首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sensitive electrochemical method for square‐wave voltammetric detection of organophosphate (OP) compounds was developed based on zirconia (ZrO2) nanoparticles modified electrode. The electrode was fabricated using electrochemical deposition and characterized by scanning electron microscopy (SEM), which confirmed the successful formation of nanoparticles. Due to the strong affinity of ZrO2 with the phosphoric group, nitroaromatic OPs can strongly bind to the surface of ZrO2 nanoparticles (ZrO2NPs). Under optimized operational conditions, SWV was employed for Omethoate (a model of OP compounds) detection with 5 min absorption, which showed a wide detection range from 98.5 pmol·L?1 to 985 nmol·L?1, with a detection limit as low as 52.5 pmol·L?1. This electrochemical sensor has good selectivity, stability and reproducibility, and great potential in the detection of OP compounds in agriculture area.  相似文献   

2.
A novel, sensitive and rapid voltammetric method applied for daclatasvir dihydrochloride (DSV.2HCl) detection in raw material, human plasma and urine using square wave voltammetry at a nano‐screen printed electrode (SPE) based on synthesized zirconium oxide nanoparticles (ZrO2 NPs). The attention to zirconium oxide nanoparticle syntheses arises from its likely use in making an electrode material in the electroanalytical process. Anodic stripping square wave voltammetric peaks have been recorded at the optimum conditions of drug solution as pH, scan rate, accumulation time and accumulation potential. Morphology of the used nanoparticles has been performed by scanning electron microscope (SEM) and transmission microscope (TEM). ZrO2 NPs were applied to screen printed electrode (ZrO2‐MSPE) giving a new sensor to detect the DSV.2HCl drug. ZrO2 NPs were tested for their electroactivity in improving electrodes sensitivity. The modified electrode has been used for the analysis of DSV.2HCl in spiked serum, spiked urine and pharmaceutical formulation.  相似文献   

3.
Ag@iron oxide nanocomposite powders were synthesized via a two‐step chemical method. Characterization by UV‐Vis, XRD, SEM‐EDX and TEM revealed they are composed of nanosized crystalline silver particles in strict contact with amorphous iron oxide(s). The electrochemical behavior of the synthesized Ag@iron oxide composite was investigated by cyclic voltammetry. Compared with the single phase‐modified electrodes, the Ag@iron oxide/SPCE electrode exhibits an enhanced cathodic current in response to the target analyte, due to a synergistic effect between Ag crystallites and amorphous iron oxide nanoparticles. An amperometric sensor for detection of nitrate based on Ag@iron oxide modified screen‐printed electrode (Ag@iron oxide/SPCE) has been fabricated, showing a good sensitivity (663 µA mM?1 cm?2) and a detection limit of 30 µM.  相似文献   

4.
《中国化学会会志》2018,65(9):1082-1089
In this work, a screen‐printed carbon electrode (SPCE) was modified with a cobalt/porous silicon (Co@PSi) nanocomposite powder to develop a nonenzymatic sensor for the detection of hydrogen peroxide. The Co@PSi nanocomposite was synthesized through the chemical reaction between silicon powder in a HF/HNO3 solution and cobalt cations. In this process, cobalt nanoparticles were anchored on the porous silicon. The structure and morphology of the synthesized nanocomposite were investigated by X‐ray diffraction, Fourier transform infrared spectroscopy, X‐ray photoemission spectroscopy, energy dispersive X‐ray spectroscopy, and field‐emission scanning electron microscopy. The constructed nonenzymatic, screen‐printed sensors based on the Co@PSi nanocomposite showed perfect electrocatalytic oxidation response to hydrogen peroxide over the range 1–170 and 170–3,770 μmol/L with the limit of detection of 0.8 μmol/L. In addition, the Co@PSi‐SPCE sensor exhibited good selectivity for the determination of H2O2 in the presence of common interfering species including glucose, ascorbic acid, uric acid, dopamine, nitrate, and nitrite ions. The constructed electrochemical sensor was successfully used for the determination of H2O2 in real samples.  相似文献   

