首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Fluorotelomer alcohols (FTOHs) are important polyfluorinated raw materials that belong to the general category of perfluoroalkyl substances (PFAS). PFAS, including perfluoroalkyl carboxylates (PFCAs) and perfluoroalkyl sulfonates, have recently attracted considerable attention because they are persistent and found globally in the environment. FTOHs are precursors that may degrade in the environment to PFCAs. The development of analytical methods for determination FTOHs in environmental samples is necessary to determine the environmental presence of FTOHs. This work presents the development and validation of a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of FTOHs (6-2, 8-2, 10-2) in aqueous samples. Chromatographic conditions were optimized in order to obtain focused FTOH chromatographic peaks. The mobile phase and mass spectrometric conditions were optimized to enable formation of deprotonated FTOH molecules in the negative ion electrospray mode. Two extraction methods were investigated using acetonitrile and methyl tert-butyl ether (MTBE). These methods were validated for a range of environmental water samples fortified with FTOHs at three different levels. Both extraction methods resulted in recoveries from 70 to 120%. Detection limits of FTOHs were estimated to be approximately 0.09 ng/mL for LC/MS/MS detection. An LC/MS method was also developed for FTOH determination with an estimated 1.2 ng/mL limit of detection. Various sample storage scenarios were investigated. It was determined that the aqueous samples of FTOHs are best preserved by storing them frozen in sealed vials with aluminum foil lined septa.  相似文献   

2.
The potential of liquid chromatography combined with tandem mass spectrometry (LC/MS/MS) for the determination of pesticide metabolites in human urine at the sub-ppb level is explored. Metabolites from two organophosphorous pesticides, 4-nitrophenol (from parathion and parathion-methyl) and 3-methyl-4-nitrophenol (from fenitrothion), are taken as model analytes to conduct this study. After direct injection of the urine sample (10 microL), different approaches were evaluated in order to achieve correct quantitation of analytes using an electrospray ionisation (ESI) interface. Thus, the feasibility of using external calibration was checked versus the use of different isotope-labeled internal standards. The advantages of applying coupled-column liquid chromatography (LC/LC) as an efficient clean-up without any type of sample manipulation are also discussed. The combination of LC/LC with ESI-MS/MS allows the direct analysis of free metabolites in urine, as the automated clean-up performed by the coupled-column technique is sufficient for the removal of interferences that suppress the ionisation of analytes in the ESI source. Using this procedure with external calibration, good precision and recoveries, and detection limits below 1 ng/mL are reached with analysis run times of around 8 min. The hyphenated technique LC/LC/ESI-MS/MS is proved to be a powerful analytical tool, allowing the rapid, sensitive and selective determination of 4-nitrophenol and 3-methyl-4-nitrophenol in human urine without any sample treatment.  相似文献   

3.
A liquid chromatographic (LC) method was developed for the determination of emamectin and its metabolites (8,9-Z-isomer, N-demethylated, N-formylated, and N-methylformylated emamectin) in various crops. The analytes were extracted with acetone, cleaned up on cartridge columns (C18 and NH2), derivatized with trifluoroacetic anhydride and 1-methylimidazole, and determined by LC with fluorescence detection. Because radish inhibited the formation of the fluorescent derivatives, an additional Bond Elut PRS cartridge was used in the cleanup of Japanese radish samples. During sample preparation, N-formylated emamectin partially degraded to emamectin B1b and emamectin B1a, and the 8,9-Z-isomer partially degraded to N-demethylated emamectin. Therefore, emamectin and its metabolites were determined as total emamectin, i.e., their sum was estimated as emamectin benzoate. Their recoveries from most crops were approximately 80-110% with the developed method. The detection limits for the analytes in vegetables were 0.1-0.3 parts per trillion (ppt). The results for these compounds were confirmed by LC/mass spectrometry (LC/MS; electrospray ionization mode). Because the fluorescent derivative of emamectin was undetectable by LC/MS, the results for the analyte were confirmed by using a sample solution without derivatization. Limits of detection by LC/MS were similar to the fluorescence detection limits, 0.1-0.3 ppt in vegetables. In addition to the emamectins, milbemectin, ivermectin, and abamectin were also determined by the developed method.  相似文献   

