首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A capillary gas chromatographic-mass spectrometric method for the simultaneous determination of cortisol, cortisone, prednisolone and prednisone in human plasma is described. [1,1,19,19,19-2H5]Cortisol, [1,1,19,19,19-2H5]cortisone, [1,19,19,19-2H4]prednisolone and [1,19,19,19-2H4]prednisone were used as internal standards. Formation of the bismethylenedioxy-3-heptafluoro-n-butyryl (BMD-HFB) derivatives made possible the separation of the four corticosteroids with good gas chromatographic behaviour. The new double derivatization has been demonstrated to be of value for sensitive and selective quantification by this technique. Detection was performed by monitoring the molecular ion (M+) of the BMD-HFB derivatives for cortisone and prednisolone, the [M - 18]+ ion for cortisol, and the [M - 30]+ ion for prednisone. The method requires no complex corrections for contributions and provides good accuracy and precision.  相似文献   

2.
A sensitive microElution solid-phase extraction (SPE) liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for the determination of M+4 stable isotope labeled cortisone and cortisol in human plasma. In this method, M+4 cortisone and M+4 cortisol were extracted from 0.3 mL of human plasma samples using a Waters Oasis HLB 96-well microElution SPE plate using 70 microL methanol as the elution solvent, and chromatographed on a Waters Symmetry C18 column (4.6 x 50 mm, 3.5 microm). M+9 cortisone and M+9 cortisol were used as the internal standards. A PE Sciex API 4000 tandem mass spectrometer interfaced with the liquid chromatograph via a turboionspray source was used for mass analysis and detection. The selected reaction monitoring (SRM) of precursor --> product ion transitions were monitored at m/z 365.2 [M+H](+) --> 167.0 and at m/z 367.3 [M+H](+) --> 125.1 for M+4 cortisone and M+4 cortisol, respectively. The lower limit of quantitation was 0.1 ng mL(-1) and the linear calibration range was from 0.1 to 100 ng mL(-1) for both analytes. This method demonstrated to be very reproducible and reliable.  相似文献   

3.
A capillary gas chromatographic-mass spectrometric method for the simultaneous determination of androstenedione and testosterone in human plasma using [19,19,19-2H3]androstenedione and [19,19,19-2H3]testosterone as internal standards is described. For calculation of plasma androstenedione and testosterone, peak heights were measured by selected-ion monitoring of the molecular ions of the heptafluorobutyryl derivatives of androstenedione and [2H3]androstenedione (m/z 482 and 485) and of testosterone and [2H3]testosterone (m/z 680 and 683). The isotope dilution method needed no complex corrections for contributions and provides a sensitive and reliable technique with good accuracy, precision and reproducibility.  相似文献   

4.
Cortisol homeostasis is implicated in hypertension and metabolic syndrome. Two enzymes modulate cortisol availability; 11β-hydroxysteroid dehydrogenase type 1 (11β-HSD1) preferentially converts inactive cortisone to cortisol, whereas 11β-hydroxysteroid dehydrogenase type 2 (11β-HSD2) converts cortisol to cortisone. In contrast, 5α and 5β reductases inactivate cortisol by conversion to its tetrahydrometabolites: tetrahydrocortisol, allo-tetrahydrocortisol and tetrahydrocortisone. A subtle local increase in cortisol can be detected by measuring 24-h urine metabolites, LC–MS/MS being the reference method. The 11β-HSD2 activity is assessed based on the cortisol/cortisone ratio, and the 11β-HSD1 activity on the (tetrahydrocortisol + allo-tetrahydrocortisol)/tetrahydrocortisone ratio. To better understand hypertension and/or metabolic syndrome pathogenesis a method for simultaneous determination of cortisol, cortisone, tetrahydrocortisol, allo-tetrahydrocortisol and tetrahydrocortisone was developed and validated in an LC coupled with the new detector AB Sciex QTrap® 4500 tandem mass spectrometer. The steroids were extracted from 1 mL urine, using cortisol-D4 as internal standard. The quantification range was 0.1–120 ng/mL for cortisol and cortisone, and 1–120 ng/mL for tetrahydrometabolites, with >89 % recovery for all analytes. The coefficient of variation and accuracy was <10 %, and 85–105 %, respectively. Our LC–MS/MS method is accurate and reproducible in accordance with Food and Drug Administration guidelines, showing good sensitivity and recovery. This method allows the assessment of 11β-HSD2 and 11β-HSD1 activities in a single analytical run providing an innovative tool to explain etiology of misclassified essential hypertension and/or metabolic syndrome.  相似文献   

