首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new strategy for trace analysis was proposed by preparing a molecularly imprinted polymer (MIP) sensor. The template molecules of clopyralid were determined based on “gate-controlled” electrochemiluminescence (ECL) measurement. A dense polymer film was electropolymerized on an electrode surface to fabricate the MIP–ECL sensor. The process of template elution and rebinding acted as a gate to control the flux of probes, which pass through the cavities and react on the electrode surface. ECL measurement was conducted in the luminol–H2O2 system. A linear relationship between ECL intensity and clopyralid concentrations in the range of 1?×?10?9 mol/L to 8?×?10?7 mol/L exists, and the detection limit was 3.7?×?10?10 mol/L. The prepared sensor was used to detect clopyralid in vegetables. Recoveries of 97.9 % to 102.9 % were obtained. The sensor showed highly selective recognition, high sensitivity, good stability, and reproducibility for clopyralid detection.  相似文献   

2.
IntroductionThelevelofglucoseinbloodorurineindicateshyper andhypoglycaemia ,bothofwhichcanresultfromavarietyofendocrinedisorders .1 4 Therapidandreliabledetermi nationofglucoselevelisaroutineprojectinclinicchem istry.Urinesamplesaresaferandmoreconvenientthanbloodones .Meanwhile ,theconcentrationofglucoseinserumiscloselyassociatedwiththatinurine .2 4 Eventhoughglucoseelectrodeshavebeensuccessfullyusedinseruminclinicalapplication ,thequestionstillremainedofhowtodetecttheglucoselevelinurine ,wh…  相似文献   

3.
Chuanyin Liu  Jiming Hu 《Electroanalysis》2008,20(10):1067-1072
Hemoglobin was entrapped in composite electrodeposited chitosan‐multiwall carbon nanotubes (MCNTs) film by assembling gold nanoparticles and hemoglobin step by step. In phosphate buffer solution (pH 7), a pair of well‐defined and quasireversible redox peaks appeared with formal potential at ?0.289 V and peak separation of 100 mV. The redox peaks respected for the direct electrochemistry of hemoglobin at the surface of chitosan‐MCNTs‐gold nanoparticles modified electrode. The parameters of experiments have also been optimized. The composite electrode showed excellent electrocatalysis to peroxide hydrogen and oxygen, the peak current was linearly proportional to H2O2 concentration in the range from 1×10?6 mol/L to 4.7×10?4 mol/L with a detection limit of 5.0×10?7 mol/L, and this biosensor exhibited high stability, good reproducibility and better selectivity. The biosensor showed a Michaelis–Menten kinetic response as H2O2 concentration is larger than 5.0×10?4 mol/L, the apparent Michaelis–Menten constant for hydrogen peroxide was calculated to be 1.61 μmol/L.  相似文献   

4.
Fabrication of multifunctional nanoplatform to in situ monitor Fenton reaction is of vital importance to probe the underlying reaction process and design high-performance catalyst.Herein,a hybrid catalyst comprising of single-crystalline Au nanoparticles(SC Au NPs) on reduced graphene oxide(RGO) sheet was prepared,which not only exhibited an excellent 1 O2 mediated Fenton-like catalytic activity in promoting rhodamine 6 G(R6 G) degradation by activating H2 O...  相似文献   

5.
A highly sensitive automated sequential‐injection chemiluminescence (SIA‐CL) method for determination of glucosamine sulphate (GLS) was developed. The goal of the present work is the evaluation of the enhancement effect of the investigated drug glucosamine sulphate on the chemiluminescence reaction between luminol and H2O2 in alkaline medium of 1.0 × 10?2 mol L?1 sodium hydroxide at pH 11. The experimental conditions affecting the CL reaction such as the sequence of the reagents, concentrations, flow rate and aspirated volumes of reactants were systematically investigated and optimized. Under optimum conditions 50 μL of 1.0 × 10?3 mol L?1 luminol, 30 μL of a GLS test solution and 50 μL of 1.0 × 10?2 mol L?1 H2O2 were used and the luminescing zone was pushed into the detector at a flow rate 100 μL s?1. The proposed method recorded high sensitivity, accuracy and simplicity that could be clarified as linear concentration range 1.0‐2000 ng mL?1 with rectilinear part (r = 0.9992, n = 9) and limit of detection 0.3 ng mL?1, along with relative standard deviation 1.3%. It was found that the developed method can be used directly to determine the investigated drug GLS in its pharmaceutical dosage forms and in spiked serum and urine by diluting the samples for a 1000 fold. The obtained results were statistically analyzed and compared with those obtained by the reported method.  相似文献   

