首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 156 毫秒
1.
本文以肉桂酸甲酯、水合肼及水杨醛为原料,设计合成了一种“turn-on”型离子选择性荧光探针,采用NMR、IR及HRMS对其结构进行了表征,结果表明该探针为N’-[(2-羟苯基)亚甲基]-3-{2-[(2-羟苯基)亚甲基]肼-1-基}-3-苯丙酰肼(ZL)。基于其存在的酰基和邻羟苯基亚甲基胺结构,研究了其对不同金属离子的识别作用,结果Zn2+、Mg2+和Cd2+对探针ZL荧光表现出“turn-on”效应,其荧光分别增强了47、21、24倍,而其他金属离子对其荧光光谱及强度无影响,化合物ZL表现出对Zn2+、Mg2+和Cd2+的高选择性识别和高灵敏检测,其检出限分别为5.5nmol·L-1、8.4nmol·L-1、9.9 nmol·L-1。通过Job’s plot实验表明ZL与Zn2+、Mg2+和Cd2+的结合比为1∶1,结合核...  相似文献   

2.
本文以KMnO4改性处理的柏树锯末为吸附剂,对溶液中的Cu2+吸附去除。结果表明,改性锯末增大了孔径和比表面积,吸附剂表明吸附位点增多,当pH=7、吸附剂用量1 g·L-1及温度318 K的条件下吸附效果最佳。改性柏树锯末对Cu2+的吸附动力学和等温线线性拟合结果分别符合准二级动力学方程和Langmuir吸附等温模型,说明该吸附过程是单分子层吸附,并以化学吸附为主。  相似文献   

3.
为实现从低浓度稀土溶液中高效富集稀土,通过动态吸附-解吸试验,研究了转型TP207树脂吸附稀土的规律。系统考察了离子交换线速度、吸附液体积、初始p H值、铝离子对树脂吸附稀土容量的影响,以及解吸液体积对稀土解吸率的影响。结果表明:在稀土浓度为1.65g·L-1,离子交换线速度为3 cm·min-1,吸附液体积为7.50 L,初始p H值为3.46的条件下,TP207树脂对稀土吸附量Qn1=0.18 g·g-1;稀土溶液中铝和稀土存在竞争吸附,当Al3+浓度为0.35 g·L-1时,TP207树脂对稀土吸附量Qn2降为0.11 g·g-1;采用5%的稀HCl对饱和树脂进行解吸,在解吸液体积为0.525 L时,稀土解吸率可达99.45%;树脂吸附稀土过程属于阳离子交换反应,符合Langmuir等温吸附模型,为单分子层吸附,树脂中C=O的O原子和C-N的N原子均参与配位反应。  相似文献   

4.
本文研究了向日葵盘中的天然低酯化果胶对水溶液中镉离子(Cd2+)的吸附作用,考察了果胶添加量、果胶溶液的pH值、温度、吸附时间、共存离子对Cd2+吸附量和去除率的影响。随果胶添加量的增加,Cd2+的去除率从2.25%逐渐升高至14.60%,而吸附量则先从18.00mg/g增加至20.53mg/g,后逐渐降低至5.84mg/g;随果胶溶液pH值的升高,吸附量和去除率先分别增加至20.70mg/g和15.53%,后逐渐降低;随温度的升高,吸附量和去除率分别增加至20.80mg/g和15.60%后几乎不变;反应10min吸附量和去除率即可达到最大,分别为19.81mg/g和14.75%。此外,溶液中的Ca2+也会影响果胶的吸附作用,当Ca2+与Cd2+的质量比为2时,吸附量和去除率降低了36.70%。确定了向日葵盘果胶吸附Cd2+的最佳条件:当溶液中Cd2+的浓度为8.0mg/L时,添加等体积80mg/L的pH值为8....  相似文献   

