首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary This paper describes the development of a chromatographic system for analysis of commercial ceramides structurally similar to those found in the stratum corneum. The ceramides used in this study contain different amine based (phytosphingosine, sphingosine and dihydrosphingosine) and fatty acids of different chain lengths and with different functional groups (hydroxylated and unsaturated). Non-aqueous reversed-phase (NARP) liquid chromatography with evaporative light-scattering detection (ELSD) were the techniques chosen in accordance with the nature of the ceramides. The eluent strength and the potential selectivity of different organic solvents were investigated. On a C18-bonded silica, the most promising chromatographic conditions employed a gradient from ACN-THF, 95∶5, to ACN-THF-PrOH, 35∶5∶60, in 15 min with a constant concentration of TEA (10 mM) and a stoichiometric amount of formic acid.  相似文献   

2.
Summary The retention prediction system assisted by a micro-computer coupled with an UV multichannel detector has been investigated in the separation of polycyclic aromatic hydrocarbons. The method offered very precise identification of components in NBS-SRM-1647 sample without any standard reference substances. It has been proven that the system makes very precise, non-pollutive and convenient environmental analysis possible.  相似文献   

3.
Summary System-compatibility and universality of the retention prediction concept has been investigated for polycyclic aromatic hydrocarbons in reversed-phase liquid chromatography. The results clearly indicate that the retention prediction approach has a very high potential for optimization of separation conditions in almost all reversed-phase systems, and allows more precise and rapid analysis. This approach may be one of the best optimization techniques, because the system does not require any standard materials.  相似文献   

4.
Summary High performace liquid chromatography (HPLC) was used to separate the large polycyclic aromatic hydrocarbons in a diesel particulate extract. Identification of individual peaks was made using a photodiode array UV/visible detector to collect their absorbance spectra. Comparisons between standard compounds and the peaks were made using both retention times and spectra. Compounds of up to 10 rings were identified.  相似文献   

5.
A reversed-phase high performance liquid chromatographic method for the successful separation and determination of 13 synthetic food colorants (Tartrazine E 102, Quinoline Yellow E 104, Sunset Yellow E 110, Carmoisine E 122, Amaranth E 123, Ponceau 4R E 124, Erythrosine E 127, Red 2G E 128, Allura Red AC E 129, Patent Blue V E 131, Indigo Carmine E 132, Brilliant Blue FCF E 133 and Green S E 142) was developed. A C18 stationary phase was used and the mobile phase contained an acetonitrile-methanol (20:80 v/v) mixture and a 1% (m/v) ammonium acetate buffer solution at pH 7.5. Successful separation was obtained for all the compounds using an optimized gradient elution within 29 min. The diode-array detector was used to monitor the colorants between 350 and 800 nm. The method was thoroughly validated. Detection limits for all substances varied between 1.59 (E 142) and 22.1 (E 124) μg L−1. The intra-day precision (as R.S.D.r) ranged from 0.37% (E 122 in fruit flavored drink at a concentration of 100 mg L−1) to 4.8% (E 142 in icing sugar at a level of 0.9 mg kg−1). The inter-day precision (as R.S.D.R) was between 0.86% for E 122 in fruit flavored drink at 100 mg L−1 and 10% for E142 in jam at a concentration of 9 mg kg−1. Satisfactory recoveries, ranging from 94% (E 142 in jam) to 102% (E 131 in sweets), were obtained. The method was applied to the determination of colorants in various water-soluble foods, such as fruit flavoured drinks, alcoholic drinks, jams, sugar confectionery and sweets, with simple pre-treatment (dilution or water extraction).  相似文献   

6.
Summary Gradient elution of polystyrene standards on reversed phase C18 columns by methanol/tetrahydrofuran or methanol/dichloromethane mixtures yielded a strange effect of the molecular weight of the sample on the specific peak are (mAUs per g sample injected). The effect did not occur when pure dichloromethane was used as an eluent. Further to this, dependence of specific peak area on flow rate was observed in gradient elution with methanol/tetrahydrofuran mixtures. It was found that these effects were due to polymer elution at the verge of precipitation. Depending on the dwell time of the sample in the column, opalescence occurred that added to the UV signal used for monitoring the elution.  相似文献   

