首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 42 毫秒
1.
Quaternary ammonium functionalised polymeric latex particles were coated onto the wall of a fused-silica capillary or onto a methacrylate monolithic bed synthesised inside the capillary in order to create ion-exchange stationary phases of varying ion-exchange capacity. These capillaries were coupled in-line to a separation capillary and used for the solid-phase extraction (SPE), preconcentration and subsequent separation of organic anions by capillary electrophoresis. A transient isotachophoretic gradient was used for the elution of bound analytes from the SPE phase using two modes of separation. The first comprised a low capacity SPE column combined with a fluoride/octanesulfonate discontinuous electrolyte system in which peak compression occurred at the isotachophoretic gradient front. The compressed anions were separated electrophoretically after elution from the SPE preconcentration phase and resolution was achieved by altering the pH of the electrolyte in which the separation was performed. In the second approach, a latex-coated monolithic SPE preconcentration stationary phase was used in combination with a fluoride/perchlorate electrolyte system, which allowed capillary electrochromatographic separation to occur behind the isotachophoretic gradient front. This method permitted the removal of weakly bound anions from the SPE phase, thereby establishing the possibility of sample clean-up. The effect of the nature of the strong electrolyte forming the isotachophoretic gradient on the separation and also on the preconcentration step was investigated. Capillary electrochromatography of inorganic and organic species performed on the latex-coated monolithic methacrylate column highlighted the presence of mixed-mode interactions resulting from the incomplete coverage of latex particles onto the monolithic surface. Analyte preconcentration prior to separation resulted in compression of the analyte zone by a factor of 300. Improvement in the limit of detection of up to 10400 times could be achieved when performing the preconcentration step and the presented methods had limits of detection (S/N=3) ranging between 1.5 and 12 nM for the organic anions studied.  相似文献   

2.
Cobalt(III) 5,10,15‐tris(4‐tert‐butylphenyl) corrole was synthesized and incorporated into plasticized poly(vinyl chloride) membranes and studied as a neutral carrier ionophore via potentiometry. This cobalt(III) complex has binding affinity to nitrite, and the resulting membrane electrode yields reversible and Nernstian response toward nitrite. Enhanced nitrite selectivity is observed over other anions, including lipophilic anions such as thiocyanate and perchlorate when an appropriate amount of lipophilic cationic sites are added to the membrane phase. Detection limit to nitrite is ca. 5 µM. Using tributylphosphate as the plasticizer with the cobalt(III) corrole species yields electrodes with enhanced nitrate selectivity.  相似文献   

3.
In this work,a novel hollow fiber membrane extractor was set up to extract inorganic anions from ethyl acetate using deionized water.Inorganic anions in slightly soluble organic solvents can be determined by the in-line hollow fiber membrane extractor coupled with ion chromatography at first time.Different aspects of the extraction procedure such as magnetic stirring speed, extraction flow rate and extraction time were optimized to achieve high extraction efficiency and good separation results. Satisfact...  相似文献   

4.
A method for the determination of traces of metallo-cyanide complexes by capillary zone electrophoresis is described. The suitability of preconcentration procedures based on supported liquid membranes in a flow system is investigated. Methyltrioctylammonium chloride in dibutyl ether is used as the active component of the membrane liquid. Due to ion-pairing mechanisms enrichment factors ranging from 50 to 600 can be achieved for cyanide complexes of Fe(II), Fe(III), Ni, Co, Pd, Pt, Cr, Au and Ag. The final capillary electrophoretic separation of the metallo-cyanides is performed off-line with a phosphate-triethanolamine buffer at pH 8.5 as the carrier electrolyte. Its separation selectivity and compatibility with the preconcentration procedure are optimized by addition of hexamethonium bromide, sodium perchlorate and sodium cyanide. Detection limits in the low nmol range can be achieved by direct UV detection at 214 nm. An approach for the analysis of free and labile cyanide is discussed which involves the conversion of these species into the nickel cyanide complex. Applications in the fields of environmental monitoring and industrial process control are possible.  相似文献   

