共查询到20条相似文献,搜索用时 15 毫秒
1.
In this study, the suitability of solid‐phase extraction (SPE) coupled in‐line to CE with UV–Vis detection was evaluated for the preconcentration and separation of diluted solutions of five pharmaceuticals compounds: benzafibrate, piroxicam, diclofenac sodium, naproxen and clofibric acid. An SPE analyte concentrator containing Oasis® HLB sorbent was constructed without frits and placed near the inlet end of the separation capillary. Different parameters such as sample pH, composition and volume of the elution plug and sample loading time were studied in order to obtain the maximum preconcentration factors. The LODs reached for standard samples were in the range 0.06–0.5 ng/mL with good reproducibility, and the developed strategy provides sensitivity enhancement factors around 14 000‐fold in peak area and 5900‐fold in peak height compared with the normal hydrodynamic injection. Finally, river water samples fortified with the pharmaceutical compounds were analyzed by the developed in‐line SPE‐CE‐UV method in order to show the potential of the methodology for the analysis of environmental aquatic samples. For these samples, high values of relative recoveries, between 73–107% and 79–103% for two concentration levels, 5 and 25 ng/mL, respectively, were obtained and LODs ranged between 0.19 and 1 ng/mL. 相似文献
2.
Albert Prez‐Alcaraz Francesc Borrull Carme Aguilar Marta Calull 《Electrophoresis》2019,40(14):1762-1770
This work presents a strategy based on the in‐line coupling of SPE and CE for the chiral determination of cathinones (R,S‐mephedrone, R,S‐4‐methylephedrine, and R,S‐ methylenedioxypyrovalerone) in urine samples, using a sample pretreatment based on liquid‐liquid extraction. The chiral separation of the compounds is achieved by adding a mixture of 8 mM 2‐hydroxypropil β‐CD and 5 mM β‐CD to the BGE, which consists of 70 mM of monosodium phosphate aqueous solution at pH 2.5. Oasis HLB was the selected sorbent for the in‐line SPE device, and to reduce analysis time and LODs, several parameters affecting the in‐line SPE system were evaluated, such as pressure and time of sample injection and dimensions of the SPE device. The highest preconcentration factors were achieved by using 3 bar of injection pressure for 20 min with an in‐line SPE device of 2 mm length and 150 µm of i.d. The developed method was applied to determine the presence of the compounds in spiked urine samples. The LODs obtained were between 3 and 8 ng/mL, and these levels were below the usual concentrations at which these drugs are present in urine from cathinone abusers. Thus, the optimized method has the potential to be applied for toxicological and forensic purposes. 相似文献
3.
A poly(4‐vinylpridine‐co‐ethylene glycol dimethacrylate) monolith was synthesized in a capillary and constructed as a concentrator for the in‐line polymeric monolith microextraction coupling with capillary electrophoresis. The integrated system was then used for the simultaneous determination of five trace phenols (2‐nitrophenol, 3‐nitrophenol, 4‐nitrophenol, 2‐chlorophenol, and 2,4‐dichlorophenol) in water samples. The experimental parameters for in‐line solid‐phase extraction, such as composition and volume of the elution plug, pH of sample solution, and the time for sample loading were optimized. The sensitivity for the mixture of phenols (2‐nitrophenol, 3‐nitrophenol, 4‐nitrophenol, 2‐chlorophenol, and 2,4‐dichlorophenol) enhanced to 615–2222 folds at the optimum condition was compared to the sensitivity for a normal hydrodynamic injection in capillary electrophoresis. Linearity ranged from concentration of 10–500 ng mL?1(R2 > 0.999) for all five phenols with the detection limits of 1.3–3.3 ng mL?1. In tap, snow and Yangtze River water spiked with 20 ng mL?1 and 200 ng mL?1, respectively, the recoveries of 84–105% were obtained. It has been demonstrated that this work has great potential for the analysis of phenols in genuine water samples. 相似文献
4.
