首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 39 毫秒
1.
A technique for imaging materials with short transverse relaxation times and prepared longitudinal magnetization is proposed. The technique is single-point ramped imaging withT1-enhancement (SPRITE) MRI with centrick-space sampling. The effects of transient state behavior on image resolution and signal/noise are estimated. Centric sampling in the basic SPRITE sequence gives increased signal-to-noise and permits a quantitative determination of the MR parameters associated with longitudinal spin preparation. Spin-lock and inversion recovery preparation experiments are presented.  相似文献   

2.
A pure phase-encoding MRI technique, single-point ramped imaging withT1enhancement, SPRITE, is introduced for the purpose of gas phase imaging. The technique utilizes broadband RF pulses and stepped phase encode gradients to produce images, substantially free of artifacts, which are sensitive to the gasT1andT*:2relaxation times. Images may be acquired from gas phase species with transverse relaxation times substantially less than 1 ms. Methane gas images,1H, were acquired in a phantom study. Sulfur hexafluoride,19F, images were acquired from a gas-filled porous coral sample. High porosity regions of the coral are observed in both the MRI image and an X-ray image. Sensitivity and resolution effects due to signal modulation during the time-efficient acquisition are discussed. A method to increase the image sensitivity is discussed, and the predicted improvement is shown through 1D images of the methane gas phantom.  相似文献   

3.
Bubble flow is characterised by numerous phase interfaces and turbulence, leading to fast magnetic resonance signal decay and artefacts in spin-warp imaging. In this paper, the SPRITE MRI pulse sequence, with its potential for very short encoding times, is demonstrated as an ideal technique for studying such dynamic systems. It has been used to acquire liquid velocity and relative intensity maps of two-phase gas–liquid dispersed bubble flow in a horizontal pipe at a liquid Reynolds number of 14,500. The fluids were air and water and a turbulence grid was used to generate a dispersed bubble flow pattern. The SPRITE technique shows promise for future research in gas–liquid flow.  相似文献   

4.
The combination of contrast preparation with centric-scan SPRITE imaging readout is investigated. The main benefit of SPRITE, its ability to image objects with short T2, is retained. We demonstrate T1 and T2 mapping as examples of magnetisation preparation followed by magnetisation storage and spatially resolved encoding. A strategy for selection of the most advantageous imaging parameters for contrast mapping is presented.  相似文献   

5.
The main objective of this article was (i) to refocus the residual dipolar and quadrupolar interactions in anisotropic tissues employing magic sandwich echo (MSE) imaging and to compare the results with that of conventional spin-echo (SE) imaging, and (ii) to quantify MSE relaxation and dispersion characteristics in bovine Achilles tendon and compare with spin-lattice relaxation time constant in the rotating frame (T(1rho)). Magic sandwich echo weighted images are approximately 75-100% higher in signal-to-noise ratio than the corresponding T(2)-weighted images. Magic sandwich echo relaxation times varied from 13+/-2 to 19+/-3 ms (mean+/-S.D.), depending upon the structural location of tendon. T(2) relaxation times only varied from 4+/-1 to 10+/-3 ms (mean+/-S.D.) on the same corresponding locations. Magic sandwich echo provides approximately 100% enhancement in relaxation times compared to T(2). Preliminary results based on bovine Achilles tendon and cartilage specimens suggest that the MSE technique has potential for refocusing residual dipolar as well as quadrupolar interactions in anisotropic systems and yields higher intensities than conventional SE imaging as well as T(1rho)-encoded imaging, especially at low-burst pulse amplitudes (250 and 500 Hz).  相似文献   

6.
Application of the chirp z-transform to MRI data   总被引:1,自引:0,他引:1  
A version of the chirp z-transform (CZT) enabling signal intensity and phase-preserving field-of-view scaling has been programmed. The algorithm is important for all single-point imaging sequences such as SPRITE when used with multiple data acquisition for T2* mapping or signal averaging. CZT has particular utility for SPRITE imaging of nuclei with short relaxation times such as sodium at high field. Here, a complete theory of the properties of CZT is given. This method operates entirely in k-space. It is compared with a conventional interpolation approach that works in image space after the application of a fast Fourier transformation.  相似文献   

