《Analytical letters》2012,45(8):1229-1240
Polyaniline (PANI) conducting polymers have attracted increasing interest as a transducer material for biosensors applications. In this study, we demonstrate the use of PANI nanowires (NWs) as immobilization platforms in the configuration of an electrochemical immunosensor for label free detection of Japanese encephalitis virus. The PANI NWs were synthesized on the surface of an interdigitated platinum (Pt) microelectrode via electrochemical growth. The morphology and characteristics of the PANI NWs on the Pt microelectrode were verified by scanning electron microscopy and Fourier transform infrared spectroscopy. The anti- Japanese encephalitis virus polyclonal IgG antibody was then covalently immobilized on the PANI NWs-coated Pt microelectrode by using 1-ethyl-3-(3-dimethyaminopropyl) carbodiimide (EDC) and N-hydroxysuccinimde (NHS). The detection of Japanese encephalitis virus antigens was analyzed by electrochemical impedance spectroscopy (EIS). The developed PANI NWs-based electrochemical immunosensor could detect the Japanese encephalitis virus with a detection limit below 10 ng/ml. The results from EIS analysis also indicate that when the PANI NWs were exposed to nonspecific molecules, a negligible response was found, and it did not impact to the specificity of the sensor in the virus detection. This work shows the potential use of PANI NWs in electrochemical immunosensors for label free detection of other pathogens and small biomolecules.  相似文献   

2.
Aflatoxins are a group of mycotoxins that have deleterious effects on humans and are produced during fungal infection of plants or plant products. An electrochemical immunosensor for the determination of aflatoxin B1 (AFB1) was developed with AFB1antibody (AFB1-Ab) immobilized on Pt electrodes modified with polyaniline (PANi) and polystyrene sulphonic acid (PSSA). Impedimetric analysis shows that the electron transfer resistances of the Pt/PANi–PSSA electrode, the Pt/PANi–PSSA/AFB1-Ab immunosensor and Pt/PANi–PSSA/AFB1-Ab incubated in bovine serum albumin (BSA) were 0.458, 720 and 1,066 kΩ, respectively. These results indicate that electrochemical impedance spectroscopy (EIS) is a suitable method for monitoring the change in electron transfer resistance associated with the immobilization of the antibody. Modelling of EIS data gave equivalent circuits which showed that the electron transfer resistance increased from 0.458 kΩ for the Pt/PANi–PSSA electrode to 1,066 kΩ for the Pt/PANi–PSSA/AFB1-Ab immunosensor, indicating that immobilization of the antibody and incubation in BSA introduced an electron transfer barrier. The AFB1 immunosensor had a detection limit of 0.1 mg/L and a sensitivity of 869.6 kΩ L/mg.  相似文献   

3.
通过电聚合制得新型聚钙羧酸修饰电极并用于构建检测甲胎蛋白(AFP)的高灵敏电化学免疫传感器. 采用扫描电镜(SEM)、电化学交流阻抗(EIS)观察、表征修饰电极和AFP单克隆抗体(Ab1)固定前后的差异. 固定Ab1的电极与一定浓度的AFP、辣根过氧化物酶联AFP单克隆抗体(HRP-Ab2)反应,形成夹心型免疫复合物. 辣根过氧化物酶(HRP)催化3,3',5,5'-四甲基联苯胺(TMB)底物产生电流信号,实现AFP浓度的测定. 本检测方法灵敏度高,重现性好.  相似文献   

