首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A cathodically pretreated boron‐doped diamond electrode was used for the simultaneous anodic determination of ascorbic acid (AA) and caffeine (CAF) by differential pulse voltammetry. Linear calibration curves (r=0.999) were obtained from 1.9×10?5 to 2.1×10?4 mol L?1 for AA and from 9.7×10?6 to 1.1×10?4 mol L?1 for CAF, with detection limits of 19 μmol L?1 and 7.0 μmol L?1, respectively. This method was successfully applied for the determination of AA and CAF in pharmaceutical formulations, with results equal to those obtained using a HPLC reference method.  相似文献   

2.
Voltammetric methods for estrone determination were developed using a cathodically pretreated BDD electrode with DPV or SWV. Analytical curves were obtained for estrone concentrations from 0.20 or 0.10 to 2.0 µmol L?1, for DPV or SWV, with detection limits of 0.20 and 0.10 µmol L?1, respectively. The SWV method was successfully applied in estrone recovery studies in different water matrices. Additionally, these recovery results were reasonably similar to those attained using HPLC/UV‐vis. Comparatively to other electroanalytical methods based on different carbon electrodes, the here‐reported novel methods yield very good results, being adequate for estrone determination in environmental samples.  相似文献   

3.
The electrochemical oxidation of promethazine hydrochloride was made on highly boron‐doped diamond electrodes. Cyclic voltammetry experiments showed that the oxidation mechanisms involved the formation of an adsorbed product that is more readily oxidized, producing a new peak with lower potential values whose intensity can be increased by applying the accumulation potential for given times. The parameters were optimized and the highest current intensities were obtained by applying +0.78 V for 30 seconds. The square‐wave adsorptive voltammetry results obtained in BR buffer showed two well‐defined peaks, dependent on the pH and on the voltammetric parameters. The best responses were obtained at pH 4.0, frequency of 50 s?1, step of 2 mV, and amplitude of 50 mV. Under these conditions, linear responses were obtained for concentrations from 5.96×10?7 to 4.76×10?6 mol L?1, and calculated detection limits of 2.66×10?8 mol L?1 (8.51 μg L?1) for peak 1 and of 4.61×10?8 mol L?1 (14.77 μg L?1) for peak 2. The precision and accuracy were evaluated by repeatability and reproducibility experiments, which yielded values of less than 5.00% for both voltammetric peaks. The applicability of this procedure was tested on commercial formulations of promethazine hydrochloride by observing the stability, specificity, recovery and precision of the procedure in complex samples. All results obtained were compared to recommended procedure by British Pharmacopeia. The voltammetric results indicate that the proposed procedure is stable and sensitive, with good reproducibility even when the accumulation steps involve short times. It is therefore very suitable for the development of the electroanalytical procedure, providing adequate sensitivity and a reliable method.  相似文献   

4.
The electrochemical methods cyclic and square‐wave voltammetry were applied to develop an electroanalytical procedure for the determination of N‐nitrosamines (N‐nitrosopyrrolidine, N‐nitrosopiperidine and N‐nitrosodiethylamine) in aqueous solutions. Cyclic voltammetry was used to evaluate the electrochemical behaviors of N‐nitrosamines on boron‐doped diamond electrodes. It was observed an irreversible electrooxidation peak located in approximately 1.8 V (vs. Ag/AgCl) for both N‐nitrosamines. The optimal electrochemical response was obtained using the following square‐wave voltammetry parameters: f=250 Hz, Esw=50 mV and Es=2 mV using a Britton–Robinson buffer solution as electrolyte (pH 2). The detection and quantification limits determined for total N‐nitrosamines were 6.0×10?8 and 2.0×10?7 mol L?1, respectively.  相似文献   

5.
This work presents a simple, fast and low‐cost method for simultaneous determination of acetylsalicylic acid (ASA), without alkaline hydrolysis and caffeine (CF) in pharmaceutical formulations using a boron‐doped diamond as the working electrode through differential pulse voltammetry. A good repeatability was reached for 20 measurements, with a low relative standard deviation of less than 1.0 %. The calibration curves presented a great linear correlation coefficient for both drugs (R=0.999) with a limit of detection of 1.6×10?7 mol L?1 for CF and 2.3×10?7 mol L?1 for ASA. The system was validated in comparison with the official method.  相似文献   

