by those in the presence of maltose alone. The multi-channel stopped-flow (MCSF) system was also developed, in which a seven-port, six-positioned rotary valve was inserted and six immobilized AGH reactors were set in a parallel configuration. The IC50 values of acarbose and 1-deoxynojirimycin, a medicinal inhibitor for diabetes, were 0.46±0.062 and 0.23±0.031 μM, respectively, and coincided well with those by our pseudo-in vivo method [Biol. Pharm. Bull. 232 (2000) 1084]. The time to assay the inhibitory activity of one unknown sample was estimated to be 11 min by the 6-channel modified-MCFS system. The proposed MCFS system offers a useful method to evaluate the inhibitory activity for AGH.  相似文献   

11.
Zhang LL  Cattrall RW  Kolev SD 《Talanta》2011,84(5):1278-1283
This paper reports the first use of a polymer inclusion membrane (PIM) for on-line separation in flow injection analysis (FIA) involving simultaneous extraction and back-extraction. The FIA system containing the PIM separation module was used for the determination of Zn(II) in aqueous samples in the presence of Mg(II), Ca(II), Cd(II), Co(II), Ni(II), Cu(II), and Fe(III). The Fe(III) and Cu(II) interferences were eliminated by off-line precipitation with phosphate and on-line complexation with chloride, respectively. The concentration of Zn(II) was determined spectrophotometrically using 4-(2-pyridylazo) resorcinol (PAR). The optimal composition of the PIM consisted of 40% (m/m) di(2-ethlyhexyl) phosphoric acid (D2EHPA) as carrier, 10% (m/m) dioctyl phthalate (DOP) as plasticizer and 50% (m/m) poly(vinyl chloride) (PVC) as the base polymer. The optimized FIA system was characterized by a linear calibration curve in the range from 1.0 to 30.0 mg L−1 Zn(II), a detection limit of 0.05 mg L−1 and a relative standard deviation of 3.4% with a sampling rate of 4 h−1. Reproducible results were obtained for 20 replicate injections over a 5 h period which demonstrated a good membrane stability. The FIA system was applied to the determination of Zn(II) in pharmaceuticals and samples from the galvanizing industry and very good agreement with atomic absorption spectrometry was obtained.  相似文献   

12.
We herein report on the electrocatalytic activity towards the oxidation of NADH of a PVC/TTF‐TCNQ composite electrode modified with gold nanoparticles. This electrocatalytic property allows proposing this system as a new alternative for amperometric determination of NADH, without need to add another mediator. The sensor shows a linear response to NADH over a concentration range from 5.0×10?6 M up to 5.0×10?4 M, with a sensitivity of 11.22±0.5 mA M?1 and a detection limit (S/N=3) of 4.0×10?6 M for measurements in batch and similar data in FIA.  相似文献   

13.
A novel flow injection analysis (FIA) system based on liquid-liquid microextraction and fluorimetric determination was developed for the determination of traces of the Zn2+ ion using 5-(8-hydroxy-2-quinolinylmethyl)-2,8-dithia-5-aza-2,6-pyridinophane (L) as a sensitive and selective fluorimetric sensor, with λex = 373 nm and λem = 530 nm, and hexanol as the extracting organic solvent. In the designed FIA system, the phase separation takes place via gravitation forces in the absence of any segmenter. The influence of pH and ionic strength of the solution, amount of ligand, nature of counter ion, volume of organic solvent, extraction time and coil length was investigated. Under optimized experimental conditions, the calibration curve found to be liner over a concentration range of 0.025-4.53 μg mL−1 (R2 = 0.9951) with a limit of detection of 2.3 ng mL−1. The enrichment factor was 45 and relative standard deviation for 7 replicate determinations was 2.43%. The method is very fast and uses low levels of organic solvents. The proposed method was applied successfully to the determination of zinc(II) in human hair, human serum and two inorganic sludge samples.  相似文献   