4.
The performance of three different types of mass spectrometers (MS) coupled to high performance liquid chromatography (HPLC) was compared for trace analysis of perfluoroalkylated substances (PFAS) and fluorotelomer alcohols (FTOHs). Ion trap MS in the full scan and product ion MS2 mode, time-of-flight (TOF) high resolution MS and quadrupole MS in the selected ion mode as well as triple quadrupole tandem MS were tested. Electrospray ionisation in the negative ion mode [ESI-] was best suited for all instruments and compounds. PFAS could only be separated by a buffered mobile phase, but the presence of buffer suppressed the ionisation of FTOHs. Therefore, two independent chromatographic methods were developed for the two compound classes. Mass spectra and product ion spectra obtained by in-source and collision induced dissociation fragmentation are discussed including ion adduct formation. Product ion yields of PFAS were only in the range of 0.3 to 12%, independent from the applied MS instrument. Ion trap MS2 gave product ion yields of 20 to 62% for FTOHs, whereas only 4.1 to 5.8% were obtained by triple quadrupole tandem MS. Ion trap MS was best suited for qualitative analysis and structure elucidation of branched isomeric structures of PFAS. Providing typical detection limits of 5 ng injected in MS2 mode, it was not sensitive enough for selective trace amount quantification. TOF high resolution MS was the only technique combining high selectivity and excellent sensitivity for PFAS analysis (detection limits of 2 to 10 pg), but lacked the possibility of MS-MS. Triple quadrupole tandem MS was the method of choice for quantification of FTOHs with detection limits in the low pg range. It is also well suited for the determination of PFAS, though its detection limits of 10 to 100 pg in tandem MS mode are about one order of magnitude higher than for TOF MS.  相似文献   

5.
A method was developed for screening crops for a range of pesticide residues by liquid chromatography/tandem mass spectrometry (LC/MS/MS). A complete set of LC, electrospray ionization (ESI), and tandem MS acquisition parameters was established for the determination of 108 analytes; these parameters were used for the simultaneous acquisition of 98 analytes in the positive ESI mode and 10 analytes in an additional MS/MS method in the negative ESI mode. The entire procedure involves extraction of residues with methanol-water and partition into dichloromethane. The utility of the method is demonstrated by the analysis of crops of 5 matrix types (water-containing, acidic, dry, sugar-containing, and fatty). Of 108 pesticides/metabolites tested, 104 showed sufficient stability in most matrixes for determination by LC/MS/MS. These analytes belong to 20 chemical classes, which demonstrate the general applicability of the method for multiclass analysis. By using matrix-matched standards, 67 compounds could be determined in most matrixes with recoveries of 70-120% and a relative standard deviation of < or = 25% at the 0.01 mg/kg level.  相似文献   

6.
A sensitive, high performance liquid chromatography/tandem mass spectrometric (i.e. mass spectrometry/mass spectrometry; LC/MS/MS) method with on-line extraction and sample clean-up for the screening and confirmation of residues of sulfonamides in kidney is described. The sulfonamides are extracted from homogenized kidney with methanol. After centrifugation of the extract, an aliquot of the extract is directly injected on the LC/MS/MS system with further extraction and clean-up of the sample on-line. Detection of the analytes was achieved by positive electrospray ionization (ESI) followed by multiple reaction monitoring. For each sulfonamide the collisional decomposition of the protonated molecule to a common, abundant fragment ion was monitored. The method has been validated for sulfadimethoxine, sulfaquinoxaline, sulfamethazine, sulfamerazine, sulfathiazole, sulfamethoxazole, sulfadiazine and sulfapyridine. Calibration curves resulting from spiked blank kidney samples at the 10-200 microg/kg level showed good linear correlation. At the level of 50, 100 and 200 microg/kg both within- and between-day precision, as measured by relative standard deviation (RSD), were less than 16%. The limits of detection (LODs) ranged from 5 to 13.5 microg/kg. The recoveries ranged from 78 to 82%. The procedure provides a rapid, reliable and sensitive method for the determination of residues of sulfonamides in bovine kidney. The advantage of this method over existing methods is its decreased sample preparation and analysis time, which makes the method more suitable for routine analysis.  相似文献   

7.
The aim of this work is to establish a method for the simultaneous determination of eight penicillins in milk samples by LC‐UV, LC‐MS and LC‐MS/MS. The procedure involves a step for clean‐up and to preconcentrate the analytes by SPE and a subsequent chromatographic analysis. LC‐UV, LC‐MS and LC‐MS/MS have been used for the simultaneous quantification of penicillins in milk. The proposed methods have been validated according to the EU guideline and present LOQ below the maximum limits of residues (MRLs) established by the European Union for penicillins in milk. The developed methods were applied to different milk samples obtained from cows medicated with penicillins.  相似文献   