《Journal of separation science》2018,41(11):2401-2410
A method based on membrane‐protected micro‐solid‐phase extraction coupled with gas chromatography and mass spectrometry was developed for the determination of six ultraviolet filter compounds in various aqueous media. Multiwalled carbon nanotubes as the sorbent were encapsulated in a sealed polypropylene membrane packet and immersed in the sample to extract the analytes, and then dichloromethane was used for desorption purpose. The method was sensitive enough for quantitative analysis of the target analytes, with limits of quantification between 0.01 and 0.06 μg/L, and produced a linear response (R2 > 0.991) over the calibration range (0.05–6 μg/L). The obtained reproducibility was practically suitable with relative standard deviation values of less than 14% in pure water (spiked at 0.20/μg L) and less than 15% in real samples. The optimized method was applied for the analysis of real water samples with varying matrix complexity: tap, river, and dam water; geothermal spa; and sewage treatment plant effluent. Various levels and patterns of contamination were observed in the examined samples, while the sample from spa was the most contaminated, regarding the target analytes. Matrix spikes and matrix spike replicates were also analyzed to validate the technique for analysis of real aqueous samples, and satisfactory results were achieved. 相似文献
5.
Asimina Voulgari Vasiliki A. Gatselou Foteini A. Kappi Tatiana G. Choleva George Z. Tsogas Athanasios G. Vlessidis 《International journal of environmental analytical chemistry》2017,97(12):1163-1177
This work describes the development of a new green solid-phase extraction approach, which is based on the use of low-cost extraction discs composed of plain filter papers that are covered with a synthetic wax-like coating. The filter papers are printed in a commercial solid ink printer, which dispenses a synthetic wax-like ink on the surface of the paper, to cover the hydrophilic cellulose fibre matrix with an interface of lipophilic domains where non-polar analytes can partition through hydrophobic interactions. The modified paper filters were used to extract hydrophobic organic compounds from water samples following the customary procedure of solid-phase extraction without sorbent preconditioning and needless of high-vacuum sources. As a proof-of-concept application, a series of non-polar organic UV filters were used as model analytes to optimise the extraction parameters and evaluate the performance of the method in spiked water samples. Based on this principle, a new sample preparation platform with low environmental footprint has been developed that enables extraction to be carried out using low-cost, environmental benign and non-toxic conventional materials. The advantages and disadvantages of the method, alongside with its future prospects towards the development of custom-made ‘printed extraction kits’, are envisioned and discussed. 相似文献
6.
Leila Kharbouche María Dolores Gil García Ana Lozano Hadj Hamaizi María Martínez Galera 《Journal of separation science》2020,43(11):2142-2153
A silica‐based MCM‐41 mesoporous material functionalized with cyanopropyl groups has been synthesized by cocondensation, characterized and applied to preconcentrate six parabens and three UV filters in river and swimming‐pool waters. The analytes were quantified by ultra‐high performance liquid chromatography‐tandem mass spectrometry, according to the Directive 96/23/EC. Even though matrix effect was negligible, quantification in river water samples with the standard addition approach improved the recoveries obtained using solvent‐based and even with matrix‐matched calibration. The method quantification limits in river water samples were 0.05 ng/mL for 2,4‐dihydroxybenzophenone and 0.01 ng/mL for the rest. Recoveries, evaluated for a concentration level of 0.5 ng/L, were in the range 93.5‐107.6% for parabens and in the range 64.2‐85.8% for UV filters, with relative standard deviations intraday ≤10.2 and 10.8%, respectively. This parameter, evaluated for a concentration level of 0.1 ng/L, ranged between 98.3 and 110.4% for parabens and between 61.9 and 89.9% for UV filters, with relative standard deviation intraday ≤15.3 and 15.5%, respectively. The two UV filters with lower recoveries were the most affected by the addition of sodium chloride. River and swimming pool waters were analyzed and all the personal care products were found in the swimming pool water, whereas only methylparaben was detected in the river water. 相似文献
7.
