首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Microelectrode arrays are used to sort single fluorescently labeled cells and particles as they flow through a microfluidic channel using dielectrophoresis. Negative dielectrophoresis is used to create a “Dielectrophoretic virtual channel” that runs along the center of the microfluidic channel. By switching the polarity of the electrodes, the virtual channel can be dynamically reconfigured to direct particles along a different path. This is demonstrated by sorting particles into two microfluidic outlets, controlled by an automated system that interprets video data from a color camera and makes complex sorting decisions based on color, intensity, size, and shape. This enables the rejection of particle aggregates and other impurities, and the system is optimized to isolate high purity populations from a heterogeneous sample. Green beads are isolated from an excess of red beads with 100% purity at a rate of up to 0.9 particles per second, in addition application to the sorting of osteosarcoma and human bone marrow cells is evidenced. The extension of Dielectrophoretic Virtual Channels to an arbitrary number of sorting outputs is examined, with design, simulation, and experimental verification of two alternate geometries presented and compared.  相似文献   

2.
Effective methods for rapid sorting of cells according to their viability are critical in T cells based therapies to prevent any risk to patients. In this context, we present a novel microfluidic device that continuously separates viable and non-viable T-cells according to their dielectric properties. A dielectrophoresis (DEP) force is generated by an array of castellated microelectrodes embedded into a microfluidic channel with a single inlet and two outlets; cells subjected to positive DEP forces are drawn toward the electrodes array and leave from the top outlet, those subjected to negative DEP forces are repelled away from the electrodes and leave from the bottom outlet. Computational fluid dynamics is used to predict the device separation efficacy, according to the applied alternative current (AC) frequency, at which the cells move from/to a negative/positive DEP region and the ionic strength of the suspension medium. The model is used to support the design of the operational conditions, confirming a separation efficiency, in terms of purity, of 96% under an applied AC frequency of 1.5 × 10Hz and a flow rate of 20 μl/h. This work represents the first example of effective continuous sorting of viable and non-viable human T-cells in a single-inlet microfluidic chip, paving the way for lab-on-a-chip applications at the point of need.  相似文献   

3.
Park J  Kim B  Choi SK  Hong S  Lee SH  Lee KI 《Lab on a chip》2005,5(11):1264-1270
An efficient 3D-asymmetric microelectrode system for high-throughput was designed and fabricated to enhance sorting sensitivities to the dielectric properties-size, morphology, conductivity, and permittivity-of living cells. The principle of the present system is based on the use of the relative strengths of negative dielectrophoretic and drag forces, as in a conventional 3D-microelectrode system. Whereas the typical 3D-microelectrode system has a constant electric field magnitude due to the constant width of the microelectrodes and a fixed gap between face-to-face microelectrodes, the present 3D-asymmetric microelectrode system has electric fields of continuously varying magnitudes along the transverse direction of a channel owing to the changing widths of the electrodes in the half-circular shaped cross section of the microchannel. Thus, varying dielectric forces are generated, leading to increased sorting sensitivity through differentially induced forces to definitely distinct cell types. Numerical analysis verified the improved sensitivity of the present system for sorting living cells. The feasibility of using the newly fabricated system under experimental conditions was tested by demonstrating that a mixed population of mouse P19 embryonic carcinoma (EC) and red blood cells (RBCs) was effectively sorted to different wells depending on their respective relative physical properties.  相似文献   