8.
This study is the first to evaluate the rate of formation of perfluorooctanoate (PFO) from the aerobic biodegradation of a fluorotelomer-based urethane polymer and to use this information to assess the global environmental significance of this source. A fluorotelomer-based urethane polymer product test substance was studied in four aerobic soils over two years to determine the rate at which the fluorotelomer side-chains covalently bonded to the polymer backbone were cleaved and subsequently transformed to form the anions of perfluorocarboxylic acids including PFO. Over the two year duration of the experimental study, a polymer biodegradation half-life of 102 years (range: 28-241) was calculated for the urethane polymer based on regression analysis of the rate of PFO formation in four test soils. When this half-life was applied to the estimated total historic production, use and disposal of fluorotelomer-based urethane polymer, the annual potential global generation of PFO was estimated to be less than one tonne per year.  相似文献   

9.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for simultaneous quantification of docetaxel and ketoconazole in rat plasma with paclitaxel as internal standard (IS). The analytes were extracted from rat plasma by using a liquid-liquid extraction technique with ethyl acetate and the LC separation was performed on a Cosmosil-C(18) analytical column (150 mm x 2.0 mm i.d., Nacalai Tesque Inc., Japan). The extracted samples were analyzed with LC/MS/MS, operating in selected reaction monitoring (SRM) mode. The SRM transitions of precursor ions to product ions were 830.3-->549.1 (m/z) for docetaxel, 531.2-->489.3 (m/z) for ketoconazole, and 876.7-->307.9 (m/z) for the IS. The calibration curves were linear over the range of 2-500 ng/mL for docetaxel and 50-20 000 ng/mL for ketoconazole, with coefficients of correlation above 0.999. The limits of quantification for docetaxel and ketoconazole were both 2 ng/mL. The limit of detection for each analyte was 1 ng/mL. The intra- and inter-day precision (CV) of analysis were within 7%, and the accuracy ranged from 95 to 110%. The overall recoveries for docetaxel and ketoconazole were about 89.0% and 91.1%, respectively. The total analysis time was only 9.0 min. This quantitation method was successfully applied to the simultaneous determination of docetaxel and ketoconazole in rat plasma and some potential interaction was found in the current coadministration pharmacokinetic study. This established method was also utilized in the in vitro and in vivo drug-drug interaction study of docetaxel and ketoconazole (to be published).  相似文献   

10.
Saflufenacil is a new protoporphyrinogen‐IX‐oxidase inhibitor herbicide. When used, it can enter the soil and has a high risk to reach and contaminate groundwater and aquatic systems. A rapid and sensitive method of ultra‐performance LC with MS/MS was developed for the simultaneous determination of saflufenacil and its two metabolites in soil samples. A modified quick, easy, cheap, effective, rugged, and safe method was applied as the pretreatment procedure. The method was validated by five types of soil samples collected from several regions of China, which all showed good linearity (R2 ≥ 0.9914) and precision (RSD ≤ 26.2%). The average recoveries of the three analytes ranged between 74.1 and 118.9% at spiking levels of 3–300 μg/kg. The method limits of detection (S/N 3:1) and method limits of quantification (S/N 10:1) achieved are in the ranges of 0.25–2.75 and 0.83–9.16 μg/kg, respectively. This indicated that the developed ultra‐performance LC with MS/MS method is a promising analytical tool for monitoring the environmental risks posed by saflufenacil.  相似文献   

11.
A sensitive and effective method for the simultaneous quantitative determination of aminopyralid, clopyralid, and picloram in vegetables (eggplant, cucumber, and tomato) and fruits (apple and grape) was developed and validated using ultra-performance LC coupled with MS/MS. The three herbicides were successfully separated and independently confirmed in a single run. Different extraction and cleanup methods were used to optimize the pretreatment processes of the residue analysis method. The final method is straightforward and involves extraction with 1% formic acid-acetonitrile, and no complicated cleanup process is needed. Determination of the compounds was achieved within 3.0 min. Respective average recoveries using this method at four concentration levels (0.05, 0.1, 0.5, and 1.0 mg/kg) ranged from 66.5 to 109.4%, with RSDs in the range of 1.1-19.7% (n = 5) for all analytes. The LODs were below 0.010 mg/kg, and the LOQs did not exceed 0.036 mg/kg, which were lower than the maximum residue limits (MRLs) of 0.5-5.0 mg/kg clopyralid in vegetables and fruits samples, as established by the European Union. This study provides a theoretical basis for China to develop MRLs and an analytical method for aminopyralid, clopyralid, and picloram in vegetables and fruits.  相似文献   