5.
《Electroanalysis》2018,30(5):969-974
A new chemically modified electrode based on titanium dioxide nanoparticles (TiO2‐NPs) has been developed. Aluminium was incorporated into the TiO2‐NPs to prepare aluminium doped TiO2 nanoparticles (Al‐TiO2‐NPs). Aluminium doped TiO2 nanoparticles‐modified screen printed carbon electrode (Al‐TiO2‐NPs/SPCE) was employed as easy, efficient and rapid sensor for electrochemical detection of vanillin in various types of food samples. Al‐TiO2‐NPs were characterized by energy‐dispersive X‐ray (EDX), transmission electron microscopy (TEM), and X‐ray diffraction (XRD) and analyses showing that the average particle sizes varied for the Al‐NPs (7.63 nm) and Al‐TiO2‐NPs (7.47 nm) with spherical crystal. Cyclic voltammetry (CV) and linear sweep voltammetry (LSV) were used to optimize the analytical procedure. A detection limit of vanillin was 0.02 μM, and the relative standard deviation (RSD) was 3.50 %, obtained for a 5.0 μM concentration of vanillin. The electrochemical behaviour of several compounds, such as vanillic acid, vanillic alcohol, p‐hydroxybenzaldehyde and p‐hydroxybenzoic, etc., generally present in natural vanilla samples, were also studied to check the interferences with respect to vanillin voltammetric signal. The applicability was demonstrated by analysing food samples. The obtained results were compared with those provided by a previous method based on liquid chromatography for determination of vanillin.  相似文献   

6.
The Pd, AuPd, and ZrO2 nanoparticle–decorated functionalised multiwalled carbon nanotubes (f‐MWCNTs) were reported as efficient catalysts of formic acid (FA) electro‐oxidation. Different preparation conditions influence their chemical and structural properties analysed by X‐ray photoelectron spectroscopy aided with the quantitative analysis of surfaces by electron spectroscopy. Different reduction procedures such as NaBH4, a polyol microwave‐assisted method (PMWA), and a high pressure microwave reactor (HPMWR) were applied for decorating ZrO2/f‐MWCNTs with Pd and AuPd nanoparticles. The ZrO2 nanoparticles are attached through oxygen groups to the surface of f‐MWCNTs. In NaBH4 and HPMWR procedures, Pd nanoparticles precipitate predominantly on ZrO2 of nearly nominal stoichiometry, whereas in PMWA procedure, Pd and AuPd nanoparticles precipitate predominantly on the surface of f‐MWCNTs, bridging with oxygen groups and ZrOx (x < 2) and leading to Pd‐O‐Zr phase formation. Strong reducing procedures (NaBH4 and FA) led to smaller Pd nanoparticle size, Pd oxide content, and PdOx overlayer thickness in contrary to weak reduction procedures (HPMWR and PMWA). The highest content of Pd‐O‐Zr phase appeared for Pd predominant precipitation on ZrO2 nanoparticles (HPMWR) in contrary to Pd and AuPd predominant precipitation on surface of f‐MWCNTs (NaBH4 ~ FA > PMWA). Larger content of Pd‐O‐Zr phase in AuPd‐decorated ZrO2/f‐MWCNTs in contrary to Pd‐decorated sample (PMWA) could be justified by different electronic properties of nanoparticles. The FA treatment of Pd and AuPd‐ZrO2/f‐MWCNTs samples provided decreasing Pd oxide content, overlayer thickness, nanoparticle size, increasing nanoparticle surface coverage and density, amount of Pd‐O‐Zr, what results from reduction of oxygen groups bridging with Pd and ZrOx nanoparticles, also through Pd‐O‐Zr phase.  相似文献   