4.
Gao X  Zhang Y  Wu Q  Chen H  Chen Z  Lin X 《Talanta》2011,85(4):1980-1985
A simple and controllable one-step electrodeposition method for the preparation of a chitosan-carbon nanotubes-gold nanoparticles (CS-CNTs-GNPs) nanocomposite film was used to fabricate an immunosensor for detection of carcinoembryonic antigen (CEA). The porous three-dimensional CS-CNTs-GNPs nanocomposite film, which offered a large specific surface area for immobilization of antibodies, exhibited improved conductivity, high stability and good biocompatibility. The morphology of the formed nanocomposite film was investigated by scanning electron microscopy (SEM), and the electrochemical behaviors of the immunosensor were characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). Under the optimal conditions, the proposed immunosensor could detect CEA in two linear ranges from 0.1 to 2.0 ng mL−1 and from 2.0 to 200.0 ng mL−1, with a detection limit of 0.04 ng mL−1. The immunosensor based on CS-CNTs-GNPs nanocomposite film as the antibody immobilization matrix could exhibit good sensitivity, stability, and reproducibility for the determination of CEA.  相似文献   

5.
The concentration of anti-transglutaminase antibodies in human sera is an important analytical marker for the diagnosis of the autoimmune disorder celiac disease. In this work, an immunosensor for the electrochemical detection of anti-transglutaminase antibodies in human sera was developed. The immunosensor is based on the immobilization of transglutaminase onto screen-printed gold electrodes which were covered with a polyelectrolyte layer of poly (sodium-4-styrensulfonic acid). The antigen-antibody interaction was evaluated using an amplification step: incubation with peroxidase (POD)-labeled immunoglobulins and subsequent biocatalytic oxidation of 3-amino-9-ethylcarbazole (AEC). Changes in the interfacial properties of the sensor electrode were determined by electrochemical impedance spectroscopy (EIS). Impedance spectra could be fitted to a Randles equivalent circuit containing a constant phase element (CPE). Furthermore, it was shown that impedance measurements could be simplified by performing EIS at only two selected frequencies, without loss of reliability. Incubation of these disposable immunosensor chips with various anti-transglutaminase antibody concentrations resulted in changes in their charge transfer resistance (Rct). Thereby, a calibration graph could be established. Finally, immunosensors were used for characterizing different human sera with respect to their anti-transglutaminase autoantibody concentration of the IgG and IgA type.  相似文献   

6.
Balkenhohl T  Lisdat F 《The Analyst》2007,132(4):314-322
An immunosensor has been developed for the detection of autoantibodies directed against wheat gliadin, a protein fraction of cereal gluten which is involved in celiac disease. The immunosensor is based on the immobilization of gliadins onto gold electrodes covered with a polyelectrolyte layer of poly(4-styrenesulfonic acid sodium salt). The immobilization was monitored by quartz crystal microbalance (QCM) analysis. The antigen-antibody interaction signal was amplified by an incubation step with peroxidase-labeled immunoglobulins and subsequent peroxidase-catalyzed oxidation of 3-amino-9-ethylcarbazole (AEC). Changes in the insulating properties of the electrode layer were measured by electrochemical impedance spectroscopy (EIS) in the presence of ferri/ferro-cyanide. Impedance spectra could be fitted to a Randles equivalent circuit with high accuracy. Exposing the sensor electrodes to various antigliadin antibody concentrations resulted in proportional changes in the charge transfer resistance. A calibration graph for the detection of antigliadin antibodies was established for antibody concentrations between 10(-8) and 10(-6) M. Finally, the sensor was used for the determination of antigliadin autoantibodies of the IgG and IgA type in several human sera.  相似文献   

7.
In the present study, we developed a novel label‐free capacitance impedimetric immunosensor based on the immobilization of the human monoclonal antibody anti‐interleukin‐10 (anti‐IL‐10 mAb) onto polypyrrole (PPy)‐modified silicon nitride (Si3N4) substrates. The immunosensor was used for the detection of the recombinant interleukin‐10 antigen (rh IL‐10) that may be secreted in patients at the early stage of inflammation. The immunosensor was created by chemical deposition of PPy conducting layer on pyrrole?silane (SPy)‐treated Si/SiO2/Si3N4 substrates (Si/SiO2/Si3N4?SPy), followed by anti‐IL‐10 mAb immobilization through carboxyl‐functionalized diazonium (CMA) protocol and carbodiimide chemistry. The surface characterization and the biofunctionalization steps were characterized by SEM, FTIR and cyclic voltammetry (CV) while the detection process was carried out by using electrochemical impedance spectroscopy (EIS) analyses. The created immunosensor showed two linear fittings (R2=0.999) for the detection of rh IL‐10 within the concentration range from 1–50 pg/mL. It exhibited high sensitivity (0.1128 (pg/mL)?1) with a very low limit of detection (LOD)=0.347 pg/mL, more particularly, at the low concentration range (1–10 pg/mL). Thus, this developed polypyrrole‐based immunosensor represents a promising strategy for creation of miniaturized label‐free, fast and highly sensitive biosensors for diagnosis of inflammation biomarkers at very low concentrations with reduced cost.  相似文献   

