 共查询到20条相似文献,搜索用时 437 毫秒
1.
A microchip structure for field amplification stacking (FAS) was developed, which allowed the formation of comparatively long, volumetrically defined sample plugs with a minimal electrophoretic bias. Up to 20-fold signal gains were achieved by injection and separation of 400 microm long plugs in a 7.5 cm long channel. We studied fluidic effects arising when solutions with mismatched ionic strengths are electrokinetically handled on microchips. In particular, the generation of pressure-driven Poiseuille flow effects in the capillary system due to different electroosmotic flow velocities in adjacent solution zones could clearly be observed by video imaging. The formation of a sample plug, stacking of the analyte and subsequent release into the separation column showed that careful control of electric fields in the side channels of the injection element is essential. To further improve the signal gain, a new chip layout was developed for full-column stacking with subsequent sample matrix removal by polarity switching. The design features a coupled-column structure with separate stacking and capillary electrophoresis (CE) channels, showing signal enhancements of up to 65-fold for a 69 mm long stacking channel.  相似文献   

2.
The ability to accurately inject small volumes of sample into microfluidic channels is of great importance in electrophoretic separations. While electrokinetic injection of nanoliter scale volumes is commonly utilized in microchip capillary electrophoresis (MCE), mobility and matrix bias makes quantitation difficult. Herein, we describe a new injection method based on the simple patterning of the crossing of channels that does not require sophisticated instrumentation. The sample volume injected into the separation channel is dependent on the ratio of the widths of the crossing channels. This injection method is capable of introducing, into a separation channel, multiple plugs of sample on a large scale. This injection technique is tested for zone electrophoresis in native and surface modified poly(dimethylsiloxane) (PDMS) chips.  相似文献   

3.
Zhang L  Yin X  Fang Z 《Lab on a chip》2006,6(2):258-264
A simple method for injecting well-defined non-biased sample plugs into the separation channel of a microfluidic chip-based capillary electrophoresis system was developed by a combination of flows generated by negative pressure, electrokinetic and hydrostatic forces. This was achieved by using only a single syringe pump and a single voltage supply at constant voltage. In the loading step, a partial vacuum in the headspace of a sealed sample waste reservoir was produced using a syringe pump equipped with a 3-way valve. Almost instantaneously, sample was drawn from the sample reservoir across the injection intersection to the sample waste reservoir by negative pressure. Simultaneously, buffer flow from the remaining two buffer reservoirs pinched the sample flow to form a well-defined sample plug at the channel intersection. In the subsequent separation stage, the vacuum in headspace of the sample waste reservoir was released to terminate all flows generated by negative pressure, and the sample plug at the channel intersection was electrokinetically injected into the separation channel under the potential applied along the separation channel. The liquid levels of the four reservoirs were optimized to prevent sample leakage during the separation stage. The approach considerably simplified the operations and equipment for pinched injection in chip-based CE, and improved the throughput. Migration time precisions of 3.3 and 1.5% RSD for rhodamine123 (Rh123) and fluorescein sodium (Flu) in the separation of a mixture of Flu and Rh123 were obtained for 56 consecutive determinations with peak height precisions of 6.2% and 4.4% RSD for Rh123 and Flu, respectively.  相似文献   

4.
Qin WH  Cao CX  Li S  Zhang W  Liu W 《Electrophoresis》2005,26(16):3113-3124
The paper advanced the theoretical procedures for quantitative design on selective stacking of zwitterions in full capillary sample matrix by a cathodic-direction moving reaction boundary (MRB) in capillary electrophoresis (CE) under control of electroosmotic flow (EOF). With the procedures, we conducted the theoretical computations on the selective stacking of two test analytes of L-histidine (His) and L-tryptophan (Trp) by the MRB created with 30 mM pH 3.0 formic acid-NaOH buffer and 2-80 mM sodium formate. The results revealed the following three predictions. At first, the MRB cannot stack His and Trp plugs if less than 12.5 mM sodium formate is used to form the MRB and prepare the sample matrix. Second, the MRB can stack His and/or Trp sample plugs completely if higher than 50 mM sodium formate is chosen to form the MRB. Third, the MRB can only focus His plug completely, but stack Trp plug partially if 20-50 mM sodium formate is used; this implied the complete MRB-induced selective stacking to His rather than Trp. All the three predictions were quantitatively proved by the experiments. With great dilution of sample matrix and control of EOF, controllable, simultaneous and MRB-induced selective stacking and separation of zwitterions were achieved. The theoretical results hold evident significances to the quantitative design of selective stacking conditions and the increase of detection sensitivity of zwitterions in CE. In addition, the control of EOF by cetyltrimethylammonium bromide (CTAB) can evidently improve the stacking efficiency to both His and Trp.  相似文献   