6.
《Electroanalysis》2005,17(11):925-932
The electrooxidation of naproxen was studied, for the first time, using boron‐doped diamond (BDD) electrode by cyclic and differential pulse voltammetry (CV and DPV) in nonaqueous solvent supporting electrolyte system. The results were also compared with glassy carbon electrode (GC) under the same conditions. Naproxen undergoes one electron transfer resulting in the formation of cation radical for the first electrooxidation step, which follows other chemical and electrochemical steps such as deprotonation, removal of another electron and the attack of nucleophile (ECEC mechanism). BDD electrode provided higher signal to background ratio, well resolved and highly reproducible cyclic voltammograms than the GC electrode. With a scan rate of 50 mV s?1 and pulse height of 50 ms, respectively, the DPV technique was able to determine the naproxen concentrations in the range of 0.5 to 50 μM with a detection limit of 30 nM. The influence of interference compounds namely 2‐acetyl‐6‐methoxy naphthalene (AMN) on naproxen oxidation can also be followed successfully. Moreover, the percentage of AMN present in the standard chemical form of a mixture containing naproxen can be found accurately. Rapidity, precise and good selectivity were also found for the determination of naproxen in pharmaceutical formulations.  相似文献   

7.
A new electroanalytical procedure was developed for the determination of lidocaine in commercial local anesthetics products containing lidocaine as the active ingredient. The procedure is based on the use of electrochemical methods as cyclic and square‐wave voltammetry, with boron‐doped diamond electrodes. The oxidation of lidocaine in Britton–Robinson buffer (0.1 mol L?1) using this type of electrode gives rise to one irreversible peak in 1.68 V (versus Ag/AgCl). The detection and quantification limits obtained from pure water were 10.0 and 34.4 μg/L, respectively. The proposed electrochemical method was also successfully applied to the analysis of commercially available pharmaceutical preparations. The electrochemical responses of pharmaceutical preparations (gels) were identical to those of standard lidocaine. No influence of propyleneglycol present in the gels on the voltammetric responses was observed. Lidocaine recoveries ranged from 97.6% to 99.2%.  相似文献   

8.
《Electroanalysis》2017,29(7):1691-1699
The simultaneous voltammetric determination of melatonin (MT) and pyridoxine (PY) has been carried out at a cathodically pretreated boron‐doped diamond electrode. By using cyclic voltammetry, a separation of the oxidation peak potentials of both compounds present in mixture was about 0.47 V in Britton‐Robinson buffer, pH 2. The results obtained by square‐wave voltammetry allowed a method to be developed for determination of MT and PY simultaneously in the ranges 1–100 μg mL−1 (4.3×10−6–4.3×10−4 mol L−1) and 10–175 μg mL−1 (4.9×10−5–8.5×10−4 mol L−1), with detection limits of 0.14 μg mL−1 (6.0×10−7 mol L−1) and 1.35 μg mL−1 (6.6×10−6 mol L−1), respectively. The proposed method was successfully to the dietary supplements samples containing these compounds for health‐caring purposes.  相似文献   

9.
An electrochemical method for the simultaneous determination of benzene, toluene and xylenes (BTX) in water was developed using square‐wave voltammetry (SWV). The determination of BTX was carried out using a cathodically pre‐treated boron‐doped diamond electrode (BDD) using 0.1 mol L?1 H2SO4 as supporting electrolyte. In the SWV measurements using the BDD, the oxidation peak potentials of the total xylenes‐toluene and toluene‐benzene couples, present in ternary mixtures, display separations of about 100 and 200 mV, respectively. The attained detection limits for the simultaneous determination of benzene, toluene and total xylenes were 3.0×10?7, 8.0×10?7 and 9.1×10?7 mol L?1, respectively. The recovery values taken in ternary mixtures of benzene, toluene and total xylenes in aqueous solutions are 98.9 %, 99.2 % and 99.4 %, respectively.  相似文献   