8.
A new electrochemical immunosensor for the detection of α‐1‐fetoprotien (AFP) was developed based on AFP antibody (anti‐AFP)‐functionalized organic/inorganic hybrid nanocomposite membrane. To fabricate such a hybrid composite membrane, 3,4,9,10‐perylenetetracarboxylic acid‐bound thionine molecules (PTCTH) were initially doped into titania colloids (TiO2), and then gold nanoparticles and anti‐AFP were immobilized onto the composite film in turn. Comparison with the electrode fabricated only with thionine not 3,4,9,10‐perylenetetracarboxylic acid, the immunosensor with PTCTH exhibited high sensitivity and fast electron transfer. The presence of gold nanoparticles provided a good microenvironment for the immobilization of biomolecules, enhanced the surface coverage of protein, and improved the sensitivity of the immunosensor. The modified process was characterized by scanning electron microscope (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The surface topography of the membrane was investigated by scanning electron microscopy (SEM). Under optimal conditions, the proposed immunosensor exhibited a wide linear range from 2.5 to 200.0 ng/mL towards AFP with a detection limit of 0.5 ng/mL (S/N=3). The stability, reproducibility and precision of the immunosensor were acceptable. Comparison with the conventional enzyme‐linked immunosorbent assay (ELISA), the present method did not require more labeled procedures and washing steps. Significantly, the detection methodology provides a promising approach for other proteins or biosecurities.  相似文献   

9.
《Electroanalysis》2005,17(2):155-161
A highly sensitive immunosensor based on immobilization of hepatitis B surface antibody (HBsAb) on platinum electrode (Pt) modified silver colloids and polyvinyl butyral (PVB) as matrixes has been developed for potentiometric immunoanalysis to detect hepatitis B surface antigen (HBsAg) in this study. HBsAb molecules were immobilized successfully on nanometer‐sized silver colloid particles associated with polyvinyl butyral on a platinum electrode surface. The modification procedure was electrochemically monitored by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The HBsAb‐silver‐PVB‐modified electrode exhibited direct electrochemical behavior toward HBsAg. The factors influencing the performance of the resulting immunosensor were studied in detail. More than 94.7% of the results of human serum samples obtained by this method were in agreement with those obtained by enzyme‐linked immunosorbent assays (ELISAs). The resulting immunosensor exhibited a sigmoid curve with log HBsAg concentration, high sensitivity (39.8 mV/decade), wide linear range from 16.0 to 800 ng mL?1 with a detection limit of 3.6 ng mL?1, fast potentiometric response (<3 min) and long‐term stability (>4 months). The response mechanism of the immunosensors was also studied with AC impedance techniques.  相似文献   

10.
Lee YG  Chang KS 《Talanta》2005,65(5):1335-1342
Bovine ephemeral fever (BEF) is a viral disease of cattle. A flow type quartz crystal microbalance (QCM) immunosensor was developed for the real time determination BEF virus (BEFV) that is suitable for clinical point-case diagnosis. Self-assembled monolayer (SAM) of thiols and sulphides by the cystamine–glutaraldehyde method was used for the immobilization of BEFV monoclonal antibody on the gold surface of a quartz crystal microbalance (QCM). A positive correlation was found between the virus concentration and frequency changes (R2 = 0.9962) on this QCM system. The reproducible rates for the 50 and 10 μg/mL samples were 4 and 13.9%, respectively. There was no interference from non-specifically adsorbed phage. Using this flow type QCM immunosensor, BEFV could specifically be detected with sensitivity comparable to a conventional enzyme-linked immunosorbent assay (ELISA). The measurement could be obtained directly, within several minutes, rather than hours as required visualizing the results of ELISA. In addition, the observation of reproducible and constant changes after successive additions of BEFV suggests that a QCM immunosensor in a flow cell could be developed for automated or continuous real time operation.  相似文献   