5.
Liu L  Chen X  Hu Z 《Electrophoresis》2005,26(23):4456-4464
A novel, rapid, and continuous online concentration approach based on field-amplified sample injection for the analysis of fangchinoline and tetrandrine was developed in this paper by combination of flow injection-MEKC. The BGE used was a solution composed of 75 mM H3PO4-triethylamine-2.5% v/v polyoxyethylene sorbitan monolaurate-20% v/v methanol buffer (pH* 5.0). The analytes prepared in 50% v/v aqueous ethanol were used as the test analytes. Sample was injected electrokinetically between plugs of water. When the cations reached the boundary between the water plug and BGE, they slowed down and became concentrated. Thereafter, MEKC was initiated for the separation. This results in 6.8-8.9-fold improvement in concentration sensitivity relative to conventional CE methods. The separation could be achieved within 10 min and sample throughput rate can reach up to 50/h. The repeatability (defined as RSD) was 4.8, 4.4% with peak height evaluation and 3.6, 0.94% with peak area evaluation for TET and FAN, respectively.  相似文献   

6.
Qi LY  Yin XF  Zhang L  Wang M 《Lab on a chip》2008,8(7):1137-1144
A rapid and variable-volume sample loading scheme for chip-based sieving electrophoresis was developed by negative pressure combined with electrokinetic force. This was achieved by using a low-cost microvacuum pump and a single potential supply at a constant voltage. Both 12% linear polyacrylamide (LPA) with a high viscosity of 15000 cP and 2% hydroxyethylcellulose (HEC) with a low viscosity of 102 cP were chosen as the sieving materials to study the behavior and the versatility of the proposed method. To reduce the hydrodynamic resistance in the sampling channel, sieving material was only filled in the separation channel between the buffer waste reservoir (BW) to the edge of the crossed intersection. By applying a subambient pressure to the headspace of sample waste reservoir (SW), sample and buffer solution were drawn immediately from sample reservoir (S) and buffer reservoir (B) across the intersection to SW. At the same time, the charged sample in the sample flow was driven across the interface between the sample flow and the sieving matrix into the sieving material filled separation channel by the applied electric field. The injected sample plug length is in proportion with the loading time. Once the vacuum in SW reservoir was released to activate electrophoretic separation, flows from S and B to SW were immediately terminated by the back flow induced by the difference of the liquid levels in the reservoirs to prevent sample leakage during the separation stage. The sample consumption was about 1.7 x 10(2) nL at a loading time of 1 s for each cycle. Only 0.024 s was required to transport bias-free analyte to the injection point. It is easy to freely choose the sample plug volume in this method by simply changing the loading time and to inject high quality sample plug with non-distorted shape into the separation channel. The system has been proved to possess an exciting potential for improving throughput, repeatability, sensitivity and separation performance of chip-based sieving electrophoresis.  相似文献   

7.
Zhang L  Yin X 《Electrophoresis》2007,28(8):1281-1288
A simple and powerful microfluidic array chip-based electrophoresis system, which is composed of a 3-D microfluidic array chip, a microvacuum pump-based negative pressure sampling device, a high-voltage supply and an LIF detector, was developed. The 3-D microfluidic array chip was fabricated with three glass plates, in which a common sample waste bus (SW(bus)) was etched in the bottom layer plate to avoid intersecting with the separation channel array. The negative pressure sampling device consists of a microvacuum air pump, a buffer vessel, a 3-way electromagnet valve, and a vacuum gauge. In the sample loading step, all the six samples and buffer solutions were drawn from their reservoirs across the injection intersections through the SW(bus) toward the common sample waste reservoir (SW(T)) by negative pressure. Only 0.5 s was required to obtain six pinched sample plugs at the channel crossings. By switching the three-way electromagnetic valve to release the vacuum in the reservoir SW(T), six sample plugs were simultaneously injected into the separation channels by EOF and electrophoretic separation was activated. Parallel separations of different analytes are presented on the 3-D array chip by using the newly developed sampling device.  相似文献   

