共查询到20条相似文献,搜索用时 15 毫秒
1.
Hydrogen peroxide (H2O2) in exhaled breath condensate (EBC) has been proposed as a marker for oxidative stress in the airways. The aim of the present study was to evaluate the measurement of H2O2 in EBC with or without use of a nose clip, and the influence of mouth rinsing, sampling time and storage.An elevated H2O2 level was seen during nasal breathing compared to mouth breathing with nose clip (3.4 pmol/s vs. 2.1 pmol/s, p = 0.02). Breathing through the mouth, using a nose clip, was therefore practiced in all experiments. The H2O2 levels were increased when mouth rinsing was performed using an acid buffer (1.4 pmol/s vs. 1.9 pmol/s, p = 0.03). 15 min sampling time decreased the H2O2 output by almost 50% compared with 2 min sampling time (1.2 vs. 0.6 pmol/s, p = 0.03). When samples were left unattended for 15 min no change in H2O2 concentration in the EBC was seen.We found no significant differences in H2O2 levels between samples stored for 4 weeks at − 80 °C and samples analysed directly; however, a significant decrease in the levels was seen for samples stored for 4 weeks at − 20 °C.In conclusion, the method of EBC collection and storage plays an important role in reducing variability within and between individuals. 相似文献
2.
Cáp P Dryahina K Pehal F Spanel P 《Rapid communications in mass spectrometry : RCM》2008,22(18):2844-2850
Collection of exhaled breath condensate (EBC) is a relatively simple noninvasive method of breath analysis; however, no data have been reported that would relate concentration of volatile compounds in EBC to their gaseous concentrations in exhaled air. The aim of the study was to investigate which volatile compounds are present in EBC and how their concentrations relate to results of direct breath analysis. Thus, samples of EBC were collected in a standard way from several subjects and absolute levels of several common volatile breath metabolites (ammonia, acetone, ethanol, methanol, propanol, isoprene, hydrogen cyanide, formaldehyde and acetaldehyde) were then determined in their headspace using selected ion flow tube mass spectrometry (SIFT-MS). Results are compared with those from on-line breath analyses carried out immediately before collecting the EBC samples. It has been demonstrated that SIFT-MS can be used to quantify the concentrations of volatiles in EBC samples and that, for methanol, ammonia, ethanol and acetone, the EBC concentrations correlate with the direct breath levels. However, the EBC concentrations of isoprene, formaldehyde, acetaldehyde, hydrogen cyanide and propanol do not correlate with direct breath measurements. Copyright (c) 2008 John Wiley & Sons, Ltd. 相似文献
3.
K. U. Fedorchenko A. M. Ryabokon A. S. Kononikhin S. I. Mitrofanov V. V. Barmin O. V. Pikin E. H. Anaev I. V. Gachok I. A. Popov E. N. Nikolaev A. G. Chuchalin S. D. Varfolomeev 《Moscow University Chemistry Bulletin》2016,71(2):134-139
A comparative study of the exhaled-breath-condensate (EBC) proteome that was obtained for four donor groups was carried out using ion cyclotron resonance mass spectrometry with electrospray ionization. The groups included subjects with diagnosed lung cancer, chronic obstructive pulmonary disease, community-acquired pneumonia, and healthy nonsmoking control subjects. More than 300 proteins were identified, while 19 of them were found in the EBC samples of the donors who were diagnosed with lung cancer in the early stages and are potentially significant in the development of a diagnostic lung-cancer biomarker panel. It was shown that the EBC protein profiles of different donor groups can be distinguished. It may be possible to highlight a specific protein group that is typical for certain conditions/diseases of the respiratory system. Thus, the EBC analysis could be a promising non-invasive method for early diagnosis of lung cancer. 相似文献
4.
We show that exhaled breath condensate (EBC) contains glucose (≈ 0.01 mM for healthy subjects), in contrast to previous works reporting minimal glucose content in EBC. The evaluated breath condensate glucose levels correlate positively with blood glucose levels, thus offering the prospect of a non-invasive approach to the monitoring of diabetes. 相似文献
5.