7.
In multi-echo imaging sequences like fast spin echo (FSE), the point spread function (PSF) in the phase encoding direction contains significant secondary peaks (sidebands). This is due to discontinuities in adjacent k-space data obtained at different echo times caused by T2 decay, and leads to ghosting and hence reduced image quality. Recently, utilising multiple coils for signal reception has become the standard configuration for MR systems due to the additional flexibility that parallel imaging (PI) methods can provide. PI methods generally obtain more data than is required to reconstruct an image. Here, this redundancy in information is exploited to reduce discontinuity-related ghosting in FSE imaging. Adjacent phase encoded k-space lines are acquired at different echo times alternately in the regions of discontinuity (called ‘feathering’). This moves the resulting ghost artefacts to the edges of the field of view. This property of the ghost then makes them amenable to removal using PI methods. With ‘feathered’ array coil data it is possible to reconstruct data over the region of the discontinuity from both echo times. By combining this data, a significant reduction in ghosting can be achieved. We show this approach to be effective through simulated and acquired MRI data.  相似文献   

8.
We propose the phase diagram of a new pseudo-ternary compound, CoMnGe1-xSnx, in the range x0.1. Our phase diagram is a result of magnetic and calorimetric measurements. We find that the separate magnetic and structural transitions in CoMnGe are tuned together as the level of Sn substitution is increased. We demonstrate the appearance of a hysteretic magnetostructural phase transition in the range x=0.04–0.055, similar to that observed in CoMnGe under hydrostatic pressure. From magnetisation measurements, we show that the isothermal entropy change associated with the magnetostructural transition can be as high as in a field of 1 T. However, the large thermal hysteresis in this transition () will limit its straightforward use in a magnetocaloric device.  相似文献   

9.
Magnetic resonance imaging has rarely been applied to rigid polymeric materials, due primarily to the strong dipolar coupling and short signal lifetimes inherent in these materials. SPRITE (single point ramped imaging withT 1 enhancement) (B. J. Balcom, R. P. MacGregor, S. D. Beyea, D. P. Green, R. L. Armstrong, T. W. Bremner: J. Magn. Reson. A123, 131–134, 1996) is particularly well suited to imaging solid materials. With SPRITE, the only requirement is thatT 2* be long enough so that the signal can be phase-encoded. The minimum phase encoding time is limited by the maximum gradient strength available and by the instrument deadtime. At present this is usually tens of microseconds and will only improve with refinements in technology. We have used the SPRITE sequence in conjunction with raising the sample temperature to obtain images of rigid polymers that have largely frustrated conventional imaging methods. This approach provides a straightforward and reliable method for imaging a class of samples that, up until now, have been very difficult to image.  相似文献   

10.
L. Acedo   《Physica A》2006,370(2):613-624
A stochastic model for epidemic spread in a set of individuals placed upon the sites of a complete graph of relations is investigated. The model is defined by three parameters: the number of individuals or sites, N, the probability that an infected site transmits the disease to a susceptible site, α, and the probability of recovery of infected sites, β, both referred to the unit of time.We show that this system evolves towards a, approximately Gaussian, stationary distribution of infected sites whose mean and variance can be analytically estimated. Also, we find that the average fraction of infected sites, x, is zero for transmission probabilities below the critical value αc=1-e-β/N and grows linearly with α for 0<α-αc1. A sharp peak observed in Monte Carlo simulations of the variance of the number of infected sites as a function of α allows us to classify this dynamical phase transition as second order with x playing the role of an order parameter. Some consequences of this model to the dynamics of highly connected complex systems, such as the brain cortex, are also discussed.  相似文献   