4.
Dielectrophoresis (DEP) and flow cytometry are powerful technologies and widely applied in microfluidic systems for handling and measuring cells and particles. Here, we present a novel microchip with a DEP selective filter integrated with two microchip flow cytometers (FCs) for on-line monitoring of cell sorting processes. On the microchip, the DEP filter is integrated in a microfluidic channel network to sort yeast cells by positive DEP. The two FCs detection windows are set upstream and downstream of the DEP filter. When a cell passes through the detection windows, the light scattered by the cell is measured by integrated polymer optical elements (waveguide, lens, and fiber coupler). By comparing the cell counting rates measured by the two FCs, the collection efficiency of the DEP filter can be determined. The chips were used for quantitative determination of the effect of flow rate, applied voltage, conductivity of the sample, and frequency of the electric field on the sorting efficiency. A theoretical model for the capture efficiency was developed and a reasonable agreement with the experimental results observed. Viable and non-viable yeast cells showed different frequency dependencies and were sorted with high efficiency. At 2 MHz, more than 90% of the viable and less than 10% of the non-viable cells were captured on the DEP filter. The presented approach provides quantitative real-time data for sorting a large number of cells and will allow optimization of the conditions for, e.g., collecting cancer cells on a DEP filter while normal cells pass through the system. Furthermore, the microstructure is simple to fabricate and can easily be integrated with other microstructures for lab-on-a-chip applications.  相似文献   

5.
This paper demonstrates the utilization of 3D semispherical shaped microelectrodes for dielectrophoretic manipulation of yeast cells. The semispherical microelectrodes are capable of producing strong electric field gradients, and in turn dielectrophoretic forces across a large area of channel cross‐section. The semispherical shape of microelectrodes avoids the formation of undesired sharp electric fields along the structure and also minimizes the disturbance of the streamlines of nearby passing fluid. The advantage of semispherical microelectrodes over the planar microelectrodes is demonstrated in a series of numerical simulations and proof‐of‐concept experiments aimed toward immobilization of viable yeast cells.  相似文献   

6.
Forbes TP  Forry SP 《Lab on a chip》2012,12(8):1471-1479
Immunomagnetic isolation and magnetophoresis in microfluidics have emerged as viable techniques for the separation, fractionation, and enrichment of rare cells. Here we present the development and characterization of a microfluidic system that incorporates an angled permanent magnet for the lateral magnetophoresis of superparamagnetic beads and labeled cell-bead complexes. A numerical model, based on the relevant transport processes, is developed as a design tool for the demonstration and prediction of magnetophoretic displacement. We employ a dimensionless magnetophoresis parameter to efficiently investigate the design space, gain insight into the physics of the system, and compare results across the vast spectrum of magnetophoretic microfluidic systems. The numerical model and theoretical analysis are experimentally validated by the lateral magnetophoretic deflection of superparamagnetic beads and magnetically labeled breast adenocarcinoma MCF-7 cells in a microfluidic device that incorporates a permanent magnet angled relative to the flow. Through the dimensionless magnetophoresis parameter, the transition between regimes of magnetophoretic action, from hydrodynamically dominated (magnetic deflection) to magnetically dominated (magnetic capture), is experimentally identified. This powerful tool and theoretical framework enables efficient device and experiment design of biologically relevant systems, taking into account their inherent variability and labeling distributions. This analysis identifies the necessary beads, magnet configuration (orientation), magnet type (permanent, ferromagnetic, electromagnet), flow rate, channel geometry, and buffer to achieve the desired level of magnetophoretic deflection or capture.  相似文献   

7.
We present a microfluidic cell-culture chip that enables trapping, cultivation and release of selected individual cells. The chip is fabricated by a simple hybrid glass-SU-8-PDMS approach, which produces a completely transparent microfluidic system amenable to optical inspection. Single cells are trapped in a microfluidic channel using mild suction at defined cell immobilization orifices, where they are cultivated under controlled environmental conditions. Cells of interest can be individually and independently released for further downstream analysis by applying a negative dielectrophoretic force via the respective electrodes located at each immobilization site. The combination of hydrodynamic cell-trapping and dielectrophoretic methods for cell releasing enables highly versatile single-cell manipulation in an array-based format. Computational fluid dynamics simulations were performed to estimate the properties of the system during cell trapping and releasing. Polystyrene beads and yeast cells have been used to investigate and characterize the different functions and to demonstrate biological compatibility and viability of the platform for single-cell applications in research areas such as systems biology.  相似文献   