7.
Herein, we have demonstrated a preparation of palladium nanoparticles on electroactivated graphite nanosheets modified screen printed carbon electrode (PdNPs‐EGNS/SPCE) by a simple electrochemical method. The well‐prepared electrocatalyst was potentially applied to the high performance electrocatalytic oxidation of hydrazine in neutral medium. The PdNPs‐EGNS novel composite was characterized by scanning electron microscope (SEM) and the average diameter and thickness of PdNPs and EGNS were found to be ~38 nm and 85 nm, respectively. The high performance electrocatalytic determination of hydrazine was performed by the amperometric i‐t method. The fabricated sensor displayed irreversible electrocatalytic oxidation of hydrazine with diffusion‐controlled electrode process. The oxidation of hydrazine at PdNPs‐EGNS/SPCE showed wider linear range 0.05–1415 µM and high sensitivity 4.382 µA µM?1 cm?2. The as‐prepared electrocatalyst achieved quick response towards hydrazine with a lower detection limit 4 nM.  相似文献   

8.
《Electroanalysis》2018,30(9):2121-2130
Highly crystallized mesoporous ZrO2 nanomaterials were synthesized by solvent evaporation induced self‐assembly approach. Ordered mesoporous ZrO2 nanomaterials were characterized by TEM, SEM, BET, XRD and UV‐Vis spectroscopy. The obtained nanomaterials exhibit the close‐packing mesopores with average pore size of 7 nm and a highly crystallized framework with tetragonal phase. A non‐enzyme electrochemical sensor based on ordered mesoporous ZrO2 is established for selective detection of methyl parathion (MP). The online extraction of MP is firstly achieved by ZrO2 modified electrode at open‐circuit potential for 5 min., and the sensitive detection of MP is performed by differential pulse voltammetry (DPV) method. By comparison, DPV responses of mesoporous ZrO2 are 40 times and 25 times larger than that of mesoporous silica and mesoporous carbon with the similar pore structure, implying the specific affinity advantage of zirconia to phosphoric group. The quantitative analysis result shows that the voltammetric currents are linear with concentrations of MP ranging from 1 ng/ml to 2 μg/ml with a detection limit of 0.53 ng/ml. The sensor also exhibits good stability and high selectivity against interfering species. The excellent analytical performances are owed to the accessible and uniform mesoporous structures, highly crystallized frameworks of ZrO2 and its specific affinity to phosphate groups.  相似文献   

9.
Anajafi  Z.  Naseri  M.  Marini  S.  Espro  C.  Iannazzo  D.  Leonardi  S. G.  Neri  G. 《Analytical and bioanalytical chemistry》2019,411(29):7681-7688

A new electrochemical sensor, based on NdFeO3 nanoparticles as electrocatalytic material, was proposed here for the detection of dopamine (DA). NdFeO3 nanoparticles were first synthesized by a simple thermal treatment method and subsequent annealing at high temperature (700 °C). The prepared electrocatalytic material has been characterized in detail by SEM-EDX, XRD, and Raman techniques. Characterization results display its sheet-like morphology, constituted by a porous network of very small orthorhombic NdFeO3 nanoparticles. NdFeO3 electrocatalytic material was then used to modify the working electrode of screen-printed carbon electrodes (SPCEs). Electrochemical tests demonstrated that NdFeO3– modified screen-printed carbon electrode (NdFeO3/SPCE) exhibited a remarkable enhancement of the dopamine electrooxidation, compared to the bare SPCE one. The analytical performance of the developed sensor has been evaluated for the detection of this analyte by means of the square-wave voltammetry (SWV) technique. The modified electrode showed two linear concentration ranges, from 0.5 to 100 μM and 150 to 400 μM, respectively, a limit of detection (LOD) of 0.27 μM (at S/N = 3), and good reproducibility, stability, and selectivity. Additionally, we also report an attempt made to propose the modified sensor for the simultaneous detection of dopamine and uric acid (UA). The procedure was also applied for the determination of dopamine in spiked real samples. So, this paper reports for the first time the use of a modified NdFeO3 screen-printed electrode for developing an electrochemical sensor for the quantification of important biomolecules.