Eunice Mayumi Suenaga Demian R. Ifa Alessandro Carvalho Cruz Renata Pereira Jr. Eduardo Abib Mineko Tominga Clovis Ryuichi Nakaie 《Journal of separation science》2009,32(4):637-643
A new automated SPE‐LC‐ESI‐MS/MS method was developed and validated to quantify venlafaxine in human plasma using fluoxetine as an internal standard. The analytes were automatically extracted from plasma by C18 SPE cartridges, separated on a C8 RP column and analyzed by MS in the multiple reaction‐monitoring (MRM) mode. The method has a chromatographic run time of 4.0 min and a linear calibration curve over the range of 0.25–200 ng/mL (r >0.997). The between‐run precisions, based on the percent RSD for replicate quality controls (0.75; 80, and 200 ng/mL), were < 8.5% for all concentrations. The between‐run accuracies, based on the percent relative error, were < 4.0%. This method was successfully employed in a bioequivalence study of two venlafaxine capsule formulations (test formulation from Eurofarma (Brazil) and Efexor XR, reference formulation, from Wyeth‐Whitehall, Brazil) in 48 healthy volunteers of both sexes who received a single 150 mg dose of each formulation. More than 3000 samples were analyzed eliminating the analyst's exposure to hazardous organic solvents normally employed in off‐line liquid–liquid extractions. The 90% confidence interval (CI) of the individual ratio geometric mean for Test/Reference was 91.6–103.4% for AUC0–48 h and 102.2–112.6% for Cmax. Since both 90% CI for AUC0–48 h and Cmax were included in the 80–125% interval proposed by the US Food and Drug Administration (FDA) and the Brazilian National Health Surveillance Agency (ANVISA), the test formulation was considered bioequivalent to Efexor XR according to both the rate and extent of absorption. 相似文献
8.
Multiresidue determination of UV filters in water samples by solid‐phase extraction and liquid chromatography with tandem mass spectrometry analysis 下载免费PDF全文
Anna Laura Capriotti Chiara Cavaliere Susy Piovesana Roberto Samperi Serena Stampachiacchiere Salvatore Ventura Aldo Laganà 《Journal of separation science》2014,37(20):2882-2891
UV filters, contained in sunscreens and other cosmetic products, as well as in some plastics and industrial products, are nowadays considered contaminants of emerging concern because their widespread and increasing use has lead to their presence in the environment. Furthermore, some UV filters are suspected to have endocrine disruption activity. In the present work, we developed an analytical method based on liquid chromatography with tandem mass spectrometry for the determination of UV filters in tap and lake waters. Sixteen UV filters were extracted from water samples by solid‐phase extraction employing graphitized carbon black as adsorbent material. Handling 200 mL of water sample, satisfactory recoveries were obtained for almost all the analytes. The limits of detection and quantification of the method were comparable to those reported in other works, and ranged between 0.7–3.5 and 1.9–11.8 ng/L, respectively; however in our case the number of investigated compounds was larger. The major encountered problem in method development was to identify the background contamination sources and reduce their contribution. UV filters were not detected in tap water samples, whereas the analyses conducted on samples collected from three different lakes showed that the swimming areas are most subject to UV filter contamination. 相似文献
9.
