首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A continuous cyclic voltammetric study of methyldopa at gold micro electrode was carried out. The drug in phosphate buffer (pH 2.0) is adsorpted at 400 mV, giving rise to change in the current of well-defined oxidation peak of gold in the flow injection system. The proposed detection method has some of advantages, the greatest one of which are as follows: first, it is no more necessary to remove oxygen from the analyte solution and second, this is a very fast and appropriate technique for determination of the drug compound in a wide variety of chromatographic analysis methods. Signal-to-noise ratio has significantly increased by application of discrete Fast Fourier transform (FFT) method, background subtraction and two-dimensional integration of the electrode response over a selected potential range and time window. Also in this work some parameters such as sweep rate, eluent pH, and accumulation time and potential were optimized. The linear concentration range was of 1.0×10-7—1.0×10-11 mol•L-1 (r=0.9975) with a limit of detection and quantitation 0.004 nmol•L-1 and 0.03 nmol•L-1, respectively. The method has the requisite accuracy, sensitivity, precision and selectivity to assay methyldopa in tablets. The influences of pH of eluent, accumulation potential, sweep rate, and accumulation time on the determination of the methyldopa were considered.  相似文献   

2.
In this paper, an electrochemical application of bismuth‐film electrode (BiFE) fabricated via ex‐situ electrodeposition onto a glassy carbon electrode for testosterone determination was investigated in aqueous and aqueous/surfactant solutions. In cyclic voltammetry, the compound showed one irreversible and adsorption‐controlled reduction peak. The BiFE revealed good linear response in the examined concentration range of 1 to 45 nmol L?1 testosterone in Britton? Robinson buffer, pH 5.0 containing 3 mmol L?1 cetyltrimethylammonium bromide. The limit of detection was 0.3 nmol L?1 (0.09 ng mL?1). Finally, the BiFE was satisfactorily applied for quantitation of testosterone in both pharmaceutical (oil‐based ampoule) and biological (human urine) samples.  相似文献   

3.
A novel electrochemical sensor for sensitive detection of methyldopa at physiological pH was developed by the bulk modification of carbon paste electrode (CPE) with graphene oxide nanosheets and 3‐(4′‐amino‐3′‐hydroxy‐biphenyl‐4‐yl)‐acrylic acid (3,′AA). Applying square wave voltammetry (SWV), in phosphate buffer solution (PBS) of pH 7.0, the oxidation current increased linearly with two concentration intervals of methyldopa, one is 1.0×10?8–1.0×10?6 M and the other is 1.0×10?6–4.5×10?5 M. The detection limit (3σ) obtained by SWV was 9.0 nM. The modified electrode was successfully applied for simultaneous determination of methyldopa and hydrochlorothiazide. Finally, the proposed method was applied to the determination of methyldopa and hydrochlorothiazide in some real samples.  相似文献   

4.
《Electroanalysis》2005,17(8):719-723
A very sensitive and selective adsorptive cathodic stripping procedure for trace measurement of uranium is presented. The method is based on adsorptive accumulation of the uranium‐pyromellitic acid (benzene‐1,2,4,5‐tetracarboxylic acid) complex onto a hanging mercury drop electrode, followed by reduction of the adsorbed species by voltammetric scan using differential pulse modulation. Influences of effective parameters such as pH, concentration of pyromellitic acid, accumulation potential and accumulation time on the sensitivity were studied. The peak current was proportional to the concentration of U(IV) up to 40 ng mL?1 with a limit of detection of 0.136 ng mL?1 with an accumulation time of 120 s. The range of linearity enhanced to 71.4 ng mL?1and the detection limit improved to 0.058 ng mL?1with accumulation times of 60 s and 300 s respectively. The relative standard deviation for 10 replicate determination of 4.76 ng mL?1 U(IV) was equal to 2.7%. The possible interference by major cations and anions are investigated. The method was applied to the determination of uranium in some analytical grade salts, seawater and in synthetic samples corresponding to some uranium alloys with satisfactory results.  相似文献   