5.
新型薄膜扩散梯度装置定量测量水环境中重金属形态   总被引:1,自引:0,他引:1  
采用以纤维素透析膜为扩散相, 0.05 mol/L羧甲基纤维素钠(CMC)溶液为结合相的薄膜扩散梯度(DGT)装置(CMC-DGT)定量累积和测量水溶液中Cu2+, Cd2+和Pb2+的有效态; 考察了pH值和离子强度对CMC-DGT累积Cu2+, Cd2+和Pb2+的影响以及不同配体(乙二胺四乙酸二钠、 单宁酸和黄腐酸)对重金属有效态的影响; 测量了外加标的天然水和工业废水中重金属的有效态浓度; 并比较了不同结合相DGT装置对同一水体中重金属的有效态浓度. 实验结果表明, 0.05 mol/L CMC溶液对Cu2+, Cd2+和Pb2+累积容量分别为0.24, 0.11和0.45 mg/mL; 定量累积的最佳pH值范围分别为3.7~8.0, 4.7~9.0和4.7~8.0; 随着离子强度的增大, CMC-DGT对Cu2+, Cd2+和Pb2+的累积容量下降; CMC-DGT能够定量地累积配制水中的游离Cu2+, Cd2+和Pb2+, 回收率分别为92.1%, 100.6%和96.4%; 当有配体存在时, 随着配体浓度的增大, CMC-DGT测量的Cu2+, Cd2+和Pb2+有效态的浓度随之下降; 在过滤工业废水、 河水和湖水中, 不同结合相DGT装置对重金属有效态的测量值不同. 结果表明, CMC可作为DGT技术新的液态结合相.  相似文献   

6.
以Fe3O4@SiO2为磁核,在其表面包裹壳聚糖,再通过分子印迹技术,制得Fe3O4@SiO2@CTS镍离子印迹聚合物。采用XRD、FTIR和SEM对镍离子印迹聚合物的结构和形貌进行表征。通过正交实验确定了镍离子印迹聚合物对Ni2+的最佳吸附条件为:Ni2+初始浓度为80 mg·L-1、印迹聚合物用量为25 mg、pH值为5.0、吸附时间为3 h,印迹聚合物对Ni2+的吸附量可达66.73 mg·g-1。Fe3O4@SiO2@CTS镍离子印迹聚合物对Ni2+的吸附符合拟二级动力学方程,吸附过程符合Freundlich等温吸附模型。  相似文献   

7.
对铅、镉和钠在Chelex-100树脂上于不同pH值的介质中的分配系数(Kd)和吸附容量进行了研究。结果表明:在pH 1~8的介质中Na+的Kd<3,即在Chelex-100树脂上无吸附;在pH>4的介质中,Pb2+和Cd2+的Kd>104,即强吸附于Chelex-100树脂上;而用0.16 mol·L-1硝酸溶液可将吸附于树脂上的Pb2+和Cd2+完全洗脱下来。在此基础上提出了一种Chelex-100树脂分离原子吸收光谱法测定高盐食品中重金属元素含量的方法。方法用于高盐食品分析,加标回收率在93.1%~102%之间,测定值的相对标准偏差(n=5)在0.5%~3.4%之间。  相似文献   

8.
黄水波  张朝晖  周必武  赵承峰 《应用化学》2015,32(11):1299-1306
以苯胺修饰的磁性碳纳米管为基质,Cd2+为模板,甲基丙烯酸为功能单体,乙二醇二甲基丙烯酸酯为交联剂,在碳纳米管表面制备出一种新型磁性Cd2+印迹聚合物(MWNTs/MIIPs)。 采用扫描电子显微镜和红外光谱等技术手段对其形态和化学结构等进行详细表征。 吸附试验结果表明,该磁性印迹材料对Cd2+离子具有良好的吸附能力,最大吸附量为16.96 mg/g;选择吸附试验结果表明,该磁性印迹材料对Cd2+/Cu2+、Cd2+/Ni2+、Cd2+/Pb2+和Cd2+/Cr3+的相对选择因子分别是2.03、2.35、2.16和2.13。 结合原子吸收光谱分析技术,该材料MWNTs/MIIPs可用于大米中的Cd2+快速分离富集检测。  相似文献   

9.
采用氨基-过硫酸盐氧化还原引发体系, 先实现了甲基丙烯酸羟乙酯(HEMA)在微米级硅胶微粒表面的引发接枝聚合, 制得高接枝度的接枝微粒PHEMA/SiO2. 然后使接枝大分子PHEMA的侧羟基与5-氯-8-羟基喹啉(CHQ)发生亲核取代反应, 将8-羟基喹啉(HQ)基团键合在接枝大分子侧链, 使接枝大分子PHEMA实现8-羟基喹啉功能化转变, 制得表面含有高密度HQ基团的功能接枝微粒HQ-PHEMA/SiO2, 考察研究了功能微粒HQ-PHEMA/SiO2对Cd2+离子的强螯合吸附作用. 在此基础上, 采用本课题组建立的新的分子表面印迹技术, 以Cd2+离子为模板离子, 二氯乙醚为交联剂, 对接枝在硅胶表面的功能大分子链HQ-PHEMA进行了离子印迹, 制备了Cd2+离子表面印迹材料IIP-HQP/SiO2, 深入考察研究了其离子识别与结合特性. 实验结果表明, 该离子表面印迹材料对Cd2+离子具有特异的识别选择性与优良的结合亲和性, 相对于Cu2+和Pb2+两种对比离子, 印迹材料IIP-HQP/SiO2对Cd2+离子的识别选择性系数分别高达25.52和22.91, 显示出超高的离子识别能力.  相似文献   

