首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Microfluidic cell sorter allows efficient separation of small number of cells, which is beneficial in handling cells, especially primary cells that cannot be expanded to large populations. Here, we demonstrate a microfluidic fluorescence-activated cell sorter (μFACS) with a novel sorting mechanism, in which automatic on-chip sorting is realized by turning on/off the hydrodynamic gating valve when a fluorescent target is detected. Formation of the hydrodynamic gating valve was investigated by both numerical simulation and flow visualization experiment. Separation of fluorescent polystyrene beads was then conducted to evaluate this sorting mechanism and to optimize the separation conditions. Isolation of fluorescent HeLa-DsRed cells was further demonstrated with high purity and recovery rate. Viability of the sorted cells was also examined, suggesting a survival rate of more than 90%. We expect this sorting approach to find widespread applications in bioanalysis.  相似文献   

2.
The integration of complete analyses systems "on chip" is one of the great potentials of microfabricated devices. In this study we present a new pressure-driven microfabricated fluorescent-activated cell sorter chip with advanced functional integration. Using this sorter, fluorescent latex beads are sorted from chicken red blood cells, achieving substantial enrichments at a sample throughput of 12000 cells s(-1). As a part of the sorter chip, we have developed a monolithically integrated single step coaxial flow compound for hydrodynamic focusing of samples in flow cytometry and cell sorting. The structure is simple, and can easily be microfabricated and integrated with other microfluidic components. We have designed an integrated chamber on the chip for holding and culturing of the sorted cells. By integrating this chamber, the risk of losing cells during cell handling processes is eliminated. Furthermore, we have also developed integrated optics for cell detection. Our new design contributes to the ongoing efforts for building a fully integrated micro cell sorting and analysing system.  相似文献   

3.
This paper demonstrates a simple and easy setting up of a fused‐silica capillary‐assembled microfluidic system (μCE). This system incorporates a split‐flow pressure injection of the sample into a microfluidic system made from PDMS and a short (~20 cm) length of fused‐silica capillary as a separation unit. The on‐capillary detection was carried out by fiber optic spectrometry. A mixture of six cephalosporin antibiotics was separated in the μCE system and the obtained results were compared to those achievable by conventional CE. The six components could be separated within 8.5 min with the number of theoretical plates around 10 000.  相似文献   

4.
A novel microfluidic method of continually detecting and counting beads‐labeled cells from a cell mixture without fluorescence labeling was presented in this paper. The detection system is composed of a microfluidic chip (with a permanent magnet inserted along the channel), a signal amplification circuit, and a LabView® based data acquisition device. The microfluidic chip can be functionally divided into separation zone and detection zone. By flowing the pre‐labeled sample solution, the target cells will be sequentially separated at the separation zone by the permanent magnet and detected and counted at the detection zone by a microfluidic resistive pulse sensor. Experiments of positive separation and detection of T‐lymphocytes and negative separation and detection of cancer cells from the whole blood samples were carried out to demonstrate the effectiveness of this method. The methodology of utilizing size difference between magnetic beads and cell‐magnetic beads complex for beads‐labeled cell detection is simple, automatic, and particularly suitable for beads‐based immunoassay without using fluorescence labeling.  相似文献   

5.
In this work, ion mobility spectrometry (IMS) function as a detector and another dimension of separation was coupled with CE to achieve two‐dimensional separation. To improve the performance of hyphenated CE‐IMS instrument, electrospray ionization correlation ion mobility spectrometry is evaluated and compared with traditional signal averaging data acquisition method using tetraalkylammonium bromide compounds. The effect of various parameters on the separation including sample introduction, sheath fluid of CE and drift gas, data acquisition method of IMS were investigated. The experimental result shows that the optimal conditions are as follows: hydrodynamic sample injection method, the electrophoresis voltage is 10 kilo volts, 5 mmol/L ammonium acetate buffer solution containing 80% acetonitrile as both the background electrolyte and the electrospray ionization sheath fluid, the ESI liquid flow rate is 4.5 μL/min, the drift voltage is 10.5 kilo volts, the drift gas temperature is 383 K and the drift gas flow rate is 300 mL/min. Under the above conditions, the mixture standards of seven tetraalkylammoniums can be completely separated within 10 min both by CE and IMS. The linear range was 5–250 μg/mL, with LOD of 0.152, 0.204, 0.277, 0.382, 0.466, 0.623 and 0.892 μg/mL, respectively. Compared with traditional capillary electrophoresis detection methods, the developed CE‐ESI‐IMS method not only provide two sets of qualitative parameters including electrophoresis migration time and ion drift time, ion mobility spectrometer can also provide an additional dimension of separation and could apply to the detection ultra‐violet transparent compounds or none fluorescent compounds.  相似文献   