6.
The cellulose acetate covered Prussian blue modified glassy carbon electrode (GCE/PB/CA) was fabricated as a novel hydrogen peroxide sensor. It was shown by scanning electron microscope (SEM) and atomic force microscope (AFM) that Prussian blue was covered and protected by cellulose acetate perfectly. The modified electrode showed a good electrocatalytic activity for H2O2 reduction in neutral aqueous solution. H2O2 was detected amperometrically in 0.05 mol/L phosphate buffer solutions (pH 7.0, containing 0.1 mol/L KCl as supporting electrolyte) at an applied potential of ?0.2 V (vs. SCE). The response current was proportional to the concentration of H2O2 in the range of 1.0×10?5 mol/L to 2.5×10?4 mol/L with the detection limit of 2.2×10?6 mol/L at a signal to noise ratio 3.  相似文献   

7.
This work proposes a novel biomimetic sensor for the potentiometric transduction of rivastigmine based on molecularly imprinted polymer (MIP). Using the Taguchi method, this study analyzed the optimum conditions for preparing the MIP‐based membranes. The rank order of each controllable factor was also determined. MIP‐based membranes exhibited a Nernstian response (30.7±1.1 mV decade?1) in a concentration range from 1.0×10?5 to 1.0×10?2 mol L?1 with a LOD of 6.3×10?6 mol L?1. The sensor was successfully applied to the determination of rivastigmine concentrations in human serum, plasma, urine, rat brain and tablets.  相似文献   

8.
We developed a novel iron‐tetrasulfophthalocyanine‐graphene‐Nafion (FeTSPc‐GR‐Nafion) modified screen‐printed electrode to determine hydrogen peroxide (H2O2) with high sensitivity and selectivity. The nanocomposite film (FeTSPc‐GR‐Nafion) exhibits an excellent electrocatalytic activity towards oxidation of H2O2 at a potential of +0.35 V in the absence of enzyme. A comparative study reveals that the FeTSPc‐GR complexes play a dual amplification role. Amperometric experiment indicates that the sensors possess good sensitivity and selectivity, with a linear range from 2.0×10?7 M to 5.0×10?3 M and a detection limit of 8.0×10?8 M. This sensor has been successfully used to develop the glucose biosensor and has also been applied to determine H2O2 in sterile water.  相似文献   

9.
A simple spectrophotometric assay of H2O2 and glucose using Ag nanoparticles has been carried out. Relying on the synergistic effect of H2O2 reduction and ultraviolet (UV) irradiation, Ag nanoparticles with enhanced absorption signals were synthesized. H2O2 served as a reducing agent in the Ag nanoparticles formation in which Ag+ was reduced to Ago by O2- generated via the decomposition of H2O2 in alkaline media. On the other hand, photoreduction of Ag+ to Ago under UV irradiations also contributed to the nanoparticles formation. The synthesized nanoparticles were characterized by TEM, XPS, and XRD. The proposed method could determine H2O2 with concentrations ranging from 5.0× 10^-7 to 6.0× 10^-5 tool/ L The detection limit was estimated to be 2.0 × 10^-7 mol/L. Since the conversion of glucose to gluconic acid catalyzed by glucose oxidase was companied with the formation of H2O2, the sensing protocol has been successfully utilized for the determination of glucose in human blood samples. The results were in good agreement with those determined by a local hospital. This colorimetric sensor thus holds great promises in clinical applications.  相似文献   

10.
《Analytical letters》2012,45(5):885-897
Hemoglobin (Hb) was successfully immobilized on a gold electrode modified with gold nanoparticles (AuNPs) via a molecule bridge 1,6-hexanedithiol (HDT). The AFM images suggested that the HDT/gold electrode could adsorb more AuNPs. UV-vis spectra indicated that Hb on AuNPs/HDT film retained its near-native secondary structures. The electrochemical behaviors of the sensor were characterized with cyclic voltammetric techniques. The resultant electrode displayed an excellent electrocatalytical response to the reduction of hydrogen peroxide (H2O2). The linear relationship existed between the catalytic current and the H2O2 concentration ranging from 5.0 × 10?8 to 1.0 × 10?6 mol · L?1. The detection limit (S/N = 3) was 1.0 × 10?8 mol · L?1.  相似文献   