14.
Poly[(R)-3-hydroxybutyrate] (P(3HB)) fibers with high tensile strength were prepared by stretching the fibers after isothermal crystallization near the glass transition temperature. Two samples with different molecular weights (Mw = 0.7 × 106 and 4.3 × 106) were used to investigate the effect on tensile strength. Increasing the time for isothermal crystallization of P(3HB) fibers resulted in a decrease in the maximum draw ratio. But, the tensile strength of P(3HB) fibers increased remarkably when the isothermal crystallization time was prolonged to more than 24 h. The tensile strength of low-molecular-weight drawn fibers was higher than that of high-molecular-weight fibers. Therefore, it can be concluded that this procedure does not increase the tensile strength of the high-molecular-weight drawn fibers. This is because, in this drawing method, small crystal nuclei grow initially during the isothermal crystallization process. Then, the molecular chains between the small crystal nuclei that acted as the entanglement points are oriented by stretching. In the case of the high-molecular-weight fibers, because the molecular length between the entanglement points of the small crystal nuclei is too long, the molecular chains are not sufficiently oriented by the stretching process. However, in the case of the low-molecular-weight fibers, the molecular length is suitable for generating the extended chains. Based on the result of X-ray analysis of P(3HB) fibers stretched after isothermal crystallization, fibers have the oriented α-form crystal with 21 helix conformation and β-form with planar zigzag conformation. The enzymatic degradation of the stretched P(3HB) fibers was performed by using an extracellular PHB depolymerase purified from Ralstonia pickettii T1. The enzymatic erosion rate of β-form was faster than that of α-form in the P(3HB) fibers stretched after isothermal crystallization.  相似文献   

15.
A novel strategy was successfully developed for screening trypsin inhibitors in traditional Chinese medicines based on monolithic capillary immobilized enzyme reactors combined with liquid chromatography‐tandem mass spectrometry. Organic polymer based monolithic enzyme reactors were firstly prepared by covalently bonding trypsin to a poly(glycidyl methacrylate‐co‐poly (ethylene glycol) diacrylate) monolith by the ring‐opening reaction of epoxy groups. The activity and kinetic parameters of the obtained monolithic trypsin reactors were systematically evaluated using micro‐liquid chromatography. Fourier transform infrared spectroscopy and scanning electron microscopy were also used to characterize the monolithic trypsin reactors. The resulting functional and denatured monolithic trypsin reactors were applied as affinity solid‐phase extraction columns, and offline coupled with a liquid chromatography‐tandem mass spectrometry system to construct a binding affinity screening platform. Subsequently, the proposed platform was applied for screening trypsin binders in a Scutellaria baicalensis Georgi extract. Three compounds, namely scutellarin, baicalin, and wogonoside were identified, and their inhibitory activities were further confirmed via an in vitro enzymatic inhibition assay. Additionally, molecular docking was also performed to study the interactions between trypsin and these three compounds.  相似文献   

16.
Boni AC  Wong A  Dutra RA  Sotomayor Mdel P 《Talanta》2011,85(4):2067-2073
A biomimetic sensor for the determination of dipyrone was prepared by modifying carbon paste with cobalt phthalocyanine (CoPc), and used as an amperometric detector in a flow injection analysis (FIA) system. The results of cyclic voltammetry experiments suggested that CoPc behaved as a biomimetic catalyst in the electrocatalytic oxidation of dipyrone, which involved the transfer of one electron. The optimized FIA procedure employed a flow rate of 1.5 mL min−1, a 75 μL sample loop, a 0.1 mol L−1 phosphate buffer carrier solution at pH 7.0 and amperometric detection at a potential of 0.3 V vs. Ag/AgCl. Under these conditions, the proposed method showed a linear response for dipyrone concentrations in the range 5.0 × 10−6-6.3 × 10−3 mol L−1. Selectivity and interference studies were carried out in order to validate the system for use with pharmaceutical and environmental samples. In addition to being environmentally friendly, the proposed method is a sensitive and selective analytical tool for the determination of dipyrone.  相似文献   