12.
This article describes the development of an analytical method for the determination of fluorotelomer alcohols (FTOHs) in soil. The sensitive and selective determination of the telomer alcohols was performed by extraction with methyl tert-butyl ether (MTBE) and analysis of the extract using gas chromatography with detection and quantification by mass spectrometry operated in the positive chemical ionization mode. The protonated molecular ion, [M+H]+ and a fragment ion (loss of HF + H2O) m/z 38 less than the molecular ion were monitored to identify tentatively FTOHs in MTBE extracts of contaminated soils. The FTOHs were confirmed by treatment of the extract with a silylation reagent and observing the disappearance of the FTOH response and the appearance of peaks attributable to the [M+H]+ ions of the trimethylsilyl derivatives. Mass-labeled FTOHs were used as recovery and matrix internal standards. Recovery experiments on soils shown to be free of endogenous FTOHs at instrument detection limits (IDL) of 16 fg/μL for 6:2 FTOH, 10 fg/μL for 8:2 FTOH and 14 fg/μL for 10:2 FTOH yielded a limit of quantitation (LOQ) of 190, 100, and 160 fg/μL for 6:2 FTOH, 8:2 FTOH, and 10:2 FTOH, respectively when 3 g samples of soil were extracted with 1 mL MTBE. The levels of the 6:2 FTOH, 8:2 FTOH, and 10:2 FTOH in five soils contaminated with FTOHs by exposure to the laboratory atmosphere during air drying were determined. In these air-dried soils, concentrations of FTOHs ranged from non-detectable to 3600 fg/μL (0.6 ng/g) of the 6:2 FTOH in the extract of a commercial topsoil. This method was used to determine even and odd numbered FTOHs from 6:2 through 14:2 in soils from fields that had received applications of sewage sludge. Concentrations of FTOHs in these sludge-applied soils ranged as high as 820 ng/g of dry soil for the 10:2 FTOH.  相似文献   

13.
A rapid and sensitive method for the simultaneous confirmatory analysis of three forensic most relevant cannabinoids, Delta(9)-tetrahydrocannabinol (THC), 11-hydroxy-Delta(9)-tetrahydrocannabinol (11-OH-THC) and 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol (THC-COOH), by means of high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) in human plasma was developed and fully validated. Sample clean-up was performed by automated silica-based solid-phase extraction and the separation was carried out using a PhenylHexyl column (50 x 2 mm i.d., 3 micro m) and acetonitrile-5 mM ammonium acetate gradient elution. Data were acquired with an API 3000 LC/MS/MS system equipped with a turboionspray interface and triple quadrupole mass analyzer using positive electrospray ionization and multiple reaction monitoring. Two MS/MS transitions for each substance were monitored and deuterated analogues of analytes were used as internal standards for quantitation. The limit of quantitation was 0.8 ng ml(-1) for THC, 0.8 ng ml(-1) for 11-OH-THC and 4.3 ng ml(-1) for THC-COOH and linearity with a correlation coefficient r(2) = 0.999 was achieved up to 100 ng ml(-1) for THC and 11-OH-THC and 500 ng ml(-1) for THC-COOH. The limits of detection were 0.2 ng ml(-1) for THC, 0.2 ng ml(-1) for 11-OH-THC and 1.6 ng ml(-1) for THC-COOH. The developed LC/MS/MS method was also successfully used for the determination of THC-COOH-glucuronide, the phase II metabolite of THC-COOH.  相似文献   