5.
N‐Phenylanthranilic acid was used as a complexing agent for determination of uranium(VI) by adsorptive cathodic stripping voltammetry. Under the optimal experimental conditions of the experimental parameters, the peak current was proportional to the concentration of U(VI) in the range 0.75–30 ng mL?1 and the detection limit was 0.036 ng mL?1. The influence of possible interferences was investigated. The method was applied for determination of uranium in waste water from uranium conversion facility and natural water samples. Application of the method for simultaneous determination of U(VI) and Cu(II) showed that these ions could be simultaneously determined in a single scan at relatively wide concentration range.  相似文献   

6.
The oxidation of acetaminophen was studied at a glassy carbon electrode modified with multi-walled carbon nanotubes and a graphite paste. Cyclic voltammety, differential pulse voltammetry and square wave voltammetry at various pH values, scan rates, and the effect of the ratio of nanotubes to graphite were investigated in order to optimize the parameters for the determination of acetaminophen. Square wave voltammetry is the most appropriate technique in giving a characteristic peak at 0.52 V at pH 5. The porous nanostructure of the electrode improves the surface area which results in an increase in the peak current. The voltammetric response is linear in the range between 75 and 2000 ng.mL?1, with standard deviations between 0.25 and 7.8%, and a limit of detection of 25 ng.mL?1. The method has been successfully applied to the analysis of acetaminophen in tablets and biological fluids.  相似文献   

7.
Cyclic voltammetric studies of isoproturon and carbendazim using polypyrrole modified glassy carbon electrode were carried out. The electrode and reaction conditions, which yielded maximum current signal, were selected for the development of stripping voltammetric procedure for the determination of the pesticides. The oxidation peak around 1.3?V obtained for isoproturon and carbendazim while employing polypyrrole modified electrode showed maximum current response. This peak was chosen for stripping analysis using square wave mode. The experimental parameters were optimized and the calibration plot was obtained. The LOD was 0.5?ng?mL?1 for isoproturon and 5?ng?mL?1 for carbendazim. The relative standard deviation for 5 identical measurements was 2.81% and 3.33% for isoproturon and carbendazim respectively. The applicability of the method was verified by determining the pesticides in spiked soil and water samples.  相似文献   

8.
《Analytical letters》2012,45(5):947-956
Abstract

A new electrochemical substrate for horseradish peroxidase, methyl red, is reported. In this reaction system, horseradish peroxidase can catalyze the redox reaction of methyl red and H2O2. Methyl red exhibits a sensitive voltammetric peak at?0.51 V vs. Ag/AgCl reference electrode, the decrease of the peak current of methyl red is in proportion to the concentration of horseradish peroxidase (HRP). The linear range for determination of horseradish peroxidase is 5.0×10?8~5.0×10?7 g mL?1 and the detection limit is 1.8×10?8 g mL?1. The relative standard deviation is 3.3% when 2.0×10?7 g mL?1 HRP was sequentially determined 11 times. A voltammetric enzyme‐linked immunoassay method for the determination of estriol was developed, based on this electrochemical system. The linear range for determination of estriol is 1.0~1000.0 ng mL?1, and the detection limit is 0.33 ng mL?1. The relative standard deviation for 11 parallel determinations with 200 ng mL?1 estriol is 4.8%. Some pregnancy serum samples were analyzed with satisfactory results.  相似文献   

9.
This research introduces the design of an adsorptive stripping voltammetric method for the cerium(III) determination at a carbon paste electrode, chemically modified with dipyridyl‐functionalized nanoporous silica gel (DPNSG‐CPE). The electroanalytical procedure comprised two steps: the Ce(III) chemical accumulation at ?200 mV followed by the electrochemical detection of the Ce(III)/dipyridyl complex, using anodic stripping voltammetry. The factors, influencing the adsorptive stripping performance, were optimized including the modifier quantity in the paste, the electrolyte concentrations, the solution pH and the accumulation potential or time. The resulting electrode demonstrated a linear response over a wide range of Ce(III) concentration (1.0–28 ng mL?1). The precision for seven determinations of 4 and 10 ng mL?1 Ce(III) was 3.2% and 2.5% (relative standard deviation), respectively. The prepared electrode was used for the cerium determination in real samples and very good recovery results were obtained.  相似文献   