5.
A capillary gas chromatographic-mass spectrometric method for the determination of cortisol in human plasma using cortisol M + 5 as an internal standard is described. For calculation of plasma cortisol, peak areas were measured by selected-ion monitoring of the characteristic fragment ions of the dimethoxime-tri (trimethylsilyl) derivatives of cortisol and cortisol M + 5 (m/z 605 and 610, respectively). The inter- and intra-assay coefficients of variation for plasma sample were 3.07 and 1.77%, respectively. The method needed no complex corrections for contributions and provides a sensitive and reliable technique with good accuracy, precision and reproducibility.  相似文献   

6.
A new and reliable mass spectrometric method using an isotope dilution method in combination with matrix-assisted laser desorption/ionization-triple quadrupole tandem mass spectrometry (ID-MALDI-QqQ-MS/MS) has been developed and validated for the determination of concentrations of the antiretroviral drug tenofovir (TNV) in plasma from HIV-infected adults. The advantage of this new method is that (1) the method is ultrafast and (2) can be applied for high-throughput measurement of TNV in plasma. The method is based on a simple plasma deproteinization step in combination with the use of [adenine-(13) C(5) ]-TNV as the internal standard. TNV and [adenine-(13) C(5) ]-TNV were monitored by multiple reaction monitoring using the transition m/z 288.0 → 176.2 and m/z 293.2 → 181.2 for TNV and [adenine-(13) C(5) ]-TNV, respectively. The method was validated according to the most recent FDA guidelines for the development and validation of (new) bio-analytical assays. Validated method parameters were: linearity, accuracy, precision and stability of the method. The lowest limit of quantification was 0.10 μmol/l, whereas the limit of detection determined at a signal-to-noise ratio (S/N = 3:1) in pooled drug free human control plasma was 0.04 μmol/l. The validated method was successfully applied and tested for its clinical feasibility by the analysis of plasma samples from selected HIV-infected adults receiving the prodrug tenofovir disoproxil fumarate. Observed plasma TNV concentrations ranged between 0.11 and 0.76 μmol/l and measured plasma TNV concentrations were within the therapeutically relevant concentration range.  相似文献   

7.
Ethyl sulfate (EtS)--a new direct marker for ethanol intake besides ethyl glucuronide (EtG) and others--was detected in urine samples by electrospray ionization tandem mass-spectrometry (LC-ESI-MS/MS). Ethyl sulfate sodium salt was used for method development, yielding a precursor [M - H]- m/z 125 and product ions m/z 97 [HSO4]- and m/z 80 [SO3]-. Pentadeuterated EtS (D5-EtS) was synthesized by esterification of sulfuric acid with anhydrous hexadeutero ethanol ([M - H]- m/z 130, product ions m/z 98 [DSO4]- and m/z 80 [SO3]-). After addition of D5-EtS and D5-EtG, urine samples were analyzed by direct injection into the gradient LC-MS/MS system. Analysis was performed in accordance with forensic guidelines for confirmatory analysis using one precursor and two product ions. EtS has been detected (in addition to EtG) in the urine samples of nine volunteers after drinking sparkling wine containing between 9 and 49 g of ethanol. Both EtS and EtG could be detected up to 36 h after consumption of alcohol. The excretion profile was found to be similar to that of EtG. No EtS was found in teetotalers' urine samples. Method validation parameters are presented. EtS was stable in urine upon storage up to twenty days at room temperature. In addition to EtG, EtS can be used to detect recent alcohol consumption, thus providing a second marker for the time range of up to approximately one day after elimination of ethanol from urine samples. The determination of EtS can be used in addition to EtG as proof of ethanol consumption in workplace monitoring programs.  相似文献   

