首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
High-resolution continuum source molecular absorption of the calcium mono-fluoride molecule CaF in a graphite furnace has been used to determine fluorine in tea after acid digestion, alkaline solubilization and preparation of a conventional aqueous infusion. The strongest absorption ‘line’ of the CaF molecule is at 606.440 nm, which is part of the rotational fine structure of the X2Σ+ − A2Π electronic transition; it has a bond dissociation energy of 529 kJ mol−1, which is comparable with other molecules used for fluorine determination. One advantage of using Ca as the molecule-forming reagent is that spectral interferences are extremely unlikely in the spectral range of its strongest absorption. Another advantage is that Ca acts both as molecule forming reagent and chemical modifier, so that no other reagent has to be added, making the method very simple. The only disadvantage is that Ca has a somewhat negative influence on the graphite tube lifetime. The limit of detection was found to be 0.16 mg L−1 F, corresponding to 1.6 ng F absolute, and the calibration curve was linear in the range between 0.5 and 25 mg L−1 with a correlation coefficient of R = 0.9994. The results obtained for a certified tea reference material were in agreement with the certified value on a 95% confidence level. There was also no difference between the results obtained after an acid digestion and an alkaline solubilization for 10 tea samples, based on a paired t-test. The values found in the 10 samples ranged between 42 μg g−1 and 87 μg g−1 F; the tea infusions contained between 21 μg g−1 and 56 μg g−1 F, with an extraction rate between 48% and 74%.  相似文献   

2.
Ruthenium (Ru), thermally deposited on a integrated platform graphite furnace, was investigated as a permanent modifier for the determination of Aluminum (Al) in blood serum and urine by electrothermal atomic absorption spectrometry (ETAAS). The platform was treated with 500 μg of Ru as previously described. The pyrolysis and atomization temperatures for each material were of 1300 and 2300 °C, for serum sample and of 1000 and 2400 °C, for urine. The characteristic mass were of 31 and 33 pg for Al in serum sample and urine, respectively (recommended of 31 pg for Al in nitric acid 0.2% (v/v)). For this reason, the calibration was made with aqueous solutions for both the samples. Calibration curves presented r of 0.99145 and 0.99991 for serum and urine, respectively. With the optimized temperatures, being analyzed eight spiked blood serum samples, the recovery was between 95.90 and 113.50%. Two certified urines samples were analyzed with good agreement between experimental and reference values. In both the samples the R.S.D. were <5% (n=3). The detection limit (k=3, n=10) was of 0.40 μg of Al per liter for both the samples. The absorption pulses obtained were symmetrical, with very low background and without interferences. The life time of the tube-platform was higher than 600 cycles of atomizations for both the urine and serum samples.  相似文献   

3.
For the first time, high-resolution molecular absorption spectrometry with a high-intensity xenon lamp as radiation source has been applied for the determination of sulphur in crude oil and petroleum products. The samples were analysed as xylene solutions using vaporisation in acetylene-air flame or in an electrothermally heated graphite furnace. The sensitive rotational lines of the CS molecule, belonging to the ?ν = 0 vibrational sequence within the electronic transition X1+ → A1П, were applied. For graphite furnace molecular absorption spectrometry, the Pd + Mg organic modifier was selected. Strong interactions with Pd atoms enable easier decomposition of sulphur-containing compounds, likely through the temporal formation of PdxSy molecules. At the 258.056 nm line, with the wavelength range covering central pixel ± 5 pixels and with application of interactive background correction, the detection limit was 14 ng in graphite furnace molecular absorption spectrometry and 18 mg kg−1 in flame molecular absorption spectrometry. Meanwhile, application of 2-points background correction found a characteristic mass of 12 ng in graphite furnace molecular absorption spectrometry and a characteristic concentration of 104 mg kg−1 in flame molecular absorption spectrometry.The range of application of the proposed methods turned out to be significantly limited by the properties of the sulphur compounds of interest. In the case of volatile sulphur compounds, which can be present in light petroleum products, severe difficulties were encountered. On the contrary, heavy oils and residues from distillation as well as crude oil could be analysed using both flame and graphite furnace vaporisation. The good accuracy of the proposed methods for these samples was confirmed by their mutual consistency and the results from analysis of reference samples (certified reference materials and home reference materials with sulphur content determined by X-ray fluorescence spectrometry).  相似文献   