7.
An indirect UV photometric detection technique is described in which a low concentration of a UV-absorbing compound (UVAC) is added to the mobile phase in reversed phase liquid chromatography, thereby making it possible for non UV-absorbing compounds such as the lower alcohols to be detected by the UV detector. This happens because the injected analyte may extract a portion of the UV absorbing compound from the mobile and/or stationary phase and the complex is co-eluted as a positive peak at the retention time of the analyte. Alternatively, the injected analyte may appear as a negative peak if the UV-absorbing compound is transferred to the mobile and stationary phases. In any case, the injected compound appears either as a positive or negative peak depending on the relative polarities and concentrations of all the compounds in the system. In addition, the resulting excess or deficiency of detection agent in the stationary phase is eluted separately as a positive or negative peak, indicating that the system has returned to equilibrium. In the work described herein, the chromatographic conditions and variables of the indirect photometric technique were studied to develop a quantitative HPLC method for UV-transparent compounds. It was found that under optimal conditions it is possible to determine some analytes quantitatively at concentrations as low as 0.05%.  相似文献   

8.
Liquid chromatography coupled to mass spectrometry with atmospheric pressure chemical ionization was used for the determination of polycyclic aromatic hydrocarbon derivatives, the oxygenated polycyclic aromatic hydrocarbons and nitrated polycyclic aromatic hydrocarbons, formed in asphalt fractions. Two different methods have been developed for the determination of five oxygenated and seven nitrated polycyclic aromatic hydrocarbons that are characterized by having two or more condensed aromatic rings and present mutagenic and carcinogenic properties. The parameters of the atmospheric pressure chemical ionization interface were optimized to obtain the highest possible sensitivity for all compounds. The detection limits of the methods ranged from 0.1 to 57.3 μg/L for nitrated and from 0.1 to 6.6 μg/L for oxygenated derivatives. The limits of quantification were in the range of 4.6–191 μg/L for nitrated and 0.3–8.9 μg/L for oxygenated derivatives. The methods were validated against a diesel particulate extract standard reference material (National Institute of Standards and Technology SRM 1975), and the obtained concentrations (two nitrated derivatives) agreed with the certified values. The methods were applied in the analysis of asphalt samples after their fractionation into asphaltenes and maltenes, according to American Society for Testing and Material D4124, where the maltenic fraction was further separated into its basic, acidic, and neutral parts following the method of Green. Only two nitrated derivatives were found in the asphalt sample, quinoline and 2‐nitrofluorene, with concentrations of 9.26 and 2146 mg/kg, respectively, whereas no oxygenated derivatives were detected.  相似文献   

9.
In the present work, an analytical method for determination of risedronate, a member of bisphosphonates, is described for the routine analysis in rat plasma. Sample pre-treatment involves protein precipitation, co-precipitation with calcium at alkaline pH, hydrolysis of possible derivatives of pyrophosphate and reprecipitation. A good separation was obtained by using a reversed-phase column (Hypersil ODS-2 C18, 4.6 mm × 250 mm, 5 μm). The mobile phase was an aqueous solution of buffer (contained 1.5 mM EDTA-2Na, 1 mM sodium etidronate, 11 mM sodium phosphate and 5 mM tetrabutylammonium bromide as ion-pair reagent) - methanol (88:12, v/v) adjusted to pH 6.75 using 1 M NaOH. The flow rate was 1 ml min−1. UV detection (λ = 262 nm) was used to quantitate risedronate in the concentration range of 10-500 ng ml−1. The limit of detection and quantitation for risedronate were 7 and 10 ng ml−1, respectively. The method was applied successfully to plasma samples from Wistar rats undergoing oral administration of risedronate mini-pills. Precision, extraction recoveries, as well as accuracy results, were satisfactory and no interference was found at the retention time of risedronate. Hence, the method is suitable for monitoring risedronate in rat plasma.  相似文献   

10.
A method has been developed for the trace analysis of polycyclic aromatic hydrocarbons, which are known as persistent organic pollutants and ubiquitous constituents of fine particulate matter that causes growing airborne pollution. The method, which was especially for samples of airborne particulate matter less than 2.5 μm in diameter, utilized accelerated solvent extraction and ultra high performance liquid chromatography with fluorescence detector. Four principal parameters of accelerated solvent extraction were optimized to obtain maximum extraction efficiency. Using the established synergetic programs of gradient elution and fluorescence wavelength switching, a rapid separation was achieved in 6.56 min with good linearity for 15 polycyclic aromatic hydrocarbons (coefficient of determination above 0.999). The limits of detection ranged from 0.833 to 10.0 pg/m3. The precision of the method expressed as inter‐day relative standard deviation ranged from 0.2 to 1%, which was calculated from nine repetitive measurements of 8.00 μg/L analytes. Average spiked recoveries ranged from 71.6 to 97.7%, with the exception of naphthalene. The rapid, sensitive, and accurate method can meet the pressing needs of health risk assessment and increasingly heavy daily tasks of air quality monitoring.  相似文献   