10.
利用H2O2-Fe2+可以快速使丁基玫瑰红B(BRMB)发生荧光猝灭,而过氧化氢酶(CAT)对该猝灭有抑制效应,提出了基于H2O2-BRMB-Fe2+体系的荧光猝灭法测定血清CAT活性的方法。取血清样品10μL,加入1 mmol·L-1 H2O2底液0.50 mL,于30℃恒温反应15 min,再依次加入0.02 mmol·L-1 BRMB溶液0.70 mL、0.1 mol·L-1冰乙酸-乙酸钠缓冲液(pH 4.2)1.00 mL和0.01 mol·L-1 Fe2+溶液0.08 mL,于室温反应20 min后用水定容至10 mL,测定体系在590 nm发射波长处的荧光强度F;以煮死酶液为对照,按照同样的方法测定其在590 nm发射波长处的荧光强度F0。结果表明:CAT活性在0.005...  相似文献   

11.
利用锌诱导小球藻,通过提取分离和纯化,获得锌结合类金属硫蛋白(MT-like蛋白).通过透析过程,研究模拟胃、肠道消化液中MT-like蛋白对Cd2+的结合作用.结果表明,在模拟胃液中MT-like蛋白处于脱金属状态,与Cd2+的结合能力弱.而在肠消化液中,MT-like蛋白能与Cd2+结合,20 mg·L-1 MT-...  相似文献   

12.
Na-A zeolite was successfully synthesized via the alkaline fusion method with oil shale ash as the raw material. The adsorption capacity of it was tested by removing Cu2+, Ni2+, Pb2+ and Cd2+ from aqueous solutions. The results reveal the maximum adsorption capacity of adsorbent for Pb2+, Cu2+, Cd2+ and Ni2+ were 224.72, 156.74, 118.34 and 53.02 mg/g, respectively. The effects of contact time and pH value of solutions on the adsorption efficiency of the zeolite were evaluated. Besides, The equilibrium adsorption data and the batch kinetic data were correlated with Langmuir and Freundlich models and the pseudo-first-order and pseudo-second-order models separately. The results show that the Langmuir isotherm and the pseudo-second-order equation were more suitable for the adsorption of Na-A zeolite for the metal ions. In addition, Thermodynamic parameters of the adsorption(the Gibbs free energy, entropy, and enthalpy) were also evaluated and discussed. The results demonstrate that the adsorption process was spontaneous and endothermic under natural conditions and the synthesized zeolite was an effective adsorbent for the removal of metal ions from aqueous solution.  相似文献   

13.
采用滴涂法在铂基底制备了电活性聚苯胺-磷酸锡(PANI-SnP)复合膜电极,考察了该电极在Ni2+、Cd2+溶液的电控离子交换性能. 用傅立叶变换红外光谱和扫描电镜分析观察复合膜的组成及表面形貌;在0.1 mol·L-1 Ni(NO3)2、Cd(NO3)2溶液,通过循环伏安法比较了PANI膜、SnP膜及PANI-SnP复合膜电极的电化学性能,并结合电化学石英晶体微天平技术重点考察了PANI-SnP复合膜的离子交换机制;同时,通过循环伏安法调控复合膜电极的氧化还原电位,结合X射线能谱和X射线光电子能谱分别测定了其氧化和还原状态的元素组成. 结果表明,PANI-SnP复合膜电极在Ni2+、Cd2+溶液均有良好的氧化还原电活性和可逆离子交换性能,其Cd2+离子选择性优于Ni2+离子,通过电控离子交换可使Cd2+离子从镍镉废水高效分离.  相似文献   

14.
核电站放射性废液组成复杂,其中137Cs、90Sr和60Co是放射性废液处理的主要目标。 本文采用稳定同位素模拟放射性废液,研究了Cs+离子在强酸性阳离子树脂IRN97中的交换等温线、动力学特性以及固定床穿透行为,探讨了共存的硼酸和Sr2+、Co2+等核素离子对Cs+离子交换行为的影响。 结果表明,废液中存在的高浓度硼酸在一定程度上会减小树脂对Cs+的交换量;与共存的Sr2+和Co2+离子相比,虽然Cs+的交换速率快,但树脂对Sr2+和Co2+的选择性更高,因此在达到交换平衡状态下,Sr2+和Co2+的交换容量大于Cs+;在采用固定床吸附柱进行的动态吸附中,提高Cs+的进水浓度可以提高树脂的利用率。  相似文献   