5.
制备了白藜芦醇的分子印迹聚合物,用聚四氟乙烯管作为微固相萃取柱,连接在流动注射系统的八通阀上,对白藜芦醇进行富集和分离;经甲醇和乙酸混合洗脱液(9:1,V/V)在线洗脱后与酸性KMnO4发生化学发光反应.测定白藜芦醇的线性范围2.5×10-7~6.1×10-5g/mL,方法的检出限为(3σ)8×10-8g/mL,11次...  相似文献   

6.
On-line ion-exchange preconcentration, performed in a flow injection analysis system, has been integrated with capillary electrophoresis via a specially designed interface, and a sensitive and selective method for the determination of nitrite, nitrate, bromide and iodide using direct UV absorbance detection has been developed. Fivefold enrichment of these aforementioned anions can be realised. Separation conditions such as carrier electrolyte and concentration of electroosmotic modifier were investigated. Limits of detection were ca. 10 ng ml−1 for nitrite and nitrate in aqueous samples, and the overall relative standard deviation was about 5%.  相似文献   

7.
A simple sample preconcentration technique employing microwave-based evaporation for the determination of trace level bromate and perchlorate in drinking water with ion chromatography is presented. With a hydrophilic anion-exchange column and a sodium hydroxide eluent in linear gradient, bromate and perchlorate can be determined in one injection within 35 min. Prior to ion chromatographic analysis, the drinking water sample was treated with an OnGuard-Ag cartridge to remove the superfluous chloride and concentrated 20-fold using a PTFE beaker in a domestic microwave oven for 15 min.The recoveries of the anions ranged from 94.6% for NO2- to 105.2% for F-. The detection limits for bromate, perchlorate, iodate and chlorate were 0.1, 0.2, 0.1 and 0.2 microg/l, respectively. The developed method is applicable for the quantitation of bromate and perchlorate in drinking water samples.  相似文献   

8.
Preconcentration potential of micro-electromembrane extraction (μ-EME) across free liquid membrane (FLM) was examined with an anionic and a cationic dye, 4,5-dihydroxy-3-(p-sulfophenylazo)-2,7-naphthalene disulfonic acid, trisodium salt (SPADNS) and phenosafranine, respectively. For the first time, it was shown that the spatial flexibility of FLMs enabled application of tailored extraction units with mutually different shapes and migration cross-sections for FLMs, donor and acceptor solutions. Thus, e.g. conical units enabled easy and reproducible formation of a three-phase extraction system (donor/FLM/acceptor) with sub-μL volumes of acceptor solutions as well as rapid and highly efficient preconcentration of the two dyes. Quantitative measurements of resulting solutions were carried out by UV–vis spectrophotometry and enrichment factors of up to 98 were achieved for μ-EMEs of 20 μM SPADNS (50 μL) preconcentrated into 0.5 μL of pure water across 1-pentanol at −150 V for 18 min. Visual monitoring of the entire extraction process (with USB microscope camera) was possible across transparent extraction units, moreover, important extraction parameters, such as FLM dimensions and donor-to-acceptor solution volume ratio, which determine the mechanical stability of the membrane and maximum enrichment factor, respectively, were readily adjusted. Combination of μ-EME across FLMs with capillary electrophoresis (CE) was further shown suitable for preconcentration and determination of perchlorate in drinking water samples. Good repeatability of the μ-EME-CE method (RSD values better than 9.5%), linear relationship for the analytical signal vs. concentration (r2 better than 0.997) and enrichment factors of up to 30 were achieved for μ-EMEs of perchlorate across 1-pentanol and 1-hexanol based FLMs.  相似文献   

9.
Liu JF  Liang X  Jiang GB  Cai YQ  Zhou QX  Liu GG 《Talanta》2003,60(6):1155-1161
An on-line coupled continuous flow liquid membrane extraction (CFLME) and C18 precolumn system was developed for sample preconcentration in liquid chromatography determination. After preconcentration by CFLME, which is based on the combination of continuous flow liquid–liquid extraction and supported liquid membrane, bisphenol A (BPA) was enriched in 960 μl of 1 mol l−1 NaOH used as acceptor. This acceptor was on-line neutralized and transported onto the C18 precolumn where analytes were absorbed and focused. Then the focused analytes were injected onto a C18 analytical column for separation and detected at 220 nm with a diode array detector. CFLME related parameters such as flow rates, pH of donor and acceptor, and enrichment time were optimized. The proposed method presents a detection limit of 0.03 μg l−1 (S/N=3) when 60 ml samples was enriched with an enrichment time of 30 min. Compared with C18 based column-switching procedure, this proposed procedure presents similar sample throughput and lower detection limits. The proposed method was successfully applied to determine BPA in tap water, river water, and municipal sewage effluent samples.  相似文献   