8.
Yessotoxins are a group of large polyether toxins, produced by marine dinoflagellates, which cause widespread contamination of filter-feeding shellfish. A new, sensitive liquid chromatography-mass spectrometry (LC-MS) method has been developed for the determination of yessotoxin (YTX) and 45-hydroxy-yessotoxin (45-OHYTX), a major metabolite in shellfish. The LC system was coupled, via an electrospray ionisation (ESI) source, to an ion-trap MS in negative mode. The molecular related ion species at m/z 1141 [M-2Na+H]- was used as the parent ion for multiple MS experiments. MS-MS and MS3 gave major fragment ions at m/z 1061 [1141-SO3H]- and m/z 945 [1061-C9H12O]-. Predominant ions, that are due to the fragmentation of the backbone structure of YTXs, were observed at the MS4 stage. Reversed-phase LC using a C16 amide column was preferable to C18 phases for the separation of YTX and 45-OHYTX. Optimum calibration and reproducibility data were obtained for YTX using LC-MS-MS; r 2=0.9960, RSD < or = 6.3% at 0.25 microg YTX/g (n=5). The detection limit (S/N=3) was 30 pg YTX on-column which corresponded to 3 ng/g shellfish tissue.  相似文献   

9.
Complications with the gas chromatographic analysis of steroids prompted the use of alternative techniques for their identification. High-performance liquid chromatography/mass spectrometry with atmospheric pressure ionization allowed the collection of data for structural identification of these compounds. The objective of this study was to investigate the up-front collision-induced dissociation (UFCID) electrospray ionization (ESI) mass spectra of testosterone and monohydroxylated testosterones. The positive ion UFCID ESI mass spectrum of testosterone showed three significant ions at m/z 97, 109 and 123. The relative abundance of these ions in the UFCID ESI mass spectra of monohydroxylated testosterones varied with the position of the hydroxy group. Statistical data allowed the prediction of hydroxy group position on testosterone by evaluation of the relative abundance of the m/z 97, 109, 121 and 123 ions. Data from the ESI mass spectral analysis of testosterone in a deuterated solvent and from the analysis of cholestenone and 4-androstene-3 beta, 17 beta-diol indicated that the initial ionization of testosterone occurred at the 3-one position. CID parent ion monitoring analyses of the m/z 97, 109 and 123 ions indicated that each resulted from different fragmentation mechanisms and originated directly from the [M + H]+ parent ion. The elemental composition of these fragment ions is proposed based on evidence gathered from the CID analysis of the pseudo-molecular ions of [1,2-2H2]-, [2,2,4,6,6-2H5]-, [6,7-2H2]-, [7-2H]-, [19,19,19-2H3]- and [3,4-13C2]testosterone. The structure and a possible mechanism of formation of the m/z 109 and 123 ions is presented. The results of this study advance the understanding of the mechanisms of collision-induced fragmentation of ions.  相似文献   

10.
Quantitative determination of tertatolol concentrations in plasma and urine was performed by gas chromatography-mass spectrometry in the chemical-ionization mode with ammonia after successive extractions of the beta-blocking drug in alkaline, acid and final alkaline medium. [2H9]Tertatolol, isotopically stable under the operating conditions employed, was used as an internal standard, thus allowing quantities of 1 ng/ml to be specifically determined. Overall analytical error was less than 10%. Prior to isothermal chromatography at 240 degrees C on a column packed with 3% SE-30, both compounds were silylated with bis(trimethylsilyl)trifluoroacetamide. Detection was performed by monitoring the quasimolecular ions of tertatolol, m/z 368 and m/z 377, for the [2H9]tertatolol in the chemical-ionization mode with ammonia. The calibration curves obtained had linear characteristics for the concentration range 1-1125 ng/ml.  相似文献   