11.
In MR images of porous organic samples (such as roots or wood) in water media, the sample is often surrounded by a bright ring, with a corresponding decreased T1 value in T1 maps. When the medium is removed, or contrast agents are added, the ring disappears, indicating that the signal does not originate in the outer layers of the sample, but from the medium itself. It can be shown that this "bright ring effect" is only observed when the medium experiences a reduction in T1 when permeating the sample. In order to investigate this effect, a computer model was used to simulate the diffusion of magnetisation between regions that exhibit different relaxation constants. Using this model, the origin of the signal increase was found to be an inflow effect, as diffusion transports relaxed magnetisation from the boundary regions of the sample into the surrounding medium. In the case of the "bright ring" around the plants described above, a mixing of short T1 values from within the sample and long T1 values within the medium occurs, yielding a "transition region" between the two values. There, a signal increase can be observed at T1 weighted images, compared to the signal from the medium beyond this transition region. The width of the transition region is on the order of magnitude of the diffusion displacement that is calculated from the T1 value as diffusion time. In addition to causing the bright ring around the plant samples, this diffusion effect also limits the resolution of the relaxation time maps. This effect is not limited to T1 relaxation but also applies to T2 relaxation. However, at high B0 field strengths such as those used in this study (11.7 T), a T2 effect is not usually observed due to the considerably shorter T2 times in plants (about 50 ms, compared to T1 times of higher than 1 s). Because the diffusion length during this T2 relaxation is short with respect to the resolution of the imaging experiments, no T2 ring effect is seen.  相似文献   

12.
Fluid density imaging is highly desirable in a wide variety of porous media measurements. The SPRITE class of MRI methods has proven to be robust and general in their ability to generate density images in porous media, however the short encoding times required, with correspondingly high magnetic field gradient strengths and filter widths, and low flip angle RF pulses, yield sub-optimal S/N images, especially at low static field strength. This paper explores two implementations of pure phase encode spin echo 1D imaging, with application to a proposed new petroleum reservoir core analysis measurement.In the first implementation of the pulse sequence, we modify the spin echo single point imaging (SE-SPI) technique to acquire the k-space origin data point, with a near zero evolution time, from the free induction decay (FID) following a 90° excitation pulse. Subsequent k-space data points are acquired by separately phase encoding individual echoes in a multi-echo acquisition. T2 attenuation of the echo train yields an image convolution which causes blurring. The T2 blur effect is moderate for porous media with T2 lifetime distributions longer than 5 ms. As a robust, high S/N, and fast 1D imaging method, this method will be highly complementary to SPRITE techniques for the quantitative analysis of fluid content in porous media.In the second implementation of the SE-SPI pulse sequence, modification of the basic measurement permits fast determination of spatially resolved T2 distributions in porous media through separately phase encoding each echo in a multi-echo CPMG pulse train. An individual T2 weighted image may be acquired from each echo. The echo time (TE) of each T2 weighted image may be reduced to 500 μs or less. These profiles can be fit to extract a T2 distribution from each pixel employing a variety of standard inverse Laplace transform methods. Fluid content 1D images are produced as an essential by product of determining the spatially resolved T2 distribution. These 1D images do not suffer from a T2 related blurring.The above SE-SPI measurements are combined to generate 1D images of the local saturation and T2 distribution as a function of saturation, upon centrifugation of petroleum reservoir core samples. The logarithm mean T2 is observed to shift linearly with water saturation. This new reservoir core analysis measurement may provide a valuable calibration of the Coates equation for irreducible water saturation, which has been widely implemented in NMR well logging measurements.  相似文献   

13.
Sectoral sampling in centric-scan SPRITE magnetic resonance imaging   总被引:4,自引:4,他引:0  
A new approach to the construction of k-space trajectories for centric-scan SPRITE in both 2D and 3D is presented. All benefits of previous SPRITE methods are retained, most importantly the ability to image objects with short T*(2). This new approach gives more flexibility in the choice of number of interleaves with points more evenly distributed across k-space. All these improvements positively contribute to image quality and resolution, which can be also traded off against experimental speed. Sectoral sampling will have significant benefits for magnetisation preparation contrast imaging.  相似文献   