10.
The global determination of anionic surfactants is proposed by using flow injection potentiometry, and by employing specifically developed tubular flow-through ion selective electrodes (ISEs). The low concentration requirements needed for the environmental application are obtained with an on-line preconcentration stage embedded in the flow system, which has as its goal the unattended monitoring of anionic surfactants in surface waters. The on-line preconcentration is achieved by employing an octadecylsilica extraction disk in the FIA system. This stage performs the solid phase extraction (SPE) for the enrichment and purification of the target analytes from common interfering anions. The outlined procedure improves the detection limit of a direct injection system, which is decreased from 10 to 0.25 μM by using a preconcentration volume of 3.0 mL and 50 μL of 75% acetonitrile in water as the eluent. Precision was estimated as 2.9% relative standard deviation (n = 20) for a 0.25 μM (0.070 mg·L− 1) sodium docecylsulfate standard.  相似文献   

11.
Silica monoliths coated with functionalised latex particles have been prepared for use in monolithic ion-exchange capillary electrochromatography (IE-CEC) for the separation of inorganic anions. The ion-exchange monoliths were prepared using 70 nm quaternary ammonium, anion-exchange latex particles, which were bound electrostatically to a monolithic silica skeleton synthesised in a fused silica capillary. The resulting stationary phases were characterised in terms of their chromatographic performance and capacity. The capacity of a 50 microm diameter 25 cm latex-coated silica monolith was found to be 0.342 nanoequivalents and 80,000 theoretical plates per column were typically achieved for weakly retained anions, with lower efficiency being observed for analytes exhibiting strong ion-exchange interaction with the stationary phase. The electroosmotic flow (EOF) was reversed after the latex-coating was applied (-25.96 m2 V(-1) s(-1), relative standard deviation (RSD) 2.8%) and resulted in anions being separated in the co-EOF mode. Ion-exchange interactions between the analytes and the stationary phase were manipulated by varying the ion-exchange selectivity coefficient and the concentration of a competing ion (phosphate or perchlorate) present in the electrolyte. Large concentrations of competing ion (greater than 1M phosphate or 200 mM perchlorate) were required to completely suppress ion-exchange interactions, which highlighted the significant retention effects that could be achieved using monolithic columns compared to open tubular columns, without the problems associated with particle-packed columns. The latex-coated silica monoliths were easily produced in bulk quantities and performed reproducibly in acidic electrolytes. The high permeability and beneficial phase ratio makes these columns ideal for micro-LC and preconcentration applications.  相似文献   

12.
A simple, rapid, and sensitive extraction-spectrophotometric method has been developed for the determination of trace amounts of perchlorate. This method is based on the extraction of perchlorate as an ion pair with thionine into isobuthyl methyl ketone and measuring the absorbance of the organic phase at 603 nm. The effect of different variables such as pH, reagent concentrations, and standing time was investigated and optimum conditions were established. The effects of other cations and anions on the extraction were also studied. The calibration curve was linear in the range of 40–1000 ng mL?1 with correlation coefficient of 0.9998. The detection limit based on 3Sb criterion was 23 ng mL?1 and the relative standard deviation for 400 ng mL?1 of perchlorate was 1.9%. The proposed method was applied to determination of perchlorate in water samples.  相似文献   