6.
Counting of Escherichia coli DH5α‐cell suspensions in PBS is performed using a microflow cytometer based on a photonic–microfluidic integrated device. Side‐scattered light signals are used to count the E. coli cells. A detection efficiency of 92% is achieved when compared with the expected count from a hemocytometer. The detection efficiency is correlated to the ratio of sample to sheath flow rates. It is demonstrated that E. coli can be easily distinguished from beads of similar sizes (2–4 μm) as their scattering intensities are different.  相似文献   

7.
Moon HS  Kwon K  Kim SI  Han H  Sohn J  Lee S  Jung HI 《Lab on a chip》2011,11(6):1118-1125
Circulating tumor cells (CTCs) are highly correlated with the invasive behavior of cancer, so their isolations and quantifications are important for biomedical applications such as cancer prognosis and measuring the responses to drug treatments. In this paper, we present the development of a microfluidic device for the separation of CTCs from blood cells based on the physical properties of cells. For use as a CTC model, we successfully separated human breast cancer cells (MCF-7) from a spiked blood cell sample by combining multi-orifice flow fractionation (MOFF) and dielectrophoretic (DEP) cell separation technique. Hydrodynamic separation takes advantage of the massive and high-throughput filtration of blood cells as it can accommodate a very high flow rate. DEP separation plays a role in precise post-processing to enhance the efficiency of the separation. The serial combination of these two different sorting techniques enabled high-speed continuous flow-through separation without labeling. We observed up to a 162-fold increase in MCF-7 cells at a 126 μL min(-1) flow rate. Red and white blood cells were efficiently removed with separation efficiencies of 99.24% and 94.23% respectively. Therefore, we suggest that our system could be used for separation and detection of CTCs from blood cells for biomedical applications.  相似文献   

8.
We report a high speed and high purity pulsed laser triggered fluorescence activated cell sorter (PLACS) with a sorting throughput up to 20,000 mammalian cells s(-1) with 37% sorting purity, 90% cell viability in enrichment mode, and >90% purity in high purity mode at 1500 cells s(-1) or 3000 beads s(-1). Fast switching (30 μs) and a small perturbation volume (~90 pL) is achieved by a unique sorting mechanism in which explosive vapor bubbles are generated using focused laser pulses in a single layer microfluidic PDMS channel.  相似文献   

9.
A high-discernment microflow cytometer with microweir structure   总被引:1,自引:0,他引:1  
Fu LM  Tsai CH  Lin CH 《Electrophoresis》2008,29(9):1874-1880
Using a simple and reliable isotropic wet etching process, we fabricated a microflow cytometer in which cells/particles are concentrated in the center of the sample stream using a 2-D hydrodynamic focusing technique and an microweir structure. Having focused the cells/particles, they are detected and counted using a LIF method. The experimental and numerical results confirm the effectiveness of the hydrodynamic sheath flows in squeezing the cells/particles into a narrow stream in the horizontal X-Y plane. Furthermore, it is shown numerically that the microweir structure results in the separation of the cells/particles in the vertical X-Z plane such that they pass through the detection region in a sequential fashion and can therefore be counted with a high degree of precision. The experimental results obtained using fluorescent polystyrene beads with diameters of 5 and 10 microm, respectively, confirm the suitability of the proposed device for microfluidic applications requiring the high-precision counting of particles or cells within a sample flow.  相似文献   