14.
We present a new version of the 3D TROSY HNCO pulse scheme, referred to as HR-TROSY HNCO, with comparable resolution in the 15N dimension to a 2D 1H–15N HSQC experiment. In the conventional 3D TROSY HNCO, the constant time period (1/2JNC  32 ms) severely limits the maximum resolution in the 15N dimension. In the HR-TROSY HNCO experiment presented here, both constant time periods (32 ms each) for coherence forward and backward transfer between 15N and 13C′ are utilized to double the 15N evolution time. This leads to a dramatic enhancement in peak separation along the 15N dimension, making the HR-TROSY HNCO an ideal pulse scheme for accurate paramagnetic relaxation enhancement and residual dipolar coupling measurements.  相似文献   

15.
The single-point ramped imaging with T1 enhancement (SPRITE) imaging technique has proven to be a very robust and flexible method for the study of a wide range of systems with short signal lifetimes. As a pure phase encoding technique, SPRITE is largely immune to image distortions generated by susceptibility variations, chemical shift and paramagnetic impurities. In addition, it avoids the line width restrictions on resolution common to time-based sampling, frequency encoding methods. The standard SPRITE technique is however a longitudinal steady-state imaging method; the image intensity is related to the longitudinal steady state, which not only decreases the signal-to-noise ratio, but also introduces many parameters into the image signal equation. A centric scan strategy for SPRITE removes the longitudinal steady state from the image intensity equation and increases the inherent image intensity. Two centric scan SPRITE methods, that is, Spiral-SPRITE and Conical-SPRITE, with fast acquisition and greatly reduced gradient duty cycle, are outlined. Multiple free induction decay (FID) points may be acquired during SPRITE sampling for signal averaging to increase signal-to-noise ratio or for T2* and spin density mapping without an increase in acquisition time. Experimental results show that most porous sedimentary rock and concrete samples have a single exponential T2* decay due to susceptibility difference-induced field distortion. Inhomogeneous broadening thus dominates, which suggests that spin density imaging can be easily obtained by SPRITE.  相似文献   

16.
The dependence of the residual polarization of negative muons in p-type Si on temperature in the 4.2–270 K range has been investigated. Measurements were carried out in external magnetic field of 0.08 T transverse to the muon spin. The impurity concentration in the sample was 2 · 1013 cm–3. Muon spin relaxation was observed at temperatures below 30 K. The relaxation rate atT=30 K is equal to 0.18±0.08s–1. The relaxation rate grows with the decrease of temperature and at 4.2 K exceeds 30s–1. The value of the residual polarization at zero timeP(t=0) is constant within the investigated temperature range.In the rangeT<30 K data on the relaxation rate are well described by the dependence =B·T–q, whereq=2.75. Power dependence of may evidence the essential role of the phonon mechanism in the relaxation of the electron momentum of the acceptor center.The authors express their gratitude to V.B. Brudanin and I.A. Yutlandov for providing the sample, and to Yu.B. Gurov for advices.  相似文献   

17.
In this communication we present a method for single-slice mapping of ultrashort transverse relaxation times T(2). The RF pulse sequence consists of a spin echo preparation of the magnetization followed by slice-selective ultrashort echo time (UTE) imaging with radial k-space sampling. In order to keep the minimum echo time as small as possible, avoid out-of-slice contamination and signal contamination due to unwanted echoes, the implemented pulse sequence employs a slice-selective 180° RF refocusing pulse and a 4-step phase cycle. The slice overlap of the two slice-selective RF pulses was investigated. An acceptable Gaussian slice profile could be achieved by adjusting the strength of the two slice-selection gradients. The method was tested on a short T(2) phantom consisting of an arrangement of a roll of adhesive tape, an eraser, a piece of modeling dough made of Plasticine?, and a 10% w/w agar gel. The T(2) measurements on the phantom revealed exponential signal decays for all samples with T(2)(adhesive tape)=(0.5 ± 0.1)ms, T(2)(eraser)=(2.33 ± 0.07)ms, T(2)(Plasticine?)=(2.8 ± 0.06)ms, and T(2)(10%agar)=(9.5 ± 0.83)ms. The T(2) values obtained by the mapping method show good agreement with the T(2) values obtained by a non-selective T(2) measurement. For all samples, except the adhesive tape, the effective transverse relaxation time T(2)(?) was significantly shorter than T(2). Depending on the scanner hardware the presented method allows mapping of T(2) down to a few hundreds of microseconds. Besides investigating material samples, the presented method can be used to study the rapidly decaying MR-signal from biological tissue (e.g.: bone, cartilage, and tendon) and quadrupolar nuclei (e.g.: (23)Na, (35)Cl, and (17)O).  相似文献   

