首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A pressure‐assisted CEC with ESI‐MS based on poly(1‐hexadecene‐co‐trimethylolpropane trimethacrylate) monolithic column for rapid analysis of two β2‐agonists and three narcotics was established in this article. After the organic polymer‐based monolithic column was prepared by an in‐situ polymerization procedure, a systematic investigation of the pressure‐assisted CEC separation and ESI‐MS detection parameters was performed. Baseline separation of the studied analytes could be obtained using the solution containing 75% ACN v/v and 20 mmol/L ammonium acetate with pH 8.0 as running buffer, when applying separation voltage of 20 kV and assisted pressure of 5 bar. Under the optimized conditions, two β2‐agonists and three narcotics could be completely resolved and accurately determined within 15 min. Finally, the proposed method was successfully used for real urine samples detection.  相似文献   

2.
The fast separation capability of a novel miniaturized capillary electrophoresis with an amperometric detection (μCE‐AD) system was demonstrated by determining clenbuterol and salbutamol in real samples. The effects of several factors such as the acidity and concentration of the running buffer, the separation voltage, the applied potential and the injection time on CE‐AD were examined and optimized. Under the optimum conditions, the two β‐agonists could be baseline separated within 60 s at a separation voltage of 2 kV in a 90 mmol/L H3BO3‐Na2B4O7 running buffer (pH 7.4), which was not interfered by ascorbic acid and uric acid. Highly linear response was obtained for above compounds over three orders of magnitude with detection limits ranging from 1.20×10?7 to 6.50×10?8 mol/L (S/N=3). This method was successfully used in the analysis of feed and meat products with relatively simple extraction procedures.  相似文献   

3.
This work is focused on the controlled drug release behavior of hyperbranched HPMA in the presence of β‐CD. Hence, three HPMA‐β‐CDs and a pure HPMA were synthesized by Michael addition polymerization. As a model drug, CLB (an anti‐cancer drug) was loaded into them via a solution method for in vitro release studies. The DSC results indicate that the CLB/polymer interactions are at the molecular level. Loading CLB into these polymers results in an evident increase in their glass transition temperatures, and ΔTg depends on the β‐CD content. The controlled‐release experiments show that the presence of β‐CD can appropriately slow the release of CLB from HPMA‐β‐CDs and adjust the ratio of CLB released in total drug loading.

  相似文献   


4.
《中国化学快报》2020,31(7):1835-1838
Both clenbuterol (CLB) and ractopamine (RAC) are β-adrenergic agonists. After long-term excessive intake, there will be adverse reactions such as headache, chest tightness, limb numbness, and serious life-threatening. Simultaneous detection of CLB and RAC in related samples is of great importance for human health. In this work, we outline a microfluidics-based indirect competitive immunoassay (MICI) system that can sensitively detect residual CLB and RAC in pork, swine blood and swine urine. The rapid detection of multiple samples can be achieved in one chip, which greatly improves the detection efficiency. This method has good stability and reproducibility and the microfluidic chips are easy to manufacture. The linear ranges for CLB and RAC detection by MICI are 0.1–2.5 ng/mL and 0.1–5 ng/mL, and the limits of detection (LODs) are 0.094 ng/mL and 0.091 ng/mL, respectively. This straightforward and portable immunoassay system provides a good platform for rapid detection of harmful substances in food samples.  相似文献   

5.
In this paper, a simple, effective and green capillary electrophoresis separation and detection method was developed for the quantification of underivatized amino acids (dl ‐phenylalanine; dl ‐tryptophan) using β‐Cyclodextrin and chiral ionic liquid ([TBA] [l ‐ASP]) as selectors. Separation parameters such as buffer concentrations, pH, β‐CD and chiral ionic liquid concentrations and separation voltage were investigated for the enantioseparation in order to achieve the maximum possible resolution. A good separation was achieved in a background electrolyte composed of 15 mm sodium tetraborate, 5 mm β‐CD and 4 mm chiral ionic liquid at pH 9.5, and an applied voltage of 10 kV. Under optimum conditions, linearity was achieved within concentration ranges from 0.08 to 10 µg/mL for the analytes with correlation coefficients from 0.9956 to 0.9998, and the analytes were separated in less than 6 min with efficiencies up to 970,000 plates/m. The proposed method was successfully applied to the determination of amino acid enantiomers in compound amino acids injections, such as 18AA‐I, 18AA‐II and 3AA. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