14.
A novel, sensitive, high performance liquid chromatography/tandem mass spectrometric (i.e. mass spectrometry/mass spectrometry) method with on-line extraction and clean-up for the screening and confirmation of residues of tetracyclines in kidney has been developed. After liquid extraction of homogenised kidney with McIlvain buffer, an aliquot of the extract is directly injected on the LC/MS/MS system with further extraction and clean-up of the sample on-line. Detection of the analytes was achieved by positive electrospray ionization followed by multiple reaction monitoring. For each tetracycline the collisional decomposition of the protonated molecule to a unique, abundant fragment ion was monitored. The method has been validated for tetracycline, oxytetracycline, chlortetracycline and doxycycline. Calibration curves resulting from spiked blank kidney samples at the 100-1200 microgram/kg level showed good linear correlation. At the level of 600 microgram/kg both within- and between-day precision, as measured by relative standard deviation (RSD), were less than 7%. The limits of detection (LODs) for tetracycline, oxytetracycline, chlortetracycline and doxycyline were 18, 23, 24 and 21 microgram/kg, respectively. The limits of quantification (LOQs) for tetracycline, oxytetracycline, chlortetracycline and doxycyline were 36, 46, 47 and 42 microgram/kg, respectively. The recoveries ranged from 71 to 91%. The procedure provides a rapid, reliable and sensitive method for the determination of residues of tetracyclines in bovine kidney. The advantage of this method over existing methods is its decreased sample preparation and analysis time, which makes the method more suitable for routine analysis.  相似文献   

15.
Oxcarbazepine (OX), a new antiepileptic, may lead to unwanted side-effects or even life-threatening intoxications after overdose. Therefore, a validated liquid chromatographic/mass spectrometric (LC/MS) assay was developed for the quantification of OX and its pharmacologically active dihydro metabolite (dihydrooxcarbazepine, DOX, often named 10-hydroxycarbazepine). OX and DOX were extracted from plasma by the authors' standard liquid/liquid extraction and were separated on a Merck LiChroCART column with Superspher 60 RP Select B as the stationary phase. Gradient elution was performed using aqueous ammonium formate and acetonitrile. The compounds were quantified in the selected-ion monitoring mode using atmospheric pressure chemical ionization electrospray LC/MS. The assay was fully validated. It was found to be selective. The calibration curves were linear from 0.1 to 50 mg l(-1) for OX and DOX. Limits of quantification were 0.1 mg l(-1) for OX and DOX. The absolute recoveries were between 60 and 86%. The accuracy and precision data were within the required limits. The analytes in frozen plasma samples were stable for at least 1 month. The method was successfully applied to several authentic plasma samples from patients treated or intoxicated with OX. The measured therapeutic plasma levels ranged from 1 to 2 mg l(-1) for OX and from 10 to 40 mg l(-1) for DOX. The validated LC/MS assay proved to be appropriate for quantification of OX and DOX in plasma for clinical toxicology and therapeutic drug monitoring purposes. The assay is part of a general analysis procedure for the isolation, separation and quantification of various drugs and for their full-scan screening and identification.  相似文献   

16.
A novel and rapid procedure based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the determination of dialkyl phosphates (metabolites of organophosphorus pesticides) in human urine has been developed. After addition of 40 mM tetrabutylammonium acetate, 10 microL of urine sample were directly injected into the LC/MS/MS system. The method was validated yielding calibration curves with correlation coefficients greater than 0.997 and repeatability coefficient of variation (CV) lower than 9%. The accuracy and precision were evaluated by direct injection of spiked samples at 10 and 100 microg/L obtaining recoveries between 78 and 119% with coefficients of variation below 12%. Limits of detection of 1 microg/L for diethyl phosphate (DEP), diethylthiophosphate (DETP) and diethyldithiophosphate (DEDTP) and 2 microg/L for dimethyldithiophosphate (DMDTP) were achieved, all the analytes being detected in negative ion mode. The fragmentation pathway of dialkyl phosphates allowed us the use of an additional transition for confirmation in order to improve their identification in real-world samples. The applicability of the LC/MS/MS method was demonstrated by applying it to the analysis of urine samples of farmers exposed to the organophosphorus pesticide chlorpyrifos. Good correlation between application of the product in the field (citrus orchards), concentration levels of dialkyl phosphates and levels of the chlorpyrifos-specific metabolite (1,3,5-trichloro-2-pyridinol) was obtained.  相似文献   