Kurova V. S. Anaev E. C. Kononikhin A. S. Popov I. A. Fedorchenko K. Yu. Nikolaev E. N. Varfolomeev S. D. Chuchalin A. G. 《Russian Chemical Bulletin》2010,59(1):292-296
Analysis of samples of exhaled breath condensate (EBC) is a promising noninvasive method for the control of the status of
the human respiratory system. In the present work, the proteome of the EBC samples received from a patient with lung dystrophy
at different times before and after bilateral lung transplantation is analyzed by ion cyclotron resonance mass spectrometry.
Qualitative protein composition of EBC samples obtained during the first month correlates with the clinical data on the acceptance
of the transplanted lungs (allograft). Fifteen months after the lung surgery, the protein spectrum was similar to the normal
composition of EBC proteins. This result agrees with the medical conclusion about normal lung functioning. The results suggest
that the mass spectrometric monitoring of the protein spectra of EBC may be a tool for noninvasive pulmonological diagnostics. 相似文献
6.
Behrouz Seyfinejad Ali Meshkini Paria Habibolahi Sibel A. Ozkan Abolghasem Jouyban 《Electrophoresis》2020,41(9):666-677
Application of hollow fiber-based electromembrane extraction was studied for extraction and quantification of phenytoin from exhaled breath condensate (EBC). Phenytoin is extracted from EBC through a supported liquid membrane consisting of 1-octanol impregnated in the walls of a hollow fiber, and into an alkaline aqueous acceptor solution inside the lumen of the fiber. Under the obtained conditions of electromembrane extraction, that is, the extraction time of 15 min, stirring speed of 750 rpm, donor phase pH at 11.0, acceptor pH at 13.0, and an applied voltage of 15 V across the supported liquid membrane, an enrichment factor of 102-fold correspond to extraction percent of 25.5% was achieved. Good linearity was obtained over the concentration range of 0.001–0.10 µg/mL (r2 = 0.9992). Limits of detection and quantitation were 0.001 and 0.003 µg/mL, respectively. The proposed method was successfully applied to determine phenytoin from EBC samples of patients receiving the drug. No interfering peaks were detected that indicating excellent selectivity of the method. The intra- and interday precisions (RSDs) were less than 14%. 相似文献
7.
In this paper, a novel flow injection chemiluminescence (FI-CL) method is proposed for the determination of picomolar L(-1) levels of hydrogen peroxide (H(2)O(2)) in exhaled breath condensate (EBC). This method is based on the oxidation of a low concentration of luminol (10(-7) M) by H(2)O(2) at a low concentration level (< 10(-8) M) in an alkaline medium catalyzed by a complex, K(5)[Cu(HIO(6))(2)] (DPC), which is not interfered by other metal ions or horseradish peroxidase (HRP). Under the optimum conditions, H(2)O(2) was determined over the range of 1.0 x 10(-10) to 1.0 x 10(-8) mol L(-1) with a detection limit of (3sigma) of 4.1 x 10(-11) mol L(-1). The relative standard deviation (RSD) was 3.2% for 5 nmol L(-1) H(2)O(2) (n = 7). The proposed method offers the advantages of ultra-sensitivity, selectivity, simplicity and rapidity for H(2)O(2) determination. It was successfully applied to directly determine trace amounts of H(2)O(2) (nmol L(-1)) in human's EBC of both rheum and healthy volunteers. A statistically significant difference was found between patients with rheum (n = 11) and control subjects without rheum (n = 11). 相似文献
8.