8.
A novel method for performing in-column field-amplified sample stacking (FASS) in chip-based electrophoretic systems is presented. The methodology involves the use of a narrow sample channel (NSC) injector. NSC injectors allow sample plugs to be introduced directly into the separation channel, and subsequent stacking and separation can proceed without any need for leakage control. More importantly, stacking and separation occur in a single step negating the requirement for complex channel geometries and voltage switching to control sample plugs during the stacking procedure. The chip is composed of six paralleled systems. Using the NSC injector design, the number of reservoirs in the multiplexed chip is reduced to N + 2, where N is the number of paralleled systems. This design feature radically reduces the complexity in chip structures and associated chip operation. The approach is applied to the analysis of fluorescently labelled biogenic amines affording detection at concentrations down to 20 pM.  相似文献   

9.
Sample pre-concentration by isotachophoresis in microfluidic devices   总被引:1,自引:0,他引:1  
We have designed microfluidic devices with the aim of coupling isotachophoresis (ITP) with zone electrophoresis (ZE) as a method to increase the concentration limit of detection in microfluidic devices. We used plastic multi-channel chips, designed with long sample injection channel segments, to increase the sample loading. The chip was designed to allow stacking of the sample into a narrow band by discontinuous ITP buffers and subsequent separation in the ZE mode. In the ITP-ZE mode, with a 2-cm long sample injection plug, sensitivity was increased by 400-fold over chip ZE and we found that the separation performance after the ITP stacking was comparable to that of regular chip ZE. We report sub-picomolar limits of detection of fluorescently labeled ACLARA eTag reporter molecules electrokinetically injected from cell lysate sample matrixes containing moderate salt concentrations. We evaluated sample injections from buffers with varied ionic strengths and found that efficient stacking and separations were obtained in both low and high conductivity buffers, including physiological buffer with at least 140 mM salt. We applied ITP-ZE to the analysis of a cell surface protease (ADAM 17) which used live intact cells in physiological buffers with detection limits below 10 cells/assay.  相似文献   

10.
Yang S  Liu J  DeVoe DL 《Lab on a chip》2008,8(7):1145-1152
Multidimensional microfluidic separation systems combining a first dimension microchannel with an array of parallel second dimension microchannels can suffer from non-uniform sample transfer between the dimensions, sample leakage, and injection plug tailing within the second dimension array. These factors can significantly reduce overall two-dimensional separation performance. In this paper, numerical and analytical models reveal an optimized chip design which combines multidimensional backbiasing and an angled channel geometry to ensure leakage-free and uniform interdimensional sample transfer, while also minimizing injected sample plug lengths. The optimized design is validated experimentally using a multidimensional chip containing five second dimension channels.  相似文献   

11.
A new on-chip injector for microchip-based flow analyses has been designed and characterized. The microchip design utilizes separate laminar flow streams of buffer and sample that are brought into parallel contact for a distance of 300 microm. The buffer flow stream is first routed through a conventional 6-port injection valve fitted with a 5 microm i.d. sample loop. When the 6-port valve is actuated from load to inject for a given time, the on-chip buffer flow stream is constricted and the sample flow stream is pressurized into the buffer flow channel. Once the valve returns to the load state the separate laminar flow streams resume. Fluorescence detection was used to characterize the injector and it was found that 50 injections of a 100 microM fluorescein sample led to an average peak height of 174.32 +/- 2.05 AFU (RSD 1.18%) and average peak skew of 1.37 +/- 0.06. The injector was also interfaced with amperometric detection. Injections of catechol solutions ranging in concentration from 500 nM to 100 microM resulted in a linear response (sensitivity = 2.49 pA microM(-1), r(2) = 0.998) and a limit of detection of 155 nM (S/N = 3). Compared to an off-chip injection scheme, plug dilution, band broadening, and peak asymmetry are much reduced. Finally, the injection and subsequent lysis of an erythrocyte sample was demonstrated, with an injected plug of erythrocytes being lysed 5.72 +/- 0.15 s after injection into a flow stream containing sodium dodecyl sulfate (n = 10). The new injection scheme does not require complex valving mechanisms or high pressures and enables reproducible injections from a continuous sample flow stream in a manner where changes in analyte concentration can be monitored with high temporal resolution.  相似文献   

12.
Sample stacking can occur in isoconductive buffer systems as a result of ion transport mismatches that cause changes in buffer conductivity during electrophoresis. Fluorescence imaging was used to examine this effect in the sweeping of hydrophobic dyes with sodium dodecyl sulfate (SDS) on microchips. Imaging revealed the occurrence of a stacking effect in a sodium borate buffer system in which the sample buffer and SDS-containing run buffer had the same initial conductivity. Injected sample plugs were first swept by SDS micelles and the swept band was then stacked at the trailing end of the sample zone. This effect is due to changes in conductivity at both the front and back interfaces of the injected sample plug and can be modeled by moving boundary equations. Maximum signal enhancements of 86-, 160- and 560-fold were obtained for Rhodamine 560, Rhodamine B and Rhodamine 6G, respectively, by the combination of sweeping and stacking within a 1 cm section of microchannel. Based on sample sweeping/stacking and manipulation of the electric field polarity, a method of trapping and concentrating analyte from multiple injections was also demonstrated.  相似文献   

