共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel CE method combined with SPE in a single capillary was developed for analysis of chlorophenols in water. A frit of 0.5 mm was first made by a sol-gel method, followed by packing a SPE sorbent in the inlet end of the capillary. Two phenol derivatives, 2,4-dichlorophenol and 2,4,5-trichlorophenol, were used as the model compounds. By loading sample solutions into the capillary, the two chlorophenols were extracted into the sorbent. They were desorbed by injecting only about 4 nL of methanol. Finally, the analytes were separated by conventional CE. The technique provided a concentration enhancement factor of over 4000-fold for both chlorophenols. The detection limits (S/N = 3) of 2,4-dichlorophenol and 2,4,5-trichlorophenol were determined to be 0.1 ng/mL and 0.07 ng/mL, respectively. For replicate analyses of 5 ng/mL of 2,4-dichlorophenol, within-day and between-day RSDs of migration time, peak height and peak area were in the range of 1.8-2.0%, 4.0-4.4% and 4.1-4.6%, respectively. The method shows wide linear range, acceptable reproducibility and excellent sensitivity, and it was applied to the analyses of spiked river water samples. The capillary packed with the SPE sorbents can be used for more than 400 runs without performance deterioration. 相似文献
2.
Soto-Chinchilla JJ García-Campaña AM Gámiz-Gracia L Cruces-Blanco C 《Electrophoresis》2006,27(20):4060-4068
A CZE method with UV-Vis detection has been established and validated for the determination of nine sulfonamides: sulfapyridine, sulfamethazine, sulfamerazine, sulfamether, sulfadiazine, sulfadimethoxine, sulfamethoxazole, sulfachlorpyridazine, and sulfamethizole. Optimum separation was obtained on a 64.5 cm x 75 microm bubble cell capillary using a buffer containing 45 mM sodium phosphate and 10% methanol at pH 7.3, with temperature and voltage of 27 degrees C and 25 kV, respectively. p-Aminobenzoic acid was used as an internal standard . Taking into account the lack of sensitivity of the UV-Vis detection, the application of an on-line preconcentration methodology, such as large-volume sample stacking with polarity switching has been proposed. This procedure combined with a solvent extraction/SPE method applied for off-line preconcentration and cleanup provides a significant improvement in the LODs, ranging from 2.59 to 22.95 mug/L for the studied compounds; the quantification of these residues being possible below the levels established by EU legislation in animal food products, such as meat. Satisfactory recoveries were also obtained in the analysis of these compounds in ground water. 相似文献
3.
Effective sorbents for solid-phase extraction in the analysis of quinolones in animal tissues by capillary electrophoresis 总被引:1,自引:0,他引:1
In this work, several commercial sorbents (Zorbax C18, Bond Elut C18, Isolute ENV+, Oasis HLB, Oasis MAX, SDB-RPS, and MPC-SD) were compared for the solid-phase extraction of the series of quinolones regulated by the European Community in chicken tissues in order to establish a method for the determination of this series of quinolones by capillary electrophoresis and diode array detection. Sorbents were chosen in order to achieve maximum recoveries and optimal clean-up efficiency. Better results were obtained using SDB-RPS and Oasis MAX which would provide suitable limits of detection, below of the maximum residue limits (MRLs) regulated. 相似文献
4.
An on-line sample stacking method, namely field-amplified sample injection, has been developed for the separation and determination of carnosine, anserine, and homocarnosine by capillary electrophoresis. Using electrokinetic injection, about 130- to 160-fold improvement of sensitivity was achieved without loss of separation efficiency when compared to conventional sample injection. For conventional injection, the samples were dissolved in running buffer and then hydrodynamically injected for 10 s (3.45 kPa). Various parameters affecting separation and sample stacking were optimized. Under optimum conditions, linear responses were obtained over two orders of magnitude and the detection limits (defined as S/N = 3) of carnosine, anserine, and homocarnosine were 1.5 x 10(-8) to 1.6 x 10(-8) mol/L. 相似文献
5.