6.
A sensitive and effective micellar electrokinetic capillary chromatography with laser‐induced fluorescence detection approach was described for the determination of low molecular‐mass thiols using 1,3,5,7‐tetramethyl‐8‐phenyl‐(4‐iodoacetamido) difluoroboradiaza‐s‐indacene as the labeling reagent. After precolumn derivatization, baseline separation of six thiol compounds including cysteine, glutathione, N‐acetylcysteine, homocysteine, 6‐mercaptopurine, and penicillamine were achieved within 18 min. The optimal running buffer was composed of mixtures involving 25 mM sodium dodecyl sulfate, 25% (v/v) acetonitrile and 15 mM sodium phosphate buffer, pH 7.5. The detection limits (S/N = 3) were found as low as 40 pM under argon ion laser‐induced fluorescence detector (λex/λem = 488/520 nm), which were much better than the reported approaches. The accuracy and specificity of this assay for real samples were assured by a standard addition method. The proposed method has been applied to the analysis of thiols both in human plasma and plum flower samples with recoveries of 92.0–109.4%.  相似文献   

7.
A novel method of CE coupled with dual electrochemical detection has been developed for the determination of pathological metabolites of phenylalanine in urine samples. Factors influencing the separation and detection were examined and optimized. Five aromatic acid metabolites and a major coexisting interfering compound uric acid could be well separated within 23 min at a separation voltage of 16 kV using a 35 mmol/L SDS/60 mmol/L H3BO3‐Na2B4O7 running buffer (pH 8.2). Highly linear response was obtained for these five biomarker compounds over three orders of magnitude with detection limits ranging from 6.6 to 0.064 μg/mL (S/N=3). The average recovery and RSD were within the range of 92.6–121.0 and 1.0–12.0%, respectively. The proposed method has been used to detect the unconjugated aromatic acids simultaneously in urine samples with the advantages of obtaining more information about target analytes and avoiding redundant measurements and high assay cost, thus could find potential applications involving assays of biomarker compounds for the purpose of fast diagnose of some metabolic diseases including phenylketonuria.  相似文献   

8.
A novel chiral ionic liquid functionalized β‐cyclodextrin, 6‐O‐2‐hydroxpropyltrimethylammonium‐β‐cyclodextrin tetrafluoroborate ([HPTMA‐β‐CD][BF4]), was synthesized and used as a chiral selector in capillary electrophoresis. [HPTMA‐β‐CD][BF4] not only increased the solubility in aqueous buffer in comparison with the parent compound, but also provided a stable reversal electroosmotic flow, and the enantioseparation of eight chiral drugs was examined in phosphate buffer containing [HPTMA‐β‐CD][BF4] as the chiral selector. The effects of the [HPTMA‐β‐CD][BF4] concentration and the background electrolyte pH were studied. Moreover, the chiral separation abilities of β‐CD and [HPTMA‐β‐CD][BF4] were compared and possible mechanisms for the chiral recognition of [HPTMA‐β‐CD][BF4] are discussed. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
Non‐aqueous capillary electrophoresis–mass spectrometry (NACE‐MS) was developed for trace analyses of β‐agonists (i.e. clenbuterol, salbutamol and terbutaline) in pork. The NACE was in 18 mM ammonium acetate in methanol–acetonitrile–glacial acetic acid (66 : 33 : 1, v/v/v) using a voltage of 28 kV. The hyphenation of CE with a time‐of‐flight MS was performed by electrospray ionization interface employing 5 mM ammonium acetate in methanol–water (80 : 20, v/v) as the sheath liquid at a flow rate of 2 μL/min. Method sensitivity was enhanced by a co‐injection technique (combination of hydrodynamic and electrokinetic injection) using a pressure of 50 mbar and a voltage of 10 kV for 12 s. The method was validated in comparison with HPLC–MS‐MS. The NACE‐MS procedure provided excellent detection limits of 0.3 ppb for all analytes. Method linearity was good (r2 > 0.999, in a range of 0.8–1000 ppb for all analytes). Precision showed %RSDs of <17.7%. Sample pre‐treatment was carried out by solid‐phase extraction using mixed mode reversed phase/cation exchange cartridges yielding recoveries between 69 and 80%. The NACE‐MS could be successfully used for the analysis of β‐agonists in pork samples and results showed no statistical differences from the values reported by the Ministry of Public Health, Thailand using HPLC‐MS‐MS method. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
A novel method for the determination of galanthamine (GAL) in Bulbus Lycoridis Radiatae has been developed based on coupling CE with an end‐column tris(2,2′‐bipyridyl)ruthenium(II) electrochemiluminescence (ECL). Parameters affecting CE separation and ECL detection were investigated and optimized. Baseline separation of GAL from other components in the Bulbus Lycoridis Radiatae sample was achieved with an 18 mmol/L phosphate running buffer at pH 9.0. Under the optimized conditions: 12 kV CE‐separation voltage, ECL detection potential at 1.25 V with 5 mmol/L and 50 mmol/L phosphate buffer at pH 7.5 in the detection reservoir, the linear range of GAL concentration was from 0.8 ng/mL to 2 μg/mL, whereas the detection limit was 0.25 ng/mL (S/N=3). The proposed method was successfully demonstrated for the determination of GAL in Bulbus Lycoridis Radiatae.  相似文献   

