首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple and sensitive method is described for determination of jasmonic acid (JA) in plant tissues. The method is based on derivatization of JA with 5-bromomethylfluorescein (5-BMF) and separation and quantification of the resulting 5-BMF–JA derivative by capillary electrophoresis coupled to laser-induced fluorescence detection (CE–LIF). The derivatization conditions were studied in detail. Our results indicated that 5-BMF-labeled JA could be well separated from other plant hormones present in the sample by use of 20 mmol L–1 borate buffer (pH 8.5). The response to JA was a linear function of concentration in the range 1 to 100 mol L–1, with a correlation of 0.9986. Our preliminary work showed that the proposed method had fairly good selectivity and sensitivity. Only small amounts of plant sample are needed to complete the analysis. This described method enables the analysis of JA in crude extracts without extra purification and enrichment procedures.  相似文献   

2.
Summary A method based on micellar electrokinetic chromatography has been developed for the simultaneous separation of six anthocyanins (malvidin-3,5-diglucoside, malvidin-3-glucoside, malvidin-3-galactoside, pelargonidin-3-glucoside, cyanidin-3,5-diglucoside, cyanidin-3-galactoside). Optimum selectivity was achieved in the buffer 30 mM phosphate + 400 mM borate-TRIS, pH=7.0 supported with 50 mM sodium dodecylsulphate. High content of borate was essential mainly for the separation of diastereomeric pair malvidin-3-glucoside-malvidin-3-galactoside. The calibration dependencies exhibit good linearity in the ranges of concentration 10–100 g mL–1 for diglycosylated and 25–100 g mL–1 for monoglycosylated derivatives (R2 = 0.9711–0.9989). The optimized method was applied to a sample of wine grape skin extract. Malvidin-3-glucoside was identified as main anthocyanin colorant in this sample.  相似文献   

3.
A reliable and reproducible method, capillary zone electrophoresis with amperometric detection (CZE–AD), has been developed for separation and quantification of levodopa methyl ester (LDME) and its biotransformation products levodopa (L-DOPA) and dopamine (DA) in rat serum. A carbon-disk electrode was used as working electrode. The optimum conditions for CZE detection were 50 mmol L–1 phosphate solution at pH 7.0 as running buffer, 17 kV as separation voltage, 1.0 V (vs Ag/AgCl, 3.0 mol L–1) as detection potential, and sample injection for 8 s at 17 kV. The linear ranges were from 2.4×10–2 to 2.2 g mL–1 for LDME, 2.9×10–1 to 49.5 g mL–1 for L-DOPA, and 1.4×10–2 to 1.5 g mL–1 for DA with correlation coefficients of 0.9997, 0.9994, and 0.9999, respectively. The detection limits for LDME, L-DOPA, and DA were 14.6, 98.0, and 9.7 ng mL–1, respectively. Recoveries were 80.3% for LDME, 93.5% for L-DOPA, and 86.5% for DA. This method was applied to serum samples after intravenous injection of LDME and L-DOPA to rats.  相似文献   

4.
A high-performance capillary electrophoresis with electrochemical detection (CE-ED) method has been employed for the determination of six bioactive ingredients in traditional Chinese herbs, Herba cepbalanoplosis segeti and Herba cirsii japonici. The effects of several factors such as the acidity and concentration of running buffer, the separation voltage, the applied potential and the injection time on CE-ED were investigated. Under the optimum conditions, the six analytes could be well separated within 21 min in a 75 cm length capillary at the separation voltage of 15 kV in a 50 mmol L–1 borax running buffer (pH 8.4). A 300 m diameter carbon disk electrode was used as the working electrode positioned carefully opposite the outlet of the capillary in a wall-jet configuration at potential of +950 mV (vs. SCE). Good linear relationship was established between peak current and concentration of analytes over two orders of magnitude with detection limits (S/N=3) ranged from 1.5×10–7 to 6.0×10–7 g mL–1 for all six analytes. This proposed method has been successfully applied for the analysis of traditional Chinese herbs after a relatively simple extraction procedure, further on, for the differentiation of these above two seemingly identical herbs based on their electropherograms or characteristic electrochemical profiles.  相似文献   