In‐line coupled single drop liquid–liquid–liquid microextraction with capillary electrophoresis for determining fluoroquinolones in water samples 下载免费PDF全文
A simple in‐line single drop liquid–liquid–liquid microextraction (SD‐LLLME) coupled with CE for the determination of two fluoroquinolones was developed. The method is capable to quantify trace amount of analytes in water samples and to improve the sensitivity of CE detection. For the SD‐LLLME, a thin layer of organic phase was used to separate a drop of 0.1 M NaOH hanging at the inlet of the capillary from the aqueous donor phase. By this way, the analytes were extracted to the acceptor phase through the organic layer based on their acidic/basic dissociation equilibrium. The drop was immersed into the organic phase during 10 min for extraction and then it is directly injected into the capillary for the analysis. Parameters such as type and volume of organic solvent phase, aqueous donor, and acceptor phases and extraction time and temperature were optimized. The enrichment factor was calculated, resulting 40‐fold for enrofloxacin (ENR) and sixfold for ciprofloxacin (CIP). The linear range were 20–400 μg/L for ENR and 60–400 μg/L for CIP. The detection limits were 10.1 μg/L and 55.3 μg/L for ENR and CIP, respectively, and a good reproducibility was obtained (4.4% for ENR and 5.6% for CIP). Two real water samples were analysed applying the new method and the obtained results presented satisfactory recovery percentages (90–100.3%). 相似文献
10.
Although there is increasing concern about residues from personal care products entering the aquatic environment and their
potential to accumulate to levels that pose a health threat to humans and wildlife, we still know little about the extent
and magnitude of their presence in the aquatic environment. In this study we describe a procedure for isolation, and subsequent
determination, of compounds commonly added to personal care products. The compounds of interest include UV filters with the
commercial name Eusolex (homosalate, 4-methylbenzylidenecamphor, benzophenone-3, octocrylene, butylmethoxydibenzoylmethane,
ethylhexyl methoxycinnamate) and two common anti-microbial agents, clorophene and triclosan. Water samples were filtered,
acidified, and extracted by use of solid-phase extraction. Extracted compounds were then derivatised before analysis by gas
chromatography–mass spectroscopy. By use of our method we obtained limits of detection of 13–266 ng L−1 for UV filters, and 10–186 ng L−1 for triclosan and clorophene. Recoveries were 82–98% for deionised water and 50–98% for natural water (seawater, pool water,
lake water, and river water). Samples collected in Slovenia included seventeen recreational waters (seawater, pool water,
lake water, and river water; August 2004) and four wastewaters (January 2005). The most abundant UV filter was benzophenone-3
(11–400 ng L−1). Of the two anti-microbial agents studied, trace amounts, only, of triclosan were present in the river Kolpa (68 ng L−1) and in an hospital effluent (122 ng L−1). 相似文献
11.
《Journal of separation science》2018,41(8):1856-1863
In‐syringe solid‐phase extraction is a promising sample pretreatment method for the on‐site sampling of water samples because of its outstanding advantages of portability, simple operation, short extraction time, and low cost. In this work, a novel in‐syringe solid‐phase extraction device using metal–organic frameworks as the adsorbent was fabricated for the on‐site sampling of polycyclic aromatic hydrocarbons from environmental waters. Trace polycyclic aromatic hydrocarbons were effectively extracted through the self‐made device followed by gas chromatography with mass spectrometry analysis. Owing to the excellent adsorption performance of metal–organic frameworks, the analytes could be completely adsorbed during one adsorption cycle, thus effectively shortening the extraction time. Moreover, the adsorbed analytes could remain stable on the device for at least 7 days, revealing the potential of the self‐made device for on‐site sampling of degradable compounds in remote regions. The limit of detection ranged from 0.20 to 1.9 ng/L under the optimum conditions. Satisfactory recoveries varying from 84.4 to 104.5% and relative standard deviations below 9.7% were obtained in real samples analysis. The results of this study promote the application of metal–organic frameworks in sample preparation and demonstrate the great potential of in‐syringe solid‐phase extraction for the on‐site sampling of trace contaminants in environmental waters. 相似文献
12.
