首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Electroanalysis》2005,17(17):1529-1533
The direct electrochemical oxidation of ascorbic acid at an edge plane pyrolytic graphite electrode (EPPG) is investigated and compared with other common carbon‐based electrodes, specifically glassy carbon, boron doped diamond and basal plane pyrolytic graphite. It is found that the EPPG electrode shows a significantly higher degree of electrochemical reversibility than the other electrode substrates giving rise to an analytically optimized limit of detection and sensitivity of 7.1×10?5 M and 0.065 A M?1 respectively.  相似文献   

2.
Pyrolytic carbon films (PCFs) were prepared by chemical vapor deposition (CVD) at different deposition temperatures. As an example of using PCF electrode in electroanalysis, the direct electrooxidation of ascorbic acid (AA) at the PCF electrode was investigated and compared with common carbon‐based electrodes such as glassy carbon (GC), edge plane pyrolytic graphite (EPPG), and basal plane pyrolytic graphite (BPPG) electrodes. It was found that the PCF electrodes prepared under deposition temperatures higher than 1050 °C showed a higher sensitivity and lower overpotential compared to the other carbon electrodes. The electrode was successfully applied for determination of AA in real samples.  相似文献   

3.
《Electroanalysis》2005,17(18):1627-1634
The behavior of chloride, bromide and iodide at edge plane pyrolytic graphite electrodes has been explored in aqueous acid solutions. The voltammetric response in each case has been compared with that of basal plane pyrolytic graphite, glassy carbon and boron‐doped diamond. The electrochemical oxidation of chloride is found to only occur on boron‐doped diamond while the electrochemical reversibility for the oxidation of bromide on edge plane pyrolytic graphite is similar to that seen at glassy carbon whilst being superior to basal plane pyrolytic graphite and boron‐doped diamond. In the case of iodide oxidation, edge plane and basal plane pyrolytic graphite and glassy carbon display similar electrode kinetics but are all superior to boron‐doped diamond. The analytical possibilities were examined using the edge plane pyrolytic graphite electrode for both iodide and bromine where is was found that, based on cyclic voltammetry, detection limits in the order of 10?6 M are possible.  相似文献   

4.
《Electroanalysis》2005,17(10):832-838
A simply and high selectively electrochemical method for simultaneous determination of hydroquinone and catechol has been developed at a glassy carbon electrode modified with multiwall carbon nanotubes (MWNT). It was found that the oxidation peak separation of hydroquinone and catechol and the oxidation currents of hydroquinone and catechol greatly increase at MWNT modified electrode in 0.20 M acetate buffer solution (pH 4.5). The oxidation peaks of hydroquinone and catechol merge into a large peak of 302 mV (vs. Ag/AgCl, 3 M NaCl) at bare glassy carbon electrode. The two corresponding well‐defined oxidation peaks of hydroquinone in the presence of catechol at MWNT modified electrode occur at 264 mV and 162 mV, respectively. Under the optimized condition, the oxidation peak current of hydroquinone is linear over a range from 1.0×10?6 M to 1.0×10?4 M hydroquinone in the presence of 1.0×10?4 M catechol with the detection limit of 7.5×10?7 M and the oxidation peak current of catechol is linear over a range from 6.0×10?7 M to 1.0×10?4 M catechol in the presence of 1.0×10?4 M hydroquinone with the detection limit of 2.0×10?7 M. The proposed method has been applied to simultaneous determination of hydroquinone and catechol in a water sample with simplicity and high selectivity.  相似文献   

5.
The electrocatalytic oxidation of oxalate at several carbon based electrodes including basal plane (BPPG) and edge plane (EPPG) pyrolytic graphite and glassy carbon (GC) electrode, was studied. The electrodes were examined for the sensing of oxalate ions in aqueous solutions and all three electrodes showed a response to oxalate additions. The peak of oxalate oxidation at BPPG electrode appeared at lower potential, +1.13 V vs. SCE, than at EPPG (+1.20 V vs. SCE) and GC electrode (+1.44 V vs. SCE). Oxalate oxidation at BPPG electrode was studied in more details for response characteristics (potential and current), effects of pH, temporal characteristics of response potential and current. The results indicated that oxalate oxidation proceeds as two‐electron process at the BPPG electrode with a transfer coefficient β and a diffusion coefficient D evaluated to be 0.45 and 1.03 (±0.04)×10?5 cm2 s?1 respectively. The BPPG electrode was found to be suitable for oxalate determination in aqueous media showing linear response to oxalate concentration with a sensitivity of 0.039 AM?1 and a limit of detection of 0.7 μM.  相似文献   