5.
A method for separation of four environmentally important compounds (three alkylphenols and bisphenol A) by cyclodextrin-modified reverse-migration micellar electrokinetic chromatography (CD-RM-MEKC) has been optimized. On-line concentration, stacking using reverse-migrating micelles and a water plug (SRW), was used to improve the limit of detection. Two main factors affecting the efficiency of enhancement by SRW, injection sample length and water-plug length, are discussed in detail. Compared with the normal 2-s injection, more than 121-fold enhancement of peak area and more than 71-fold enhancement of peak height were achieved with 120-s sample injection after 120-s water-plug injection. With this optimized separation method and SRW technology, limits of detection were found to be 0.089, 0.030, 0.0091, and 0.033 mg L–1 for 4-nonylphenol, 4-tert-octylphenol, bisphenol A, and 4-tert-butylphenol, respectively. Calibration plots (R2 0.9968) and relative standard deviations (RSD, %) of corrected peak areas and migration time were also satisfactory. Combined with off-line concentration by solid-phase extraction (SPE) this method might be used to determine these contaminants at ppb levels in groundwater samples.  相似文献   

6.
The present work reports for the first time a simple and rapid method for the spectrofluorimetric determination of lisinopril (LSP) in pharmaceutical formulations using sequential injection analysis (SIA). The method is based on reaction of LSP with o-phthalaldehyde (OPA) in the presence of 2-mercaptoethanol (borate buffer medium, pH=10.6). The emission of the derivative is monitored at 455 nm upon excitation at 346 nm. The various chemical and physical conditions that affected the reaction were studied. The calibration curve was linear in the range 0.3–10.0 mg L–1 LSP, at a sampling rate of 60 injections h–1. Consumption of OPA reagent was significantly reduced compared with conventional flow injection (FI) systems, because only 50 L of OPA was consumed per run. The method was found to be adequately precise (sr=2% at 5 mg L–1 LSP, n=10) and the 3 detection limit was 0.1 mg L–1. The method was successfully applied to the analysis of two pharmaceutical formulations containing LSP. The results obtained were in good agreement with those obtained by use of high-performance liquid chromatography (HPLC), because the mean relative error, er, was <1.8%.  相似文献   

7.
A cyclodextrin-modified micellar electrokinetic chromatography separation for 18 different pesticides (metsulfuron-methyl, rimsulfuron, thifen-sulfuron-methyl, desethylatrazine, desisopropylatrazine, atrazine, simazine, terbuthylazine, 2,4-D, MCPP, MCPB, dicamba, linuron, alachlor, metolachlor, orbencarb, propiconazole, prochloraz) from eight different substance classes with very varying chemical and physical properties is presented. In particular acid-base characteristics and water-octanol distribution coefficients diverge in wide ranges. -cyclodextrin was successfully employed as a modifier in separating the hydrophobic analytes. Peak distortion of some neutral analytes, which is devoted to the methanol content of the sample zone, was reduced by increasing the SDS concentration. Methanol in the sample is necessary for a better solubility of the hydrophobic pesticides. Few optima of SDS concentration exist allowing the separation of sulfonylureas as well as phenoxy acids and hydrophobic pesticides. An improved resolution of the sulfonylureas was achieved with tetramethylammonium chloride, which was used as an ion-pairing reagent.Final operating conditions for the separation of all these plant protectant compounds by MEKC in just one single run are a 27 mmolL–1 phosphate buffer, pH 8.03, with 95 mmolL–1SDS, 5 mmolL–1 -cyclodextrin and 10 mmol L–1 tetramethylammonium-chloride.  相似文献   