17.
A novel all-solid-state miniaturized nitrate sensor is developed, characterized and used for flow injection analysis (FIA) of nitrates in various samples. The sensor incorporates silver bis(bathophenanthroline) nitrate [Ag(bath)2NO3] as an electroactive material in a plasticized PVC membrane. The sensing membrane (3 mm × 5 mm) is immobilized on a wafer polyimide microchip (size 13.5 mm × 3.5 mm) to offer a planar miniaturized design easily used in a single channel wall-jet flow injection system. Under hydrodynamic mode of operation (FIA) the sensor displays fast response, high sensitivity, long term stability and good selectivity for NO3 in the presence of many common associated anions. The calibration slope is 55.1 ± 0.1 mV decade−1 over the concentration range 1.0 × 10−1 to 1.0 × 10−6 mol L−1, the lower detection limit is 0.05 μg mL−1, the working pH is 2-9,and the output is 70-90 samples h−1. Validation of the assay method reveals good performance characteristics and suggests application for routine determination of NO3 in industrial wastewaters, fertilizers and pharmaceuticals. The results agree fairly well with data obtained by the standard spectrophotometric methods.  相似文献   

18.
A flow injection analysis (FIA) procedure for the determination of anisidine value (AV) in palm olein using a triiodide detector is described. Undiluted oil sample and chloramine-T reagent were added to a reaction chamber, and reaction was accelerated by applying a short vortex action (typically for 30 s). After allowing the emulsified oil phase to be separated from the aqueous phase (bottom layer), an aliquot of the aqueous phase (containing unreacted chloramine-T) was aspirated into a carrier stream that contained I where the chloramine-T oxidized the I to form I3 which was finally detected by a flow-through triiodide potentiometric detector. Variables that affect the FIA signals such as size of the reaction chamber, oil and reagent flow rates, chloramine-T concentration, vortex time, time for phase separation, carrier stream pH and injected volume were studied. The optimized FIA procedure is linear over 1.0-23.0 AV. The method exhibits good repeatabililty (R.S.D. of ±3.16% (n = 4) for the determination of 5.0 AV) and a sampling rate of 40 samples per hour was achieved. Good correlation (r2 = 0.996 (n = 4)) between the proposed method and the manual American Oil Chemists’ Society procedure was found when applied to the determination of twenty different types of palm olein samples.  相似文献   

19.
A FIA system based on a micellar system for a substrate (p-nitrophenylbutyrate) with low stability in aqueous phase was built to monitor cutinase activity in bioprocesses. All samples were previously diluted with 50 mM phosphate buffer pH 7.0 containing 11.6 mM sodium cholate. The cutinase activity in this diluted solution enhances about 40% in relation to phosphate buffer. Furthermore, the enzyme adsorption and consequent blocking/fouling of injector and tubes of the FIA system was eliminated due to excellent properties of sodium cholate as surface active agent.The cutinase activity is based in following the hydrolysis of p-nitrophenylbutyrate to p-nitrophenol in the reaction stream through the formation of an absorbance peak at 400 nm proportional to enzyme activity. The compositions of reaction stream as well as its stability were studied in order to minimize non-enzymatic hydrolysis of p-nitrophenylbutyrate and maximize cutinase activity assay reproducibility. An excellent correlation was obtained between the FIA system and off-line method for determination of cutinase activity in the culture media, and during separation of Saccharomyces cerevisiae cells and cutinase concentration by micro and ultrafiltration, respectively.  相似文献   

20.
A new, highly sensitive, fast responding and stable potentiometric biosensor for creatinine determination is developed. The biosensor is based on an ammonium ion-selective electrode. Creatinine deiminase (EC 3.5.4.21) is chemically immobilized on the surface of the polymeric ion-sensitive membrane in the form of monomolecular layer using a simple, one-step carbodiimide covalent attachment method. The resulting enzyme electrodes are useful for measurement under flow injection analysis (FIA) conditions. The biosensors exhibit excellent operational and storage stability. The enzyme electrodes retain over 70% of initial sensitivity after ten weeks of work under FIA conditions. The storage stability at 4 °C is longer than half a year without loss of sensitivity. Under optimized conditions near 30 samples per hour can be analyzed and the determination range (0.02-20.0 mmol l−1) fully covers creatinine concentrations important from clinical and biomedical point of view. The simple biosensor/FIA system has been successfully used for determination of creatinine in urine, serum and posthemodialysate samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号