6.
《Electroanalysis》2004,16(10):860-865
The electrocatalytic oxidation of sulfite has been studied on the cobalt pentacyanonitrosylferrate modified glassy carbon electrode (CoPCNF). The CoPCNF films on the glassy carbon electrodes show an excellent electrocatalytic activity toward the oxidation of sulfite in 0.5 M KNO3. The kinetics of the catalytic reaction was investigated by using cyclic voltammetry, rotating disk electrode (RDE) voltammetry and chronoamperometry. The average value of the rate constant, K, for the catalytic reaction and the diffusion coefficient, D, were evaluated by different approaches for sulfite and found to be 2.9×102 M?1s?1 and 4.6×10?6 cm2s?1, respectively. At a fixed potential under hydrodynamic conditions (stirred solutions), the oxidation current is proportional to the sulfite concentration and the calibration plot was linear over the concentration range 5×10?6–1×10?4 M. The detection limit of the method is 3×10?6 M., low enough for the trace sulfite determination.  相似文献   

7.
Banks CE  Compton RG 《The Analyst》2005,130(9):1232-1239
The electrocatalytic properties of multi-walled carbon nanotube modified electrodes toward the oxidation of NADH are critically evaluated. Carbon nanotube modified electrodes are examined and compared with boron-doped diamond and glassy carbon electrodes, and most importantly, edge plane and basal pyrolytic graphite electrodes. It is found that CNT modified electrodes are no more reactive than edge plane pyrolytic graphite electrodes with the comparison with edge plane and basal plane pyrolytic graphite electrodes allowing the electroactive sites for the electrochemical oxidation of NADH to be unambiguously determined as due to edge plane sites. Using these highly reactive edge plane sites, edge plane pyrolytic graphite electrodes are examined with cyclic voltammetry and amperometry for the electroanalytical determination of NADH. It is demonstrated that a detection limit of 5 microM is possible with cyclic voltammetry or 0.3 microM using amperometry suggesting that edge plane pyrolytic graphite electrodes can conveniently replace carbon nanotube modified glassy carbon electrodes for biosensing applications with the relative advantages of reactivity, cost and simplicity of preparation. We advocate the routine use of edge plane and basal plane pyrolytic graphite electrodes in studies utilising carbon nanotubes particularly if 'electrocatalytic' properties are claimed for the latter.  相似文献   

8.
WANG Yuane  PAN Dawei  LI Xinmin  QIN Wei 《中国化学》2009,27(12):2385-2391
A bismuth/multi‐walled carbon nanotube (Bi/MWNT) composite modified electrode for determination of cobalt by differential pulse adsorptive cathodic stripping voltammetry is described. The electrode is fabricated by potentiostatic pre‐plating bismuth film on an MWNT modified glassy carbon (GC) electrode. The Bi/MWNT composite modified electrode exhibits enhanced sensitivity for cobalt detection as compared with the bare GC, MWNT modified and bismuth film electrodes. Numerous key experimental parameters have been examined for optimum analytical performance of the proposed electrode. With an adsorptive accumulation of the Co(II)‐dimethylglyoxime complex at ?0.8 V for 200 s, the reduction peak current is proportional to the concentration of cobalt in the range of 4.0×10?10?1.0×10?7 mol/L with a lower detection limit of 8.1×10?11 mol/L. The proposed method has been applied successfully to cobalt determination in seawater and lake water samples.  相似文献   