13.
Lacharme F  Gijs MA 《Electrophoresis》2006,27(14):2924-2932
We propose two variants of a new injection technique for use in electrophoresis microchips, called "front gate pressure injection" and "back gate pressure injection", that both enable a controlled and reproducible sample introduction with reduced bias compared to electrokinetic gated injection. A continuous flow of a test solution of fluorescein/rhodamine B in 20 mM Tris/boric acid buffer (pH 8.6) sample test solution is electrokinetically driven near to the entrance of the separation channel, using a single voltage (3 kV) that is constant in time. A sample plug is injected in the separation channel by a pressure pulse of the order of 0.1 s. The latter is generated using the mechanical deflection of a PDMS membrane that is loosely placed on a dedicated chip reservoir. The analysis of the peak area ratio of the separated compounds demonstrates a nearly constant sample composition when using pressure-based injection. A small remaining injection bias for the shortest membrane deflection times can be attributed to a dilution effect of the charged compound due to the presence of an electrical field transverse to the sample flow boundary in the channel junction.  相似文献   

14.
An ESI emitter made of poly(dimethylsiloxane) interfaces on-chip sample preparation with MS detection. The unique multilayer design allows both the analyte and the spray solutions to reside on the device simultaneously in discrete microfluidic environments that are spatially separated by a polycarbonate track-etched, nanocapillary array membrane (NCAM). In direct spray mode, voltage is applied to the microchannel containing a spray solution delivered via a syringe pump. For injection, the spray potential is lowered and a voltage is applied that forward biases the membrane and permits the analyte to enter the spray channel. Once the injection is complete, the bias potential is switched off, and the spray voltage is increased to generate the ESI of the injected analyte plug. Consecutive injections of a 10 microM bovine insulin solution are reproducible and produce sample plugs with limited band broadening and high quality mass spectra. Peptide signals are observed following transport through the NCAM, even when the peptide is dissolved in solutions containing up to 20% seawater. The multilayer emitter shows great potential for performing multidimensional chemical manipulations on-chip, followed by direct ESI with negligible dead volume for online MS analysis.  相似文献   

15.
Luo Y  Zhang Q  Qin J  Lin B 《Electrophoresis》2007,28(24):4769-4771
Hydrostatic pressure sample injection method is able to minimize the number of electrodes needed for a microchip electrophoresis process; however, it neither can be applied for electrophoretic DNA sizing, nor can be implemented on the widely used single-cross microchip. This paper presents an injector design that makes the hydrostatic pressure sample injection method suitable for DNA sizing. By introducing an assistant channel into the normal double-cross injector, a rugged DNA sample plug suitable for sizing can be successfully formed within the cross area during the sample loading. This paper also demonstrates that the hydrostatic pressure sample injection can be performed in the single-cross microchip by controlling the radial position of the detection point in the separation channel. Rhodamine 123 and its derivative as model sample were successfully separated.  相似文献   

16.
Oguri S  Hibino M  Mizunuma M 《Electrophoresis》2004,25(12):1810-1816
We report on the effect on performance of varying the length of the capillary during throughout in-capillary derivatization (TICD) capillary electrophoresis (CE). Performance was evaluated by on-line coupling with a sample and CE runbuffer loading device that was newly introduced for this study. The device was assembled with a low cost using two 5 mm inner diameter (ID) disposable polyethylene syringes. First, a sequence was manually formed consisting of a 200 microL run buffer solution plug, a 100 microL sample plug and another 200 microL run buffer solution plug. Each plug was separated from its neighbor by a 100 microL air plug. When each plug reached the injection point where both a platinum-wire anode and the end of the separation capillary tube were located, 340 V/cm separation voltage (electrophoresis voltage) and 34 V/cm injection voltage were applied to the capillary for 3 s. Then the analytes were derivatized during migration in 50 microm ID capillaries filled with 2 mM o-phthalaldehyde (OPA)/N-acetylcysteine (NAC) in a 20 mM phosphate-borate buffer (pH 10), followed by separating and detecting of OPA derivatives by absorbance of 340 nm. Derivatization, separation, and detection were performed systematically using capillaries which varied in length from 5 to 80 cm. In the case of TICD-CE of a mixture containing 1 mM aspartic acid (Asp) and 20 mM m-nitorophenol (MNP) as a test solution, it was determined that peak area and peak width ratios of Asp to MNP did not depend on capillary length. Enantiomeric separations of DL-alanine (Ala) and Asp were examined using a run buffer consisting of a 45 microM beta-cyclodextrin (CD)-2 mM OPA/NAC-20 mM phosphate-borate buffer (pH 10). Even though the resolution of these enantiomeric pairs decreased with decreasing capillary length, as expected, the peaks corresponding to both enantiomeric amino acids were identified even when a 5 cm capillary was used. An 8-component amino acid mixture was also tested with 5 cm and 10 cm capillaries.  相似文献   