11.
使用亲水性的C16硅胶反相色谱柱分离了苯胺、间甲苯胺、4-氯苯胺、2,4-二氯苯胺、3,4-二氯苯胺、2,4,6-三氯苯胺、对溴苯胺、2-萘胺及N-硝基-2-萘胺等9种芳香胺类化合物,对影响分离的几种主要条件进行了优化。结果表明以乙腈-水为流动相,使用梯度淋洗程序,这9种芳香胺类化合物可以在大约40min内得到理想分离,分离后的芳香胺类化合物可在紫外检测器上进行检测。该方法对苯胺、间甲苯胺、4-氯苯胺、2,4-二氯苯胺、3,4-二氯苯胺、2,4,6-三氯苯胺、对溴苯胺、2-萘胺及N-硝基-2-萘胺的检出限分别为15、173、0、40、1.21、7、30、30、0.3μg/L。该方法可应用于环境水样中芳香胺类化合物的测定。  相似文献   

12.
建立了基于聚合物整体柱的固相萃取-高效液相色谱测定尿液中4种羟基多环芳烃(OH-PAHs)的分析方法。在注射器管中合成聚(甲基丙烯酸丁酯-乙二醇二甲基丙烯酸酯)整体柱(poly (BMA-co-EDMA)),并将其用于尿液中4种羟基多环芳烃的前处理,同时考察了上样浓度、淋洗液、洗脱液和洗脱体积对萃取效率的影响。结合高效液相色谱-荧光分析,4种羟基多环芳烃在各自的范围内线性关系良好(r≥0.9991);方法的检出限和定量限分别为0.06~0.09 ng/mL和0.20~0.30 ng/mL;日内(n=5)和日间(n=3)精密度分别为1.4%~5.3%和2.6%~7.3%。对焦炉工人尿液样品进行加标(3 ng/mL)回收试验,回收率为78.2%~117.0%。该固相萃取柱能够有效萃取和净化尿液中4种羟基多环芳烃,并且可以重复使用。该法简单、准确,可应用于尿液中羟基多环芳烃的分析。  相似文献   

13.
王美飞  杨丽莉  胡恩宇 《色谱》2017,35(6):669-673
建立了一种微波提取-高效液相色谱法测定大气颗粒物中多环芳烃的方法。吸附有颗粒物的超细玻璃纤维/石英纤维滤膜用正己烷/丙酮(1∶1,v/v)混合溶剂经微波提取,提取液用弗罗里硅土柱净化,经浓缩定容后,采用液相色谱法-二极管阵列(PDA)-荧光双检测器测定。目标化合物在20.0~500μg/L范围内线性良好,相关系数不小于0.996 0。空白膜加标结果显示,目标化合物的回收率在56.3%~101%之间。该法已运用于南京市大气颗粒物中多环芳烃分布的调查研究。  相似文献   

14.
A. Mandl  W. Lindner 《Chromatographia》1996,43(5-6):327-330
Summary An improved, reversed-phase, high-performance liquid chromatography (HPLC) method with dual UV-fluorescence detection for simultaneous determination of the antifolate methotrexate, the folate leucovorin and their two main metabolites 7-hydroxymethotrexate and 5-methyltetrahydrofolate, respectively is presented. The fluorescence intensity of leucovorin could be significantly increased by on-line, post-column irradiation with UV at 254 nm thus lowering the limit of detection for leucovorin to 0.2 ng absolute at a signal-to-noise ratio 31.  相似文献   

15.
王超  黄肇章  邢占磊  陈烨  于建钊  刘方  袁懋 《色谱》2019,37(2):239-245
建立了在线固相萃取-液相色谱直接测定水体中16种超痕量多环芳烃(PAHs)的方法。水样经高速离心后,加入适量甲醇,配制成40%(体积分数)甲醇水溶液,直接进样2 mL至在线固相萃取流路,进行萃取富集,再通过阀切换将洗脱的PAHs转移至分析流路进行分离检测。16种PAHs在各自范围内线性关系良好,相关系数均大于0.996;方法的检出限为0.14~12.50 ng/L,其中苯并[a]芘(B(a)P)的检出限为0.38 ng/L。实际水样在10、40和200 ng/L加标水平下的加标回收率为76.1%~134.9%,RSD为0.3%~16.6%。B(a)P在1 ng/L加标水平下的回收率为71.8%~92.7%,RSD为3.9%。结果表明,该方法操作简单,灵敏度高,溶剂消耗量少,可满足水样中PAHs,尤其是B(a)P的超痕量分析要求。  相似文献   