10.
《Electroanalysis》2006,18(8):830-834
A facile method for the simultaneous measurement of tryptophan (Trp) and tyrosine (Tyr) was firstly exploited at unmodified boron‐doped diamond (BDD) electrode. The experimental results indicated that by using differential pulse voltammetry, the oxidative peaks of these two kinds of amino acids could be completely separated at BDD electrode. The peak separation of Trp and Tyr was developed to be 0.64 V when Na2PO4/NaOH buffer solution with the optimized pH 11.2 was employed. The detection limit of Trp was obtained to be 1×10?5 M, while that of Tyr was achieved to be 1×10?6 M. The present method was also evidenced to be available to the determination of real samples of amino acids.  相似文献   

11.
The performance of hydrogen‐ (HT) and oxygen‐terminated (OT) boron‐doped diamond (BDD) electrodes (electrochemically pretreated) on the simultaneous differential pulse voltammetric determination of sulfamethoxazole and trimethoprim in pharmaceutical products is presented. Under the optimum analytical experimental conditions, the HT‐BDD electrode presented two well‐defined oxidation peaks at 920 and 1100 mV vs. Ag/AgCl for sulfamethoxazole and trimethoprim, respectively. On the other hand, when the OT‐BDD electrode was used, the sulfamethoxazole oxidation current peak was decreased twenty fold. The calculated LOD values for sulfamethoxazole and trimethoprim using the HT‐BDD electrode were 3.65 μg L?1 and 3.92 μg L?1, respectively. The results obtained in the simultaneous determination of sulfamethoxazole and trimethoprim in three different commercial formulations were similar to those obtained using a standard HPLC method at 95% confidence level.  相似文献   

12.
Rapid liquid chromatographic procedures are proposed for analysis of paracetamol and orphenadrine citrate in pharmaceutical preparations and human serum using acetonitrile: water (50:50) as a mobile phase, adjusting pH to 2.6, UV detection at 215 nm and propylparaben sodium as internal standard. The advantages of this method include good and rapid separation, well resolved peaks, and only a small amount of sample is required for assay and adequate precision. The method showed good linearity in the range of 6 to 10000 ng/mL for paracetamol serum concentrations with a correlation coefficient 0.9999 (inter and intra day CV < 3.15) and in the range 3–10000 ng/mL for orphenadrine citrate serum concentrations with a correlation coefficient of 0.9999 (inter and intra day CV < 3.58). The recovery of paracetamol and orphenadrine citrate was > 96.9% and > 96.7%, respectively. The proposed method may be used for the quantitative analysis of paracetamol and orphenadrine citrate alone or in combination from raw materials, in bulk drugs, dosage formulations and in serum.  相似文献   

13.
A simple, rapid and feasible method is developed for direct and simultaneous determination of phenol (Ph), hydroquinone (HQ) and 4‐nitrophenol (4‐NP) on unmodified boron‐doped diamond (BDD) electrode. Results showed that the oxidative peaks of these three phenolic compounds can be completely separated on BDD electrode in acidic conditions by using electrochemical cyclic voltammetry technique. The peak potential separations are all higher than 0.35 V. Moreover, BDD electrode is extremely easy to be refreshed to obtain current values with good reproducibility, even if it is passivated by phenolic compounds with different adsorption characteristics. All the above features are on account of the outstanding electrochemical characteristics of BDD electrode, and lead to the advantage and feasibility for simultaneous determination of three phenolic compounds without any other separation operation. For each tested phenolic compound, the concentration range with linearity is in two or three orders of magnitude in the presence of other coexisting phenolic compounds with the concentrations more than 1000 times higher than that of the tested component. The present method is also shown to be promising for the determination of phenolic contaminants in the real wastewater samples.  相似文献   

14.
The highly boron‐doped diamond electrode (HBDD) combined with square wave voltammetry (SWV) was used in the development of an analytical procedure for diquat determination in potato and sugar cane samples and lemon, orange, tangerine and pineapple juices. Preliminary experiments realised in a medium of 0.05 mol L?1 Na2B4O7 showed the presence of two voltammetric peaks around ?0.6 V and around ?1.0 V vs. Ag/AgCl/Cl? 3.0 mol L?1, where the first peak could be successfully used for analytical proposes due the facility in the electrode surface renovation. After the experimental and voltammetric optimisation, the calculated detection and quantification limits were 1.6×10?10 mol L?1 and 5.3×10?10 mol L?1 (0.057 µg L?1 and 0.192 µg L?1, respectively), which are lower than the maximum residue limit established for fresh food samples by the Brazilian Sanitary Vigilance Agency. The proposed methodology was used to determine diquat residues in potato and sugar cane samples and lemon, orange, tangerine and pineapple juices and the calculated recovery efficiencies indicated that the proposed procedure presents higher robustness, stability and sensitivity, good reproducibility, and is very adequate for diquat determination in complex samples.  相似文献   