11.
《Electroanalysis》2017,29(8):1867-1875
A capacitive immunosensor for determination of sulphathaizole (STZ) has been developed on polymer coated indium tin oxide glass chip (ITO). The immunosensor chip was fabricated by polymerizing, ortho‐ phenylenediamine (o PD) on ITO followed by surface modification with anti‐sulphathiazole antibody. The developed immunosensor chip was characterized by using Atomic force microscopy (AFM), Cyclicvoltammetry (CV) and Electrochemical impedance spectroscopy (EIS). The capacitive measurement of the developed immunosensor was performed by using EIS in spiked drinking water and milk. The developed sensor showed liner detection range 0.1‐100 μgL−1for STZ with a limit of detection 0.01 μgL−1 in water with recovery between 95–106 %. The biosensor showed excellent selectivity and storage stability upto 4 weeks when preserved at 4 °C.  相似文献   

12.
基于金属离子螯合的压电免疫传感器新型固定化方法   总被引:1,自引:0,他引:1  
陈媛  吴朝阳  沈国励  俞汝勤 《化学学报》2008,66(12):1455-1459
提出了一种基于金属离子螯合作用的压电免疫传感器新型固定化方法. 先在压电石英晶振表面沉积正丁胺等离子体聚合膜(BA-PPF), 再在BA-PPF表面修饰可与金属离子螯合的氨三乙酸基团, 用金属铜离子活化后, 修饰了二乙三胺五乙酸基团的IgG抗体蛋白质分子即可螯合固定于BA-PPF上. 将固定了抗体的压电石英传感器用于正常人免疫球蛋白IgG (NHIgG)的测定, 其频率响应与NHIgG浓度在0.36~63.8 μg/mL范围内存在良好的线性关系. 这种新型压电免疫传感器固定化方法简单快速, 具有良好的通用性.  相似文献   

13.
在玻碳电极(GCE)表面固定对H2O2有催化还原活性的富马酸二甲酯联吡啶铜(GCE|CuL);再在GCE|CuL表面修饰一层金磁微粒-壳聚糖复合膜(nano Au/Fe3O4/Chit), 进而固定艾滋病毒(HIV)诊断标志物--包膜糖蛋白(gp160)抗体(anti gp160), 由此构建了一类快速检测 gp160的无试剂安培免疫传感器.当该传感器在含gp160溶液中37 ℃下温育30 min后, 传感器表面生成的免疫复合物随gp160浓度的增大而增加, 导致CuL 对H2O2 电催化还原效果降低, 催化电流呈现下降趋势.在PBS溶液(pH 7.0)和-300 mV下, 催化电流的降低值ΔIo与gp160浓度在1~400 μg/L 呈线性关系; 检出限为0.5 μg/L(3σ).研制的免疫传感器检测gp160时, 一步免疫反应即可得结果, 较相同条件下包被gp160抗体的纳米金单分子层修饰电极灵敏度更高, 检测范围更宽, 有望用于艾滋病人血清标志物gp160快速筛测.  相似文献   