16.
Summary In this paper, the amount of iodine anion in dried kelp and iodized throat tablets was determined by reversed-phase ion-pair chromatography. A 300×4 mm I.D. columns packed with -Bondapak-C18 (5 m) was used and distilled water containing 10 mmol/l trimethylphenyl ammonium bromide was used as the eluent. UV detection at 231 nm was selected to monitor the iodine anion.  相似文献   

17.
王艳洁  那广水  王震  姚子伟 《色谱》2012,30(8):847-850
通过考察提取溶剂、毛细管柱、净化条件及共溶出干扰物等因素对十氯酮测定的影响,建立了二氯甲烷液-液富集萃取、硫酸净化分离、气相色谱法(GC)-电子捕获检测器(ECD)测定海水介质中有机氯农药类持久性有机污染物十氯酮残留分析方法。1 L海水经50 mL二氯甲烷萃取富集,浓缩后采用硫酸净化,以1%(体积分数)甲醇/正己烷混合溶液转移定容后,采用DB-5非极性毛细管柱进行GC分离,电子捕获检测器可测定其中十氯酮的含量;该方法采用外标法定量,在5~100 μg/L范围内呈线性,线性相关系数为0.9989。低、中、高3个浓度水平的平均加标回收率为81%~108%,相对标准偏差为1.2%~5.1%(n=6)。方法的检出限为0.6 ng/L。结果表明,该方法灵敏度高,线性关系好,可以满足简便、快速、准确测定海水中十氯酮的要求。  相似文献   

18.
Ion chromatography (IC) is a well-known technique for trace determination of inorganic ions and small organic acids. Recently, it has also appeared as a promising alternative to reverse phase chromatography for the determination of polar pesticides and pharmaceutical drugs in various sample matrices. Therefore, this study aims to provide a comprehensive overview of the application of IC coupled to fluorescence (FLD) or UV detector for the determination of pesticides and pharmaceutical drugs in samples from all walks of life. Apart from advantages and limitations, a short comparison of IC-FLD/UV with other techniques especially reverse-phase chromatography was drawn to envision future research efforts in this direction. Finally, several related areas such as IC hyphenation with different detectors (spectroscopic and spectrometer), miniaturization, automation, green chemistry, mobile phase, column, sample preparation, etc., were discussed to highlight its application for the determination of a wide range of analytes in the complex sample matrix.  相似文献   

19.
刘志超  胡霞林  刘景富 《色谱》2010,28(5):513-516
以涂有聚二甲基硅氧烷(PDMS)的石英光导纤维作为固相微萃取纤维,建立了一次性固相微萃取与高效液相色谱联用测定环境水样中的菲、荧蒽和屈3种多环芳烃(PAHs)的方法。实验考察了解吸时间、萃取时间、搅拌速度、盐效应以及样品溶液pH值对萃取效率的影响,优化得到的萃取和解吸条件为: 于60 mL样品溶液中放入两段萃取纤维(1.5 cm)和1.2 g氯化钠,在1200 r/min搅拌速度下萃取60 min,取出萃取纤维并转入120 μL甲醇中密封静置解吸24 h后,取20 μL解吸液进行液相色谱测定。该方法对于菲、荧蒽和屈的检出限分别为0.17、0.17和0.08 μg/L;精密度(以测定0.5 μg/L PAHs标准溶液6次的相对标准偏差计)小于8%;实际样品中3种PAHs的加标回收率为80.0%~107%。该方法快速简便,纤维一次性使用,克服了污染物在纤维上残留的问题。  相似文献   

20.
Gu W  Zhang J  Xin M  Yao Y  Ji R  Lü B  Chen J 《色谱》2011,29(10):1041-1045
建立了反相高效液相色谱(RP-HPLC)分离检测用不同方法煮制的猪肉及其汤汁中17种游离氨基酸的方法.样品经6-氨基喹啉基-N-羟基琥珀酰亚氨基甲酸酯(AQC)柱前衍生后,采用Nova- PakTMC18色谱柱分离,以AccQ·Tag Eluent A稀释液、乙腈和超纯水为流动相,梯度洗脱,检测波长为248 nm,在4...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