8.
A simple and rapid micellar electrokinetic capillary chromatographic (MEKC) method for analysis of rofecoxib (ROF) and its photodegradation product (PDP) in pharmaceutical preparations has been developed and validated. Analyses were conducted in a fused silica capillary (72 cm effective length, 50 m i.d.) with a background electrolyte consisting of 25 mmol L–1 borate buffer at pH 7.0 containing 15 mmol L–1 sodium dodecyl sulfate (SDS) and 10% acetonitrile (ACN). The separation was performed by voltage-controlled system, applying 30 kV at 30 °C, detecting at 225 nm; injection was hydrodynamic at 50 mbar for 2 s. Nifedipine was used as internal standard (IS). Under the optimum conditions ROF, PDP, and IS were well separated with in 10 min. The method was validated with regard to linearity, limit of detection and quantitation, precision, accuracy, specificity, and robustness. The detection limit of the method was low, 0.8 g mL–1, and the linearity range was wide, 2.5 to 125 g mL–1. The method was highly efficient—5×105 plates m–1 for ROF. The method was applied to the tablet form of ROF-containing pharmaceutical preparations. The data were compared with those from the voltammetric method described in literature. No statistically significant difference was found.  相似文献   

9.
Pfeffer  M.  Walenciak-Reddel  E. 《Chromatographia》1994,38(7-8):479-484
Summary A high-performance liquid chromatographic method is discribed for the determination of 6-amino-2,2-dimethyl-1,3-dioxepan-5-ol using Spherisorb ODS II stationary phase and mobile phase 30:70 (v/v) methanol: aqueous 1-octane sulfonic acid. Detection was fluorimetric following postcolumn derivatization with o-phthaladehyde/2-mercaptoethanol. The procedure was applied to the analysis of aqueous solutions and microcrystalline suspensions in liquid paraffin, prepared for investigation of the toxicological profile. The method was validated for selectivity, linearity of detector response, repeatability, limit of detection and quantitation. The HPLC method was selective. The instrumental limit of detection was 0.5 ng per injection (0.05 g mL–1). The method detection limits were 0.5 g mL–1 aqueous solution and 5 g mL–1 liquid paraffin suspension, the quantitation limit 0.05 mg mL–1 aqueous solution and 1.0 mg mL–1 liquid paraffin. Linearity was within 0.94–47.1 g mL–1. Intra-assay accuracy accounted for 99–100% in the range 0.05–226 mg mL–1 aqueous solution, intra-assay precision for 2% (C.V.). For microcrystalline liquid paraffin suspensions with 1 and 250 mg mL–1 99 and 109% was found for intra-assay accuracy. Intra-assay precision was 5% (C.V.). Reliable results over a wide concentration range can be obtained. The procedure is considered valid for determination of the analyte in aqueous solution or microcrystalline paraffin oil suspensions.  相似文献   

10.
A selective complexometric method is described for the determination of palladium, sodium nitrite being used as masking reagent. Palladium(II) in a given sample solution is initially cornplexed with an excess of EDTA and the surplus EDTA is titrated with zinc sulfate solution at pH 4.5–5.5 (acetic acid-sodium acetate buffer), using xylenol orange as indicator. An excess of sodium nitrite is then added, the mixture is shaken well and the EDTA released from the Pd-EDTA complex is titrated with a standard zinc sulfate solution. Results are obtained for 2.5–27.5 mg of Pd with relative errors 0.5% and standard deviations 0.05 mg. The interferences of various ions are studied. The method is applied for the determination of palladium(II) in alloys and complexes.  相似文献   

11.
A fast and simple micellar electrokinetic capillary chromatographic method was developed for the analysis of piribedil in pharmaceutical formulations. The effects of buffer concentration, buffer pH, sodium dodecyl sulphate (SDS) concentration, organic modifier, applied voltage and injection time were investigated. Optimum results were obtained with a 50 mM borate buffer at pH 8.0 containing 50 mM SDS by using a fused silica capillary (50 m internal diameter, 72 cm effective length). The sample was injected hydrodynamically for 4 s at 50 mbar pressure and the applied voltage was +30 kV. The detection wavelength was set at 205 nm. Diflunisal was used as an internal standard. The analysis was performed at 25 °C and the total run time was 14 min. The method was suitably validated with respect to linearity range, limit of detection and quantification, precision, accuracy, specificity and robustness. The linear calibration range was 5–100 g mL–1 and the limit of detection was determined as 1 g mL–1. The method developed was successfully applied to the determination of piribedil in pharmaceutical formulations. The results were compared with a spectrophotometric method reported in the literature and no significant difference was found statistically.  相似文献   