Goldoni M Caglieri A Poli D Vettori MV Corradi M Apostoli P Mutti A 《Analytica chimica acta》2006,562(2):229-235
Chromium speciation has attracted attention because of the different toxicity of Cr(III), which is considered relatively non-toxic, and Cr(VI), which can cross cell membranes mainly as a chromate anion and has been classified as a class I human carcinogen. The aims of the present study were to measure soluble Cr(VI) levels in environmental samples, to develop a simple method of quantifying Cr(VI) in exhaled breath condensate (EBC), and to follow the kinetics of EBC Cr(VI) in chrome plating workers.Personal air samples were collected from 10 chrome platers; EBC was collected from the same workers immediately after the work shift on Tuesday and before the work shift on the following Wednesday. Environmental and EBC Cr(VI) levels were determined by means of colorimetry and electrothermal absorption atomic spectrometry, respectively.The method of detecting Cr(VI) in environmental air was based on the extraction of the Cr(VI)-diphenylcarbazide (Cr(VI)-DPC) complex in 1-butanol, whereas EBC Cr(VI) was determined using a solvent extraction of Cr(VI) as an ion pair with tetrabutylammonium ion, and subsequent direct determination of the complex (Cr(VI)-DPC) in EBC.Kinetic data showed that airborne Cr(VI) was reduced by 50% in airway lining fluid sampled at the end of exposure and that there was a further 50% reduction after about 15 h. The persistence of Cr(VI) in EBC supports the use of EBC in assessing target tissue levels of Cr(VI). 相似文献
9.
Analytical instruments that can measure small amounts of chemicals in complicated biological samples are often useful as diagnostic tools. However, it can be challenging to optimize these sensors using actual clinical samples, given the heterogeneous background and composition of the test materials. Here we use gas chromatography-differential mobility spectrometry (GC/DMS) to analyze the chemical content of human exhaled breath condensate (EBC). Ultimately, this system can be used for non-invasive disease diagnostics. Many parameters can be adjusted within this instrument system, and we implemented a factorial design-of-experiments to systematically test several combinations of parameter settings while concurrently analyzing effects and interactions.We examined four parameters that affect sensitivity and detection for our instrument, requiring a 24 factorial design. We optimized sensor function using EBC samples spiked with acetone, a known clinical biomarker in breath. Two outputs were recorded for each experiment combination: number of chemicals detected, and the amplitude of acetone signal. Our goal is to find the best parameter combination that yields the highest acetone peak while also preserving the largest number of other chemical peaks in the spectra. By optimizing the system, we can conduct further clinical experiments with our sensor more efficiently and accurately. 相似文献
10.
Esther CR Jasin HM Collins LB Swenberg JA Boysen G 《Rapid communications in mass spectrometry : RCM》2008,22(5):701-705
Exhaled breath condensate (EBC) collection is a simple and non-invasive method to sample airway secretions, but analysis is limited by extensive and variable dilution of airway secretions within the condensate. To overcome this limitation, we developed a sensitive and specific liquid chromatography/tandem mass spectrometry (LC/MS/MS) method to simultaneously detect adenyl purines as biomarkers of inflammation and urea as a dilution marker in EBC. Separation prior to mass spectrometry was achieved using a C18 column with methanol and formic acid as the mobile phase, and characteristic precursor to product ion transitions of m/z 268 to 136 (for adenosine), m/z 348 to 136 (for AMP), and m/z 61 to 44 (for urea) were monitored for quantification. To correct for matrix effects, isotopically labeled adenosine, AMP, and urea were used as internal standards. Using these methods, we detected urea and the adenyl purines adenosine and AMP in EBC from seven subjects with cystic fibrosis (CF) and seven healthy controls and found that the AMP/urea ratio was elevated in the CF samples. These results demonstrate that mass spectrometry can be used successfully in EBC analysis to simultaneously detect a biomarker for airway inflammation and control for variable dilution. 相似文献
11.