4.
In thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) a nickel atomization tube is placed in the acetylene/air flame on a holder built onto a standard AAS burner head. The liquid to be analyzed is transported by a low or high-pressure pump through a very hot, simple, inexpensive ceramic capillary tip acting as a flame-heated thermospray into the flame furnace. This results in complete sample introduction and increases the residence time of the sample in the absorption volume. This leads for 17 elements to a 3-110-fold improvement in the power of detection compared to conventional flame AAS. The absolute detection limits (3s values, N=25) lie between 0.2 μg l−1 (Zn) and 310 μg l−1 (Se) according to the element. The R.S.D. (N=15) is 1.4-5.5% according to the element and applied concentration. TS-FF-AAS can easily be incorporated on any standard flame AAS instrument and can be automated with a standard autosampler.  相似文献   

5.
An electrolytic hydride generation system for determination of another hydride forming element, cadmium, by catholyte variation electrochemical hydride generation (EcHG) atomic absorption spectrometry is described. A laboratory-made electrolytic cell with lead-tin alloy as cathode material is designed as electrolytic generator of molecular hydride. The influences of several parameters on the analytical signal have been evaluated using a Plackett-Burman experimental design. The significant parameters such as cathode surface area, electrolytic current, carrier gas flow rate and catholyte concentration have been optimized using univariate method. The analytical figures of merit of procedure developed were determined. The calibration curve was linear up to 20 ng ml−1of cadmium. The concentration detection limit (3σ, n = 8) of 0.2 ng ml−1 and repeatability (relative standard deviation, n = 7) of 3.1% were achieved at 10.0 ng ml−1. It was shown that interferences from major constituents at high concentrations were significant. The accuracy of method was verified using a real sample (spiked tap water) by standard addition calibration technique. Recovery of 104% was achieved for Cd in the spiked tap water sample.  相似文献   

6.
A high-performance liquid chromatographic method for the determination in human plasma of the recent noradrenergic and specific serotonergic antidepressant (NaSSA) mirtazapine and its two main metabolites, N-desmethylmirtazapine and 8-hydroxymirtazapine, has been developed. Fluorescence detection was used, exciting at λ = 290 nm and monitoring emission at λ = 370 nm. Separation was obtained by using a reversed-phase column (C8, 250 mm × 4.6 mm I.D., 5 μm) and a mobile phase composed of 75% aqueous phosphate buffer containing triethylamine at pH 3.0 and 25% acetonitrile. Melatonin was used as the internal standard. A careful pre-treatment of plasma samples was developed, using solid-phase extraction with phenyl cartridges (100 mg, 1 mL). The calibration curves were linear over a working range of 5-150 ng mL−1 for mirtazapine and of 2.5-75.0 ng mL−1 for N-desmethylmirtazapine and 8-hydroxymirtazapine. The limit of quantitation (LOQ) was 2.5 ng mL−1 and the limit of detection (LOD) was 1.25 ng mL−1 for all analytes. The method was applied with success to plasma samples from depressed patients undergoing treatment with mirtazapine. Precision data, as well as accuracy results, were satisfactory and no interference from other drugs was found. Hence the method is suitable for therapeutic drug monitoring of mirtazapine and its metabolites in depressed patients’ plasma.  相似文献   

7.
A novel on-line preconcentration and determination system based on a fiber-packed column was developed for speciation analysis of Cr in drinking water samples prior to its determination by flame atomic absorption spectrometry (FAAS). All variables involved in the development of the preconcentration method including, pH, eluent type, sample and eluent flow rates, interfering effects, etc., were studied in order to achieve the best analytical performance. A preconcentration factor of 32 was obtained for Cr(VI) and Cr(III). The levels of Cr(III) species were calculated by difference of total Cr and Cr(VI) levels. Total Cr was determined after oxidation of Cr(III) to Cr(VI) with hydrogen peroxide. The calibration graph was linear with a correlation coefficient of 0.999 at levels near the detection limit and up to at least 50 μg L−1. The relative standard deviation (R.S.D.) was 4.3% (C = 5 μg L−1 Cr(VI), n = 10, sample volume = 25 mL). The limit of detection (LOD) for both Cr(III) and Cr(VI) species was 0.3 μg L−1. Verification of the accuracy was carried out by the analysis of a standard reference material (NIST SRM 1643e “Trace elements in natural water”). The method was successfully applied to the determination of Cr(III) and Cr(VI) species in drinking water samples.  相似文献   