11.
A new electrochemical sensor based on Fe3O4@SiO2‐PANI‐Au nanocomposite was fabricated for modification of glassy carbon electrode (Fe3O4@SiO2‐PANI‐Au GCE). The Fe3O4@SiO2‐PANI‐Au nanocomposite was characterized by TEM, FESEM‐EDS‐Mapping, XRD, and TGA methods. The Fe3O4@SiO2‐PANI‐Au GC electrode exhibited an acceptable sensitivity, fast electrochemical response, and good selectivity for determination of quercetin. Under optimal conditions, the linear range for quercetin concentrations using this sensor was 1.0×10?8 to 1.5×10?5 mol L?1, and the limit of detection was 3.8×10?9 mol L?1. The results illustrated that the offered sensor could be a possible alternative for the measurement of quercetin in food samples and biological fluids.  相似文献   

12.
《Electroanalysis》2006,18(5):471-477
The precursor film was first formed on the Au electrode surface based on the self‐assembly of L ‐cysteine and the adsorption of gold colloidal nanoparticles (nano‐Au). Layer‐by‐layer (LBL) assembly films of toluidine blue (TB) and nano‐Au were fabricated by alternately immersing the electrode with precursor film into the solution of toluidine blue and gold colloid. Cyclic voltammetry (CV) and quartz crystal microbalance (QCM) were adopted to monitor the regular growth of {TB/Au} bilayer films. The successful assembly of {TB/Au}n films brings a new strategy for electrochemical devices to construct layer‐by‐layer assembly films of nanomaterials and low molecular weight materials. In this article, {TB/Au}n films were used as model films to fabricate a mediated H2O2 biosensor based on horseradish peroxidase, which responded rapidly to H2O2 in the linear range from 1.5×10?7 mol/L to 8.6×10?3 mol/L with a detection limit of 7.0×10?8 mol/L. Morphologies of the final assembly films were characterized with scanning probe microscopy (SPM).  相似文献   

13.
In this work, a novel sensor for detecting hydrogen peroxide was constructed on the base of nanotubular TiO2 and platinum nanoparticles. The morphology, structural, and electrochemical properties of the Pt/TiO2 nanocomposite electrodes were characterized by SEM, XRD and electrochemical methods. With an operating potential of +0.3 V versus Ag/AgCl, the sensor produces catalytic oxidation currents at the nanocomposite electrode, which can be exploited for quantitative determinations. The amperometric signals are linearly proportional to hydrogen peroxide concentration in the range 4×10?6 to 1.25×10?3 M. The regression equation is I (μA)=0.85 c (mM)+0.16 with a correction coefficient of 0.997. At a signal‐to‐noise ratio of 3, a detection limit of 4.0 μM H2O2 can be observed for the nanocomposite electrode. In addition, the sensor has a good stability and reproducibility. The construction process is simple and inexpensive. The results demonstrated that nanotubular TiO2 exhibits great prospect for developing a class of ideal and novel bioreactors and biosensors.  相似文献   

14.
We used a new reactive species OH? to fabricate active horseradish peroxidase (HRP) micropatterns with a high resolution by scanning electrochemical microscopy (SECM) coupled with a carbon fiber disk electrode as the SECM tip. In this method, except for active HRP micropatterns predesigned other regions on a HRP‐immobilized substrate were deactivated by OH? generated at the tip held at ?1.7 V in 1.0 mol/L KCl containing 2.0×10?3 mol/L benzoquinone (BQ) (pH 8.0). The feedback mode of SECM with a tip potential of ?0.2 V was used to characterize the active HRP micropatterns in 1.0 mol/L KCl containing 2.0×10?3 mol/L BQ and 2.0×10?3 mol/L H2O2.  相似文献   

15.
A biomimetic sensor containing the oxo‐bridged dinuclear manganese‐phenanthroline complex incorporated into a cation‐exchange polymeric film deposited onto glassy carbon electrode for detection of sulfite was studied. Cyclic voltammetry at the modified electrode in universal buffer showed a two electron oxidation/reduction of the couple MnIV(μ‐O)2MnIV/MnIII(μ‐O)2MnIII. The sensor exhibited electrocatalytic property toward sulfite oxidation with a decrease of the overpotential of 450 mV compared with the glassy carbon electrode. A plot of the anodic current versus the sulfite concentration for potential fixed (+0.15 V vs. SCE) at the sensor was linear in the 4.99×10?7 to 2.49×10?6 mol L?1 concentration range and the concentration limit was 1.33×10?7 mol L?1. The mediated mechanism was derived by Michaelis? Menten kinetics. The calculated kinetics values were Michaelis? Menten rate constant= =1.33 µmol L?1, catalytic rate constant=6.06×10?3 s?1 and heterogeneous electro‐chemical rate constant=3.61×10?5 cm s?1.  相似文献   

