首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Capillary zone electrophoresis coupled with a capacitively coupled contactless conductivity detector (CE‐C4D) has been employed for the determination of atenolol and amiloride in pharmaceutical formulations. Acetic acid (150 mm ) was used as background electrolyte. The influence of several factors (detector excitation voltage and frequency, buffer concentration, applied voltage, capillary temperature and injection time) was studied. Non‐UV‐absorbing L‐valine was used as internal standard; the analytes were all separated in less than 7 min. The separation was carried out in normal polarity mode at 28°C, 25 kV and using hydrodynamic injection (25 s). The separation was effected in an uncoated fused‐silica capillary (75 μm, i.d. × 52 cm). The CE‐C4D method was validated with respect to linearity, limit of detection and quantification, accuracy, precision and selectivity. Calibration curves were linear over the range 5–250 μg/mL for the studied analytes. The relative standard deviations of intra‐ and inter‐day migration times and corrected peak areas were less than 6.0%. The method showed good precision and accuracy and was successfully applied to the simultaneous determination of atenolol and amiloride in different pharmaceutical tablet formulations. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

2.
Antiseptic agent carbethopendecinium bromide (septonex) was determined by capillary electrophoresis with capacitively coupled contactless conductivity detection. Optimal separation of this quaternary ammonium ion was achieved in BGE of pH 7.0 containing 30 mM 2-(N-morpholino)ethanesulfonic acid, 12.5 mg/mL of 2-hydroxypropyl-β-cyclodextrin and 20% v/v of acetonitrile. The separation was performed at 25°C in an uncoated fused silica capillary (50 μm id; total length, 60.5 cm; effective length, 50 cm) at 30 kV. Samples were injected hydrodynamically at 50 mbar for 6 s. For quantitative analysis, L-arginine (500 μg/mL) was used as internal standard. The calibration curve was rectilinear for 25-400 μg/mL of septonex (y=0.0113x-0.0063; r(2)=0.9992). The LOD was 7 μg/mL of septonex (at S/N=3). The run-to-run repeatability (n=6) was characterized by the RSDs of 0.18% for the migration time and 1.96% for the analyte/internal standard peak area ratio. Accuracy tested by recovery experiments at three concentration levels gave recoveries of 100.27-104.22% with RSD ≤2.19%. The method was successfully applied to the assay of carbethopendecinium bromide in eye drops. Quaternary ammonium ions having structure and size close to that of carbethopendecinium may not be resolved from the analyte.  相似文献   

3.
A novel capillary electrophoretic method for the separation of pancuronium (PM) and vecuronium (VM) ions utilizing capacitively coupled contactless conductivity detection was devised and validated. The separation was carried out in bare fused-silica capillaries (50 μm id, 75/45 cm) at 25°C. Optimal BGE was 50 mM borate buffer of pH 9.5 containing 12.5 mg/mL of (2-hydoxypropyl)-γ-CD. The samples were injected hydrodynamically at 1000 mbar for 3 s. Separation was performed at +30 kV. Under such conditions the PM and VM were base-line resolved and the separation took < 4 min. For quantification phenyltrimethylammonium iodide was used as internal standard. Calibration curves were linear for both pancuronium bromide (PMB) and vecuronium bromide (VMB) in the range 25-250 μg/mL with r> 0.9968. The limits of detection were 7 and 6?μg/mL for PMB and VMB, respectively. The accuracy tested by recovery experiment at three concentration levels of added PMB and VMB was satisfactory (95.7-102.7%, n =3, with RSD < 2.61%). The method was successfully applied to the assay of PMB and VMB in commercial injection solutions.  相似文献   

4.
Cation‐selective exhaustive injection and sweeping followed by a MEKC separation is evaluated for the sensitive analysis of 5‐nitroimidazoles in untreated human serum and urine. Deproteinized serum and urine samples were diluted 76 and 143 times, respectively, in a low‐conductivity solvent (5.00 mM orthophosphoric acid containing 5.0% v/v methanol). Samples were electrokinetically injected at 9.8 kV for 632 s in a previously conditioned fused‐silica capillary (65.0 cm × 50 μm id). Separation was performed at –30 kV and 20°C using 44 mM phosphate buffer (pH 2.5), 123 mM SDS, and 8% v/v tetrahydrofurane as BGE. Signals were monitored at 276 nm and peak area was selected as analytical response. Good linearity (R2 ≥ 0.988) and LODs lower than 1.5 and 1.8 μg/mL were achieved in serum and urine, respectively.  相似文献   