Montuschi P Martello S Felli M Mondino C Chiarotti M 《Rapid communications in mass spectrometry : RCM》2004,18(22):2723-2729
The objective of this study is the measurement of leukotriene B7 (LTB4), a potent inflammatory mediator, in exhaled breath condensate by using liquid chromatography/mass spectrometry (LC/MS and LC/MS/MS). Condensation of exhaled breath is a non-invasive method to collect airway secretions. Deuterated (d4)-LTB4 was used as internal standard. The MS and MS/MS behavior of LTB4 and LTB4-d4 was studied by electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) in both positive and negative ion polarity mode. Preliminary results show that monitoring negative ions in ESI mode has the best sensitivity for both LTB4 and LTB4-d4. Therefore, negative ESI was chosen, and the [M-H]- ions at m/z 335 and 339 were selected for quantification. The lower limit of quantification for LTB4, expressed as the lowest point of the calibration curve, was 100 pg/mL. Using this technique, we measured LTB4 in exhaled breath condensate in two healthy subjects, four asthmatic patients on anti-inflammatory treatment, and four asthmatic patients who were not on anti-inflammatory drugs. Exhaled LTB4 concentrations were detected only in asthmatic patients who were not on anti-inflammatory therapy. This method is potentially useful for non-invasive assessment of airway inflammation, but the sensitivity of the technique needs to be improved. 相似文献
12.
13.
Gonzalez-Reche LM Kucharczyk A Musiol AK Kraus T 《Rapid communications in mass spectrometry : RCM》2006,20(18):2747-2752
In order to identify new biomarkers for pulmonary diseases in exhaled breath condensate (EBC) it was the aim of this study to develop an analytical method for the identification and quantification of N epsilon-(carboxymethyl)lysine (CML) in EBC. As detection by liquid chromatography with positive electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) offers the advantage of structurally related detection with the necessary specificity required for the identification of a substance, it was the method chosen for the determination of the non-volatile compound. Specific mass transitions and comparison of retention times with standards under given conditions were used for the unequivocal identification of CML in EBC of healthy subjects. Synthesis of isotopically labelled CML was performed and used as an internal standard for an accurate determination. It was possible to identify the advanced glycation end-product CML in 8 out of 10 healthy subjects. The concentration range determined in the quantifiable examined samples ranged between 35 and 110 pg/mL. EBC samples from 11 patients with different diseases such as diabetes and chronic obstructive pulmonary disease were also measured. In one patient with pneumonia a concentration of 1509 pg CML/mL EBC could be detected. This is the first time that CML has been identified and determined in EBC. The developed LC/ESI-MS/MS method could be used to address the utility of CML as a biomarker in pulmonary diseases. 相似文献
14.
Changsong Wang Chaofu Ke Xiaoyang Wang Chunjie Chi Lei Guo Suqi Luo Zhigang Guo Guowang Xu Fengmin Zhang Enyou Li 《Analytical and bioanalytical chemistry》2014,406(19):4757-4763
There has been growing interest in exhaled breath analysis for cancer screening and disease monitoring; however, limited breath biomarker information exists regarding colorectal cancer (CRC). The objective of this study was to screen for breath biomarkers of CRC. Exhaled breath was collected from 20 CRC patients and 20 healthy controls; subsequently, solid-phase microextraction–gas chromatography/mass spectrometry (SPME-GC/MS) was used to assess the exhaled volatile organic compounds (VOCs) of the study participants. The statistical methods of principal component analysis (PCA) and partial least squares discriminant analysis (PLS-DA) were performed to process the final data. The VOCs in the exhalations of CRC patients exhibited significant differences from the VOCs in the exhalations of healthy controls; in particular, relative to the latter exhalations, the former exhalations contain significantly higher levels of cyclohexanone, 2,2-dimethyldecane, dodecane, 4-ethyl-1-octyn-3-ol, ethylaniline, cyclooctylmethanol, trans-2-dodecen-1-ol, and 3-hydroxy-2,4,4-trimethylpentyl 2-methylpropanoate but significantly lower levels of 6-t-butyl-2,2,9,9-tetramethyl-3,5-decadien-7-yne (P?<?0.05). Analyses of breath VOCs provide a related model of CRC exhalation that could represent an effective and convenient screening method for this disease. Figure
Partial least-squares discriminant analysis scores plot (with the three components of R2X=0.583, R2Y=0.806, and Q2=0.565), which reveals that a considerable separation was achieved between colorectal cancer breath samples and normal controls 相似文献
15.