Breadmore MC 《Analytica chimica acta》2006,556(1):121-126
A new frontal electroelution approach that can be used for the preconcentration of amino acids in in-line solid-phase extraction-capillary electrophoresis (SPE-CE) has been developed. A single capillary was employed featuring a short monolithic SPE column created inside the capillary via photo-initiated, free-radical polymerisation of 3-sulfopropyl methacrylate and butyl methacrylate monomers. A weak electrolyte of dilute H2SO4, pH 2.9, was found to promote adsorption of the amino acids onto the SPE column. Elution of the amino acids was achieved using a dual solvation/ion-exchange transient boundary mobilised via EOF by using a strong electrolyte containing 62.5 mM ethylenediamine, pH 2.9 with H2SO4 and 40% (v/v) acetonitrile. Using these two electrolytes, tryptophan was adsorbed onto the SPE column in weak electrolyte and eluted via a frontal electroelution mechanism in the strong electrolyte. Injections up to 20 min, corresponding to over 14 column volumes (or 1400% of the capillary volume) of sample provided quantitative extraction of tryptophan from the weak electrolyte and were eluted without any loss in efficiency. This represents a practical increase of approximately 300-fold when compared to a typical hydrodynamic injection occupying 5% of the capillary volume. 相似文献
6.
This paper proposes a novel strategy to enhance selectivity and sensitivity in CE, using supported liquid membrane (SLM) and off-line SPE simultaneously. The determination of ochratoxin A (OA) in wine has been used to demonstrate the potential of this methodology. In the SLM step, the donor phase (either a 20 mL volume of a standard solution at pH 1 or a wine sample at pH 8) was placed in a vial, where a micromembrane extraction unit accommodating the acceptor phase (1 mL water, pH 11) in its lumen was immersed. The SLM was constructed by impregnating a porous Fluoropore Teflon (PTFE) membrane with a water-immiscible organic solvent (octanol). In the off-line SPE step, the nonpolar sorbent (C-18, 4 mg) selectively retained the target ochratoxin, enabling small volumes of acceptor phase (1 mL) to be introduced. The captured analytes were eluted in a small volume of methanol (0.1 mL). This procedure resulted in sample cleanup and concentration enhancement. The method was evaluated for accuracy and precision, and its RSD found to be 5%. The LODs for OA in the standard solutions and wine samples were 0.5 and 30 microg/L, respectively. The results obtained demonstrate that SLM combined with off-line is a good alternative to the use of immunoaffinity columns prior to CE analysis. 相似文献
7.
Francisco J. Lara Ana M. García-Campaña Christian Neusüss Fermín Alés-Barrero 《Journal of chromatography. A》2009,1216(15):3372-3379
An in-line solid-phase extraction-capillary electrophoresis method with UV–vis detection was developed for the monitoring of residues of five sulfonamides (sulfadoxin, sulfadimethoxine, sulfamerazine, sulfachloropyridazine and sulfamethoxazole) in tap, bottled mineral and river waters. For this purpose an analyte concentrator was constructed, based on the introduction of a small portion of a solid-phase extraction sorbent into the electrophoretic capillary to carry out an in-line concentration step, improving sensitivity. A detailed study was carried out to optimize parameters affecting the in-line solid-phase extraction process, such as the design of the concentrator device, type of sorbent and conditions of elution and injection. The proposed method is simple for the environmental monitoring of these antibiotic residues in waters, allowing the direct injection of the samples without any off-line pretreatment and achieving limits of detection between 0.3 and 0.6 μg/L. Recoveries ranging 52.2–109.2% and relative standard deviations below 13.4% were obtained. 相似文献
8.
Flavonoids are an important bioactive group in the commonly used herbal medicine Flos Lonicerae. A new method of capillary zone electrophoresis (CZE) coupled with solid-phase extraction (SPE) was developed for simultaneous assay of flavonoid aglycones and glycosides in Flos Lonicerae. Optimum CZE separation was achieved with a background electrolyte (BGE) solution consisting of 80 mM boric acid and 20 mM phosphate acid, adjusted to pH 8.1, with 15% acetonitrile (v/v) added, and applying a separation voltage of 28 kV. The SPE method was used for pretreating the complex matrix of botanical materials and good reproducibility was obtained when avicularin was used as internal standard. Linearity of the method was excellent with correlation coefficients (r2) in the range of 0.9995-0.9999 and detection limits were lower than 0.6 microg/mL for the four flavonoids. The obtained recoveries varied between 93 to 104% while the relative standard deviations (RSDs) were below 4.4% (n=3). The developed CZE method was successfully used for the separation of eight flavonoids and the quantification of the four flavonoids in five species of Flos Lonicerae. 相似文献
9.