15.
《Electroanalysis》2006,18(10):1028-1034
This paper presents a comparative study on the electrochemical behavior of the flavonoid rutin on a rigid carbon‐polyurethane composite electrode and on a glassy carbon electrode. The electrochemical oxidation reaction of rutin was found to be quasireversible and affected by adsorption on the electrode surface. A square‐wave voltammetric method was developed for determination of rutin in green tea infusion samples using the RCPE electrode and data treatment by a deconvolution procedure. The detection limit achieved in buffered solutions was 7.1×10?9 mol L?1 using the RCPE and 1.7×10?8 mol L?1 using the GC electrode the average reproducibility for five determinations being 3.5%.  相似文献   

16.
In this work, a boron‐doped diamond (BDD) electrode was used for the electroanalytical determination of indole‐3‐acetic acid (IAA) phytohormone by square‐wave voltammetry. IAA yielded a well‐defined voltammetric response at +0.93 V (vs. Ag/AgCl) in Britton–Robinson buffer, pH 2.0. The process could be used to determine IAA in the concentration range of 5.0 to 50.0 µM (n=8, r=0.997), with a detection limit of 1.22 µM. The relative standard deviation of ten measurements was 2.09 % for 20.0 µM IAA. As an example, the practical applicability of BDD electrode was tested with the measurement of IAA in some plant seeds.  相似文献   

17.
The voltammetric behavior of paraquat was investigated at hydroxyapatite‐modified carbon paste electrode HAP‐CPE in K2SO4. A method was developed for the detection of the trace of this herbicide, based on their redox reaction. The reduction peaks of paraquat were observed around ?0.70 V and ?1.00 V (vs. SCE) in square‐wave voltammetry. Experimental conditions were optimized by varying the accumulation time, apatite loading and measuring solution pH. Calibration plots were linear under the optimized parameters over the herbicide's concentration range 8–200×10?7 mol L?1, with a detection and quantification limits about 1.5×10?8 mol L?1 and 6.4 10?8 mol L?1, respectively.  相似文献   

18.
《Analytical letters》2012,45(5):804-813
This paper presents a simultaneous spectrophotometric determination of aspirin, paracetamol, caffeine, and chlorphenamine from commercial pharmaceutical products using principal component regression and partial-least squares regression. The concentration of the training set was established employing a partial factorial calibration design at four levels. Several quality parameters and recovery values obtained on authentic samples illustrated excellent performance characteristics concerning the goodness of fit and the accuracy and precision of prediction. Eight pharmaceutical formulations containing at least two of these four mentioned active ingredients and diverse electuaries were successfully analyzed. The obtained results were also validated by high-performance liquid chromatography.  相似文献   

19.
Yavuz Yardım 《Electroanalysis》2011,23(10):2491-2497
In the present paper, a sensitive electroanalytical methodology for the determination of capsaicin using adsorptive stripping voltammetry (AdSV) at a boron‐doped diamond (BDD) electrode is presented. The voltammetric results indicate that in the presence of sodium dodecylsulfate (SDS) the BDD electrode remarkably enhances the oxidation of capsaicin which leads to an improvement of the peak current with a shift of the peak potential to less negative values. A linear working range of 0.05 to 6.0 µg mL?1 (0.16–20 µM) with a detection limit of 0.012 µg mL?1 (0.034 µM) has been obtained using BDD electrode by AdSV.  相似文献   

20.
An electrochemical study was made of the anodic behavior of sodium diethyldithiocarbamate (DEDTC) using a boron‐doped diamond electrode (BDDE) in sodium sulfate supporting electrolyte. This paper presents a new alternative for the electroanalytical determination of DEDTC in protic media, using cyclic voltammetry or chronoamperometry. Linear plots of current vs. concentration correlated with anodic stepwise oxidation were obtained in delimited potential ranges with very good correlation coefficients.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