17.
A new capillary zone electrophoretic method was developed for the determination of bromide ion in raw and drinking waters. An NaCl-based low-pH buffer caused a reduction of electroosmotic flow (EOF) in the buffer zone, whereas injected water sample resulted in higher EOF in the sample zone thus pumping out the neutral water plug. Sample stacking was used for the preconcentration. The method was applicable for waters from low to intermediate ionic strengths, i.e., the concentration of chloride should preferably be less than 40 mg/l. The method had a limit of detection of 15 micrograms/l at a signal-to-noise ratio of three (S/N = 3) and a limit of quantitation of 20 micrograms/l. CZE results obtained with real samples were compared with ion chromatography--inductively coupled mass spectrometric results.  相似文献   

18.
集成毛细管电泳芯片系统的制作、测试及应用   总被引:7,自引:0,他引:7  
使用标准光刻和化学湿法腐蚀技术,在玻璃板材上制作了由样样管道和分离管道内构成的集成毛细管网路系统,对影响芯片质量的一些因素进行了讨论,并进行了性能测试和评价。芯片上毛细管道散热良好。使用激光诱导荧光和CCD成像检测系统,以电渗作用为驱动力,对混合样品进行了进样、快速分离(20s以内)和监测,证明了自制集成毛细管电泳芯片及检测系统的可行性。比较了两种注样方式(float和pinched)的不同;证明了在分离时可以优化加电策略,防止拖尾,改善峰形。  相似文献   

19.
Natural nanoparticles, including both natural organic matter (NOM) and inorganic mineral-like phases, have been broadly characterized using Flow Field-Flow Fractionation (FlowFFF). Calibration with polystyrene sulfonate (PSS) standards was generally carried out in order to determine the molecular weight distribution of the NOM, however if the analyzed sample has a different charge density compared to the PSS standards, the resulting molecular weight distribution may become meaningless. The presented study therefore investigates and compares the influences of ionic strength and sample load on the retention time and recovery of both PSS standards and natural nanoparticles from a variety of sources. The minimum ionic strength in the carrier solution and the maximum injected sample load required for satisfactory separation depend on the molecular weight of the PSS standards and on the nature of the NOM. The degree to which results depend on conditions and parameters within the FlowFFF varies significantly between the different natural nanoparticle samples. We found that it may be necessary to calibrate the channel under different conditions from the actual sample runs. Under well controlled and documented conditions this could represent an important move away from the paradigm of "same conditions for standards and sample". From all conditions tested, the most reliable molecular weight calibrations were obtained at elevated ionic strengths in the carrier solution (>0.04 M) and low injected mass of PSS. However, even under these optimized conditions variations of up to 20% occur in the calculated molecular weights, and the recovery of NOM falls by up to 50% at high ionic strengths. Many applications aim for both correct molecular weight distribution and the measurement of low concentrations of elements bound to natural nanoparticles. We conclude, however, that finding conditions that are equally optimal for both of these analytical tasks is not always feasible.  相似文献   

20.
Effects of the electric field distribution on microchip valving performance   总被引:2,自引:0,他引:2  
Valving characteristics on microfluidic devices were controlled through manipulation of the electric field strengths during both the sample loading and dispensing steps. Three sample loading profiles for the constant volume valve (pinched injection) in conjunction with four dispensing schemes were investigated to study valving performance. The sample confinement profiles for the sample loading step consisted of a weakly pinched sample, a medium pinched sample, and a strongly pinched sample. Four dispensing schemes varied the electric field strengths in the sample and sample waste channels relative to the analysis channel to control the volume of the sample dispensed from the valve. The axial extent of the sample plug decreased as the electric field strengths in the sample and sample waste channels were raised relative to the analysis channel. In addition, a trade-off existed between sample plug length and sensitivity.  相似文献   