5.
A high‐speed CE system for multiple samples was developed based on a short capillary and an automated sample introduction device consisting of a commercial multi‐well plate and an x‐y‐z translation stage. The spontaneous injection method was used to achieve picoliter‐scale sample injection from different sample wells. Under the optimized conditions, a 40 μm‐long sample plug (corresponding to 78‐pL plug volume) was obtained in a 50 μm id capillary, which ensured both the high separation speed and high separation efficiency. The performance of the system was demonstrated in the separation of FITC‐labeled amino acids with LIF detection. Five FITC‐labeled amino acids including arginine, phenylalanine, glycine, glutamic acid, and asparagine were separated within 15 s with an effective separation length of 1.5 cm. The separation efficiency ranged from 7.96 × 105/m to 1.12 × 106 /m (corresponding to 1.26–0.89 μm plate heights). The repeatability of the peak heights calibrated with an inner standard for different sample wells was 2.4 and 2.7% (n = 20) for arginine and phenylalanine, respectively. The present system was also applied in consecutive separations of 20 different samples of FITC‐labeled amino acids with a whole separation time of less than 6 min.  相似文献   

6.
A novel capillary zone electrophoresis separation coupled to electro spray ionization time‐of‐flight mass spectrometry method was developed for the simultaneous analysis of six toxic alkaloids: brucine, strychnine, atropine sulfate, anisodamine hydrobromide, scopolamine hydrobromide and anisodine hydrobromide in human plasma and urine. To obtain optimal sensitivity, a solid‐phase extraction method using Oasis MCX cartridges (1 mL, 30 mg; Waters, USA) for the pretreatment of samples was used. All compounds were separated by capillary zone electrophoresis at 25 kV within 12 min in an uncoated fused‐silica capillary of 75 μm id × 100 cm and were detected by time‐of‐flight mass spectrometry. This method was validated with regard to precision, accuracy, sensitivity, linear range, limit of detection (LOD), and limit of quantification (LOQ). In the plasma and urine samples, the linear calibration curves were obtained over the range of 0.50–100 ng/mL. The LOD and LOQ were 0.2–0.5 ng/mL and 0.5–1.0 ng/mL, respectively. The intra‐ and interday precision was better than 12% and 13%, respectively. Electrophoretic peaks could be identified by mass analysis.  相似文献   

7.
Jasmonic acid (JA) conjugates with amino acids (AAs) are a group of plant hormone in the family of jasmonates. The separation of stereoisomers of JA‐AA conjugates is a very challenging work since these stereoisomers have similar chromatographic and electrophoretic behavior. Simultaneous separation of ten (±)‐JA conjugates with five AAs including l‐ Tyr (tyrosine), l‐ leucine, l‐ Ile (isoleucine), l‐ valine, and l‐ phenylalanine and their stereoisomers has been achieved by MEKC with diode array detector in this work. Optimum separation of the analytes was obtained on a 61.5 cm × 75 μm id capillary using a running buffer containing 80 mM SDS and 50 mM phosphates (pH 7.0) at +18 kV applied voltage and capillary temperature of 35°C. Ten stereoisomers of JA conjugates with five AAs are completely separated in 13 min. The RSDs of the migration times and peak areas of the ten stereoisomers were in the range of 0.48–1.03% and 1.03–2.07%, respectively. In the tested concentration range, good linear relationships (correlation coefficients above 99%) between peak areas and concentrations of the analytes were observed. The proposed method has been successfully applied to the analysis of spiked rice floret sample and original reaction solution of (±)‐JA‐Ile conjugate and (±)‐JA‐Tyr conjugate. The recoveries ranged from 91.7 to 107.6% for the rice floret sample and 92.9 to 107.2% for the original reaction solution.  相似文献   

8.
In capillary electrochromatography (CEC), magnetic particles (MPs) were packed in a fused silica capillary by using the magnetic field to be retained without frits. For a chiral CEC separation, avidin was immobilized onto the surface of the MPs (AVI-MPs) as a stationary phase by using the physical adsorption technique. The injected AVI-MPs into the capillary were stably captured with the magnet (surface magnetic flux density, 250 mT) under the separation voltage of 10 kV (190 V/cm). By employing the fritless AVI-MPs packed capillary, the chiral separation of ketoprofen was successfully attained with the packing length of only 5 cm. Effects of the modification condition of avidin, pH of background solution, and the packing length on the enantioseparation were also investigated. Under the optimal condition, furthermore, the repeatability for the retention time of ketoprofen was better than 1.5% in the relative standard deviation and the capillary-to-capillary reproducibility was also acceptable in the prepared fritless capillaries.  相似文献   

