首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Integrated microfluidic cell culture and lysis on a chip   总被引:1,自引:0,他引:1  
We present an integrated microfluidic cell culture and lysis platform for automated cell analysis that improves on systems which require multiple reagents and manual procedures. Through the combination of previous technologies developed in our lab (namely, on-chip cell culture and electrochemical cell lysis) we have designed, fabricated, and characterized an integrated microfluidic platform capable of culturing HeLa, MCF-7, Jurkat, and CHO-K1 cells for up to five days and subsequently lysing the cells without the need to add lysing reagents. On-demand lysis was accomplished by local hydroxide ion generation within microfluidic chambers, releasing both proteinacious (GFP) and genetic (Hoescht-stained DNA) material. Sample proteins exposed to the electrochemical lysis conditions were immunodetectable (p53) and their enzymatic activity (HRP) was investigated.  相似文献   

2.
Zhang-Run Xu  Cui-Hong Liu  Jin Fang 《Talanta》2010,80(3):1088-1093
A novel microfluidic chip integrating an osmosis-based micro-pump was developed and used for perfusion cell culture. The micro-pump includes two sealed chambers, i.e., the inner osmotic reagent chamber and the outer water chamber, sandwiching a semi-permeable membrane. The water in the outer chamber was forced to flow through the membrane into the inner chamber via osmosis, facilitating continuous flow of fluidic zone in the channel. An average flow rate of 0.33 μL min−1 was obtained within 50 h along with a precision of 4.3% RSD (n = 51) by using a 100 mg mL−1 polyvinylpyrrolidone (PVP) solution as the osmotic driving reagent and a flow passage area of 0.98 cm2 of the semi-permeable membrane. The power-free micro-pump has been demonstrated to be pulse-free offering stable flow rates during long-term operation. The present microfluidic chip has been successfully applied for the perfusion culture of human colorectal carcinoma cell by continuously refreshing the culture medium with the osmotic micro-pump. In addition, in situ cell immunostaining was also performed on the microchip by driving all the reagent zones with the integrated micro-pump.  相似文献   

3.
Jain A  Munn LL 《Lab on a chip》2011,11(17):2941-2947
Blood cells naturally auto-segregate in postcapillary venules, with the erythrocytes (red blood cells, RBCs) aggregating near the axis of flow and the nucleated cells (NCs)--which include leukocytes, progenitor cells and, in cancer patients, circulating tumor cells--marginating toward the vessel wall. We have used this principle to design a microfluidic device that extracts nucleated cells (NCs) from whole blood. Fabricated using polydimethylsiloxane (PDMS) soft lithography, the biomimetic cell extraction device consists of rectangular microchannels that are 20-400 μm wide, 11 μm deep and up to 2 cm long. The key design feature is the use of repeated expansions/contractions of triangular geometry mimicking postcapillary venules, which enhance margination and optimize the extraction. The device operates on unprocessed whole blood and is able to extract 94 ± 4.5% of NCs with 45.75 ± 2.5-fold enrichment in concentration at a rate of 5 nl s(-1). The device eliminates the need to preprocess blood via centrifugation or RBC lysis, and is ready to be implemented as the initial stage of lab-on-a-chip devices that require enriched nucleated cells. The potential downstream applications are numerous, encompassing all preclinical and clinical assays that operate on enriched NC populations and include on-chip flow cytometry (A. Y. Fu et al., Anal. Chem., 2002, 74, 2451-2457; A. Y. Fu et al., Nat. Biotechnol., 1999, 17, 1109-1111), genetic analyses (M. M. Wang et al., Nat. Biotechnol., 2005, 23, 83-87; L. C. Waters et al., Anal. Chem., 1998, 70, 5172-5176) and circulating tumor cell extraction (S. Nagrath et al., Nature, 2007, 450, 1235-1241; S. L. Stott et al., Proc. Natl. Acad. Sci. U. S. A., 2010, 18392-18397; H. K. Lin et al., Clin. Cancer Res., 2010, 16, 5011-5018).  相似文献   

4.
高健  殷学锋  方肇伦 《分析试验室》2003,22(Z1):373-374
单细胞分析对重大疾病的早期诊断等方面有重要意义[1].微流控分析芯片的网络结构和微米级的通道尺寸适合于单细胞进样、溶膜和分离分析.但目前的报道主要集中在细胞培养、计数和筛选[2].我们在十字通道微流控芯片上,通过调节储液池的液面高度和细胞悬液密度,使单细胞逐个通过芯片进样通道和分离通道之间的区域,再结合控制电渗流方向,使单细胞固定在分离通指定位置,然后用电泳缓冲液结合高电场实现细胞快速溶膜,接着进行电泳分离和LIF检测.实现了单个血红细胞内谷胱甘肽(GSH)的高效分离及定量分析.  相似文献   