This study describes approaches for stacking a large volume of sample solutions containing a mixture of mercaptopurine monohydrate, 6-methylmercaptopurine, thioguanine, thioguanosine, and thioxanthine in capillary electrophoresis (CE). After filling the run buffer (60 mM borate buffer, pH 8.5), a large sample volume was loaded by hydrodynamic injection (2.5 psi, 99.9 s), followed by the removal of the large plug of sample matrix from the capillary using polarity switching (-15 kV). Monitoring the current and reversing the polarity when 95% of current recovered, the separation of anionic analytes was performed in a run buffer < 20 kV. Around 44- to 90-fold improvement of sensitivity for five analytes was achieved by large-volume stacking with polarity switching when compared with CE without stacking. This method was feasible for determination of the analytes spiked in plasma. Removing most of electrolytes from plasma is a key step for performing large-volume sample stacking. Solid-phase extraction was used for pretreatment of biological samples. To our knowledge, this study is one of few applications showing the possibilities of this stacking procedure to analyze biological samples by large-volume sample stacking with polarity switching (LVSSPS) in CE. 相似文献
10.
A hollow fiber-based liquid-liquid-liquid microextraction (HF-LLLME) combined with on-line large-volume sample stacking (LVSS) has been developed for the speciation of organomercury in biological samples by CE with UV detection. Separation was achieved in less than 11 min with an electrolyte consisting of 35 mM sodium tetraborate at pH 9.1. In LVSS, a reverse electrode polarity-stacking mode (REPSM) was applied as on-line preconcentration strategy. In HF-LLLME, the analytes were extracted from 12 mL volume of sample solution (pH adjusted to 3.0) into bromobenzene impregnated in the pores of the hollow fiber, and into an acceptor solution of L-cysteine (15 microL, 0.02% w/v) inside the hollow fiber. Under the optimized conditions, concentration factors of 2610-4580 were achieved and LODs in the range of 0.03-0.14 microg/L were feasible. The linearity was found to be over two orders of magnitude with correlation coefficient of 0.9991-0.9996. The developed method has been validated using a certified reference material (DORM-2, dogfish muscle), and the determined values coincided very well with the certified values. The method was also applied to the speciation of organomercury in three kinds of fish samples and human hair samples. 相似文献
11.
This report describes a novel online field-amplified sample stacking (FASS) procedure to analyze 16 chlorinated acid herbicides. By using a poly(vinyl alcohol) (PVA)-coated capillary to reduce electroosmotic flow and introducing a methanol-water plug before sample loading, the sample injection time could be very long without loss of sample and separation efficiency. Under the optimized condition, the FASS procedure could provide great sensitivity enhancement (5000-10 000-fold) and satisfactory reproducibility (relative standard deviations of migration times less than 2.4%, relative standard deviations of peak areas less than 8.0%). Combined with cationic surfactant-assisted solid-phase extraction (CSA-SPE), the limit of detection of the herbicides ranged from 0.269 to 20.3 ppt, which are two orders lower than those of the US Environmental Protection Agency standard method 515.1. The CSA-SPE-FASS-CE method was successfully applied to the analysis of local pond water. 相似文献
12.
Large-volume sample stacking using the electroosmotic flow (EOF) pump (LVSEP) has been used to analyze some nonsteroidal anti-inflammatory drugs (NSAIDs) in water samples. With methanol as the run buffer solvent to suppress the EOF, sensitivity was enhanced by 80-100-fold. The sample for the analysis of real water sample was pretreated by solid-phase extraction (SPE). When the method was based on off-line SPE-LVSEP-CE, sensitivity improved by as much as 1000 times. 相似文献
13.