11.
A method for the assay of delta 1-tetrahydrocannabinol (delta 1-THC) in plasma using combined gas chromatography-mass spectrometry with metastable ion monitoring is described. delta 1-THC was extracted with hexane and the extracts were methylated with diazomethane to shift the peaks produced by endogenous plasma constituents away from the cannabinoid region. The delta 1-THC was then converted into its trimethylsilyl derivative and quantitated using the metastable ion at m/z 371 formed in the M+ leads to [M - CH3]+ transition with [1",1",2",2"-2H4]cannabinol as the internal standard. delta 1-THC could be measured to 5 pg/ml in plasma. This assay is 20-100 times more sensitive than existing assays and has the advantage of not needing the usual extensive purification step.  相似文献   

12.
Cortisol is an important glucocorticoid that regulates many physiological pathways by activating various intracellular receptors. The type 1 isozyme of 11beta-hydroxysteroid dehydrogenase (11beta-HSD1) functions in vivo predominantly as a reductase by converting cortisone into cortisol. A high-throughput liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed to screen for inhibitors of 11beta-HSD1 by monitoring cortisol and cortisone simultaneously. The injection cycle time can be as fast as 1 min/sample, making it amenable to the analysis of large numbers of the cell-assay samples in the screening of 11beta-HSD inhibitors. The reductase and dehydrogenase activities of 11beta-HSD1 are assessed separately.  相似文献   

13.
The degradation of the dye indigo carmine in aqueous solution induced by two oxidative processes (H(2)O(2)/iodide and O(3)) was investigated. The reactions were monitored by electrospray ionization mass spectrometry in the negative ion mode, ESI(-)-MS, and the intermediates and oxidation products characterized by ESI(-)-MS/MS. Both oxidative systems showed to be highly efficient in removing the color of the dye aqueous solutions. In the ESI(-)-MS of the indigo carmine solution treated with H(2)O(2) and H(2)O(2)/iodide, the presence of the ions of m/z 210 (indigo carmine in its anionic form, 1), 216, 226, 235, and 244 was noticeable. The anion of m/z 235 was proposed to be the unprecedented hydroperoxide intermediate 2 formed in solution via an electrophilic attack by hydroxyl and hydroperoxyl radicals of the exocyclic C=C bond of 1. This intermediate was suggested to be rapidly converted into the anionic forms of 2,3-dioxo-1H-indole-5-sulfonic acid (3, m/z 226), 2-amino-alpha-oxo-5-sulfo-benzeneacetic acid (4, m/z 244), and 2-amino-5-sulfo-benzoic acid (5, m/z 216). In the ESI(-)-MS of the indigo carmine solution treated with O(3), two main anions were detected: m/z 216 (5) and 244 (4). Both products were proposed to be produced via an unstable ozonide intermediate. Other anions in this ESI(-) mass spectrum were attributed to be [4 - H + Na](-) of m/z 266, [4 - H](2-) of m/z 121.5, and [5 - H](2-) of m/z 107.5. ESI-MS/MS data were consistent with the proposed structures for the anionic products 2-5.  相似文献   

14.
An isotopic modification of Sanger's method for identifying peptide N-termini has been developed to assist peptide sequencing by tandem mass spectrometry. Tryptic peptides, such as Val-His-Leu-Thr-Pro-Val-Glu-Lys, are derivatized with an equimolar mixture of 2,4-dinitrofluorobenzene and [2H3]2,4-dinitrofluorobenzene. Under optimized derivatization conditions, the alpha-amino group could be derivatized while the epsilon-amine of the lysine side chain and the imidazole of histidine remained underivatized. The alpha-dinitrophenyl modified peptides were characterized by electrospray ionization-tandem mass spectrometry (ESI-MS/MS) and liquid chromatography (LC)-ESI-MS. The [M + H]+ ions showed a doublet pattern with a delta m/z of 3 and the [M + 2H]2+ ions were recognized as doublets with a delta m/z of 1.5. MS/MS was employed where both isotopic [M + 2H]2+ ions were alternately subjected to collision-induced dissociation in the second quadrupole. Fragmentation in the ionization source generated identical product ion patterns that were observed during fragmentation in the second quadrupole. In the product ion mass spectra, the N-terminal a and b ions (no c ion observed) are doublets with a delta m/z of 3 or 1.5, while the C-terminal y and z ions (no x ion observed) are singlets appearing at identical masses. Thus, the product ions containing the N-terminus derivatized with a dinitrophenyl group are unequivocally distinguished from the product ions containing the C-terminus. The dinitrophenyl modification generally enhanced the production of a and b ions without diminishing y and z ion yields.  相似文献   