9.
《Electroanalysis》2017,29(3):756-764
Direct electro‐oxidation of famotidine at different graphitic carbon‐based electrode materials was evaluated. These materials included conventional electrodes of edge‐plane pyrolytic graphite, basal‐plane pyrolytic graphite, carbon paste, and glassy carbon as well as nano‐structured carbon‐based materials such as pyrolytic carbon film, carbon nanotube, and nano‐graphene. Raman spectroscopy and scanning electron microscopy were employed to analyze their structural and morphological features. It was found that the pyrolytic carbon film electrode, after a simple and fast anodic activation, shows superior electroanalytical performance. The method was successfully applied for the electroanalytical determination of famotidine in tablet dosage forms and urine samples.  相似文献   

10.
A novel and reliable direct electrochemical method has been established to monitor DNA damage in acid hydrolyzed calf thymus DNA, based on the determination of 2,8‐dihydroxyadenine (2,8‐DHA). A single‐wall carbon nanotubes (SWCNT) modified edge plane pyrolytic graphite electrode (EPPGE) has been used as a sensor to monitor the DNA damage. 2,8‐DHA the main in vivo adenine oxidation product undergoes oxidation at ~395 mV at SWCNT modified EPPGE using square wave voltammetry (SWV). The sensor exhibits potent and persistent electron‐mediating behavior. A well‐defined oxidation peak for the oxidation of 2,8‐DHA was observed at modified electrode with lowering of peak potential and increase in peak current as compared to bare EPPGE. At optimal experimental conditions, the catalytic oxidative peak current was responsive with the 2,8‐DHA concentrations ranging from 0.05 nM to 100 nM. The detection limit was 3.8×10?11 M and limit of quantification was 1.27×10?10 M. The modified electrode exhibited high stability and reproducibility.  相似文献   

11.
《Analytical letters》2012,45(7):1341-1357
Ezetimibe is the first of a new class of drugs that selectively inhibits cholesterol absorption in the small intestine and reduces plasma LDL cholesterol. In this study, electrochemical oxidation of ezetimibe was investigated on carbon based electrodes and a single and irreversible peak at both electrodes was observed. A linear response was detected between 2 × 10?6 and 8 × 10?5 M with glassy carbon electrode and between 2 × 10?6 and 2 × 10?4 M with a boron-doped diamond electrode in 0.1 M H2SO4 supporting electrolyte. The proposed methods were successfully applied for the determination of ezetimibe from pharmaceutical dosage forms and human serum samples.  相似文献   

12.
Single‐walled carbon nanotubes(SWCNTs) were dispersed into DMSO, and a SWCNTs‐film coated glassy carbon electrode was achieved via evaporating the solvent. The results indicated that CNT modified glassy carbon electrode exhibited efficiently electrocatalytic reduction for ranitidine and metronidazole with relatively high sensitivity, stability and life time. Under conditions of cyclic voltammetry, the potential for reduction of selected analytes is lowered by approximately 150 mV and current is enhanced significantly (7 times) in comparison to the bare glassy carbon electrode. The electrocatalytic behavior is further exploited as a sensitive detection scheme for these analytes determinations by hydrodynamic amperometry. Under optimized condition in amperometric method the concentration calibration range, detection limit and sensitivity were about, 0.1–200 μM, detection limit (S/N=3) 6.3×10?8 mol L?1 and sensitivity 40 nA/μM for metronidazole and 0.3–270 μM 7.73×10?8 mol L?1 and 25 nA/μM for ranitidine. In addition, the ability of the modified electrode for simultaneous determination of ranitidine and metronidazole was evaluated. The proposed method was successfully applied to ranitidine and metronidazole determination in tablets. The analytical performance of this sensor has been evaluated for detection of these analytes in serum as a real sample.  相似文献   