14.
Yi Wan  Dun Zhang  Baorong Hou 《Talanta》2009,80(1):218-401
An impedimetric immunosensor was fabricated for rapid and non-labeled detection of sulfate-reducing bacteria, Desulforibrio caledoiensis (SRB) by immobilizing lectin-Concanavalin A using an agglutination assay. The immobilization of lectin was conducted using amine coupling on the surface of a gold (Au) electrode assembled with 11-Mercaptoundecanoic acid. Electrochemical impedance spectroscopy (EIS) was used to verify the stepwise assembly of the sensor system. The work conditions of the impedimetric immunosensor, such as pH of the buffer solutions and the incubation time of lectin, were optimized. Faradic impedance spectra for charge transfer for the redox probe Fe(CN)63−/4−were measured to determine SRB concentrations. The diameter of the Nyquist diagram that is equal to the charge-transfer resistance (Rct) increased with increasing SRB concentration. A linear relationship between Rct and SRB concentration was obtained in SRB concentration range of 1.8 to 1.8 × 107 cfu/ml. The variation of the SRB population during the growth process was also monitored using the impedimetric immunosensor. This approach has great potential for simple, low-cost, and time-saving monitoring of microbial populations.  相似文献   

15.
在金电极表面电沉积银为氧化还原探针,利用有机多孔材料(PTC-NH2)、纳米金(nano-Au)固载甲胎蛋白抗体(anti-AFP),制备出用于检测甲胎蛋白(AFP)的安培型免疫传感器。通过交流阻抗技术、循环伏安法研究了电极的电化学特性,考察了孵育时间、测试液pH值等实验条件对传感器性能的影响,并利用扫描电子显微镜(SEM)对电极的修饰过程进行了表征。该传感器对AFP有良好的电流响应,线性范围分别为1.0~20.0ng/mL和20.0~60.0 ng/mL,检测限为0.6 ng/mL。  相似文献   

16.
A new immunosensor is presented for human chorionic gonadotropin (hCG), made by electrodepositing chitosan/gold‐nanoparticles over graphene screen‐printed electrode (SPE). The antibody was covalently bound to CS via its Fc‐terminal. The assembly was controlled by electrochemical Impedance Spectroscopy (EIS) and followed by Fourier Transformed Infrared (FTIR). The hCG‐immunosensor displayed linear response against the logarithm‐hCG concentration for 0.1–25 ng/mL with limit of detection of 0.016 ng/mL. High selectivity was observed in blank urine and successful detection of hCG was also achieved in spiked samples of real urine from pregnant woman. The immunosensor showed good detection capability, simplicity of fabrication, low‐cost, high sensitivity and selectivity.  相似文献   

17.
Screening of Prostate-specific antigen (PSA) in human blood is the most common approach to diagnose prostate cancer. The joint application of biology and electrochemistry has shown a tremendous rise in research towards the development of electrochemical diagnostic tools for various diseases. The present study demonstrates the development of an effective immunosensing platform incorporating hydroquinone (HQ) immobilized, fullerene-C60 and copper nanoparticles (CuNPs) composite film on glassy carbon electrode (HQ@CuNPs-reduced-fullerene-C60/GCE) for the selective, quick and trace detection of PSA. In order to fabricate immunosensor sequential immobilization of primary antibody (Ab1), blocking agent (bovine serum albumin (BSA)), antigen (prostate-specific antigen (PSA)) and secondary antibody (Ab2) tagged with horseradish peroxide (HRP) was carried out on HQ@CuNPs-reduced-fullerene-C60/GCE. Electrochemical characterization and the signal response of immunosensor were tested using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Due to the synergetic effect of fullerene-C60 and CuNPs, the novel nanocomposite film exhibited excellent catalytic activity towards hydrogen peroxide (H2O2) reduction for greatly amplified immunosensing signals. HQ@CuNPs-fullerene-C60/GCE exhibited a well-defined redox peak and accelerated electrochemical reduction of H2O2 without any interference of dissolved oxygen and false-positive result in phosphate buffer solution (PBS) at pH 7.0. The parameters influencing the electrochemical response were optimized. Under the optimized conditions, wide linearity between PSA concentrations and current responses ranging from 0.005 ng/mL to 20 ng/mL with the lower detection limit of 0.002 ng/mL was obtained at the proposed immunosensor. The clinical applicability of the proposed immunosensor was successfully tested in serum and urine samples. Results revealed that the proposed immunosensor may create new boundaries in the identification of PSA in human blood samples.  相似文献   