11.
Nicotine (NC) and its related compounds (cotinine (CN), nornicotine (NN), anatabine (AT) and anabasine (AB)) were simultaneously enantioseparated by CE using a capillary with amino groups and sulfated β‐CD as a chiral selector. The optimum running conditions were found to be 30 mM acetate buffer (pH 5.0) containing 8% sulfated β‐CD with an applied voltage of +15 kV at 30°C using direct detection at 260 nm. Using a capillary coated with amino groups, the EOF migrates toward the positive pole. However, when sulfated β‐CD was added to the BGE, it was found that the EOF migrated toward the negative pole due to ionic adsorption of sulfated β‐CD to amino groups on the capillary inner wall. All the cationic analytes migrated as anions, suggesting that they formed stable anionic complexes with sulfated β‐CD. With this system and a simple pretreatment with mini‐cartridges, NC alkaloids in five cigarette samples were enantioseparated. As a result, each of the compounds except for CN was detected. In the case of NC, only (S)‐NC was detected (more than 99.9%), but in the case of NN, AT and AB, the ratios of (S)‐isomer to total isomers were in the ranges 58–70, 81–85 and 59–65%, respectively. On the other hand, only NC was detected in cigarette smoke and the ratio of (S)‐ and (R)‐NCs was 96:4. The amounts of NC alkaloids in cigarettes suggest that the production of (R)‐NC resulted from racemization due to the high temperature/burning of the cigarette.  相似文献   

12.
Graphene/mono‐(6‐amino‐6‐deoxy)‐β‐cyclodextrin multilayer films composed of graphene sheet (GS) and mono‐(6‐amino‐6‐deoxy)‐β‐cyclodextrin (NH2β‐CD) were fabricated easily by two steps. First, negatively charged graphene oxide (GO) and positively charged mono‐(6‐amino‐6‐deoxy)‐β‐cyclodextrin (NH2β‐CD) were layer‐by‐layer (LBL) self‐assembled on glassy carbon electrode (GCE) modified with a layer of poly(diallyldimethylammonium chloride) (PDDA). Then graphene/mono‐(6‐amino‐6‐deoxy)‐β‐cyclodextrin (GS/NH2β‐CD) multilayer films were built up by electrochemical reduction of graphene oxide/mono‐(6‐amino‐6‐deoxy)‐β‐cyclodextrin (GO/NH2β‐CD). Combining the high surface area of GS and the active recognition sites on β‐cyclodextrin (β‐CD), the GS/NH2β‐CD multilayer films show excellent electrochemical sensing performance for the detection of DA with an extraordinary broad linear range from 2.53 to 980.05 µmol·L?1. This study offers a simple route to the controllable formation of graphene‐based electrochemical sensor for the detection of DA.  相似文献   

13.
Enantiomeric separation and detection of 1,1′‐binaphthyl‐2,2′‐diamine (BNA) has been successfully optimized by MEKC‐ESI‐MS using a polymeric surfactant polysodium N‐undecenoxycarbonyl‐L‐leucinate (poly‐L‐SUCL) as a pseudostationary phase. In the first step, MEKC conditions were optimized by a five‐factor three‐level central composite design (CCD) of experiment. All five MEKC factors (buffer pH, percentage of ACN in the running buffer, concentration of surfactant, concentration of ammonium acetate (NH4OAc), and voltage) were found significant to the responses (measured as the chiral resolution and analysis time). The interactions between MEKC factors were further evaluated using a quadratic model equation which allowed the generation of 3‐D response surface image to reach the optimum conditions. To obtain the best S/N, sheath liquid composition and spray chamber parameters were successfully optimized using the same strategy. Baseline enantiomeric resolution in less than 20 min and optimum MS signal of BNA enantiomers (S/N = 45 at 0.4 mg/mL) were ultimately achieved at the optimized conditions. The adequacy of the model was validated by experimental runs at the optimal predicted conditions. The predicted results were found to be in good agreement with the experimental data.  相似文献   