13.
《Electroanalysis》2004,16(15):1244-1253
This work deals with the study of polymers electrogenerated from different catechols at glassy carbon electrodes and the analytical applications of the resulting modified electrodes for dopamine quantification and glucose biosensing. The electropolymerization was performed from a 3.0×10?3 M catechol solution (catechol, dopamine, norepinephrine, epinephrine or L ‐dopa in a 0.050 M phosphate buffer pH 7.40) by applying 1.00 V for 60 min. The properties of the polymers are very dependent on the nature of the catechol, L ‐dopa being the best. Glassy carbon electrodes modified with melanic polymers electrogenerated from L ‐dopa and norepinephrine were found to be suitable for dopamine determinations in flow systems, although the behavior was highly dependent on the nature of the monomer. Detection limits of 5.0 nM dopamine and interferences of 9.0 and 2.6% for 5.0×10?4 M ascorbic acid and 5.0×10?5 M dopac, respectively, were obtained at the glassy carbon electrode modified with a melanin‐type polymer generated from L ‐dopa (using 1.0×10?3 M AA in the measurement solution). The advantages of using a melanin‐type polymer generated from dopamine to improve the selectivity of glucose biosensors based on carbon paste electrodes containing Pt and glucose oxidase (GOx) are also discussed. The resulting bioelectrodes combines the high sensitivity of metallized electrodes with the selectivity given by the polymeric layer. They exhibit excellent performance for glucose with a rapid response (around 10 seconds per sample), a wide linear range (up to 2.5×10?2 M glucose), low detection limits (143 μM) and a highly reproducible response (R.S.D of 4.9%). The bioelectrodes are highly stable and almost free from the interference of large excess of easily oxidizable compounds found in biological fluids, such as ascorbic acid (AA), uric acid (UA) and acetaminophen.  相似文献   

14.
Acid chrome blue K (ACBK) was electropolymerized on the surface of a glassy carbon electrode (GCE) by cyclic voltammetric sweep in the potential range from –0.2 to 0.9 V. The characteristic of poly‐ACBK film was studied by different methods such as electrochemical impedance spectroscopy (EIS) and cyclic voltammetry. This modified electrode showed excellent electrocatalytic response to curcumin with the increase of the electrochemical responses. Under the optimal conditions a good linear voltammetric response could be obtained over the range of 1.0 × 10?7‐7.0 × 10?5 M and the detection limit was got as 4.1 × 10?8 M (S/N = 3). The method was successfully applied for the determination of curcumin in human urinev samples.  相似文献   

15.
氮掺杂碳纳米管修饰电极的电化学行为   总被引:1,自引:0,他引:1  
董俊萍  曲晓敏  王利军  王田霖 《化学学报》2007,65(21):2405-2410
制备了氮掺杂改性的碳纳米管, 并用循环伏安法(CV)测定了多巴胺(DA)和抗坏血酸(AA)在不同氮含量的碳纳米管修饰电极上的电化学行为. 结果表明, 氮掺杂碳纳米管修饰电极对AA和DA有不同的电催化行为, 其中高氮含量修饰电极对AA的催化作用强, 而低氮含量修饰电极对DA的催化作用强. 微分脉冲伏安法(DPV)的结果显示, DA的氧化峰电流与其浓度在5.0×10-6~2.0×10-4 mol/L范围内呈良好的线性关系, 检出限达1.64×10-6 mol/L (S/N=3); AA氧化峰电流与其浓度在3.0×10-5~1.0×10-2 mol/L范围内呈良好的线性关系, 检出限达3.26×10-6 mol/L (S/N=3). 该修饰电极在AA大量存在(AA浓度为DA浓度两万倍)时可选择性地实现多巴胺的测定而不造成干扰.  相似文献   

16.
《Analytical letters》2012,45(6):976-990
The electrochemical oxidation of riluzole was investigated using cyclic and linear sweep voltammetry. Under optimized conditions, current and concentration showed linear dependence in Britton Robinson buffer at pH 3.00 for boron doped diamond and pH 3.00 phosphate buffers for glassy carbon electrodes. Differential pulse and square wave voltammetry were used for the determination of riluzole levels in serum samples and pharmaceutical formulations. The limit of detections were found as 5.25 × 10?7 M and 8.26 × 10?8 M for glassy carbon electrode and 1.78 × 10?7 M and 8.42 × 10?8 M for boron-doped diamond electrodes, in serum samples, using differential pulse and square wave methods, respectively.  相似文献   