10.
《Analytical letters》2012,45(3):529-546
Abstract

A simple, fast, sensitive and fully validated differential pulse polarographic (DPP) method for the determination of trace amounts of moxifloxacin in pharmaceutics, serum and urine is reported. Moxifloxacin exhibited irreversible cathodic peak over the pH 5.00–11.00 in Britton–Robinson (B–R) buffer. At pH 10.00 (the analytical pH), a well‐defined peak at ?1.61 V versus saturated calomel electrode was obtained. The current has been characterized as being diffusion‐controlled process. The diffusion current constant (id) was 1.48±0.12 and the current–concentration plot was rectilinear over the range from 5×10?7 to 1×10?4 M with correlation coefficient (n=10) of 0.995.

The proposed method was applied to commercial tablets and average percentage recovery was in agreement with that obtained by spectrophotometric comparison method. The method was extended to the in vitro determination of moxifloxacin in spiked human serum and urine.  相似文献   

11.
A new method is described for the determination of lead based on the cathodic adsorptive stripping of the lead–nuclear fast red (NFR) at a carbon paste electrode (CPE). The differential pulse voltammograms of the adsorbed complex of lead–NFR are recorded from ?0.10 to ?0.60 V (versus Ag/AgCl electrode). Optimal conditions were found to be an electrode containing 25% paraffin oil and 75% high purity graphite powder, 4.0×10?5 mol L?1 NFR; buffer solution (pH of 3.0), accumulation potential and time, ?0.20 V, 60 and 120 s (for high and low concentration of lead), respectively. The results show that the complex can be adsorbed on the surface of the CPE, yielding one peak at ?0.34 V, corresponding to reduction of NFR in the complex at the electrode. The detection limit was found to be 0.2 ng mL?1 with a 120s accumulation time. The linear ranges are from 0.5 to 50 (tacc=120 s) and 50 to 200 ng mL?1 (tacc=60 s). Application of the procedure to the determination of lead in lake water, bottled mineral water, synthetic samples and sweet fruit‐flavored powder drinks samples gave good results.  相似文献   

12.
A sensitive and fast method for the simultaneous determination of trace amounts of nickel and cadmium in real samples has been described using differential pulse adsorptive stripping voltammetry (DPASV) by adsorptive accumulation of the N,N′‐bis(salicylaldehydo)4‐carboxyphenylenediamine (BSCPDA)–complex on the hanging mercury drop electrode (HMDE). As supporting electrolyte 0.02 mol L?1 ammonia buffers containing ligand has been used. Optimal analytical conditions were found to be: BSCPDA concentration of 42 μM, pH 9.6 and adsorption potential at ?50 mV versus Ag/AgCl. With an accumulation time of 20 s, the peaks current are proportional to the concentration of nickel and cadmium over the 1–180, and 0.5–200 ng mL?1 with detection limits of 0.06 and 0.03 ng mL?1 respectively. The sensitivity of method for determination of nickel and cadmium were obtained 0.54 and 0.98 nA mL ng?1, respectively. The procedure was applied to simultaneous determination of nickel and cadmium in some real and synthetic artificial samples with satisfactory results.  相似文献   

13.
《Electroanalysis》2005,17(14):1309-1316
The detection limit (about 0.017 μg mL?1) for voltammetric determination of iodide (peak at +0.87 V vs. Ag/AgCl at pH 2) at a glutaraldehyde‐cross‐linked poly‐L ‐lysine modified glassy carbon electrode involving oxidation to iodine was found to be several orders of magnitude lower than that for the voltammetric determination on a bare glassy carbon electrode. This method was applied successfully to the determination of iodide in two medicinal formulations. Idoxuridine was determined indirectly at the same electrode by accumulating it first at ?0.8 V vs. Ag/AgCl. At this potential the C? I bond in the adsorbed idoxuridine is reduced giving iodide, which is then determined at the modified electrode. The method was successfully applied to the determination of idoxuridine in a urine sample.  相似文献   