15.
The unimolecular dissociation reactions of the methylhydrazine (MH) and tetramethylhydrazine (TMH) radical cations have been investigated using tandem mass spectrometry and threshold photoelectron photoion coincidence spectroscopy in the photon energy ranges 9.60-31.95 eV (for the MH ion) and 7.74-29.94 eV (for the TMH ion). Methylhydrazine ions (CH3NHNH2(+*)) have three low-energy dissociation channels: hydrogen atom loss to form CH2NHNH2(+) (m/z 45), loss of a methyl radical to form NHNH2(+) (m/z 31), and loss of methane to form the fragment ion m/z 30, N2H2(+*). Tetramethylhydrazine ions only exhibit two dissociation reactions near threshold: that of methyl radical loss to form (CH3)2NNCH3(+) (m/z 73) and of methane loss to form the fragment ion m/z 72 with the empirical formula C3H8N2(+*). The experimental breakdown curves were modeled with Rice-Ramsperger-Kassel-Marcus theory, and it was found that, particularly for methyl radical loss, variational transition state theory was needed to obtain satisfactory fits to the data. The 0 K enthalpies of formation (delta(f)H0) for all fragment ions (m/z 73, m/z 72, m/z 45, m/z 31, and m/z 30) have been determined from the 0 K activation energies (E0) obtained from the fitting procedure: delta(f)H0[(CH3)2NNCH3(+)] = 833 +/- 5 kJ mol(-1), delta(f)H0 [C3H8N2(+*)] = 1064 +/- 5 kJ mol(-1), delta(f)H0[CH2NHNH2(+)] = 862 +/- 5 kJ mol(-1), delta(f)H0[NHNH2(+)] = 959 +/- 5 kJ mol(-1), and delta(f)H0[N2H2(+*)] = 1155 +/- 5 kJ mol(-1). The breakdown curves have been measured from threshold up to h nu approximately 32 eV for both hydrazine ions. As the photon energy increases, other dissociation products are observed and their appearance energies are reported.  相似文献   

16.
A simple and sensitive method was developed for the simultaneous quantification of harpagoside and cinnamic acid in rat plasma using high-performance liquid chromatography system coupled to a negative ion electrospray mass spectrometric analysis. The plasma sample preparation was a simple deproteinization by the addition of two volumes of acetonitrile. The analytes were separated on an Intersil C8-3 column (2.1 mm i.d.x250 mm, 5 microm) with acetonitrile-5 mm ammonium formate aqueous solution (60:40, v/v) as mobile phase at a flow-rate of 0.2 mL/min. Detection was performed on a quadrupole mass spectrometer equipped with electrospray ionization (ESI) source operated under selected ion monitoring (SIM) mode. [M+HCOO]- at m/z 539 for harpagoside, [M-H]- at m/z 147 for cinnamic acid and [M-H]- at m/z 137 for salylic acid (internal standard) were selected as detecting ions, respectively. The method was validated over the concentration range 7-250 ng/mL for harpagoside and 5-500 ng/mL for cinnamic acid. The lower limits of quantitation for harpagoside and cinnamic acid were 7 and 5 ng/mL, respectively. The intra- and inter-day precisions (RSD%) were within 9.5% and the assay accuracies (RE%) ranged from -5.3 to 3.0% for both analytes. Their average recoveries were greater than 86%. Both analytes were proved to be stable during all sample storage, preparation and analysis procedures. The method was successfully applied to the pharmacokinetic study of harpagoside and cinnamic acid following oral administration of Radix Scrophulariae extract to rats.  相似文献   