18.
A novel magnetic electrochemical immunosensor has been developed for the detection of pseudorabies virus antibody in swine serum. The magnetic glass carbon electrode was fabricated to manipulate magnetic beads for the direct sensing applications. Magnetic beads were employed as the platforms for the immobilization and immunoreaction process, and gold nanoparticles were chosen as electroactive labels for the electrochemical detection. The parameters concerning the assay strategy were carefully investigated. Under the optimal conditions, the linear response range of pseudorabies virus antibody dilution ratio (standard positive serum) was 1:250 to 1:1000 with a detection limit of 1:1000. Finally, this developed immunoassay method was successfully applied in the detection of pseudorabies virus antibody in swine serum, and had a good diagnostic accordance in comparison with ELISA.  相似文献   

19.
An electrochemical label-free immunosensor based on a biotinylated single-chain variable fragment (Sc-Fv) antibody immobilized on copolypyrrole film is described. An efficient immunosensor device formed by immobilization of a biotinylated single-chain antibody on an electropolymerized copolymer film of polypyrrole using biotin/streptavidin system has been demonstrated for the first time. The response of the biosensor toward antigen detection was monitored by surface plasmon resonance (SPR) and electrochemical analysis of the polypyrrole response by differential pulse voltammetry (DPV). The composition of the copolymer formed from a mixture of pyrrole (py) as spacer and a pyrrole bearing a N-hydroxyphthalimidyl ester group on its 3-position (pyNHP), acting as agent linker for biomolecule immobilization, was optimized for an efficient immunosensor device. The ratio of py:pyNHP for copolymer formation was studied with respect to the antibody immobilization and antigen detection. SPR was employed to monitor in real time the electropolymerization process as well as the step-by-step construction of the biosensor. FT-IR demonstrates the chemical copolymer composition and the efficiency of the covalent attachment of biomolecules. The film morphology was analyzed by electron scanning microscopy (SEM).Results show that a well organized layer is obtained after Sc-Fv antibody immobilization thanks to the copolymer composition defined with optimized pyrrole and functionalized pyrrole leading to high and intense redox signal of the polypyrrole layer obtained by the DPV method. Detection of specific antigen was demonstrated by both SPR and DPV, and a low concentration of 1 pg mL−1 was detected by measuring the variation of the redox signal of polypyrrole.  相似文献   

20.
Qi H  Ling C  Ma Q  Gao Q  Zhang C 《The Analyst》2012,137(2):393-399
A novel electrochemical immunosensor array for the simultaneous detection of multiple tumor markers was developed by incorporating electrochemically addressing immobilization and one signal antibody strategy. As a proof-of-principle, an eight-electrode array including six carbon screen-printed working electrodes was used as a base array for the analysis of two important tumor markers, carcinoembryonic antigen (CEA) and α-fetoprotein (AFP) and a horseradish peroxidase-labeled antibody was employed as a signal antibody. The immunosensor in the array was fabricated in sequence by covalently coupling the capture antibody onto the surface of the desired working electrode, which was firstly electrochemically addressably grafted with an aminophenyl group by reduction of in situ generated aminophenyl diazonium cation generated from p-phenylenediamine, using glutaraldehyde as cross-linker. This allowed the selective immobilization of the capture antibody at the desired position on a single array via an electrochemical operation. The immunoassay in sandwich mode was performed by specifically binding the targets, second antibodies and one signal antibody to the immunosensor array. The result showed that the steady current density was directly proportional to the concentration of target CEA/AFP in the range from 0.10 to 50 ng mL(-1) with a detection limit of 0.03 ng mL(-1) for CEA and 0.05 ng mL(-1) for AFP (S/N = 3), respectively. This work demonstrates that the employment of an electrochemically addressing method for the fabrication of an immunosensor array and one signal antibody is a promising approach for the determination of multiple tumor markers in clinical samples.  相似文献   