9.
Liu H  Han N  Zhang L  Du Y  Zhang W 《Analytica chimica acta》2010,680(1-2):48-53
A dynamic coating capillary electrophoresis coupled with a simplified on-line chemiluminescence detection system was designed and evaluated. In the proposed system, poly-vinylpyrrolidone was used as dynamic coating substance in the separation buffer to reduce the unwanted protein non-specific adsorption, which was first applied in capillary electrophoresis coupling with on-line chemiluminescence detection. In order to avoid complex processing, an ordinary plastic cuvette was modified as a three-way joint. The chemiluminescence reaction conditions and capillary electrophoresis separation conditions were investigated in detail. The results showed that the coated capillary can be injected protein samples at least 30 times continuously with good repeatability. Under optimal conditions, the chemiluminescence relative intensity was linear with the concentration of hemoglobin in the range of 4-1850 μg mL(-1) and the detection limit was 2.0 μg mL(-1) (S/N=3). The relative standard deviation of migration times and peak heights for 40 μg mL(-1) hemoglobin were 2.5% and 4.1% (n=11) respectively. Interference of matrix effects was overcome by the calibration according to standard addition methods. Afterwards, the method was validated successfully and was applied to detect the concentration of hemoglobin in the serum of haemolytic patients.  相似文献   

10.
A micellar electrokinetic chromatography (MEKC) method for the simultaneous determination of the antiviral drugs acyclovir and valacyclovir and their major impurity, guanine, was developed. The influences of several factors (surfactant and buffer concentration, pH, applied voltage, capillary temperature and injection time) were studied. Using tyramine hydrochloride as internal standard, the analytes were all separated in about 4 min. The separation was carried out in reversed polarity mode at 28°C, 25 kV and using hydrodynamic injection (15 s). The separation was effected in a fused‐silica capillary 100 μm × 56 cm and a background electrolyte of 20 mM citric acid–1 M Tris solution (pH 2.75), containing 125 mM sodium dodecyl sulphate and detection at 254 nm. The method was validated with respect to linearity, limit of detection and quantification, accuracy, precision and selectivity. Calibration curves were linear over the range 0.1–1 μg/mL (guanine) and from 0.1 to 120 μg/mL for both valacyclovir and acyclovir. The relative standard deviations of intra‐ and inter‐day migration times and corrected peak areas were less than 5.0%. The proposed method was successfully applied to the determination of the analytes in tablets and creams. From the previous study it is concluded that the stability‐indicating method developed for acyclovir and valacyclovir can be used for analysis of the drug in various stability samples. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
Capillary zone electrophoresis methods for the simultaneous determination of the β‐blocker drugs, atenolol, chlorthalidone and amiloride, in pharmaceutical formulations have been developed. The influences of several factors (buffer pH, concentration, applied voltage, capillary temperature and injection time) were studied. Using phenobarbital as internal standard, the analytes were all separated in less than 4 min. The separation was carried out in normal polarity mode at 25°C, 25 kV and using hydrodynamic injection (10 s). The separation was effected in an uncoated fused‐silica capillary (75 μm i.d. × 52 cm) and a background electrolyte of 25 mm H3PO4 adjusted with 1 m NaOH solution (pH 9.0) and detection at 198 nm. The method was validated with respect to linearity, limit of detection and quantification, accuracy, precision and selectivity. Calibration curves were linear over the range 1–250 μg/mL for atenolol and chlorthalidone and from 2.5–250 μg/mL for amiloride. The relative standard deviations of intra‐ and inter‐day migration times and corrected peak areas were less than 6.0%. The method showed good precision and accuracy and was successfully applied to the simultaneous determination of atenolol, chlorthalidone and amiloride in various pharmaceutical tablets formulations. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
基于稀土Eu(Ⅲ)掺杂的类普鲁士蓝膜修饰的铂电极为工作电极,建立了测定羟考酮的毛细管电泳-电致化学发光分析方法。考察了检测电位、运行缓冲溶液的酸度及浓度、分离电压、进样条件等对电泳分离效果及检测灵敏度的影响。在最佳的实验条件下,羟考酮可在4 min内得到分离,其ECL强度值与羟考酮的质量浓度在7.0×10-2~7.0μg/mL和7.0~70.0μg/mL范围内呈良好的线性关系,检出限为4.2×10-2μg/mL(3σ),峰高和迁移时间的相对偏差分别为3.6%和0.48%(n=6)。方法用于兔血浆中羟考酮含量的检测,加标回收率在99.7%~101.0%之间。  相似文献   