10.
This paper describes a micro flow cytometer system designed for efficient and non-damaging analysis of samples with small numbers of precious cells. The system utilizes actuation of Braille-display pins for micro-scale fluid manipulation and a fluorescence microscope with a CCD camera for optical detection. The microfluidic chip is fully disposable and is composed of a polydimethylsiloxane (PDMS) slab with microchannel features sealed against a thin deformable PDMS membrane. The channels are designed with diffusers to alleviate pulsatile flow behaviors inherent in pin actuator-based peristaltic pumping schemes to maximize hydrodynamic focusing of samples with minimal disturbances in the laminar streams within the channel. A funnel connected to the microfluidic channel is designed for efficient loading of samples with small number of cells and is also positioned on the chip to prevent physical damages of the samples by the squeezing actions of Braille pins during actuation. The sample loading scheme was characterized by both computational fluidic dynamics (CFD) simulation and experimental observation. A fluorescein solution was first used for flow field investigation, followed by use of fluorescence beads with known relative intensities for optical detection performance calibration. Murine myoblast cells (C2C12) were exploited to investigate cell viability for the sample loading scheme of the device. Furthermore, human promyelocytic leukemia (HL60) cells stained by hypotonic DNA staining buffer were also tested in the system for cell cycle analysis. The ability to efficiently analyze cellular samples where the number of cells is small was demonstrated by analyzing cells from a single embryoid body derived from mouse embryonic stem cells. Consequently, the designed microfluidic device reported in this paper is promising for easy-to-use, small sample size flow cytometric analysis, and has potential to be further integrated with other Braille display-based microfluidic devices to facilitate a multi-functional lab-on-a-chip for mammalian cell manipulations.  相似文献   

11.
The sensitivity of a microfluidic impedance flow cytometer is governed by the dimensions of the sample analysis volume. A small volume gives a high sensitivity, but this can lead to practical problems including fabrication and clogging of the device. We describe a microfluidic impedance cytometer which uses an insulating fluid to hydrodynamically focus a sample stream of particles suspended in electrolyte, through a large sensing volume. The detection region consists of two pairs of electrodes fabricated within a channel 200 μm wide and 30 μm high. The focussing technique increases the sensitivity of the system without reducing the dimensions of the microfluidic channel. We demonstrate detection and discrimination of 1 μm and 2 μm diameter polystyrene beads and also Escherichia coli. Impedance data from single particles are correlated with fluorescence emission measured simultaneously. Data are also compared with conventional flow cytometry and dynamic light scattering: the coefficient of variation (CV) of size is found to be comparable between the systems.  相似文献   

12.
提出了纳升级进样量的微流控芯片流动注射气体扩散分离光度检测系统. 制作三层结构微流控芯片, 在玻璃片上加工微反应通道, 用聚二甲基硅氧烷[Poly(dimethylsiloxane), PDMS]加工气体渗透膜和具有接收气体微通道的底片, 实现了生成气体的化学反应、气-液分离和检测在同一微芯片上的集成化. 采用缝管阵列纳升流动注射进样系统连续进样, 用吸光度法测定NH+4以验证系统性能. 结果表明, 该系统对NH+4的检出限为140 μmol/L(3σ), 峰高精度为3.7%(n=9). 在进样时间12 s、注入载流48 s和每次进样消耗200 nL试样条件下, 系统分析通量可达60样/h. 若加大样品量到800 nL, 使接收溶液停流1 min, 该系统对NH+4的检出限可达到35 μmol/L(3σ), 但分析通量降低到20样/h.  相似文献   