《Journal of separation science》2018,41(17):3449-3458
Four different miniaturized methodologies were developed and applied to the analysis of 11 UV filters in sand samples. These approaches were based on ultrasound and vortex extractions, on‐column lixiviation, and ultrasound extraction followed by solid‐phase microextraction. Gas chromatography with tandem mass spectrometry was used for quantitative analysis. The analytical performance provided by the four methods was evaluated in terms of linearity, accuracy, precision, and limits of quantification. Lixiviation was discarded since it provided the lowest recoveries and the highest limits of quantification. In contrast, ultrasound and vortex extractions, and ultrasound extraction followed by solid‐phase microextraction were suitable, with recoveries in general >85% and limits of quantification at the low ng/g level. Moreover, ultrasound extraction followed by solid‐phase microextraction allowed using external calibration with aqueous standards and it provided higher sensitivity, with limits of quantification in general one order of magnitude lower than those achieved with the other techniques. The methodologies were applied for the analysis of four marine sand samples, and the results were statistically compared performing an analysis of variance. Eight out of the eleven target UV filters were detected. Octocrylene was found at very high concentrations (up to 1000 ng/g) followed by ethylhexyl salicylate, 4‐methylbenzylidene camphor, homosalate, and 2‐ethylhexyl methoxycinnamate. 相似文献
13.
Michael Biacchi Ricky Bhajun Nassur Saïd Alain Beck Yannis Nicolas François Emmanuelle Leize‐Wagner 《Electrophoresis》2014,35(20):2986-2995
mAbs are highly complex proteins that present a wide range of microheterogeneity that requires multiple analytical methods for full structure assessment and quality control. As a consequence, the characterization of mAbs on different levels is particularly product‐ and time‐consuming. CE‐MS couplings, especially to MALDI, appear really attractive methods for the characterization of biological samples. In this work, we report the last instrumental development and performance of the first totally automated off‐line CE‐UV/MALDI‐MS/MS. This interface is based on the removal of the original UV cell of the CE apparatus, modification of the spotting device geometry, and creation of an integrated delivery matrix system. The performance of the method was evaluated with separation of five intact proteins and a tryptic digest mixture of nine proteins. Intact protein application shows the acquisition of electropherograms with high resolution and high repeatability. In the peptide mapping approach, a total number of 154 unique identified peptides were characterized using MS/MS spectra corresponding to average sequence coverage of 64.1%. Comparison with NanoLC/MALDI‐MS/MS showed complementarity at the peptide level with an increase of 42% when using CE/MALDI‐MS coupling. Finally, this work represents the first analysis of intact mAb charge variants by CZE using an MS detection. Moreover, using a peptide mapping approach CE‐UV/MALDI‐MS/MS fragmentation allowed 100% sequence coverage of the light chain and 92% of the heavy chain, and the separation of four major glycosylated peptides and their structural characterization. 相似文献
14.
Ludmila Mut Thomas Grobosch Torsten Binscheck‐Domaß Wolfgang Frenzel 《Biomedical chromatography : BMC》2016,30(3):343-362
A multi‐analyte screening method for the quantification of 50 acidic/neutral drugs in human plasma based on on‐line solid‐phase extraction (SPE)–HPLC with photodiode array detection (DAD) was developed, validated and applied for clinical investigation. Acetone and methanol for protein precipitation, three different SPE materials (two electro‐neutral, one strong anion‐exchange, one weak cation‐exchange) for on‐line extraction, five HPLC‐columns [one C18 (GeminiNX), two phenyl‐hexyl (Gemini C6‐Phenyl, Kinetex Phenyl‐Hexyl) and two pentafluorophenyl (LunaPFP(2), KinetexPFP)] for analytical separation were tested. For sample pre‐treatment, acetone in the ratio 1:2 (plasma:acetone) showed a better baseline and fewer matrix peaks in the chromatogram than methanol. Only the strong anion‐exchanger SPE cartridge (StrataX‐A, pH 6) allowed the extraction of salicylic acid. Analytical separation was carried out on a Gemini C6‐Phenyl column (150 × 4.6 mm, 3 µm) using gradient elution with acetonitrile–water 90:10 (v/v) and phosphate buffer (pH 2.3). Linear calibration curves with correlation coefficients r ≥ 0.9950/0.9910 were obtained for 46/four analytes. Additionally, this method allows the quantification of 23 analytes for therapeutic drug monitoring. Limits of quantitation ranged from 0.1 (amobarbital) to 23 mg/L (salicylic acid). Inter‐/intra‐day precisions of quality control samples (low/high) were better than 13% and accuracy (bias) ranged from ?14 to 10%. A computer‐assisted database was created for automated detection of 223 analytes of toxicological interests. Four cases of multi‐drug intoxications are presented. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
15.