14.
The paper advanced the theoretical procedures for quantitative design on selective stacking of zwitterions in full capillary sample matrix by a cathodic-direction moving reaction boundary (MRB) in capillary electrophoresis (CE) under control of electroosmotic flow (EOF). With the procedures, we conducted the theoretical computations on the selective stacking of two test analytes of L-histidine (His) and L-tryptophan (Trp) by the MRB created with 30 mM pH 3.0 formic acid-NaOH buffer and 2-80 mM sodium formate. The results revealed the following three predictions. At first, the MRB cannot stack His and Trp plugs if less than 12.5 mM sodium formate is used to form the MRB and prepare the sample matrix. Second, the MRB can stack His and/or Trp sample plugs completely if higher than 50 mM sodium formate is chosen to form the MRB. Third, the MRB can only focus His plug completely, but stack Trp plug partially if 20-50 mM sodium formate is used; this implied the complete MRB-induced selective stacking to His rather than Trp. All the three predictions were quantitatively proved by the experiments. With great dilution of sample matrix and control of EOF, controllable, simultaneous and MRB-induced selective stacking and separation of zwitterions were achieved. The theoretical results hold evident significances to the quantitative design of selective stacking conditions and the increase of detection sensitivity of zwitterions in CE. In addition, the control of EOF by cetyltrimethylammonium bromide (CTAB) can evidently improve the stacking efficiency to both His and Trp. 相似文献
15.
Capillary electrophoresis (CE) has been investigated for the analysis of some neurotransmitters, dopamine (DA), 3-methoxytyramine (3-MT) and serotonin (5-hydroxytryptamine, 5-HT) at nanomolar concentrations in urine. Field-amplified sample injection (FASI) has been used to improve the sensitivity through the online pre-concentration samples. The cationic analytes were stacked at the capillary inlet between a zone of low conductivity - sample and pre-injection plug - and a zone of high conductivity - running buffer. Several FASI parameters have been optimized (ionic strength of the running buffer, concentration of the sample protonation agent, composition of the sample solvent and nature of the pre-injection plug). Best results were obtained using H3PO4–LiOH (pH 4, ionic strength of 80 mmol L−1) as running buffer, 100 μmol L−1 of H3PO4 in methanol–water 90/10 (v/v) as sample solvent and 100 μmol L−1 of H3PO4 in water for the pre-injection plug.In these conditions, the linearity was verified in the 50–300 nmol L−1 concentration range for DA, 3-MT and 5-HT with a determination coefficient (r2) higher than 0.99. The limits of quantification (10 nmol L−1 for DA and 3-MT, 5.9 nmol L−1 for 5-HT) were 500 times lower than those obtained with hydrodynamic injection. However, if this method is applied to the analysis of neurotransmitters in urine, the presence of salts in the matrix greatly reduces the sensitivity of the FASI/CE–UV method.Therefore, a solid phase extraction (SPE) on a dedicated imprinted polymer (MIP) was developed to extract specific neurotransmitters, catecholamines, metanephrines and indolamines, from urine. Matrix salts were thus discarded after sample extraction on AFFINIMIP™ Catecholamine & Metanephrine (100 mg) cartridge.Therefore, lower limits of quantification were determined in artificial urine (46 nmol L−1 for DA, 11 nmol L−1 for 3-MT and 6 nmol L−1 for 5-HT).The application of this protocol MIP-SPE/FASI–CE–UV analysis of neurotransmitters in human urine gave rise to electropherograms with a very good base line and signal to noise ratios above 15. 相似文献
16.
This study investigates an off-line solid phase extraction (SPE) for improving the sensitivity in the capillary electrophoretic
(CE) analysis of four cephalosporins. Two sorbents—LiChrolut-C18 and Oasis HLB—were used in a SPE process to detect cephalosporins in natural waters (tap, river and hospital sewage) and
their performances were compared. By using Oasis HLB sorbent higher recoveries for river water were obtained (94–107% when
500 mL of sample were analyzed). The off-line SPE–CZE method was validated for river water with good detection limits (3 μg L−1) and the linearity ranged between 5 and 200 μg L−1. 相似文献
17.