8.
A kinetic spectrophotometric procedure was developed for determination of submicromolar orthophosphate based on the reaction in which orthophosphate serves as a catalyst in the reduction of molybdenum, and the initial rate of molybdenum-blue formation (λmax = 780 nm) is proportional to the concentration of orthophosphate in the samples. The detection limit (3 × standard deviation of blank, n = 8) was 6 nM and the linear calibration ranged from 10 to 100 nM (r2 = 0.997). The precisions of this method were 3.3% at 10 nM and 5.4% at 50 nM (n = 8), respectively. Similar to other molybdate based methods, silica and arsenate in the samples can interfere with phosphate determination. The responses of silicate and arsenate were about 25% and 7% of that of orthophosphate, respectively, and their interferences were enhanced in the presence of phosphate in the samples due to the synergistic effect of phosphate with arsenate or silicate on the molybdate reagent.  相似文献   

9.
The analytical performance of coupled hydride generation — integrated atom trap (HG-IAT) atomizer flame atomic absorption spectrometry (FAAS) system was evaluated for determination of Te in reference material (GBW 07302 Stream Sediment), coal fly ash and garlic. Tellurium, using formation of H2Te vapors, is atomized in air–acetylene flame-heated IAT. A new design HG-IAT-FAAS hyphenated technique that would exceed the operational capabilities of existing arrangements (a water-cooled single silica tube, double-slotted quartz tube or an “integrated trap”) was investigated. An improvement in detection limit was achieved compared with using either of the above atom trapping techniques separately. The concentration detection limit, defined as 3 times the blank standard deviation (3σ), was 0.9 ng mL− 1 for Te. For a 2 min in situ pre-concentration time (sample volume of 2 mL), sensitivity enhancement compared to flame AAS, was 222 fold, using the hydride generation — atom trapping technique. The sensitivity can be further improved by increasing the collection time. The precision, expressed as RSD, was 7.0% (n = 6) for Te. The designs studied include slotted tube, single silica tube and integrated atom trap-cooled atom traps. The accuracy of the method was verified using a certified reference material (GBW 07302 Stream Sediment) by aqueous standard calibration curves. The measured Te contents of the reference material was in agreement with the information value. The method was successfully applied to the determination of tellurium in coal fly ash and garlic.  相似文献   

10.
The present work reports the development of a methodology for the direct determination of vanadium in high saline waters derived from offshore petroleum exploration employing electrothermal atomic absorption spectrometry. Such waters, usually called produced waters, present complex composition containing various organic and inorganic substances. In order to attain best conditions (highest sensitivity besides lowest background) for the methodology, studies about the effects of several variables (evaluation of pyrolysis and atomization temperatures, type of chemical modifier, concentration of modifier and pyrolysis time) and the convenient calibration strategy were performed. Best conditions were reached with the addition of 10 μg of NH4H2PO4 as chemical modifier employing pyrolysis (during 10 s) and atomization temperatures of 1500 and 2700 °C, respectively. Obtained results indicated that, in this kind of sample, vanadium can be determined by standard addition method or employing an external calibration approach with standard solutions prepared in 0.8 mol l−1 NaCl medium. In order to evaluate possible matrix interferences, a recovery test was performed with five spiked samples of produced waters. The limit of detection, limit of quantification and relative standard deviation in 0.8 mol l−1 NaCl medium were also calculated and the derived values were 1.9 μg l−1, 6.3 μg l−1 and 5.6% (at 10 μg l−1 level), respectively.  相似文献   