13.
A novel, simple and sensitive method for the enantioseparation and determination of DL ‐tetrahydropalmatine (DL ‐THP) was developed using ACE in combination with partial filling technique and field‐amplified sample injection. A chiral selector, i.e. BSA, was used for the enantioseparation of DL ‐THP in ACE. Effects of BSA concentration, pH and separation voltage on the effectiveness of the enantiomer separation were evaluated. In an optimal condition, D ‐ and L ‐THP were completely enantio‐separated in less than 9 min by partially filling an electrophoretic capillary with 50 μmol/L BSA (50 mbar, 100 s) and carrying out an electrophoresis with 20 mmol/L phosphate buffer (pH 7.4) at 15 kV. The sensitivity was further improved by making use of field‐amplified sample injection to lower the LOD (defined as S/N=3) down to 6 ng/mL. Real samples were also tested and promising results for the determination of DL ‐THP enantiomers were obtained.  相似文献   

14.
Novel CE methods have been developed on portable instrumentation adapted to accommodate a capacitively coupled contactless conductivity detector for the separation and sensitive detection of inorganic anions and cations in post‐blast explosive residues from homemade inorganic explosive devices. The methods presented combine sensitivity and speed of analysis for the wide range of inorganic ions used in this study. Separate methods were employed for the separation of anions and cations. The anion separation method utilised a low conductivity 70 mM Tris/70 mM CHES aqueous electrolyte (pH 8.6) with a 90 cm capillary coated with hexadimethrine bromide to reverse the EOF. Fifteen anions could be baseline separated in 7 min with detection limits in the range 27–240 μg/L. A selection of ten anions deemed most important in this application could be separated in 45 s on a shorter capillary (30.6 cm) using the same electrolyte. The cation separation method was performed on a 73 cm length of fused‐silica capillary using an electrolyte system composed of 10 mM histidine and 50 mM acetic acid, at pH 4.2. The addition of the complexants, 1 mM hydroxyisobutyric acid and 0.7 mM 18‐crown‐6 ether, enhanced selectivity and allowed the separation of eleven inorganic cations in under 7 min with detection limits in the range 31–240 μg/L. The developed methods were successfully field tested on post‐blast residues obtained from the controlled detonation of homemade explosive devices. Results were verified using ion chromatographic analyses of the same samples.  相似文献   

15.
The use of CE with contactless conductivity detection for the determination of PCR products is demonstrated for the first time. The separation of specific length PCR products according to their size could be achieved using 5% PVP as a sieving medium in a separation buffer consisting of 20 mM Tris and 20 mM 2‐(cyclohexylamino)ethansulphonic acid (pH 8.5). A fused silica capillary of 60 cm length and 50 μm id and an applied separation voltage of –15 kV were employed and separations could be completed within 20–50 min. PCR amplified DNA fragments of different sizes obtained from different bacterial plasmid templates as well as a fragment from genomic DNA of genetically modified soybeans could be successfully identified.  相似文献   

16.
Zhang Y  Lee HK  Li SF 《Talanta》1998,45(4):613-618
Fast, efficient separation of five free acid forms of porphyrins was achieved in a short capillary and a chip, respectively. The capillary was 6 cm long from injection end to detector with an electric field strength of 214 V cm(-1). Separations were performed within 5 min. A glass microchip device was fabricated using standard photolithographic procedures and chemical wet etching. The channels were sealed using a direct bonding technique. For a separation length of 2.8 cm with electric field strength of 500 V cm(-1), electrophoretic separations with baseline resolution were achieved in less than 2 min. A variable wavelength epi-fluorescence microscope was used as an on-column detector.  相似文献   

17.
Amikacin is a semisynthetic aminoglycoside antibiotic derived from kanamycin A that lacks a strong UV absorbing chromophore or fluorophore. Due to the physicochemical properties of amikacin and its related substances, CE in combination with capacitively coupled contactless conductivity detection (CE-C(4) D) was chosen. The optimized separation method uses a BGE composed of 20 mM MES adjusted to pH 6.6 by l-histidine and 0.3 mM CTAB that was added as flow modifier in a concentration below the CMC. Ammonium acetate 20 mg.L(-1) was used as internal standard. 30 kV was applied in reverse polarity on a fused silica capillary (73/48 cm; 75 μm id). The optimized separation was obtained in less than 6 min with good linearity (R(2) = 0.9996) for amikacin base. It shows a good precision expressed as RSD on relative peak areas equal to 0.1 and 0.7% for intraday and interday, respectively. The LOD and LOQ are 0.5 mg.L(-1) and 1.7 mg.L(-1) , respectively.  相似文献   