13.
The determination of perchlorate in complex matrices by ion chromatography (IC) with an online preconcentration and preelution technique is discussed. The method was applied to different sample types containing large concentrations of matrix anions that would otherwise interfere with analysis via conventional IC. The present approach was highly effective in removing most of the matrix anions and was thus resistant to the interferences commonly encountered in a high ionic strength background. Method performance was evaluated by analyzing for low-level perchlorate in synthetic high ionic strength solutions, tissue extracts, and hydroponic nitrate fertilizer samples. Not only is it easier to practice the present method compared to USEPA Method 314.0, but for most of these samples the present approach provided equal to or better recovery of perchlorate than Method 314.0. With a sample of specific conductance 12,650 μS cm−1, for example, the present method provided a perchlorate recovery of 101% at the 25 μg L−1 level versus 89% by EPA Method 314.0. Method detection limits of perchlorate in hydroponic fertilizer samples with this method (130-190 μg kg−1) are the lowest thus far reported.  相似文献   

14.
A continuous flow liquid membrane extraction (CFLME)-C18 precolumn-liquid chromatography system was developed for preconcentration and determination of chlorinated phenols (CPs). After preconcentration by CFLME, which is based on the combination of continuous flow liquid-liquid extraction and supported liquid membrane, CPs were enriched in 960 μl of 0.5 mol l−1 NaOH used as acceptor. This acceptor was on-line neutralized and transported onto the C18 precolumn where analytes were absorbed and focused. Then the focused analytes were injected onto the C18 analytical column for separation and detected at 215 nm with a diode array detector. CFLME related parameters such as flow rates, pH of donor and acceptor concentration were optimized. The proposed method presents detection limits of 0.02-0.09 μg l−1 (S/N=3) when 100 ml samples were enriched. The proposed method was successfully applied to determine CPs in tap water and river water samples with spiked recoveries in the range of 70-121%.  相似文献   

15.
Electrochemically controlled solid-phase extractions of anions were interfaced on-line to electrospray mass spectrometry (ESI-MS) and inductively coupled plasma mass spectrometry (ICP-MS), using polypyrrole coated electrodes and a thin-layer electrochemical (EC) flow cell. The results indicate that electrochemically controlled solid-phase extraction (EC-SPE) can be used as a versatile potential controlled sample preparation technique for a range of anions and that the properties of the polypyrrole coatings can be modified by altering the electrodeposition conditions. In the present study, the influence of interfering anions (i.e., fluoride and sulfate), and the anion used during the electropolymerisation, on the bromide extraction recovery was investigated for EC-SPE interfaced to ICP-MS. The results of these experiments show that the interference due to the presence of similar concentrations of sulfate can be reduced when using a polypyrrole coating electropolymerised in the presence of bromide ions. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) measurements were also used to study the morphology of the coatings, as well as the variations in the film thickness within the coatings. The effect of different desorption techniques on the bromide preconcentration factor in the ICP-MS on-line flow system was also examined. Stopped-flow desorption was found to give rise to significantly increased preconcentration factors in comparison with desorptions in flowing solutions. While the desorption efficiency depends on the type of desorption electrolyte (the electrolyte in which the desorption takes place), due to the competing influx of cations, the influence of the pH on the switching charge of the polypyrrole coating was found to be small, at constant ionic strength. To study the applicability of the EC-SPE technique with respect to real samples, investigations were also made with tap water samples spiked with different bromide concentrations. The results of these experiments, which were carried out using a modified thin-layer EC flow cell allowing in situ polymerisation of polypyrrole yielding a polymer plug covering the cross section of the channel, demonstrate that 3 microM concentrations of bromide could be detected in the tap water sample. This demonstrates that the extraction technique allows extractions of low concentrations of ions in the presence of significantly higher concentrations of other similar ions. The fact that the extraction and desorption steps are electrochemically controlled makes EC-SPE particularly well suited for inclusion in miniaturised lab-on-a-chip systems.  相似文献   