11.
A simple, precise and accurate method for the simultaneous determination of four UV filters and five polycyclic musks (PCMs) in aqueous samples was developed by solid-phase microextraction coupled with gas chromatography–mass spectrometry (SPME-GC–MS). The operating conditions affecting the performance of SPME-GC–MS, including fiber thickness, desorption time, pH, salinity, extraction time and temperature have been carefully studied. Under optimum conditions (30 μm PDMS fiber, 7 min desorption time, pH 7, 10% NaCl, 90 min extraction time at 24 °C), the correlation coefficients (r2) of the calibration curves of target compounds ranged from 0.9993 to 0.9999. The limit of detection (LOD) and limit of quantification (LOQ) ranged from 0.2 to 9.6 ng L−1 and 0.7 to 32.0 ng L−1, respectively. The developed procedure was applied to the determinations of four UV filters and five PCMs in river water samples and internal standard was used for calibration to compensate the matrix effect. Good relative recoveries were obtained for spiked river water at low, medium and high levels. The proposed SPME method was compared with traditional SPE procedure and the results found in river water using both methods were in the same order of magnitude and both are quite agreeable.  相似文献   

12.
Bismuth was evaluated as internal standard for Pb determination by line source flame atomic absorption spectrometry (LS FAAS), high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS) and line source graphite furnace atomic absorption spectrometry (LS GFAAS). Analysis of samples containing different matrices indicated close relationship between Pb and Bi absorbances. Correlation coefficients of calibration curves built up by plotting APb/ABiversus Pb concentration were higher than 0.9953 (FAAS) and higher than 0.9993 (GFAAS). Recoveries of Pb improved from 52–118% (without IS) to 97–109% (IS, LS FAAS); 74–231% (without IS) to 96–109% (IS, HR-CS FAAS); and 36–125% (without IS) to 96–110% (IS, LS GFAAS). The relative standard deviations (n = 12) were reduced from 0.6–9.2% (without IS) to 0.3–4.3% (IS, LS FAAS); 0.7–7.7% (without IS) to 0.1–4.0% (IS, HR-CS FAAS); and 2.1–13% (without IS) to 0.4–5.9% (IS, LS GFAAS).  相似文献   

13.
Pourreza N  Mousavi HZ 《Talanta》2004,64(1):264-267
A sensitive and selective preconcentration method for the determination of trace amounts of iron by atomic absorption spectrometry has been developed. Iron forms a complex with methylthymol blue at pH=3. This complex is retained by naphthalene tetraoctylammonium bromide adsorbent in a column with a height of about 2 cm. The adsorbed metal complex is then eluted from the column with nitric acid and its iron content is determined by flame atomic absorption spectrometry (FAAS). The effect of different variables such as pH, reagent concentration, flow rate and interfering ions on the recovery of the analyte was investigated. The calibration graph was linear in the range 25-350 ng ml−1 of iron in the initial solution with r=0.9994. The limit of detection based on 3Sb criterion was 12 ng ml−1 and the relative standard deviation for eight replicate measurements of 150 and 300 ng ml−1 of iron was 3.1 and 1.8%, respectively. This procedure was successfully applied to the determination of iron in tap and sewage water samples.  相似文献   

14.
A method has been developed for identification and quantification of the acaricide amitraz and its transformation products, 2,4-dimethylaniline (DMA), 2,4-dimethylformamidine (DMF) and N-2,4-dimethylphenyl-N-methylformamidine (DMPF) in pears. The analytes were extracted using ethyl acetate and anhydrous sodium sulphate. Analysis was performed by liquid chromatography–electrospray tandem mass spectrometry (LC–ESI-MS/MS) in the positive ion mode using a triple quadrupole (QqQ) instrument. Two precursor-product ion transitions were monitored for each compound in the selected reaction monitoring (SRM) mode. The method was validated with pears taken from the orchard before the amitraz treatment and spiked at the limit of quantification (LOQ), 10 times the LOQ and the maximum residue limit (MRL). Recoveries were between 70 and 106% and relative standard deviations were below 19% (n = 5 at each spiked level). Excellent sensitivity resulted in limits of detection (LODs) for all the compounds below 10 μg kg−1. Quantification was carried out using matrix-matched standards calibration, response was a linear function of the concentration from the LOQs to, at least, three orders of magnitude. Recoveries and standard deviations were comparable to those obtained after hydrolysis of amitraz and its metabolites to DMA. Occurrence of amitraz and its metabolites in field-treated pears showed that, seven days after the treatment, DMPF and DMF are the main degradation products. This work reports for the first time the use of a conventional pesticide multiresidue method and LC–ESI-MS/MS for determining amitraz and its metabolites in pears.  相似文献   