Graphical abstract

  相似文献   

10.
A novel, simple and versatile protocol for covalent immobilization of horseradish peroxidase (HRP) on screen‐printed carbon electrode (SPCE) based on the combination of diazonium salt electrografting and click chemistry has been successfully developed. The ethynyl‐terminated monolayers are obtained by diazonium salt electrografting, then, in the presence of copper (I) catalyst, the ethynyl modified surfaces reacted efficiently and rapidly with horseradish peroxidase bearing an azide function (azido‐HRP), thus forming a covalent 1,2,3‐triazole linkage by means of click chemistry. All the experimental results suggested that HRP was immobilized onto the electrode surface successfully without denaturation. Furthermore, the immobilized HRP showed a fast electrocatalytic reduction for H2O2. A linear range from 5.0 to 50.0 µM in a phosphate buffer (pH 5.5) with detection limit of 0.50 µM and sensitivity of 0.23 nA/µM were obtained. The heterogeneous electron transfer rate constant Kct was 1.52±0.22 s?1 and the apparent Michaelis? Menten constant was calculated to be 0.028 mM. The HRP‐functionalized electrode demonstrated a good reproducibility and long‐term stability.  相似文献   

11.
A novel biosensor was developed by entrapping cytochrome c (Cyt c) in thin films of the room temperature ionic liquid (RTIL) containing nanocomposites of poly(diallyldimethylammonium chloride)‐graphene nanosheets‐gold nanoparticles (PDDA‐Gp‐AuNPs) at a 11‐mercaptoundecanoic acid‐6‐mercapto‐1‐hexanol modified gold electrode. The synthesized PDDA‐Gp‐AuNPs hybrid nanocomposites were characterized by UV‐vis spectroscopy, Raman spectroscopy, scanning electron microscopy and atomic force microscopy. The PDDA‐Gp‐AuNPs nanocomposites could increase the effective surface of the electrode, enhance the fixed amount of Cyt c on the electrode surface, promote the electron transfer and facilitate the catalytic activity of Cyt c. The RTIL could provide a biocompatible microenvironment to keep Cyt c biological activities, act as an effective mediator to immobilize a large number of Cyt c on the electrode and have good conductivity to improve electron transfer. Therefore, the resultant electrode exhibited good electrochemical performance and electrocatalytic activity. It could be used for electrochemical detection of H2O2 with rapid response, high sensitivity, wide linear range and low detection limit, as well as good stability, repeatability and selectivity. The sensor might be promising for practical application.  相似文献   

12.
In this work, we report on the preparation of a simple, sensitive DNA impedance sensor. Firstly gold nanoparticles were electrodeposited on the surface of a gold electrode, and then probe DNA was immobilized on the surface of gold nanoparticles through a 5′‐thiol‐linker. Electrochemical impedance spectroscopy (EIS) was used to investigate probe DNA immobilization and hybridization. Compared to the bare gold electrode, the gold nanoparticles modified electrode could improve the density of probe DNA attachment and the sensitivity of DNA sensor greatly. The difference of electron transfer resistance (ΔRet) was linear with the logarithm of complementary oligonucleotides sequence concentrations in the range of 2.0×10?12 to 9.0×10?8 M, and the detection limit was 6.7×10?13 M. In addition, the DNA sensor showed a fairly good reproducibility and stability during repeated regeneration and hybridization cycles.  相似文献   

13.
An amperometric tyramine biosensor based on poly‐L‐lysine (PLL) and Fe3O4 nanoparticles (Fe3O4NP) modified screen printed carbon electrode (SPCE) was developed. PLL was formed on the SPCE by the electropolymerization of L‐lysine. Subsequently, Fe3O4NP suspension prepared in chitosan (CH) solution was casted onto the PLL/SPCE. Tyrosinase (Ty) enzyme was immobilized onto the modified Fe3O4?CH/PLL/SPCE and the electrode was coated with Nafion to fabricate the Ty/Fe3O4?CH/PLL/SPCE. Different techniques including scanning electron microscopy, chronoamperometry (i–t curve), cyclic voltammetry and electrochemical impedance spectroscopy were utilized to study the fabrication processes, electrochemical characteristics and performance parameters of the biosensor. The analytical performance of the tyramine biosensor was evaluated with respect to linear range, sensitivity, limit of detection, repeatability and reproducibility. The response of the biosensor to tyramine was linear between 4.9×10?7–6.3×10?5 M with a detection limit of 7.5×10?8 M and sensitivity of 71.36 μA mM?1 (595 μA mM?1 cm?2). The application of the developed biosensor for the determination of tyramine was successfully tested in cheese sample and mean analytical recovery of added tyramine in cheese extract was calculated as 101.2±2.1 %. The presented tyramine biosensor is a promising approach for tyramine analysis in real samples due to its high sensitivity, rapid response and easy fabrication.  相似文献   