16.
A simple and sensitive single step electro membrane extraction (EME) procedure was demonstrated for biological organic anions with determination by ion chromatography (IC). Nitrite, adipate, oxalate, iodide, fumarate, thiocyanate and perchlorate were extracted from aqueous donor solutions, across a supported liquid membrane (SLM) consisting of methanol impregnated in the walls of a porous polypropylene membrane bag and into an alkaline aqueous acceptor solution in the lumen of the propylene envelope by the application of potential of 12 V applied across the SLM. The acceptor solution was analyzed by IC. Parameters affecting the extraction performance such as type of SLM, extraction time, pH of the donor and acceptor solution, and extraction voltage were studied. The most favorable EME conditions were methanol as the SLM, extraction time of 5 min, pH of acceptor and sample solutions of 12 and 4, respectively, and a voltage of 12 V. Portable 12 V batteries were used in the study. Under these optimized conditions, all anions had enrichment factors ranging from 3.6 to 36.2 with relative standard deviations (n = 3) of between 6.6 and 17.5%. Good linearity ranging from 0.1 to 10 μg mL−1 with coefficients of correlation (r) of between 0.9981 and 0.9996 were obtained. The limits of detection of the EME-IC method were from 0.01 to 0.14 μg mL−1. The developed methodology was applied to amniotic fluid samples to evaluate the feasibility of the method for real applications.  相似文献   

17.
The possible application of the supported liquid membrane (SLM) technique for the extraction of glyphosate is presented. For the extraction of this compound the SLM system has been applied with utilisation of Aliquat 336 as a cationic carrier incorporated into the membrane phase. The extraction efficiency of glyphosate [N-(phosphonomethyl)glycine] is dependent on the donor phase pH, carrier concentration in the organic phase and NaCl concentration in the acceptor phase. The optimal extraction conditions are: donor phase pH>11, acceptor phase of 2 M NaCl solution and the organic phase composed of 20% (w/w) Aliquot 336 solution in di-hexyl ether. Counter-coupled transport of chloride anions from the acceptor phase to the donor phase is a driving force of the mass transfer in this system.  相似文献   

18.
A flow-through fluorescence bulk optode for the flow-injection determination of perchlorate is described. As the active constituents the optode incorporates the lipophilized pH indicator fluorescein octadecyl ester and methyl tridodecyl ammonium chloride, dissolved in a plasticized poly (vinyl) chloride membrane entrapped in a cellulose support. The optode is applied in conjunction with the flow injection technique for perchlorate determination at pH 4.5 (acetic-acetate). The sensor is readily regenerated with the pH 10.4 (TRIS) carrier solution. The analytical characteristics of this optode with respect to perchlorate response time, dynamic measurement range, reproducibility and selectivity are discussed. The proposed FI method is applied to the determination of perchlorate in waters from different sources.  相似文献   

19.
Rostampour L  Taher MA 《Talanta》2008,75(5):1279-1283
Natural clinoptilolite was used as a sorbent material for solid phase extraction and preconcentration of vanadium. The clinoptilolite was first saturated with a cation such as nickel(II) and then modified with benzyldimethyltetradecyleammonium chloride (BDTA) for increasing sorption of 4-(2-pyridylazo)resorcinol (PAR). Vanadium–PAR complex was quantitatively retained on the sorbent by the column method at the pH range 6.2–7.0 at a flow rate of 1 mL min−1. It was removed from the column with 5.0 mL of dimethylformamide solution at a flow rate of 0.8 mL min−1 and determined by UV–vis spectrophotometry at λmax = 550 nm. 0.031 μg of vanadium can be concentrated from 450 mL of aqueous sample (where detection limit as 0.07 ng mL−1 with preconcentration factor of 90). Relative standard deviation for eight replicate determination of 5.0 μg of vanadium in final solution is 2.1%. The interference of number of anions and cations has been studied in detail to optimize the conditions and method was successfully applied for determination of all vanadium as V(IV) form in standard samples.  相似文献   

20.
Simon J  Moskvin LN 《Talanta》1999,49(5):54-988
With the intention of combining partition chromatography and membrane techniques, we succeeded in developing the chromatomembrane cell which has proved to be reliable as an extraction and preconcentration manifold in flow injection analysis. With this technique, two immiscible phases can be induced to flow independently through a block of biporous (macro and micro) PTFE in order to promote analyte exchange. Consequently, the application of chromatomembrane cells in environmental analysis resolves all problems of sample pretreatment simply and effectively whenever a preconcentration step by gas/liquid or liquid/liquid solvent extraction is included. The link-up with analyzers (AAS, UV–Vis photometry, GC, IC, HPLC, voltammetry, ion selective electrodes, etc.) makes possible computer aided automization for environmental monitoring.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号