12.
A simple capillary zone electrophoresis (CZE) method has been developed for analyzing seven nonsteroidal anti-inflammatory drugs (NSAIDs)—sulindac (SU), ketoprofen (KE), indomethacin (IN), piroxicam (PI), nimesulide (NI), ibuprofen (IB), and naproxen (NA). The separation was run using borate buffer (60 mmol L–1, pH 8.5) containing 13% (v/v) methanol at 20 kV, and detected at 200 nm. Several conditions were studied, including concentration and pH of borate buffer, methanol percentage, and separation voltage. In method validation, the calibration plots were linear over the range 40.0–500.0 mol L–1. In intra-day and inter-day analysis, relative standard deviations (RSD) and relative errors (RE) were all less than 5%. The limits of detection were 10 mol L–1 for SU, IN, PI, and 20 mol L–1 for KE, NI, IB, NA (S/N = 3, sampling 6 s by pressure). All recoveries were greater than 95%. This method was applied to the quality control of six NSAIDs in pharmaceuticals using NI as internal standard (IS). The assay results were within the labeled amount required by USP 25.  相似文献   

13.
Capillary zone electrophoresis has been used for the determination of gatifloxacin from its pharmaceutical preparation (tablets), using fused silica capillary. Separation was performed after hydrodynamic injection; the separation was achieved by applying 21 Kv voltage. Phosphate buffer solution (pH 9.5) was used as separation electrolyte. Detection was at 280 nm using a UV- detector. Under these experimental conditions the analysis takes 8 min. A linearity range for gatifloxacin was between 20.0 g mL–1 to 60.0 g mL–1. The method was validated and was found to be specific, precise, accurate, reproducible and robust and can be applied for the routine analysis of gatifloxacin from formulation and bulk drug.  相似文献   

14.
A method using high-performance capillary electrophoresis with electrochemical detection (CE-ED) has been developed for content comparison of phytoestrogens in both crude and parched Flos sophorae immaturus. Genistin, genistein, rutin, kaempferol and quercetin are important active constituents in this plant. The effects of several factors, such as acidity and concentration of running buffer, separation voltage, applied potential and injection time, were investigated to find the optimum conditions. Detection limits (S/N=3) ranged from 1.1 × 10–7 to 2.8 × 10–7gmL–1 for all five analytes. This method was successfully used to analyse both crude and parched Flos sophorae immaturus after a relatively simple extraction procedure, and the assay results were satisfactory.  相似文献   

15.
Summary A rapid method for the amperometric determination of copper with mandelamidoxime is described. About 0.5–8.0 mg copper(II) at a concentration of ca. 0.8–3.2 mM can be determined with accuracy (error less than ± 1%) in an ammonium chloride — ammonia buffer medium using a simple manual apparatus with a microammeter (0–50 A) of large scale for measuring the current. Direct titration of copper is possible only in the presence of cadmium while in the presence of all other commonly associated elements preliminary separation is necessary.Formerly: Research Officer, Department of Inorganic & Analytical Chemistry, Indian Association for the Cultivation of Science, Calcutta-32, India  相似文献   

16.
A novel method, capillary electrophoresis with amperometric detection, has been established for rapid and effective measurement of levodopa (L-dopa), and benserazide (BS) and its impurity (R,S)-2-amino-3-hydroxypropanohydrazide (Ro-04-1419) in co-beneldopa pharmaceutical formulations. Suitable separation and amperometric detection conditions were investigated and optimized. The optimum conditions of CZE detection were 40 mm phosphate solution at pH 5.3 as running buffer, 17 kV separation voltage, carbon-disk working electrode, 0.95 V (relative to Ag/AgCl) as detection potential, and sample injection for 8 s at 17 kV. The linear ranges were from 1.25 to 50 g mL–1 for L-dopa, 1.2 × 10–1 to 25.5 g mL–1 for BS, and 1.0 × 10–2 to 4.4 × 10–1 g mL–1 for Ro-04-1419, with correlation coefficients of 0.9994, 0.9951, and 0.9933, respectively. The detection limits for L-dopa, BS, and Ro-04-1419 were 0.38, 0.02, and 0.004 g mL–1, respectively. Average recoveries were 100.2% for L-dopa, 102.4% for BS, and 90.8% for Ro-04-1419. This method was successfully applied to co-beneldopa granules and tablets.Revised: 30 November and 22 December 2004  相似文献   