15.
Pablo Campo  Yunzhou Chai 《Talanta》2010,80(3):1110-2388
The detection and quantitation of four ethanolamines, tris(2-hydroxyethyl)amine (triethanolamine, TEA), N,N-bis(2-hydroxyethyl)methylamine (methyldiethanolamine, MDEA), N-(2-aminoethyl)ethanolamine (AEA), and N,N-diethylethanolamine (DEA), were achieved in wastewaters from two aerobic activated sludge bioreactors located in an industrial wastewater treatment plant. The streams had salt concentrations of approximately 3% and 7% by weight in Reactor 1 and Reactor 2, respectively. The use of liquid chromatography-electrospray ionization-tandem mass spectrometry avoided the need for some sample preparation steps such as extraction, concentration, and derivatization. Ion suppression in the electrospray, attributable to the presence of sodium clusters, was attenuated by a 10-fold dilution of the wastewaters with acetonitrile. A matrix-matched calibration model averted other potential interferences. For the compounds analyzed in selected reaction monitoring mode (TEA, MDEA, and DEA), the calibration curves presented linearity in a range of 10-1000 μg/L with corresponding detection limits ranging from 2 to 11 μg/L, depending upon the specific analyte and aqueous matrix. AEA was calibrated in selected ion monitoring mode (100-1000 μg/L), with corresponding detection limits in the two wastewaters of 74.6 and 85.3 μg/L, respectively. Overall good precision (<10%) and accuracy (97-110%) were achieved for both matrices, which fell within-laboratory reproducibility. Finally, the amines were introduced into six mixed liquor samples from both reactors and quantified following the reported protocol. Again, recoveries were close to 100% with a relative standard deviation of less than 10% in all cases.  相似文献   

16.
A sensitive and simple solid-phase preconcentration procedure for enrichment of cadmium prior to analysis by flame atomic absorption spectrometry (FAAS) is described. The method is based on the adsorption of cadmium as CdI42− on naphthalene-methyltrioctylammonium chloride adsorbent, elution by nitric acid and subsequent determination by FAAS. The effect of pH, iodide concentration, sample flow rate, volume of the sample and diverse ions on the recovery of the analyte was investigated and optimum conditions were established. A preconcentration factor of 40 was achieved using the optimum conditions. The calibration graph was linear in the range 1-100 ng ml−1 cadmium in the initial solution. The detection limit based on the 3Sb criterion was 0.6 ng ml−1 and the relative standard deviations (RSD) were 3.9 and 1.05% for 5 and 40 ng ml−1, respectively (n=8). The method was successfully applied to the determination of cadmium added to river, tap and Persian Gulf water samples.  相似文献   

17.
This work describes an on-line molecularly imprinted solid-phase extraction (MISPE) method for spectrophotometric determination of nicotine in urine samples of smokers. This method is based on manganese (VII) to manganese (VI) reduction in an alkaline medium, promoted by nicotine. Two wash solutions (1:4 (v/v) acetonitrile:sodium hydroxide - pH 11.4, and nitric acid - pH 2.5) were employed to circumvent interferences. Aqueous solutions containing nicotine plus different possible concomitants (cotinine, anabasine, norcotinine and caffeine) were tested individually. The analytical calibration curve was prepared in urine samples collected from non-smokers and spiked with nicotine standard from 1.1 to 60 μmol L−1 (r2 > 0.998). The limit of quantification and the analytical frequency were 1.1 μmol L−1 and 11 h−1, respectively. The precision, evaluated using 3, 10 and 30 μmol L−1 nicotine in urine, was 10, 10 and 4% (intra-day precision) and 12, 13 and 5% (inter-day precision), respectively. Accuracy was checked through high performance liquid chromatography and the results did not present significant differences at the 95% confidence level according to the Student's t-test.  相似文献   