Andreoli R Manini P Corradi M Mutti A Niessen WM 《Rapid communications in mass spectrometry : RCM》2003,17(7):637-645
A method for the simultaneous determination of several classes of aldehydes in exhaled breath condensate (EBC) was developed using liquid chromatography/atmospheric pressure chemical ionization tandem mass spectrometry (LC/APCI-MS/MS). EBC is a biological matrix obtained by a relatively new, simple and noninvasive technique and provides an indirect assessment of pulmonary status. The measurement of aldehydes in EBC represents a biomarker of the effect of oxidative stress caused by smoke, disease, or strong oxidants like ozone. Malondialdehyde (MDA), acrolein, alpha,beta-unsaturated hydroxylated aldehydes [namely 4-hydroxyhexenal (4-HHE) and 4-hydroxynonenal (4-HNE)], and saturated aldehydes (n-hexanal, n-heptanal and n-nonanal) were measured in EBC after derivatization with 2,4-dinitrophenylhydrazine (DNPH). Atmospheric pressure chemical ionization of the analytes was obtained in positive-ion mode for MDA, and in negative-ion mode for acrolein, 4-HHE, 4-HNE, and saturated aldehydes. DNPH derivatives were separated on a C18 column using variable proportions of 20 mM aqueous acetic acid and methanol. Linearity was established over 4-5 orders of magnitude and limits of detection were in the 0.3-1.0 nM range. Intra-day and inter-day precision were in the 1.3-9.9% range for all the compounds. MDA, acrolein and n-alkanals were detectable in all EBC samples, whereas the highly reactive 4-HHE and 4-HNE were found in only a few samples. Statistically significant higher concentrations of MDA, acrolein and n-hexanal were found in EBC from smokers. 相似文献
16.
In this paper, polypyrrole/graphene (PPy/G) composite coating was prepared by a facile electrochemical polymerization strategy on the inner surface of a stainless steel (SS) tube. Based on the coating tube, a novel online in-tube solid-phase microextraction -high performance liquid chromatography (IT-SPME-HPLC) was developed and applied for the extraction of aldehydes in the human exhaled breath condensates (EBC). The hybrid PPy/G nanocomposite exhibits remarkable chemical and mechanical stability, high selectivity, and satisfactory extraction performance toward aldehyde compounds. Moreover, the proposed online IT-SPME-HPLC method possesses numerous superiorities, such as time and cost saving, process simplicity, high precision and sensitivity. Some parameters related to extraction efficiency were optimized systematically. Under the optimal conditions, the recoveries of the aldehyde compounds at three spiked concentration levels varied in the range of 85%–117%. Good linearity was obtained with excellent correlation coefficients (R2) being larger than 0.994. The relative standard deviations (n = 5) of the method ranged from 1.8% to 11.3% and the limits of detection were between 2.3 and 3.3 nmol L−1. The successful application of the proposed method in human EBC indicated that it is a promising approach for the determination of trace aldehyde metabolites in complex EBC samples. 相似文献
17.