8.
A microfluidic dielectrophoresis platform consisting of curved microelectrodes was developed and integrated with a Raman spectroscopy system. The electrodes were patterned on a quartz substrate, which has insignificant Raman response, and integrated with a microfluidic channel that was imprinted in poly-dimethylsiloxane (PDMS). We will show that this novel integrated system can be efficiently used for the determination of suspended particle types and the direct mapping of their spatial concentrations. We will also illustrate the system's unique advantages over conventional optical systems. Nanoparticles of tungsten trioxide (WO(3)) and polystyrene were used in the investigations, as they are Raman active and can be homogeneously suspended in water.  相似文献   

9.
Direct transport powered by motor proteins can alleviate the challenges presented by miniaturization of microfluidic systems. There have been several recent attempts to build motor‐protein‐driven transport systems based on simple capturing or transport mechanisms. However, to achieve a multifunctional device for practical applications, a more complex sorting/transport system should be realized. Herein, the proof of concept of a sorting device employing selective capture of distinct target molecules and transport of the sorted molecules to different predefined directions is presented. By combining the bottom‐up functionality of biological systems with the top‐down handling capabilities of micro‐electromechanical systems technology, highly selective molecular recognition and motor‐protein‐based transport is integrated in a microfluidic channel network.  相似文献   

10.
This work explores dielectrophoresis (DEP)‐active hydrophoresis in sorting particles and cells. The device consists of prefocusing region and sorting region with great potential to be integrated into advanced lab‐on‐a‐chip bioanalysis devices. Particles or cells can be focused in the prefocusing region and then sorted in the sorting region. The DEP‐active hydrophoretic sorting is not only based on size but also on dielectric properties of the particles or cells of interest without any labelling. A mixture of 3 and 10 μm particles were sorted and collected from corresponding outlets with high separation efficiency. According to the different dielectric properties of viable and nonviable Chinese Hamster Ovary (CHO) cells at the medium conductivity of 0.03 S/m, the viable CHO cells were focused well and sorted from cell sample with a high purity.  相似文献   

11.
A rapid DNA analysis has been developed based on a fluorescence intensity change of a molecular beacon in a PDMS microfluidic channel. Recently, we reported a new analytical method of DNA hybridization involving a PDMS microfluidic sensor using fluorescence energy transfer (FRET). However, there are some limitations in its application to real DNA samples because the target DNA must be labelled with a suitable fluorescent dye. To resolve this problem, we have developed a new DNA microfluidic sensor using a molecular beacon. By monitoring the change in the restored fluorescence intensity along the channel length, it is possible to rapidly detect any hybridization of the molecular beacon to the target DNA. In this case, the target DNA does not need to be labelled. Our experimental results demonstrate that this microfluidic sensor using a molecular beacon is a promising diagnostic tool for rapid DNA hybridization analysis.  相似文献   

12.
The ability to fabricate microfluidic systems with complex structures and with compatible dimensions between the microfluidics and biological cells have attracted significant attention in the development of microchips for analyzing the biophysical and biochemical functions of cells. Just as cell-based microfluidics have become a versatile tool for biosensing, diagnostics, drug screening and biological research, detector modules for cell-based microfluidics have also undergone major development over the past decade. This review focuses on detection methods commonly used in cell-based microfluidic systems, and provides a general survey and an in-depth look at recent developments in optical and electrochemical detection methods for microfluidic applications for biological systems, particularly cell analysis. Selected examples are used to illustrate applications of these detection systems and their advantages and weaknesses.  相似文献   