17.
This paper describes a simple and rapid procedure for determination of traces of phosphate by means of molybdenum blue chemistry. The use of a cost-effective home-made flow cell with a long path length in combination with a light emitting diode (LED) and a photodiode (PD) is demonstrated as a simple absorbance detector for flow-injection analysis. In this method, a sample is injected into the carrier stream through an injection valve and mixed online with mixed reagent (a mixture of molybdate, bismuth, and ascorbic acid in sulfuric acid). The color intensity of the resulting association complex, molybdenum blue, is measured photometrically (max 875 nm). The proposed method can be used to detect phosphate in the range 0.02–4.0 mg L–1 and the precision of the proposed procedure is less than 5% at 0.1 mg L–1 phosphorus as phosphate. The method has been successfully applied to a variety of natural water samples.  相似文献   

18.
Accumulation of selected cephalosporin antibiotics cefazolin, cefotaxime, cefuroxime and ceftriaxone on hanging mercury drop electrode was studied. The effects of supporting electrolyte composition, pH, accumulation potential and time were examined and corresponding analytical parameters were established employing linear sweep (staircase) or differential pulse voltammetric detection. Britton-Robinson buffer of pH 4.0 for ceftriaxone and acetate buffer in the pH range 3.6–5.0 for the other three compounds were found to be the best media. Calibration curves were linear from micromolar down to nanomolar range with limits of detection 2 × 10–9 moll–1, 1 × 10–9 moll–1, 5 × 10–10 moll–1 and 5 × 10–9 moll–1 for cefazolin, cefotaxime, cefuroxime and ceftriaxone respectively, applying the accumulation times of 5 to 14 min. Direct and simple determination of cefazolin as a model compound in urine was established with no other manipulation of urine sample than dilution 1 + 500 with buffer and subsequent adsorptive stripping voltammetric determination. The detection limit of the method is 7 gml–1 (1.5 × 10–5 moll–1) of cefazolin in urine, and the relative standard deviation of 9 measurements was found to be 2.8% at 23 gml–1 of cefazolin in urine. Similar values were found for other three compounds as well. These values are comparable or even better than those obtained by high performance liquid Chromatographic methods and approve the suitability of the proposed method for urine level monitoring in clinical practice and pharmacological studies.  相似文献   

19.
A high-performance liquid chromatography–inductively coupled plasma mass spectrometry (HPLC–ICP–MS) method is presented for analysis of cisplatin, monoaquacisplatin, diaquacisplatin, carboplatin, and oxaliplatin in biological and environmental samples. Chromatographic separation was achieved on pentafluorophenylpropyl-functionalized silica gel. For cisplatin, carboplatin, and oxaliplatin limits of detection of 0.09, 0.10, and 0.15 g L–1, respectively, were calculated at m/z 194, using aqueous standard solutions. (3 L injection volume). The method was utilized for model experiments studying the stability of carboplatin and oxaliplatin at different chloride concentrations simulating wastewater and surface water conditions. It was found that a high fraction of carboplatin is stable in ultrapure water and in solutions containing 1.5 mol L–1 Cl, whereas oxaliplatin degradation was increased by increasing the chloride concentration. In order to support the assessment of oxaliplatin eco-toxicology, the method was tested for speciation of patient urine. The urine sample contained more than 17 different reaction products, which demonstrates the extensive biotransformation of the compound. In a second step of the study the method was successfully evaluated for monitoring cancerostatic platinum compounds in hospital waste water.  相似文献   

20.
A simple, rapid, and accurate HPLC method is described for the determination of ritodrine hydrochloride (RTH) in both pure form and pharmaceutical formulations. A Hypersil Shendon ODS column with a mobile phase of dibasic phosphate buffer and acetonitrile (75 : 25) and isoxsuprine hydrochloride were used as an internal standard. The flow rate was 1 mL min–1 and the effluent was monitored at 270 nm pH 4.0. The calibration graph is linear in the range 2–30 g mL–1. The proposed HPLC method has been successfully employed for the determination of RTH in Yutopar tablets and injection solutions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号