18.
A rapid method for analyzing brominated flame retardants (BFRs) was developed using direct exposure probe/mass spectrometry (DEP/MS). The BFRs used in this study included 1,2-bis(pentabromophenyl)ethane (EBP), tetrabromobisphenol A (TBBPA), and hexabromocyclododecane (HBCD), which are included in the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS).Quantitative analysis was conducted using octabromodiphenyl ether (octa-BDE), nonabromodiphenyl ether (nona-BDE), and decabromodiphenyl ether (deca-BDE). The samples were extracted by ultrasonication, following which the diluted sample solutions were analyzed by DEP/MS. Finally, the characteristic ions in the mass spectra of BFRs were identified.The limit of detection (LOD) and limit of quantification (LOQ) for deca-BDE were 0.163 and 0.495 mg/kg, respectively. The calibration curve showed a linearity (R2 = 0.9984) within 0.5-16 μg/mL. The relative standard deviation ranged from 2.78% to 6.76%. The octa-BDE and nona-BDE samples showed similar results. Finally, the certified reference material (CRM, NMIJ CRM 8108-a, Japan) for the deca-BDE analysis was used, and the recovery was 96.4%.  相似文献   

19.
A method for the simultaneous preconcentration and determination of Hg(II) and MeHg(I) at the ng ml−1 level has been developed. This method is based on solid phase extraction using a newly synthesized chelating resin containing nitrogen and sulphur donor sites of the 1,2-bis(o-aminophenylthio)ethane moiety that is very selective for mercury. The characterization of the resin has been carried out by elemental analyses, infrared spectral data, thermogravimetric analysis and metal ion capacities. The resin is highly selective for Hg(II) and MeHg(I) with an exchange capacity of 0.38 and 0.30 mmol g−1, respectively. Various parameters like pH, column flow rate, desorbing agents are optimized. Cold vapour atomic absorption spectrometry (CVAAS) was used to measure the concentration of both species of mercury. The calibration graph was linear upto 10 ng ml−1 with a 3σ detection limit of 0.09 ng ml−1. The recovery of Hg(II) and MeHg(I) was found to be 98.9±2.0 and 98.0±1.1%, respectively. The method has been used for routine determination of trace levels of mercury species in natural waters to comply with more stringent regulations.  相似文献   

20.
In this work, a fully automated flow system exploiting the advantages of the association of multi-pumping, multicommutation, binary sampling and merging zones, to accomplish the sequential determination of copper in serum and urine by flame atomic absorption spectrometry, is described. The developed flow system allowed multiple tasks, such as serum samples preparation (samples and standard solutions viscosity adjustment), serum copper (SCu) measurement, urine copper (UCu) pre-concentration and its subsequent elution and measurement, to be carried out sequentially. The implemented flow manifold presented a modular configuration consisting on two quasi-independent modules, each one accountable for a specific sample manipulation and whose combined operation under computer control enabled the determination of copper in a wide concentrations range.Once optimised and with a sample consumption of about 0.250 mL of serum and 7 mL of urine, the developed flow system allowed linear calibration plots up to 5 mg L−1 with a detection limit of 0.035 mg L−1 for SCu and linear calibration plots up to 300 μg L−1 with a detection limit of 0.67 μg L−1 for UCu. The sampling rate varied according to the module employed and was about 360 determinations h−1 (SCu module), 12 determinations h−1 (UCu module) or 24 determinations h−1 (12 urine and 12 serum samples; UCu and SCu modules simultaneously). Repeatability studies (R.S.D.%, n = 10) showed good precision for UCu at concentrations of 25 μg L−1 (2.54%), 50 μg L−1 (0.90%) and 100 μg L−1 (1.62%) as well as for SCu at concentrations of 0.25 mg L−1 (8.11%), 1 mg L−1 (3.11%) and 5 mg L−1 (0.90%). A comparative evaluation showed a good agreement between the results obtained in the analysis of UCu and SCu (n = 18) by both the developed methodology and the reference procedures. Accuracy was further evaluated by means of the analysis of reference samples (Seronorm™ Trace Elements Urine and Seronorm™ Trace Elements Serum) and the obtained results complied with the certified values.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号