14.
In general capillary zone electrophoresis (CZE) separation models, o‐, m‐, and p‐phenylenediamine isomers can be separated in a weak acidic running buffer for their pKa values being 4.52, 5.64, 6.04, respectively, while o‐, m‐, and p‐dihydroxybenzene isomers can be separated in a weak basic buffer for their pKa values being 9.40, 9.40 and 10.04, respectively. So, it is hard to find a suitable running buffer at a fixed pH in normal CZE for simultaneous separation of these two groups of positional isomers. In this paper, a novel method based on alternately running two different pH buffers in CZE coupled with amperometric detection (CZE‐AD) was designed to simultaneously determine these two groups of positional isomers. It is found that when two different pH running buffers were employed alternately under appropriate order and time, the six analytes could be separated perfectly in less than 20 min and the detection limits were as low as 10–7 mol/L. Furthermore, the effects of working electrode potential, pH and concentration of running buffer, separation voltage and injection time on CZE–AD were investigated. Experimental results demonstrated that the introduced method was practical to simultaneously determine two groups of positional isomers with different pKa and had some advantages of high sensitivity, good repeatability and small sample requirement.  相似文献   

15.
Two novel types of crown ether capped β‐cyclodextrin (β‐CD) bonded silica, namely, 4′‐aminobenzo‐X‐crown‐Y (X=15, 18 and Y=5, 6, resp.) capped [3‐(2‐O‐β‐cyclodextrin)‐2‐hydroxypropoxy] propylsilyl‐appended silica, have been prepared and used as stationary phases in capillary electrochromatography (CEC) to separate chiral compounds. The two stationary phases have a chiral selector with two recognition sites: crown ether and β‐CD. They exhibit excellent enantioselectivity in CEC for a wide range of compounds. After inclusion of metal ions (Na+ or K+) from the running buffer into the crown ether units, the stationary phases become positively charged and can provide extra electrostatic interaction with ionizable solutes and enhance the dipolar interaction with polar neutral solutes. This enhances the host‐guest interaction with the solute and improves chiral recognition and enantioselectivity. Due to the cooperation of the anchored β‐CD and the crown ether, this kind of crown ether capped β‐CD bonded phase shows better enantioselectivity than either β‐CD‐ or crown ether bonded phases only. These new types of stationary phases have good potential for fast chiral separation with CEC.  相似文献   

16.
This work reported that ionic liquid (IL) ([Bmim] [PF6]) and sulfobutylether‐β‐CD (SBE‐β‐CD) were used as electrolyte additives for the separation and determination of camptothecin (CPT) alkaloids by CZE. Separation parameters such as the buffer type, pH, and concentration of the running buffer, the concentration of SBE‐β‐CD and IL, temperature, and separation voltage were all investigated in order to achieve the maximum possible resolution. The four analytes were baseline separated within 10 min in capillary at the separation voltage of 15 kV with a running buffer consisting of 20 mM borate buffer, 20 mM IL, and 100 mM SBE‐β‐CD at pH 9.0. Under such conditions, good linearity about two orders of magnitudes of peak areas was achieved for the investigated CPT alkaloids with the correlation coefficients ranging from 0.9946 to 0.9985. For all analytes, detection limits (S/N = 3) and quantitation limits (S/N = 10) range from 0.05 to 0.92 μg/mL and 0.17 to 3.06 μg/mL, respectively. The proposed method has not only been successfully applied to the separation and determination of CPT alkaloids but also showed that IL seemed to be a promising additive in CZE separation.  相似文献   

17.
《Electrophoresis》2018,39(17):2195-2201
A sensitive, fast, and effective method, field‐amplified sample stacking (FASS) in capillary electrophoresis, has been established for the separation and determination of corynoxine and corynoxine B. Hydroxypropyl‐β‐CD (HP‐β‐CD) and tetrabutylammonium‐L‐glutamic acid (TBA‐L‐Glu) were used as additives in the separation system. Electrokinetic injection was chosen to introduce sample from inlet at 10 kV for 50 s after a water plug (0.5 psi, 4 s) was injected to permit FASS. The running buffer (pH 6.1) was composed of 40 mM sodium dihydrogen phosphate solution, 130 mM HP‐β‐CD, and 10 mM TBA‐L‐Glu and the separation voltage was 20 kV. Under the optimum conditions, corynoxine and corynoxine B were successfully enriched and separated within 12 min and the sensitivity was improved approximately by 700–900 folds. Calibration curves were in a good linear relationship within the range of 62.5–5.00 × 103 ng/mL for both corynoxine and corynoxine B. The limits of detection (S/N = 3) and quantitation (S/N = 10) were 14.9, 45.2 ng/mL for corynoxine and 11.2, 34.5 ng/mL for corynoxine B, respectively. Finally, this method was successfully applied for the determination of corynoxine and corynoxine B in the stems with hooks of Uncaria rhynchophylla and its formulations.  相似文献   