14.
《Electroanalysis》2006,18(11):1075-1080
The voltammetric behavior of uric acid (UA) has been studied at a multiwalled carbon nanotube‐ionic liquid (i.e., 1‐butyl‐3‐methylimidazolium hexafluorophosphate, BMIMPF6) paste coated glassy carbon electrode (MWNTs‐BMIMPF6/GC). It is found that UA can effectively accumulate at this electrode and cause a sensitive anodic peak at about 0.49 V (vs. SCE) in pH 4.0 phosphate buffer solutions. Experimental parameters influencing the response of the electrode, such as solution pH and accumulation time, are optimized for uric acid determination. Under the optimum conditions, the anodic peak current is linear to UA concentration in the range of 1.0×10?8 M to 1.0×10?6 M and 2.0×10?6 M to 2.0×10?5 M. The detection limit is 5.0×10?9 M for 180 s accumulation on open circuit. The electrode can be regenerated by successively cycling in a blank solution for about 3 min and exhibits good reproducibility. A 1.0×10?6 M UA solution is measured for eight times using the same electrode regenerated after every determination, and the relative standard deviation (RSD) of the peak current is 3.2%. As for different electrodes fabricated by the same way the RSD (i.e., the electrode to electrode deviation) is 4.2%(n=9). This method has been applied to the determination of UA in human urine samples, and the recoveries are 99%–100.6%. In addition, comparison is made between MWNTs‐BMIMPF6/GC and MWNTs/GC. Results show that the MWNTs‐BMIMPF6/GC exhibits higher sensitivity, selectivity and ratio of peak current to background current.  相似文献   

15.
An ionic liquid N‐hexylpyridinium hexafluorophosphate (HPPF6) modified carbon paste electrode was fabricated for the sensitive voltammetric determination of adenosine in this paper. Carbon ionic liquid electrode (CILE) was prepared by mixing graphite powder and HPPF6 together and the CILE was characterized by scanning electron microscopy (SEM) and electrochemical methods. The electrochemical behaviors of adenosine on the CILE were studied carefully. Compared with the traditional carbon paste electrode (CPE), a small negative shift of the oxidation peak potential appeared with greatly increase of the oxidation peak current, which indicated the presence of ionic liquid in the carbon paste not only as the binder but also as the modifier and promoter. Under the optimal conditions the oxidation peak current increased with the adenosine concentration in the range from 1.0×10?6 mol/L to 1.4×10?4 mol/L with the detection limit of 9.1×10?7 mol/L (S/N=3) by differential pulse voltammetry. The proposed method was applied to the human urine samples detection with satisfactory results.  相似文献   

16.
ABSTRACT

A modified carbon paste electrode has been developed for the determination of Pb(ΙΙ) ions based on Fe3O4/eggshell magnetic nanocomposite. The structure and morphology of Fe3O4/eggshell were analysed by X-ray diffraction (XRD) and scanning electron microscopy (SEM). The prepared nanocomposite was also characterized by Fourier transform infrared spectroscopy (FT-IR) and vibrating sample magnetometer (VSM). The electrochemical procedure was based on the accumulation and determination of Pb(ΙΙ) ions at the surface of the modified carbon paste electrode with Fe3O4/eggshell nanocomposites and carbon nanotubes by differential pulse anodic stripping voltammetry (DPASV). Various experimental parameters involved in the preconcentration of Pb(ΙΙ) ions and voltammetric stripping step were studied. Under the optimum conditions, the voltammetric peak current of Pb(ΙΙ) occurs at a potential about ?0.5 V. Also, the voltammetric peak current increased linearly with Pb(ΙΙ) concentration in the range of 0.5–200 ng mL?1 and a detection limit of 0.15 ng mL?1 was obtained for Pb(ΙΙ). The selectivity of the proposed electrode for Pb(ΙΙ) ions in the presence of some cations was also examined. The practical application of the proposed modified electrode was evaluated by the determination of Pb(ΙΙ) ions in human hair and water samples. The results were satisfactory for the spiked samples.  相似文献   