14.
A sensitive electrochemical stripping voltammetric method for analyzing organophosphate (OP) compounds was developed based on solid-phase extraction (SPE) at zirconia (ZrO2) nanoparticles modified electrode. ZrO2 nanoparticles were proved as a new sorbent for SPE of OP pesticides. Because of the strong affinity of ZrO2 for the phosphoric group, nitroaromatic OPs can strongly bind to the ZrO2 nanoparticle surface. The combination of SPE with square-wave voltammetry (SWV) provided a fast, sensitive, and selective electrochemical method for nitroaromatic OP compounds using methyl parathion (MP) as a model. The stripping response was highly linear over the MP range of 0.003–2.0 μg/mL, with a detection limit of 0.001 μg/mL. The fast extraction ability of ZrO2 nanoparticles makes it promising sorbent for various solid-phase extractions.  相似文献   

15.
Two different self‐contained ethanol amperometric biosensors incorporating layered [Ru(phend)2bpy]2+‐intercalated zirconium phosphate (ZrP) as the mediator as well as yeast‐alcohol dehydrogenase (y‐ADH) and its cofactor nicotinamide adenine dinucleotide (NAD+) were constructed to improve upon a design previously reported where only this mediator was immobilized in the surface of a modified electrode. In the first biosensor, a [Ru(phend)2bpy]2+‐intercalated ZrP modified carbon paste electrode (CPE) was improved by immobilizing in its surface both y‐ADH and NAD+ using quaternized Nafion membrane. In the second biosensor, a glassy carbon electrode was modified with [Ru(phend)2bpy]2+‐intercalated ZrP, y‐ADH, and NAD+ using Nafion as the holding matrix. Calibration plots for ethanol sensing were constructed in the presence and absence of ZrP. In the absence of ZrP in the surface of the modified glassy carbon electrode, leaching of ADH was observed as detected by UV‐vis spectrophotometry. Ethanol sensing was also tested in the presence and absence of ascorbate to measure the selectivity of the sensor for ethanol. These two ethanol biosensors were compared to a previously reported one where the y‐ADH and the NAD+ were in solution, not immobilized.  相似文献   

16.
《中国化学会会志》2018,65(8):982-988
CuAg nanoparticles (CuAgNPs) were electrochemically formed in situ on pre‐anodized, screen‐printed carbon electrodes (SPCEs) that possessed many oxygen‐containing functional groups capable of adsorbing metal ions, namely Cu2+ and Ag+. Pre‐anodization was achieved using continuous cyclic voltammetry in the range of potential 0.3–2.0 V under a scan rate of 50 mV/s. Cu2+ and Ag+ ions were adsorbed on the pre‐anodized SPCE by immersing the electrode in solutions containing both metal ions, and then CuAgNPs were formed in situ via electrochemical reduction in a deaerated, neat NaClO4 solution after the electrode was ultrasonicated to remove physically adsorbed metal ions. Although CuNPs showed higher activity than AgNPs toward both nitrate (NO3) and nitrite (NO2) ions, the instability of CuNPs hindered the application, so CuAgNPs were employed to achieve a compromise between sensitivity and stability. The SPCE/anodized/CuAgNP electrodes showed activity toward the electrochemical reduction of NO3 and NO2, respectively, with the limit of detection (LOD) of 15.6 μM (0.97 ppm) and 11.1 μM (0.51 ppm), which is sufficient to fit the allowed values (50 and 3 ppm, respectively) in drinking water as suggested by the World Health Organization (WHO).  相似文献   