17.
In this study, we developed a method for the determination of Penicillium griseofulvum‐oriented pyripyropene A (PPPA), a selective inhibitor of acyl‐coenzyme A:cholesterol acyltransferase 2, in mouse and human plasma and validated it using liquid chromatography–tandem mass spectrometry. Pyripyropene A (PPPA) and an internal standard, carbamazepine, were separated using a Xterra MS C18 column with a mixture of acetonitrile and 0.1% formic acid as the mobile phase. The ion transitions monitored in positive‐ion mode [M + H]+ of multiple‐reaction monitoring (MRM) were m/z 148.0 from m/z 584.0 for PPPA and m/z 194.0 from m/z 237.0 for the internal standard. The detector response was specific and linear for PPPA at concentrations within the range from 1 to 5,000 ng/mL. The intra?/inter‐day precision and accuracy of the method was acceptable by the criteria for assay validation. The matrix effects of PPPA ranged from 97.6 to 104.2% and from 93.3 to 105.3% in post‐preparative mouse and human plasma samples, respectively. PPPA was also stable under various processing and/or handling conditions. Finally, PPPA concentrations in the mouse plasma samples could be measured after intravenous, intraperitoneal, or oral administration of PPPA, suggesting that the assay is useful for pharmacokinetic studies on mice and applicable to human studies.  相似文献   

18.
A new method for the determination of the enrichment of [6,6-2H2]-D-glucose in human plasma by gas chromatography-mass spectrometry (GC-MS) is described. (2,3,4,5,6)-Pentakis-O-trimethylsilyl-O-methyloxime-D-glucose is used as a derivative for the GC measurement. Using GC-MS with electron-impact ionization, the enrichment is measured in the single-ion monitoring mode observing the masses m/z 319 and 321. In contrast to other methods the use of this glucose derivative reduced the amount of plasma needed from 200 to 10 microliters and no chemical ionization equipment is needed for the mass spectrometer.  相似文献   

19.
A method for the analytical determination of sotolon [4,5-dimethyl-3-hydroxy-2(5H)-furanone], maltol [3-hydroxy-2-methyl-4H-pyran-4-one] and free furaneol [2,5-dimethyl-4-hydroxy-3(2H)-furanone] in wine has been developed. The analytes are extracted from 50 ml of wine in a solid-phase extraction cartridge filled with 800 mg of LiChrolut EN resins. Interferences are removed with 15 ml of a pentane-dichloromethane (20:1) solution, and analytes are recovered with 6 ml of dichloromethane. The extract is concentrated up to 0.1 ml and analyzed by GC-ion trap MS. Maltol and sotolon were determined by selected ion storage of ions in the m/z ranges 120-153 and 79-95, using the ions m/z 126 and 83 for quantitation, respectively. Furaneol was determined by non-resonant fragmentation of the m/z 128 mother ion and subsequent analysis of the m/z 81 ion. The detection limits of the method are in all cases between 0.5 and 1 microg l(-1), well below the olfactory thresholds of the compounds. The precision of the method is in the 4-5% range for levels in wine around 20 microg l(-1). Linearity holds at least up to 400 microg l(-1), and is satisfactory in all cases. The recoveries of maltol and sotolon are constant (70 and 64%, respectively) and do not depend on the type of wine. On the contrary, in the case of furaneol, red wines show constant and high recoveries (97%), while the recoveries on white wines range between 30 and 80%. Different experiments showed that this behavior is probably due to the existence of complexes formed between furaneol and sulphur dioxide or catechols. Sensory experiments confirmed that the complexed forms found in white wines are not perceived by orthonasal olfaction, and that the furaneol determined by the method can be considered as the free and odor-active fraction.  相似文献   

20.
A simple, sensitive and rapid high-performance liquid chromatography/negative ion electrospray tandem mass spectrometry method was developed and validated for the assay of fluvastatin in human plasma. Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective [M-H]- ions, m/z 410/348 for fluvastatin and m/z 480/418 for the internal standard. The assay exhibited a linear dynamic range of 2-500 ng/mL for fluvastatin in human plasma. The lower limit of quantification was 2 ng/mL with a relative standard deviation of less than 5%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 1.5 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