16.
Based on single‐walled carbon nanotubes (SWCNTs) modified glassy carbon electrode (GCE/SWCNTs), a novel method was presented for the determination of L ‐tyrosine. The GCE/SWCNTs exhibited remarkable catalytic and enhanced effects on the oxidation of L ‐tyrosine. In 0.10 mol/L citric acid‐sodium citrate buffer solution, the oxidation potential of L ‐tyrosine shifted negatively from +1.23 V at bare GCE to +0.76 V at GCE/SWCNTs. Under the optimized experimental conditions, the linear range of the modified electrode to the concentration of L ‐tyrosine was 5.0×10?6–2.0×10?5 mol/L (R1=0.9952) and 2.7×10?5–2.6×10?4 mol/L (R2=0.9998) with a detection limit of 9.3×10?8 mol/L. The kinetic parameters such as α (charge transfer coefficient) and D (diffusion coefficient) were evaluated to be 0.66, 9.82×10?5 cm2 s?1, respectively. And the electrochemical mechanism of L ‐tyrosine was also discussed.  相似文献   

17.
A surface‐renewable tris(1, 10‐phenanthroline‐5, 6‐dione) iron (D) hexafluorophosphate (FePD) modified carbon ceramic electrode was constructed by dispersing FePD and graphite powder in methyltrimethoxysilane (MTMOS) based gels. The FePD‐modified electrode presented pH‐dependent voltammetric behavior, and its peak currents were diffusion‐controlled in 0.1 mol/L Na2SO4 + H2SO4 solution (pH = 0.4). In the presence of iodate, dear electrocatalytic reduction waves were observed and thus the chemically modified electrode was used as an amperometric sensor for iodate in common salt. The linear range, sensitivity, detection limit and response time of the iodate sensor were 5 × 10?6–1 × 10?2 mol/L, 7.448 μA·L/ mmol, 1.2 × 10?6 mol/L and 5 s, respectively. A distinct advantage of this sensor is its good reproducibility of surface‐renewal by simple mechanical polishing.  相似文献   

18.
IntroductionChlordiazepoxide (7 chloro 2 methylamino 5 phenyl 3H 1,4 benzodiazepine 4 oxide)showingpowerfulan tianxietyeffecthasbeenwidelyusedasapsychotherapeu ticdrug .Consequently ,theneedaroseforsensitiveandrapiddeterminationofchlordiazepoxideinblood ,urinean…  相似文献   

19.
《Analytical letters》2012,45(4):661-676
Abstract

A novel amperometric sensor of hydrogen peroxide was constructed. Hemoglobin (Hb) was successfully immobilized on nanometer‐sized SiO2, which was supported by chitosan. Chitosan was acted as dispersant. The determination of hydrogen peroxide was performed in the presence of an electron mediator hydroquinone. Hb immobilized on the SiO2/chitosan composite film displayed excellent electrocatalytical activity to the reduction of H2O2. The linear range of detection towards H2O2 was from 6.25×10?7 to 1.63×10?4mol/L with a detection limit of 1.8×10?7mol/L (S/N=3). The apparent Michaelis‐Menten constant (K app M) was found to be 0.75mmol/L.  相似文献   

20.
A novel enzyme-free electrochemical sensor for H2O2 was fabricated by modifying an indium tin oxide (ITO) support with (3-aminopropyl) trimethoxysilane to yield an interface for the assembly of colloidal gold. Gold nanoparticles (AuNPs) were then immobilized on the substrate via self-assembly. Atomic force microscopy showed the presence of a monolayer of well-dispersed AuNPs with an average size of ~4 nm. The electrochemical behavior of the resultant AuNP/ITO-modified electrode and its response to hydrogen peroxide were studied by cyclic voltammetry. This non-enzymatic and mediator-free electrode exhibits a linear response in the range from 3.0?×?10?5 M to 1.0?×?10?3 M (M?=?mol?·?L?1) with a correlation coefficient of 0.999. The limit of detection is as low as 10 nM (for S/N?=?3). The sensor is stable, gives well reproducible results, and is deemed to represent a promising tool for electrochemical sensing.
Figure
AuNPs/ITO modified electrode prepared by self-assembly method exhibit good electrocatalytic activity towards enzyme-free detection H2O2. The linear range of typical electrode is between 3.0?×?10?5 M and 1.0?×?10?3 M with a correlation coefficient of 0.999 and the limit detection is down to 1.0?×?10?8 M.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号