13.
So JH  Dickey MD 《Lab on a chip》2011,11(5):905-911
This paper describes the fabrication and characterization of microelectrodes that are inherently aligned with microfluidic channels and in direct contact with the fluid in the channels. Injecting low melting point alloys, such as eutectic gallium indium (EGaIn), into microchannels at room temperature (or just above room temperature) offers a simple way to fabricate microelectrodes. The channels that define the shape and position of the microelectrodes are fabricated simultaneously with other microfluidic channels (i.e., those used to manipulate fluids) in a single step; consequently, all of the components are inherently aligned. In contrast, conventional techniques require multiple fabrication steps and registration (i.e., alignment of the electrodes with the microfluidic channels), which are technically challenging. The distinguishing characteristic of this work is that the electrodes are in direct contact with the fluid in the microfluidic channel, which is useful for a number of applications such as electrophoresis. Periodic posts between the microelectrodes and the microfluidic channel prevent the liquid metal from entering the microfluidic channel during injection. A thin oxide skin that forms rapidly and spontaneously on the surface of the metal stabilizes mechanically the otherwise low viscosity, high surface tension fluid within the channel. Moreover, the injected electrodes vertically span the sidewalls of the channel, which allows for the application of uniform electric field lines throughout the height of the channel and perpendicular to the direction of flow. The electrodes are mechanically stable over operating conditions commonly used in microfluidic applications; the mechanical stability depends on the magnitude of the applied bias, the nature of the bias (DC vs. AC), and the conductivity of the solutions in the microfluidic channel. Electrodes formed using alloys with melting points above room temperature ensure mechanical stability over all of the conditions explored. As a demonstration of their utility, the fluidic electrodes are used for electrohydrodynamic mixing, which requires extremely high electric fields (~10(5) V m(-1)).  相似文献   

14.
This work demonstrates the application of dielectrophoretic (DEP) control of silica nanoparticles to form tuneable optical elements within a microfluidic system. The implementation consisted of a microfluidic channel with an array of curved microelectrodes along its base. Various DEP conditions were investigated at alternating current voltage amplitudes, flow rates and frequencies from 5 to 15 V, 2 to 10 μL/min and 0 to 20 MHz, respectively. The fluid channel was filled with deionized water suspending silica particles with diameters of 230 and 450 nm. Experiments were conducted to demonstrate DEP concentration and deflection of the particles and the impact of these particles distributions on the optical transmission through the fluid channel. Both confinement and scattering of the light were observed depending on the particle dimensions and the parameters of the DEP excitation. The results of this investigation illustrate the feasibility of DEP control in an optofluidic system and represent a significant step toward the dynamic formation of electrically controlled liquid optical waveguides.  相似文献   

15.
This work presents a microfluidic device, which was patterned with (i) microstructures for hydrodynamic capture of single particles and cells, and (ii) multiplexing microelectrodes for selective release via negative dielectrophoretic (nDEP) forces and electrical impedance measurements of immobilized samples. Computational fluid dynamics (CFD) simulations were performed to investigate the fluidic profiles within the microchannels during the hydrodynamic capture of particles and evaluate the performance of single‐cell immobilization. Results showed uniform distributions of velocities and pressure differences across all eight trapping sites. The hydrodynamic net force and the nDEP force acting on a 6 μm sphere were calculated in a 3D model. Polystyrene beads with difference diameters (6, 8, and 10 μm) and budding yeast cells were employed to verify multiple functions of the microfluidic device, including reliable capture and selective nDEP‐release of particles or cells and sensitive electrical impedance measurements of immobilized samples. The size of immobilized beads and the number of captured yeast cells can be discriminated by analyzing impedance signals at 1 MHz. Results also demonstrated that yeast cells can be immobilized at single‐cell resolution by combining the hydrodynamic capture with impedance measurements and nDEP‐release of unwanted samples. Therefore, the microfluidic device integrated with multiplexing microelectrodes potentially offers a versatile, reliable, and precise platform for single‐cell analysis.  相似文献   