17.
A novel voltammetric method using the Ppyox/NFR/Au (poly pyrrole – nuclear fast red – gold) modified electrode was developed for simultaneous measurement of various combinations of ascorbic acid (AA) and methyldopa (MDA). Polypyrrole film was prepared by incorporation of nuclear fast red (NFR) as doping anion, during the electropolymerization of pyrrole onto a gold (Au) electrode in aqueous solution using cyclic voltammetric (CV) method, and then it was overoxidized at constant potential. Differential pulse voltammetry was utilized for the measurement of both analytes using modified electrode. Well‐separated voltammetric peaks were observed for ascorbic acid (AA) and methyldopa at the Ppyox/NFR/Au modified electrodes with peak separation of 0.210 V. It has been found that under optimum condition (pH 3.0), the oxidation of AA and MDA at the surface of the electrode occurs at a potential about 260 and 50 mV less positive than unmodified Au electrode respectively. The current catalytic oxidation peaks showed a linear dependent on the concentration of AA and MDA in the range of 9.0×10?6 to 1.0×10?3 and 1.0×10?7 to 2.0×10?5 mol L?1 respectively. The detection limit of 5.8×10?6 and 5.0×10?8 mol L?1 (S/N=3) were obtained for AA and MDA respectively. The modified electrode was used for determination of AA and MDA in some real samples such as human serum and tablet.  相似文献   

18.
An analytical procedure for the simultaneous determination in human urine of several thioamphetamine designer drugs (2C‐T and ALEPH series) is reported. The quantitative analysis was performed by liquid chromatography/tandem mass spectrometry and has been fully validated. The mass spectrometer was operated in positive‐ion, selected reaction monitoring (SRM) mode. In order to minimize interferences with matrix components and to preconcentrate target analytes, solid‐phase extraction was introduced in the method as a clean‐up step. The entire method was validated for selectivity, linearity, precision and accuracy. The method turned out to be specific, sensitive, and reliable for the analysis of amphetamine derivatives in urine samples. The calibration curves were linear over the concentration range of 1 to 100 ng mL?1 for all drugs with correlation coefficients that exceeded 0.996. The lower limits of detection (LODs) and quantification (LOQs) ranged from 1.2 to 4.9 ng mL?1 and from 3.2 to 9.6 ng mL?1, respectively. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

19.
《Electroanalysis》2006,18(9):931-934
A flow injection analysis (FIA) method for the determination of paracetamol in pharmaceutical drugs using a gold electrode modified with a self‐assembled monolayer (SAM) of 3‐mercaptopropionic acid is described. At optimized experimental conditions the dynamic concentration range was 0.15 to 15.0 mg L?1 with a detection limit of 0.2 μg mL?1 (S/N=3). The repeatability of current responses for injections of 10 μmol L?1 paracetamol was evaluated to be 3.2% (n=30) and the analytical frequency was 180 h?1. The lifetime of the modified electrode was found to be 15 days. The results obtained by using the proposed amperometric method for paracetamol determination in four different drug samples compared well with those found by spectrophotometry.  相似文献   

20.
Present work demonstrates the fabrication of new and facile sandwich‐type electrochemical immunosensor based on palladium nanoparticles (PdNPs), polyaniline (PANI) and fullerene‐C60 nanocomposite film modified glassy carbon electrode (PdNP@PANI‐C60/GCE) for ultrasensitive detection of Prostate‐specific antigen (PSA) biomarker. PdNP@PANI‐C60 was electrochemically synthesized on GCE and used as an electroactive substrate. PdNP@PANI‐C60 was characterized by scanning electron microscopy (SEM), energy‐dispersive X‐ray spectroscopy (EDS), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Primary antibody anti‐PSA (Ab1) was covalently immobilized on PdNP@PANI‐C60/GCE using NHS/EDC linkers. In the presence of PSA antigen, horseradish peroxidase secondary antibody (HRP‐Ab2) was brought into the surface of the electrode, developing stable amplified signals of H2O2 reduction. Under the optimal conditions, a linear curve for determination of PSA at the proposed immunosensor was 1.6×10?4 ng.mL?1 to 38 ng.mL?1 with a limit of detection (LOD) of 1.95×10?5 ng.mL?1. The proposed immunosensor was successfully validated in serum and urine samples towards PSA detection with satisfactory and acceptable results.  相似文献   