13.
Peripheral blood can provide valuable information on an individual’s immune status. Cell‐based assays typically target leukocytes and their products. Characterization of leukocytes from whole blood requires their separation from the far more numerous red blood cells. 1 Current methods to classify leukocytes, such as recovery on antibody‐coated beads or fluorescence‐activated cell sorting require long sample preparation times and relatively large sample volumes. 2 A simple method that enables the characterization of cells from a small peripheral whole blood sample could overcome limitations of current analytical techniques. We describe the development of a simple graphene oxide surface coated with single‐domain antibody fragments. This format allows quick and efficient capture of distinct WBC subpopulations from small samples (~30 μL) of whole blood in a geometry that does not require any specialized equipment such as cell sorters or microfluidic devices.  相似文献   

14.
In this work, a simple and novel sheath‐flow sample injection method (SFSIM) is introduced to reduce the band broadening of free‐flow zone electrophoresis separation in newly developed self‐balance free‐flow electrophoresis instrument. A needle injector was placed in the center of the separation inlet, into which the BGE and sample solution were pumped simultaneously. BGE formed sheath flow outside the sample stream, resulting in less band broadening related to hydrodynamics and electrodynamics. Hemoglobin and C‐phycocyanin were successfully separated by the proposed method in contrast to the poor separation of free‐flow electrophoresis with the traditional injection method without sheath flow. About 3.75 times resolution enhancement could be achieved by sheath‐flow sample injection method.  相似文献   

15.
The increasing resolution of three-dimensional (3D) printing offers simplified access to, and development of, microfluidic devices with complex 3D structures. Therefore, this technology is increasingly used for rapid prototyping in laboratories and industry. Microfluidic free flow electrophoresis (μFFE) is a versatile tool to separate and concentrate different samples (such as DNA, proteins, and cells) to different outlets in a time range measured in mere tens of seconds and offers great potential for use in downstream processing, for example. However, the production of μFFE devices is usually rather elaborate. Many designs are based on chemical pretreatment or manual alignment for the setup. Especially for the separation chamber of a μFFE device, this is a crucial step which should be automatized. We have developed a smart 3D design of a μFFE to pave the way for a simpler production. This study presents (1) a robust and reproducible way to build up critical parts of a μFFE device based on high-resolution MultiJet 3D printing; (2) a simplified insertion of commercial polycarbonate membranes to segregate separation and electrode chambers; and (3) integrated, 3D-printed wells that enable a defined sample fractionation (chip-to-world interface). In proof of concept experiments both a mixture of fluorescence dyes and a mixture of amino acids were successfully separated in our 3D-printed μFFE device.  相似文献   

16.
使用电荷耦合器件荧光检测毛细管电泳装置,在13min内基线分离了混合荧光染料的5个组份。详细研究了pH、电泳电压、曝光时间等多种因素对混合物电泳分离和荧光信号强度的影响。从具有光谱和时间分辨的三维电泳图上,可以直接鉴定和测量被分离的化合物。  相似文献   

17.
设计并制作了一种集多孔流分离(Multi-orifice flow fractionation,MOFF)技术与磁捕获技术于一体的用于特异性分离和捕获合成样本中肝癌细胞HepG2的多功能微流控细胞芯片.此芯片由玻璃基片和PDMS微通道盖片组成,PDMS盖片上含有3条进样通道、MOFF分离区和六边形腔体的细胞富集检测区.其中,MOFF分离区总长20 mm,由80组长度为0.18 mm、深度为50μm、收缩区域宽度为0.06 mm、扩张区域宽度为0.20 mm的半菱形收缩/扩张重复单元组成,每组收缩/扩张重复单元间的夹角为103.0°.实验以肝癌细胞HepG2-血细胞混悬液为样本;根据磁珠表面修饰c-Met抗体能与肝癌细胞HepG2特异性结合的原理,通过表面羧基化的磁珠、EDC(1 mg/mL)、NHS(1 mg/mL)和c-Met抗体制备了浓度为50μg/mL的免疫磁珠(Anti-MNCs)悬浮液.在样本流速为50μL/min条件下,利用外加磁场实现了血细胞合成样本中微量肝癌细胞HepG2的有效捕获;采用微波加热法以柠檬酸、硫脲为原料制备了用于荧光标记HepG2的碳量子点,在芯片上实现了血液中肝癌细胞HepG2的原位荧光可视化观测.对芯片检测区捕获到的HepG2进行了显微计数分析,对500μL血细胞(107 cell/mL)中含10个HepG2细胞的合成样本,捕获效率达到88.5%±6.7%(n=20).结果表明,所设计的多模式多功能的微流控芯片具有良好的肿瘤细胞分离和检测功能.  相似文献   