15.
石墨粉氧化后,在氮气气氛下,快速高温剥离制得石墨烯纳米片。采用X射线衍射(XRD)、扫描电子显微镜(SEM)、透射电子显微镜(HRTEM)、拉曼(Raman)光谱、傅里叶变换红外(FT-IR)光谱和氮气吸附-脱附等分析手段对石墨烯样品进行了表征。这些分析测试结果显示:石墨烯样品主要由很薄的1-4层石墨组成,呈褶皱状态,比表面积为628.5 m2·g-1。研究了石墨烯吸附水溶液中的Pb2+和Cd2+的pH值、吸附时间、吸附温度和金属离子初始浓度等影响因素, Pb2+和Cd2+的最大吸附量分别为460.20和72.39 mg·g-1。结果表明,热剥离法制得的高质量石墨烯纳米片可以作为一种高效的从水中去除Pb2+和Cd2+的吸附材料。  相似文献   

16.
An electrochemical sensor based on self-made nano-porous pseudo carbon paste electrode (nano-PPCPE) has been successfully developed, and used to detect Cd2+ and Pb2+. The results showed that the electrodes can quantitatively detect trace Cd2+ and Pb2+, and with satisfied limit of detection, which has great significance in electrochemical analysis and detection.  相似文献   

17.
建立了一种以牛血清白蛋白功能化的金纳米棒(BSA-Cys-GNRs)为荧光探针检测Hg2+的新方法。以半胱氨酸作为连接臂成功将牛血清白蛋白修饰在金纳米棒表面,通过紫外可见吸收光谱、荧光光谱、红外光谱和荧光倒置显微镜等多种分析方法对材料进行表征。研究发现,在295nm波长光激发下,BSA-Cys-GNRs探针在338nm显示强荧光,而Hg2+能够有效地猝灭BSA-Cys-GNRs的荧光。对一系列影响猝灭效果的因素进行考察,得出pH 4.0、孵育时间5.0min为最佳检测条件。Mn2+、K+、Ni2+、Na+、Cr3+、Cd2+、Mg2+、Cu2+、Ca2+、Al3+和Zn2+对BSA-Cys-GNRs的荧光信号没有明显的影响。当Hg2+的浓度为0.04444~8.888μmol·L-1时,荧光猝灭效率与Hg2+的浓度之间存在良好的线性关系,检测限为8.08nmol·L-1。将该方法用于环境水样中Hg2+的检测,回收率为98.9%~105.0%。  相似文献   

18.
彭维  李杰  程舸  谢珍珍  石磊 《应用化学》2015,32(11):1307-1311
通过钨离子印记方法,合成了对铜离子有高选择性吸附性能的碳基材料。 在四乙烯五胺(TEPA)、钨酸铵和葡萄糖摩尔比为1:1:5条件下,经水热法合成的碳基吸附材料能有效地吸附铜离子,对铜离子吸附的最佳pH=5。 在Cd2+、Co2+、Cu2+、Ni2+和Zn2+摩尔浓度相近体系中,离子印记碳基吸附材料对铜离子的吸附率高达97.2%,而对Cd2+、Co2+、Ni2+、Zn2+吸附率分别为20.1%、9.63%、20.3%、13.3%,表明这种离子印记碳基吸附材料对Cu2+具有非常优异的选择吸附能力。  相似文献   

19.
At present, heavy metal pollution has become a major environmental problem, influencing the survival of human and other creatures. Developing heavy metal ion adsorbents, which are environment friendly, of low cost and good performance is one of the effective means to solve heavy metal pollution. Rich low-grade diatomite mineral, as raw material, was modified with calcium carbonate to improve the adsorption properties of diatomite for heavy metal ions. The effects of dosage(m), pH, adsorbing time(t), temperature(T) and concentration of adsorbent(c) on the removal rate of heavy metal ions(Cu2+, Pb2+, Zn2+ and Cd2+) were studied. The results show that under the suitable conditions, T=15 ℃, c=1.5 mmol/L, m=10 g/L, t=60 min, in a weak acid environment, the removal effect of the four kinds of metal ions by modified diatomite is the best.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号