18.
The outstanding properties such as large surface area, diverse structure, and accessible tunnels and cages make metal organic frameworks (MOFs) attractive as novel separation media in separation sciences. However, the utilization of MOFs in EKC has not been reported before. Here we show the exploration of zeolitic imidazolate framework‐8 (ZIF‐8), one of famous MOFs, as the pseudostationary phase (PSP) in EKC. ZIF‐8 nanocrystals were used as the PSP through dispersing in the running buffer (20 mM phosphate solution containing a 1% v/v methanol (pH 9.2)) to enhance the separation of the phenolic isomers (p‐benzenediol, m‐benzenediol, o‐benzenediol, m‐nitrophenol, p‐nitrophenol, and o‐nitrophenol). ZIF‐8 nanocrystals in the running buffer were negatively charged, and interacted with the phenolic hydroxyl groups of the analytes, and thus greatly improved the separation of the phenolic isomers. Inclusion of 200 mg L?1 ZIF‐8 in the running buffer as the background electrolyte gave a baseline separation of the phenolic isomers within 4 min. The relative standard deviations for five replicate separations of the phenolic isomers were 0.2–1.1% for migration time and 4.5–9.7% for peak area. The limits of detection varied from 0.44 to 2.0 mg L?1. The results show that nanosized MOFs are promising for application in EKC.  相似文献   

19.
In this study, a new CE method, employing a binary system of trimethyl‐β‐CD (TM‐β‐CD) and a chiral amino acid ester‐based ionic liquid (AAIL), was developed for the chiral separation of seven 2‐arylpropionic acid nonsteroidal anti‐inflammatory drugs (NSAIDs). In particular, the enantioseparation of ibuprofen, ketoprofen, carprofen, indoprofen, flurbiprofen, naproxen, and fenoprofen was improved significantly by supporting the BGE with the chiral AAIL l ‐alanine tert butyl ester lactate (l ‐AlaC4Lac). Parameters, such as concentrations of TM‐β‐CD and l ‐AlaC4Lac, and buffer pH, were systematically examined in order to optimize the chiral separation of each NSAID. It was observed that the addition of the AAIL into the BGE improved both resolution and efficiency significantly. After optimization of separation conditions, baseline separation (Rs>1.5) of five of the analytes was achieved in less than 11 min, while the resolution of ibuprofen and flurbiprofen was approximately 1.2. The optimized enantioseparation conditions for all analytes involve a BGE of 5 mM sodium acetate/acetic acid (pH 5.0), an applied voltage of 30 kV, and a temperature of 20°C. In addition, the results obtained by computing the %‐RSD values of the EOF and the two enantiomer peaks, demonstrated excellent run‐to‐run, batch‐to‐batch, and day‐to‐day reproducibilities.  相似文献   

20.
Chiral separation of 12 pairs of basic analyte enantiomers including oxybutynin, bambuterol, tradinterol, clenbuterol, clorprenaline, terbutaline, tulobuterol, citalopram, phencynonate, fexofenadine, salbutamol, and penehyclidine was conducted by capillary electrophoresis using a single‐isomer anionic β‐cyclodextrin derivative, heptakis‐(2,3‐diacetyl‐6‐sulfato)‐β‐cyclodextrin as the chiral selector. Parameters influencing separation were studied, including background electrolyte pH, heptakis‐(2,3‐diacetyl‐6‐sulfato)‐β‐cyclodextrin concentration, buffer concentration, and separation voltage. A background electrolyte consisting of 50 mM Tris‐H3PO4 and 6 mM heptakis‐(2,3‐diacetyl‐6‐sulfato)‐β‐cyclodextrin at pH 2.5 was found to be highly efficient for the separation of most enantiomers, with other conditions of normal polarity mode at 10 kV, detection wavelength of 210 nm using hydrodynamic injection for 3 s. Under the optimal conditions, baseline resolution (>1.50) for 11 pairs of enantiomers and somewhat lower resolution for penehyclidine enantiomers (1.17) were generated. Moreover, the possible mechanism of separation of clenbuterol, oxybutynin, salbutamol, and penehyclidine was investigated using a computational modeling method.  相似文献   