17.
Selective dopamine (DA) determinations using porous‐carbon‐modified glassy carbon electrodes (GCE) in the presence of ascorbic acid (AA) were studied. The effects of structure textures and surface functional groups of the porous carbons on the electrochemical behavior of DA was analyzed based on both cyclic voltammetry (CV) and differential pulse voltammetry (DPV) measurements. The differential pulse voltammetry of DA on the modified GCE was determined in the presence of 400‐fold excess of AA, and the linear determination ranges of 0.05–0.99, 0.20–1.96, and 0.6–12.60 μM with the lowest detected concentrations of 4.5×10?3, 4.4×10?2, and 0.33 μM were obtained on the mesoporous carbon, mesoporous carbon with carboxylic and amino groups modified electrodes, respectively.  相似文献   

18.
In this study, a Tosflex (a perfluoro‐anion‐exchange membrane) modified glassy carbon electrode has been used to detect 2‐naphthalenol (2‐naphthol) in aqueous solutions in order to demonstrate the electroanalytical application of Tosflex. 2‐naphthol polymerizes upon electrochemical oxidation at a glassy carbon electrode; however, the current related to this oxidation is too small for analytical purpose at low concentration level. A Tosflex polymer modified glassy carbon electrode (TFGCE) was found of having capability to improve the detection limit because 2‐naphthol molecules deprotonated in basic solutions to form 2‐naphtholate anions that were accumulated to TFGCE by the anion‐exchange characteristic of Tosflex. The accumulated 2‐naphtholate anions were determined with the following differential pulse voltammetry. With 3 minutes accumulation at +0.05 V, the dependence of oxidation current versus concentration was linear from 8×10?7 M to 1×10?5 M with a regression coefficient of 0.999 and a detection limit of 2×10?7 M. Unlike many other anion‐exchange polymer modified electrodes, the TFGCE is stable at highly basic condition.  相似文献   

19.
A sensitive and selective electrochemical method for the determination of dopamine using a combined electropolymerized permselective film of polytyramine and polypyrrole‐1‐propionic acid on a glassy carbon (GC) electrode was developed. The formation of a “layer‐by‐layer” film has allowed for selective detection of dopamine in the presence of 3,4‐dihydroxyphenylalanine (L‐DOPA), DOPAC, ascorbic acid, uric acid, epinephrine and norepinephrine. The modified electrodes exhibited a detection limit of 100 nM with linearity ranging from 5×10?6 to 5×10?5 M. No cleaning step was required during the course of repeated measurement.  相似文献   

20.
An ionic liquid (i.e., 1‐butyl‐3‐methylimidazolium hexafluorophosphate, BMIMPF6)‐single‐walled carbon nanotube (SWNT) gel modified glassy carbon electrode (BMIMPF6‐SWNT/GCE) is fabricated. At it the voltammetric behavior and determination of p‐nitroaniline (PNA) is explored. PNA can exhibit a sensitive cathodic peak at ?0.70 V (vs. SCE) in pH 7.0 phosphate buffer solution on the electrode, resulting from the irreversible reduction of PNA. Under the optimized conditions, the peak current is linear to PNA concentration over the range of 1.0×10?8–7.0×10?6 M, and the detection limit is 8.0×10?9 M. The electrode can be regenerated by successive potential scan in a blank solution for about 5 times and exhibits good reproducibility. Meanwhile, the feasibility to determine other nitroaromatic compounds (NACs) with the modified electrode is also tested. It is found that the NACs studied (i.e., p‐nitroaniline, p‐nitrophenol, o‐nitrophenol, m‐nitrophenol, p‐nitrobenzoic acid, and nitrobenzene) can all cause sensitive cathodic peaks under the conditions, but their peak potentials and peak currents are different to some extent. Their peak currents and concentrations show linear relationships in concentration ranges with about 3 orders of magnitude. The detection limits are 8.0×10?9 M for p‐nitroaniline, 2.0×10?9 M for p‐nitrophenol, 5.0×10?9 M for o‐nitrophenol, 5.0×10?9 M for m‐nitrophenol, 2.0×10?8 M for p‐nitrobenzoic acid and 8.0×10?9 M for nitrobenzene respectively. The BMIMPF6‐SWNT/GCE is applied to the determination of NACs in lake water.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号