16.
Drop-based microfluidic devices for encapsulation of single cells   总被引:3,自引:0,他引:3  
We use microfluidic devices to encapsulate, incubate, and manipulate individual cells in picoliter aqueous drops in a carrier fluid at rates of up to several hundred Hz. We use a modular approach with individual devices for each function, thereby significantly increasing the robustness of our system and making it highly flexible and adaptable to a variety of cell-based assays. The small volumes of the drops enables the concentrations of secreted molecules to rapidly attain detectable levels. We show that single hybridoma cells in 33 pL drops secrete detectable concentrations of antibodies in only 6 h and remain fully viable. These devices hold the promise of developing microfluidic cell cytometers and cell sorters with much greater functionality, allowing assays to be performed on individual cells in their own microenvironment prior to analysis and sorting.  相似文献   

17.
This study presents the dielectrophoretic (DEP) assembly of multi‐walled carbon nanotubes (MWCNTs) between curved microelectrodes for the purpose of trapping polystyrene microparticles within a microfluidic system. Under normal conditions, polystyrene particles exhibit negative DEP behaviour and are repelled from microelectrodes. Interestingly, the addition of MWCNTs to the system alters this situation in two ways: first, they coat the surface of particles and change their dielectric properties to exhibit positive DEP behaviour; second, the assembled MWCNTs are highly conductive and after the deposition serve as extensions to the microelectrodes. They establish an array of nanoelectrodes that initiates from the edge of microelectrodes and grow along the electric field lines. These nanoelectrodes can effectively trap the MWCNT‐coated particles, since they cover a large portion of the microchannel bottom surface and also create a much stronger electric field than the primary microelectrodes as confirmed by our numerical simulations. We will show that the presence of MWCNT significantly changes performance of the system, which is investigated by trapping sample polystyrene particles with plain, COOH and goat anti‐mouse IgG surfaces.  相似文献   

18.
微流控芯片系统在单细胞研究中的应用   总被引:2,自引:0,他引:2  
高健  殷学锋  方肇伦 《化学进展》2004,16(6):975-983
微流控芯片具有网络式通道结构,扩展了在细胞和亚细胞水平进行生命科学研究的能力,为单细胞研究提供了一个新的平台.在微流控芯片通道中,人们利用气压、液压和电压,或利用介电电泳、光学陷阱、行波介电电泳以及磁场等技术,可以操纵细胞通过或驻留在通道内的任意位置,从而使单细胞计数、筛选以及胞内组分分析等操作大大简化.本文对微流控芯片系统在血液流变学、单细胞操纵与计数以及单细胞胞内组分分析中的应用进行了综述,介绍了用于单细胞研究的多种微芯片系统,讨论了芯片上进行单细胞操纵的各种方法  相似文献   

19.
This paper describes the fabrication and characterization of a microfluidic device that utilizes a reservoir-based approach for endothelial cell immobilization and integrated embedded carbon ink microelectrodes for the amperometric detection of extracellular nitric oxide (NO) release. The design utilizes a buffer channel to continuously introduce buffer or a plug of stimulant to the reservoir as well as a separate sampling channel that constantly withdraws buffer from the reservoir and over the microelectrode. A steel pin is used for both the fluidic connection to the sampling channel and to provide a quasi-reference electrode for the carbon ink microelectrode. Characterization of the device was performed using NO standards produced from a NONOate salt. Finally, NO release from a layer of immobilized endothelial cells was monitored and quantified using the system. This system holds promise as a means to electrochemically detect extracellular NO release from endothelial cells in either an array of reservoirs or concurrently with fluorescence-based intracellular NO measurements.  相似文献   

20.
Applicability of polydimethylsiloxane (PDMS) for easy and rapid fabrication of enzyme sensor chips, based on electrochemical detection, is examined. The sensor chip consists of PDMS substrate with a microfluidic channel fabricated in it, and a glass substrate with enzyme-modified microelectrodes. The two substrates are clamped together between plastic plates. The sensor chip has shown no leakage around the microelectrodes under continuous solution flow (34 μl/min). Amperometric response of the sensor chips developed in this work suggest that various types of enzyme sensors can be designed by using PDMS microfluidic channels.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号