T. Rabis U. Sommerwerck O. Anhenn K. Darwiche L. Freitag H. Teschler B. Bödeker S. Maddula J. I. Baumbach 《International Journal for Ion Mobility Spectrometry》2011,14(4):187-195
Diseases of the lung, e. g. chronic obstructive pulmonary disease (COPD), interstitial lung diseases, bronchiectasis or cystic
fibrosis, often lead to recurrent severe respiratory infections that cause exacerbations of the underlying disease. These
acute or chronic inflammatory processes can result in a progressive destruction of the lung and in an ongoing decline in lung
function. Therefore longer inpatient stays for intravenous antibiotic treatment are necessary and the quality of life in these
patients is severely limited. A rapid detection of infectious agents in human lungs is often crucial, because the choice of
the appropriate therapeutic regime depends at first on the identification of the infecting species. Standard methods for detection
and identification are either time consuming, of low sensitivity or expensive. It is known that bacteria, and also mitosporic
fungi, produce volatile organic compounds (VOCs) that can be detected in exhaled breath by ion mobility spectrometry (IMS),
were a distinct detection of a specific VOC is related to a “peak”. We investigated, whether the detection and characterisation
of VOCs by Multi-capillary column coupled to IMS in exhaled breath of patients whose airways are either infected or colonized
by Pseudomonas aeruginosa compared to healthy non-smoker controls is capable of identifying those infectious agents. To realize a non invasive identification
of pathogens, the exhaled breath of 53 persons (24 patients suffering chronic or infectious on Pseudomonas and 29 healthy
controls) was investigated using an ion mobility spectrometer type BioScout. In total 224 different signals were found. Actually,
21 different signals are able to differentiate the two groups, Control and Pseudomonas, with rank sum values less than 0.2.
For all 224 signals Box-and-Wisker plots were realized. The peaks with the lowest rank sum values F (0,107) and PS0 (0,112)
show rather good separation of both groups. Our preliminary results demonstrate that distinct patterns of a small number of
IMS-peaks are sufficient for the identification of these infectious agents. Therefore MCC-IMS seems to be a promising method
for the non-invasive identification of patients which are colonized or infected with bacteria such as Pseudomonas aeruginosa. 相似文献
18.
In recent years, electrical sensors toward breath volatolomics have attracted increasing interest owing to their wide feasibility in noninvasive disease diagnostics. In this article, the working principles of active nanomaterials (e.g. metal oxides, polymers, and nanocarbon) toward volatile organic compounds are presented, with a special focus on the influence of surface chemistry and structural feature of these nanomaterials on the sensing performance. The latest and representative achievements on the direct analysis of three typical exhaled volatile organic compounds, including acetone, ammonia, and hydrogen sulfide, that are recognized as important disease biomarkers, are highlighted, indicating the capability of the electrical sensors in enabling noninvasive diagnosis and real-time monitoring. The opportunities and challenges in this field are provided in the end, with an emphasis on the background interference and data recognition which are key factors in developing prospective electrical sensors toward volatolomics analysis. 相似文献
19.
《Biomedical chromatography : BMC》2018,32(4)
Cigarette smoking harms nearly every organ of the body and causes many diseases. The analysis of exhaled breath for exogenous and endogenous volatile organic compounds (VOCs) can provide fundamental information on active smoking and insight into the health damage that smoke is creating. Various exhaled VOCs have been reported as typical of smoking habit and recent tobacco consumption, but to date, no eligible biomarkers have been identified. Aiming to identify such potential biomarkers, in this pilot study we analyzed the chemical patterns of exhaled breath from 26 volunteers divided into groups of nonsmokers and subgroups of smokers sampled at different periods of withdrawal from smoking. Solid‐phase microextraction technique and gas chromatography/mass spectrometry methods were applied. Many breath VOCs were identified and quantified in very low concentrations (ppbv range), but only a few (toluene, pyridine, pyrrole, benzene, 2‐butanone, 2‐pentanone and 1‐methyldecyclamine) were found to be statistically significant variables by Mann–Whitney test. In our analysis, we did not consider the predictive power of individual VOCs, as well as the criterion of uniqueness for biomarkers suggests, but we used the patterns of the only statistically significant compounds. Probit prediction model based on statistical relevant VOCs‐patterns showed that assessment of smoking status is heavily time dependent. In a two‐class classifier model, it is possible to predict with high specificity and sensitivity if a subject is a smoker who respected 1 hour of abstinence from smoking (short‐term exposure to tobacco) or a smoker (labelled "blank smoker") after a night out of smoking (long‐term exposure to tobacco). On the other side, in our study "blank smokers" are more like non‐smokers so that the two classes cannot be well distinguished and the corresponding prediction results showed a good sensitivity but low selectivity. 相似文献