A capillary zone electrophoresis (CZE) method with ultraviolet-visible detection has been established and validated for the determination of five phenothiazines: thiazinamium methylsulfate, promazine hydrochloride, chlorpromazine hydrochloride, thioridazine hydrochloride, and promethazine hydrochloride in human urine. Optimum separation was obtained on a 64.5 cm x 75 microm bubble cell capillary using a buffer containing 150 mM tris(hydroxymethyl)aminomethane and 25% acetonitrile at pH 8.2, with temperature and voltage of 25 degrees C and 20 kV, respectively. Naphazoline hydrochloride was used as an internal standard. Field-amplified sample injection (FASI) has been applied to improve the sensitivity of the detection. Considering the influence of parameters affecting the on-line preconcentration (nature of preinjection plug, sample solvent composition, injection times, and injection voltage) and due to the significant interactions among them, in this paper we propose for the first time the application of a multivariate approach to carry out the study. The optimized conditions were as follows: preinjection plug of water for 7 s at 50 mbar, electrokinetic injection for 40 s at 6.2 kV, and 32 microm of H3PO4 in the sample solvent. Also, a solid-phase extraction (SPE) procedure is developed to obtain low detection limits and an adequate selectivity for urine samples. The combination of SPE and FASI-CZE-UV allows adequate linearities and recoveries, low detection limits (from 2 to 5 ng/mL), and satisfactory precisions (3.0-7.2% for an intermediate RSD %). 相似文献
18.
We describe a method for the simultaneous determination of the five fibrinopeptide forms derived from the thrombin-promoted activation of human fibrinogen by capillary zone electrophoresis (CZE). The fibrinopeptide mixture was first desalted by a solid-phase extraction (SPE) step. The analysis was performed in reversed polarity in a highly cross-linked polyethylene glycol (PEG)-coated capillary with UV-light absorption detection at 200 nm. Several parameters including buffer concentration and pH, presence of an organic modifier, temperature, and applied voltage, have been tested. The best separations were obtained within 20 min, utilizing a 20 mM sodium phosphate buffer without organic modifier, in the narrow 6.1-6.2 pH range, at 25 degrees C, with an applied voltage of 20 kV. Quantitative analysis is made possible by the use of sheep fibrinopeptide A as an internal standard to correct for both extraction and injection errors. 相似文献
19.
On-line determination of the anti-tumor drug 5-fluorouracil (5-FU) and its prodrug, tegafur (TF) was achieved for the first time by capillary electrophoresis with large-volume sample stacking (CE-LVSS). The optimal electrophoretic buffer consisted of 30 mM phosphate buffer at pH 8.0. Without the LVSS procedure, the limits of detection (LOD) were 600.5 ng/mL and 771.4 ng/mL for 5-FU and TF, respectively. With the LVSS procedure, the sensitivity was significantly improved by about two orders of magnitude (the LODs of 5-FU and TF were decreased to 7.9 ng/mL and 6.5 ng/mL, respectively). The %RSD was less than 5%. This method compared favorably with other reported techniques and was applied successfully to the quantitative analysis of anti-tumor drugs in commercial injection preparations. The results show that the method is simple, fast (less than 3 min), highly selective, and sensitive. 相似文献
20.
Marcos Tascon Fernando Benavente Victoria Sanz-Nebot Leonardo G. Gagliardi 《Analytica chimica acta》2015
A novel high performance system to control the temperature of the microcartridge in on-line solid phase extraction capillary electrophoresis (SPE–CE) is introduced. The mini-device consists in a thermostatic bath that fits inside of the cassette of any commercial CE instrument, while its temperature is controlled from an external circuit of liquid connecting three different water baths. The circuits are controlled from a switchboard connected to an array of electrovalves that allow to rapidly alternate the water circulation through the mini-thermostatic-bath between temperatures from 5 to 90 °C. The combination of the mini-device and the forced-air thermostatization system of the commercial CE instrument allows to optimize independently the temperature of the sample loading, the clean-up, the analyte elution and the electrophoretic separation steps. 相似文献