18.
A dual‐selector system employing achiral crown ethers in combination with cyclodextrins has been developed for the separation of peptide diastereomers that contain methionine sulfoxide. The combinations of the crown ethers 15‐crown‐5, 18‐crown‐6, Kryptofix® 21 and Kryptofix® 22 and β‐cyclodextrin, carboxymethyl‐β‐cyclodextrin, and sulfated β‐cyclodextrin were screened at pH 2.5 and pH 8.0 using a 40/50.2 cm, 50 μm id fused‐silica capillary and a separation voltage of 25 kV. No diastereomer separation was observed in the sole presence of crown ethers, while only sulfated β‐cyclodextrin was able to resolve some peptide diastereomers at pH 8.0. Depending on the amino acid sequence of the peptide and the applied cyclodextrin, the addition of crown ethers, especially the Krpytofix® diaza‐crown ethers, resulted in significantly enhanced chiral recognition. Keeping one selector of the dual system constant, increasing concentrations of the second selector resulted in increased peak resolution and analyte migration time for peptide‐crown ether‐cyclodextrin combinations. The simultaneous diastereomer separation of three structurally related peptides was achieved using the dual selector system.  相似文献   

19.
A method was developed to determine simultaneously kanamycin, its related substances and sulphate in kanamycin sulphate using capacitively coupled contactless conductivity detection. Kanamycin is an aminoglycoside antibiotic that lacks a strong UV-absorbing chromophore. Due to its physicochemical properties, CE in combination with capacitively coupled contactless conductivity detection was chosen. The separation method uses a BGE composed of 40 mM 2-(N-morpholino)ethanesulphonic acid monohydrate and 40 mM L-histidine, pH 6.35. A 0.6 mM N-cetyltrimethyl ammonium bromide (CTAB) solution was added as electroosmotic flow modifier in a concentration below the critical micellar concentration (CMC). Ammonium acetate 50 mg/L was used as internal standard. In total, 30 kV was applied in reverse polarity on a fused-silica capillary (65/41 cm; 75 μm id). The optimized separation was obtained in less than 6 min with good linearity (R(2)=0.9999) for kanamycin. It shows a good precision expressed as RSD on the relative peak areas equal to 0.3 and 1.1% for intra-day and inter-day precision, respectively. The LOD and LOQ are 0.7 and 2.3 mg/L, respectively. Similarly, for sulphate, a good linearity (R(2)=0.9996) and precision (RSD 0.4 and 0.6% for intra-day and inter-day, respectively) were obtained.  相似文献   

20.
A novel single‐isomer cyclodextrin derivative, heptakis {2,6‐di‐O‐[3‐(1,3‐dicarboxyl propylamino)‐2‐hydroxypropyl]}‐β‐cyclodextrin (glutamic acid‐β‐cyclodextrin) was synthesized and used as a chiral selector in capillary electrophoresis for the enantioseparation of 12 basic drugs, including terbutaline, clorprenaline, tulobuterol, clenbuterol, procaterol, carvedilol, econazole, miconazole, homatropine methyl bromide, brompheniramine, chlorpheniramine and pheniramine. The primary factors affecting separation efficiency, which include the background electrolyte pH, the concentration of glutamic acid‐β‐cyclodextrin and phosphate buffer concentration, were investigated. Satisfactory enantioseparations were obtained using an uncoated fused‐silica capillary of 50 cm (effective length 40 cm) × 50 μm id with 120 mM phosphate buffer (pH 2.5–4.0) containing 0.5–4.5 mM glutamic acid‐β‐cyclodextrin as background electrolyte. A voltage of 20 kV was applied and the capillary temperature was kept at 20°C. The results proved that glutamic acid‐β‐cyclodextrin was an effective chiral selector for studied 12 basic drugs. Moreover, the possible chiral recognition mechanism of brompheniramine, chlorpheniramine and pheniramine on glutamic acid‐β‐cyclodextrin was investigated using the semi‐empirical Parametric Method 3.  相似文献   