18.
Nam J  Lim H  Kim D  Jung H  Shin S 《Lab on a chip》2012,12(7):1347-1354
Pure separation and sorting of microparticles from complex fluids are essential for biochemical analyses and clinical diagnostics. However, conventional techniques require highly complex and expensive labeling processes for high purity separation. In this study, we present a simple and label-free method for separating microparticles with high purity using the elasto-inertial characteristic of a non-Newtonian fluid in microchannel flow. At the inlet, particle-containing sample flow was pushed toward the side walls by introducing sheath fluid from the center inlet. Particles of 1 μm and 5 μm in diameter, which were suspended in viscoelastic fluid, were successfully separated in the outlet channels: larger particles were notably focused on the centerline of the channel at the outlet, while smaller particles continued flowing along the side walls with minimal lateral migration towards the centerline. The same technique was further applied to separate platelets from diluted whole blood. Through cytometric analysis, we obtained a purity of collected platelets of close to 99.9%. Conclusively, our microparticle separation technique using elasto-inertial forces in non-Newtonian fluid is an effective method for separating and collecting microparticles on the basis of size differences with high purity.  相似文献   

19.
Continuous blood cell separation by hydrophoretic filtration   总被引:3,自引:0,他引:3  
Choi S  Song S  Choi C  Park JK 《Lab on a chip》2007,7(11):1532-1538
We propose a new hydrophoretic method for continuous blood cell separation using a microfluidic device composed of slanted obstacles and filtration obstacles. The slanted obstacles have a larger height and gap than the particles in order to focus them to a sidewall by hydrophoresis. In the successive structure, the height and gap of the filtration obstacles with a filtration pore are set between the diameters of small and large particles, which defines the critical separation diameter. Accordingly, the particles smaller than the criterion freely pass through the gap and keep their focused position. In contrast, the particles larger than the criterion collide against the filtration obstacle and move into the filtration pore. The microfluidic device was characterized with polystyrene beads with a minimum diameter difference of 7.3%. We completely separated polystyrene microbeads of 9 and 12 microm diameter with a separation resolution of approximately 6.2. This resolution is increased by 6.4-fold compared with our previous separation method based on hydrophoresis (S. Choi and J.-K. Park, Lab Chip, 2007, 7, 890, ref. 1). In the isolation of white blood cells (WBCs) from red blood cells (RBCs), the microfluidic device isolated WBCs with 210-fold enrichment within a short filtration time of approximately 0.3 s. These results show that the device can be useful for the binary separation of a wide range of biological particles by size. The hydrophoretic filtration as a sample preparation unit offers potential for a power-free cell sorter to be integrated into disposable lab-on-a-chip devices.  相似文献   

20.
Analysis of complex biological samples requires the use of high-throughput analytical tools. In this work, a microfluidic two-dimensional electrophoresis system was developed with mercury-lamp-induced fluorescence detection. Mixtures of 20 standard amino acids were used to evaluate the separation performance of the system. After fluorescent labeling with fluorescein isothiocyanate, mixtures of amino acids were separated by micellar electrokinetic chromatography in the first dimension and by capillary zone electrophoresis in the second. A double electrokinetic valve system was employed for the sample injection and the switching between separation channels. Under the optimized conditions, 20 standard amino acids were effectively separated within 20 min with high resolution and repeatability. Quantitative analysis revealed linear dynamic ranges of over three orders of magnitudes with detection limits at micromolar range. To further evaluate the reliability of the system, quantitative analysis of a commercial nutrition supplement liquid was successfully demonstrated. Figure    相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号