Single‐drop microextraction combined in‐line with capillary electrophoresis for the determination of nonsteroidal anti‐inflammatory drugs in urine samples 下载免费PDF全文
Alejandro García‐Vázquez Francesc Borrull Marta Calull Carme Aguilar 《Electrophoresis》2016,37(2):274-281
This study describes a method to determine nonsteroidal anti‐inflammatory drugs (NSAIDs) in urine samples based on the use of single‐drop microextraction (SDME) in a three‐phase design as a preconcentration technique coupled in‐line to capillary electrophoresis. Different parameters affecting the extraction efficiency of the SDME process were evaluated (e.g. type of extractant, volume of the microdroplet, and extraction time). The developed method was successfully applied to the analysis of human urine samples with LODs ranging between 1.0 and 2.5 μg/mL for all of the NSAIDs under study. This method shows RSD values ranging from 8.5 to 15.3% in interday analysis. The enrichment factors were calculated, resulting 27‐fold for ketoprofen, 14‐fold for diclofenac, 12‐fold for ibuprofen, and 44‐fold naproxen. Samples were analyzed applying the SDME–CE method and the obtained results presented satisfactory recovery values (82–115%). The overall method can be considered a promising approach for the analysis of NSAIDs in urine samples after minimal sample pretreatment. 相似文献
16.
A method for the extraction and determination of methylmercury (MeHg) in solid matrices is presented. Combining the advantages of two extraction techniques—subcritical water extraction (subWE) and solid‐phase microextraction (SPME)—selective separation of MeHg from soils is possible. The procedure is based on extraction with subcritical water without using organic solvents, followed by in situ aqueous‐phase derivatization with sodium tetraethylborate and headspace SPME with a silica fiber coated with poly(dimethylsiloxane). The optimization of the extraction parameters is described. The identification and quantification of the extracted alkylmercury compounds from spiked soil samples is performed by GC–MS after thermal desorption. Copyright © 2000 John Wiley & Sons, Ltd. 相似文献
17.
CE is a high‐resolution separation technique broadly used in the biotechnology industry for carbohydrate analysis. The standard sample preparation protocol for CE analysis of glycans released from glycoproteins generally requires derivatization times of overnight at 37°C, using ≥100 fold excess of fluorophore reagent, 8‐aminopyrene‐1,3,6‐trisulfonic‐acid, if the sample is unknown, or it is a regulated biotherapeutic product, possibly containing terminal sialic acid(s). In this paper, we report on significant improvements for the standard CE sample preparation method of glycan analysis. By replacing the conventionally used acetic acid catalyst with citric acid, as low as 1:10 glycan to fluorophore molar ratio (versus the typical 1:≥100 ratio) maintained the >95% derivatization yield at 55°C with only 50 min reaction time. Terminal sialic acid loss was negligible at 55°C during the derivatization process, and indicating that the kinetics of labeling at 55°C was faster than the loss of sialic acid from the glycan. The reduced relative level of 8‐aminopyrene‐1,3,6‐trisulfonic‐acid simplified the removal of excess reagent, important in both CE‐LIF (electrokinetic injection bias) and CE‐MS (ion suppression). Coupling CE‐ ESI‐MS confirmed that the individual peaks separated by CE corresponded to single glycans and increased the confidence of structural assignment based on glucose unit values. 相似文献
18.