18.
Macroscopic samples of near-surface water in pores or fractures of rocks down to 100 m and deeper are studied by the measurement of proton relaxation and echo in the Earth’s magnetic field. The excitation and reception of the surface nuclear magnetic resonance (SNMR) signal is accomplished with the help of an antenna, circle or 8-shaped (for the minimization of the outer electromagnetic jamming influence), placed at the surface. The frequency of magnetic resonance in the case considered amounts to several kilohertz, the dead time of the instrumentation to several milliseconds. Water in extremely small pores of water-resisting rocks (e.g., in argillaceous grounds), is chemically bound, crystallization or frozen water has smaller times of spin relaxation and is not registered. The distribution of water concentration with depth is determined by inversion of an integral equation, including the model and measured dependences of the SNMR signal against the intensity of excitation. The current state of the art of the SNMR sounding and perspectives of this method on the basis of free induction decay and spin echo detection and relaxation times measurement are presented. Free induction decayT 2 * equal to 60 ms, spin-echoT 2 equal to 220 ms, and inversion-recoveryT 1 equal to 700 ms relaxation times have been measured for medium-to coarse-grained sand aquifer. Microscopic characteristics of the aquifer — longitudinal relaxivity (7·10?3 cm/s), transverse relaxivity (3.5·10?2 cm/s), and local magnetic field gradient (2·10?2 G/cm) — have been estimated from experimental data. The importance of spin relaxation and echo measurements for obtaining the information about the microstructure of pores and fractures, as well as filtration, properties of aquifers and diamagnetic, paramagnetic and hydrocarbon contamination, is emphasized.  相似文献   

19.
Single point imaging methods such as SPRITE are often the technique of choice for imaging fast-relaxing nuclei in solids. Single point imaging sequences based on SPRITE in their conventional form are ill-suited for in vivo applications since the acquisition time is long and the SAR is high. A new sequence design is presented employing variable repetition times and variable flip angles in order to improve the characteristics of SPRITE for in vivo applications. The achievable acquisition time savings as well as SAR reductions and/or SNR increases afforded by this approach were investigated using a resolution phantom as well as PSF simulations. Imaging results in phantoms indicate that acquisition times may be reduced by up to 70% and the SAR may be reduced by 40% without an appreciable loss of image quality.  相似文献   

20.
We report on electrical relaxation measurements of (1 − x)NH4H2PO4-xTiO2 (x = 0.1) composites by admittance spectroscopy, in the 40-Hz–5-MHz frequency range and at temperatures between 303 and 563 K. Simultaneous thermal and electrical measurements on the composites identify a stable crystalline phase between 373 and 463 K. The real part of the conductivity, σ’, shows a power-law frequency dependence below 523 K, which is well described by Jonscher’s expression , where σ 0 is the dc conductivity, ω p /2π = f p is a characteristic relaxation frequency, and n is a fractional exponent between 0 and 1. Both σ 0 and f p are thermally activated with nearly the same activation energy in the II region, indicating that the dispersive conductivity originates from the migration of protons. However, activation energies decrease from 0.55 to 0.35 eV and n increases toward 1.0, as the concentration of TiO2 nanoparticles increases, thus, enhancing cooperative correlation among moving ions. The highest dc conductivity is obtained for the composite x = 0.05 concentration, with values above room temperature about three orders of magnitude higher than that of crystalline NH4H2PO4 (ADP), reaching values on the order of 0.1 (Ω cm) − 1 above 543 K.  相似文献   