17.
Magnetic Fe3O4 nanoparticles functionalized multiwalled carbon nanotubes (nano‐Fe3O4 MWNTs) were prepared for electrochemical sensors. 2‐amino‐5‐mercapto‐1,3,4‐thiadiazole was used as a connecter to form a network that connected nano‐Fe3O4 MWNTs to the Au electrode surface. Modified process of the electrode was studied with SEM, TEM and cyclic voltammetry. Cyclic voltammetry and amperometric i‐t curve were used to investigate characteristics of the obtained electrode. The sensor has been successfully used on the direct detection of catechol and showed excellent performances. The linear regression equation was Ipa(μA)=0.07763+0.16739 C (μmol/L); R=0.9993 and the detection limit was 5.38×10?8 mol/L. The modified electrode showed good reproducibility and stability.  相似文献   

18.
A promising electrochemical nitrite sensor was fabricated by immobilizing Au@Fe3O4 nanoparticles on the surface of L ‐cysteine modified glassy carbon electrode, which was characterized by scanning electron microscopy, X‐ray photoelectron spectroscopy, electrochemical impedance spectroscopy and cyclic voltammetry. The proposed sensor exhibited excellent electrocatalytic activity toward nitrite oxidation. The kinetic parameters of the electrode reaction process were calculated, (1–α)nα was 0.38 and the heterogeneous electron transfer coefficient (k) was 0.13 cm s?1. The detection conditions such as supporting electrolyte and pH value were optimized. Under the optimized conditions, the linear range for the determination of nitrite was 3.6×10?6 to 1.0×10?2 M with a detection limit of 8.2×10?7 M (S/N=3). Moreover, the as‐prepared electrode displayed good stability, repeatability and selectivity for promising practical applications.  相似文献   

19.
Room temperature ionic liquids (RTILs) N‐butylpyridinium hexafluorophosphate (BPPF6) modified carbon paste electrode (CILE) was fabricated and applied to adsorb the hemoglobin (Hb) and TiO2 nanoparticles on the electrode surface step by step to form a Hb modified electrode noted as TiO2/Hb/CILE. UV‐Vis and FT‐IR spectra showed that Hb in the film retained its native conformations. Cyclic voltammetric experiments indicated that a pair of well‐defined quasi‐reversible redox peaks appeared with the formal potential (E0′) located at ?0.251 V (vs. SCE) at pH 7.0 phosphate buffer solution (PBS), which was the characteristic of heme Fe(III)/Fe(II) redox couples. Electrochemical parameters of the Hb in the film such as the electron transfer coefficient (α), the electron transfer number (n) and the standard electron transfer rate constant (ks) were estimated as 0.469, 0.87 and 0.635 s?1, respectively.  相似文献   

20.
Reported here is the design of an electrochemical sensor for dopamine (DA) based on a screen print carbon electrode modified with a sulphonated polyether ether ketone-iron (III) oxide composite (SPCE-Fe3O4/SPEEK). L. serica leaf extract was used in the synthesis of iron (III) oxide nanoparticles (Fe3O4NPs). Successful synthesis of Fe3O4NP was confirmed through characterization using Fourier transform infrared (FTIR), ultraviolet–visible light (UV–VIS), X-ray diffractometer (XRD), and scanning electron microscopy (SEM). Cyclic voltammetry (CV) was used to investigate the electrochemical behaviour of Fe3O4/SPEEK in 0.1 M of phosphate buffer solution (PBS) containing 5 mM of potassium ferricyanide (III) solution (K3[Fe(CN)6]). An increase in peak current was observed at the nanocomposite modified electrode SPCE-Fe3O4/SPEEK) but not SPCE and SPCE-Fe3O4, which could be ascribed to the presence of SPEEK. CV and square wave voltammetry (SWV) were employed in the electroxidation of dopamine (0.1 mM DA). The detection limit (LoD) of 7.1 μM and 0.005 μA/μM sensitivity was obtained for DA at the SPCE-Fe3O4/SPEEK electrode with concentrations ranging from 5–50 μM. LOD competes well with other electrodes reported in the literature. The developed sensor demonstrated good practical applicability for DA in a DA injection with good resultant recovery percentages and RSDs values.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号