Paola Baile Juan Medina Lorena Vidal Antonio Canals 《Journal of separation science》2020,43(9-10):1808-1816
A novel approach is presented to determine four bisphenols in water and urine samples, employing magnetic dispersive solid‐phase extraction combined with liquid chromatography and diode array detection. A modified zeolite‐based magnetic composite was used as an efficient sorbent, combining the advantages of magnetic materials with the remarkable properties of zeolites. A multivariate optimization design was employed to optimize some experimental factors affecting magnetic dispersive solid‐phase extraction. The method was evaluated under optimized conditions (i.e., amount of sorbent, 50 mg; sample pH, unadjusted; NaCl concentration, 1.25%; extraction and elution time, 2 min; eluent solvent, ethanol; eluent solvent volume, 400 µL), obtaining good linearity with correlation coefficients ranging between 0.995 and 0.999 (N = 5) (from 2 to 250 µg/L for bisphenol A, bisphenol AP, and bisphenol P and from 5 to 250 µg/L for bisphenol AF). Method repeatability was assessed obtaining coefficients of variation between 3 and 11% (n = 6). Finally, the method was applied to spiked real samples, obtaining for water samples relative recoveries between 83 and 105%, and for urine samples between 81 and 108% for bisphenol A, bisphenol AP, and bisphenol AF, and between 47 and 59% for bisphenol P. 相似文献
19.
A simple sample pretreatment device was developed employing extractions across supported liquid membranes (SLMs) and in‐line coupling to a commercial CE instrument. The device consisted of two polypropylene conical units interspaced with a polypropylene planar SLM, which were impregnated with 1‐ethyl‐2‐nitrobenzene. The two units and the SLM were pressed against each other, donor unit was filled with 40 μL of an untreated body fluid and acceptor unit with 40 μL of DI water. The device was then placed into conventional CE vial fitted with a soft spring, which was depressed during injection into CE capillary and ensured that the SLM was not ruptured. Position of separation capillary injection end and high‐voltage electrode in the CE instrument was optimized in order to ensure efficient injection of pretreated body fluids. The device can be easily assembled/disassembled and SLMs can be replaced after each extraction thus minimizing sample carry‐over, avoiding tedious SLM regeneration, and reducing total pretreatment time and costs. The pretreatment device was examined by direct injection of human urine and serum spiked with nortriptyline, haloperidol, and loperamide. The basic drugs were diffusionaly transported across the SLM within 10 min and were injected into the separation capillary directly from the SLM surface in the acceptor unit, whereas matrix components were retained by the SLM. The in‐line SLM‐CE method showed good repeatability of peak areas (3.8–11.0%) and migration times (below 1.4%), linear relationship (r2 = 0.990–0.999), and low LODs (12–100 μg/L). 相似文献
20.
Francisco J. Lara Ana M. García-Campaña Christian Neusüss Fermín Alés-Barrero 《Journal of chromatography. A》2009,1216(15):3372-3379
An in-line solid-phase extraction-capillary electrophoresis method with UV–vis detection was developed for the monitoring of residues of five sulfonamides (sulfadoxin, sulfadimethoxine, sulfamerazine, sulfachloropyridazine and sulfamethoxazole) in tap, bottled mineral and river waters. For this purpose an analyte concentrator was constructed, based on the introduction of a small portion of a solid-phase extraction sorbent into the electrophoretic capillary to carry out an in-line concentration step, improving sensitivity. A detailed study was carried out to optimize parameters affecting the in-line solid-phase extraction process, such as the design of the concentrator device, type of sorbent and conditions of elution and injection. The proposed method is simple for the environmental monitoring of these antibiotic residues in waters, allowing the direct injection of the samples without any off-line pretreatment and achieving limits of detection between 0.3 and 0.6 μg/L. Recoveries ranging 52.2–109.2% and relative standard deviations below 13.4% were obtained. 相似文献