17.
Diazepam and its major metabolites, nordazepam, temazepam and oxazepam, in human urine samples, were analyzed by liquid chromatography (LC)/tandem mass spectrometry (MS/MS) using a hydrophilic polymer column (MSpak GF-310 4B), which enables direct injection of crude biological samples. Matrix compounds in urine were eluted first from the column, while the target compounds were retained on the polymer stationary phase. The analytes retained on the column were then eluted into an acetonitrile-rich mobile phase using a gradient separation technique. All compounds showed base-peak ions due to [M+H]+ ions on LC/MS with positive ion electrospray ionization, and product ions were produced from each [M+H]+ ion by LC/MS/MS. Quantification was performed by selected reaction monitoring. All compounds spiked into urine showed method recoveries of 50.1-82.0%. The regression equations for all compounds showed excellent linearity in the range of 0.5-500 ng/mL of urine. The limits of detection and quantification for each compound were 0.1 and 0.5 ng/mL of urine, respectively. The intra- and inter-day coefficients of variation for all compounds in urine were not greater than 9.6%. The data obtained from actual determination of diazepam and its three metabolites, oxazepam, nordazepam and temazepam, in human urine after oral administration of diazepam, are also presented.  相似文献   

18.
A new method for simultaneous determination of amiloride and hydrochlorothiazide by liquid chromatography/electrospray tandem mass spectrometry (LC/MS/MS) operated in positive and negative ionization switching mode was developed and validated. Protein precipitation with acetonitrile was selected for sample preparation. The analytes were separated on a Phenomenex Curosil-PFP (250x4.6 mm, 5 microm) column by a gradient elution with a mobile phase consisting of 0.15% formic acid solution containing 0.23% ammonium acetate and methanol pumped at a flow rate of 1.0 mL.min(-1). Rizatriptan was used as the internal standard (IS) for quantification. The determination was carried out on a Waters Quattro-micro triple-quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode using the following transitions monitored simultaneously: positive m/z 230-->171 for amiloride, m/z 270-->158 for rizatriptan, and negative m/z 296-->205 for hydrochlorothiazide. The lower limits of quantification (LLOQs) were 0.1 and 1.0 ng.mL(-1) for amiloride and hydrochlorothiazide, respectively, which were lower than other published methods by using ultraviolet (UV), fluorimetric or mass spectrometric detection. The intra- and inter-day precision and accuracy were studied at three different concentration levels and were always better than 15% (n=5). This simple and robust LC/MS/MS method was successfully applied to the pharmacokinetic study of compound amiloride and hydrochlorothiazide tablets in healthy male Chinese volunteers.  相似文献   

19.
Development of a rapid, sensitive and selective method for the determination of antimigraine drugs from human serum is essential for understanding the pharmacokinetics of these drugs when administered concurrently. Solid phase extraction (SPE) using Oasis HLB was used to extract the drugs (sumatriptan, naratriptan, zolmitriptan and rizatriptan) and the internal standard bufotenine from serum. A method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and validated to simultaneously quantitate these antimigraine drugs from human serum. The precursor and major product ions of the analytes were monitored on a triple quadrupole mass spectrometer with positive ion electrospray ionization (ESI) in the multiple reaction monitoring (MRM) mode. The base peak in all the analytes is formed by alpha cleavage associated with protonation of the secondary amine. Mechanisms for the formation of the collision-induced dissociation products of these antimigraine compounds are proposed. Linear calibration curves were generated from 1-100 ng/mL with all coefficients of determination greater than 0.99. The inter- and intraday precision (%RSD) were less than 9.3% and accuracy (%error) was less than 9.8% for all components. The limits of detection (LOD) for the method were 250 pg/mL for sumatriptan and 100 pg/mL for the remaining analytes based on a signal-to-noise ratio of 3.  相似文献   

20.
A simple and rapid method using reversed-phase liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the simultaneous determination of the urinary metabolites of benzene, toluene, xylene and styrene in human urine specimens and standard solutions is described. A hybrid quadrupole/time-of-flight (QqTOF) mass spectrometer was compared for the determination of metabolite of aromatic solvents in urine samples. The metabolites selected were: trans,trans-muconic acid, hippuric acid, o-, m- and p-methylhippuric acid and phenylglyoxylic acid. The compounds were well separated from each other on narrow-bore 1-mm i.d. reversed-phase LC C-18 columns. Average recoveries for loading 100 microL of urine samples varied from 88-110% and the quantification limits were less than 30 ng/mL for each analyte (3 ng/mL for trans,trans-muconic acid). The qualitative information obtained (mass accuracy, resolution and full-scan spectra) with the QqTOF mass spectrometer allows a secure identification of analytes in biological matrices.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号