5.
Gao J  Yin XF  Fang ZL 《Lab on a chip》2004,4(1):47-52
A microfluidic system was developed for the analysis of single biological cells, with functional integration of cell sampling, single cell loading, docking, lysing, and capillary electrophoretic (CE) separation with laser induced fluorescence (LIF) detection in microfabricated channels of a single glass chip. Channels were 12 microm deep and 48 microm wide, with a simple crossed-channel design. The effective separation channel length was 35 mm. During sampling with a cell suspension (cell population 1.2 x 10(5) cells per mL in physiological salt solution), differential hydrostatic pressure (created by adjusting liquid levels in the four reservoirs) was used to control cell flow exclusively through the channel crossing. Single cell loading into the separation channel was achieved by electrophoretic means by applying a set of potentials at the four reservoirs, counteracting the hydrostatic flow. A special docking (adhering) procedure for the loaded cell was applied before lysis by repeatedly connecting and disconnecting a set of low potentials, allowing precise positioning of the cell within the separation channel. Cell lysis was then effected within 40 ms under an applied CE separation voltage of 1.4 kV (280 V cm(-1)) within the working electrolyte (pH 9.2 borate buffer) without additional lysates. The docked lysing approach reduced dispersion of released intracellular constituents, and significantly improved the reproducibility of CE separations. Glutathione (GSH) was used as a model intracellular component in single human erythrocyte cells. NDA derivatized GSH was detected using LIF. A throughput of 15 samples h(-1), a retention time precision of 2.4% RSD was obtained for 14 consecutively injected cells. The average cellular concentration of GSH in human erythrocytes was found to be 7.2 [times] 10(-4)+/- 3.3 x 10(-4) M (63 +/- 29 amol per cell). The average separation efficiency for GSH in lysed cells was 2.13 x 10(6)+/- 0.4 x 10(6) plates per m, and was about a factor of 5 higher than those obtained with GSH standards using pinched injection.  相似文献   

6.
Perfluorinated carboxylic acids (PFCAs), amphiphiles of anthropogenic origin, are spread worldwide throughout the environment. This work deals with their zone electrophoresis (ZE) separation on a chip with coupled columns and integrated conductivity detection. Analogies with the electrophoretic behavior of PFCAs and fatty acids were employed in a search for electrolyte conditions suitable for their separation. ZE separations in the water-ethanol electrolyte systems, based on differences in the ionic mobilities of the anions of PFCAs, provided favorable resolution and detection conditions of the homologues containing up to 10 carbon atoms in the alkyl chain. Concentration limits of detection of 0.3-6.5 micromol/L were attained for PFCAs (loaded by a 900 nL volume sample injection channel of the chip) under these separation conditions. The material of which the chip was made [poly(methylmethacrylate)] restricted its use in investigations of the separations of higher PFCA homologues as it was damaged by ethanolic and/or methanolic background electrolyte solutions required in experiments with these amphiphilic compounds.  相似文献   

7.
The use of a poly(methylmethacrylate) chip, provided with a pair of on-line coupled separation channels and on-column conductivity detectors, to isotachophoresis (ITP) separations of optical isomers was investigated. Single-column ITP, ITP in the tandem-coupled columns, and concentration-cascade ITP in the tandem-coupled columns were employed in this investigation using tryptophan enantiomers as model analytes. Although providing a high production rate (about 2 pmol of a pure tryptophan enantiomer separated per second), single-column ITP was found suitable only to the analysis of samples containing the enantiomers at close concentrations. A 94-mm separation path in ITP with the tandem-coupled separation channels made possible a complete resolution of a 1.5 nmol amount of the racemic mixture of the enantiomers. However, this led only to a moderate extension of the concentration range within which the enantiomers could be simultaneously quantified. The best results in this respect were achieved by using a concentration-cascade of the leading anions in the tandem-coupled separation channels. Here, a high production rate, favored in the first separation channel, was followed by the ITP migration of the enantiomers in the second channel under the electrolyte conditions enhancing their detectabilities. In dependence on the migration configuration of the enantiomers, this technique made possible their simultaneous determinations when their ratios in the loaded sample were 35:1 or less (D-tryptophan a major constituent) and 70:1 or less (L-tryptophan a major constituent).  相似文献   

8.
This paper reports a system for three-dimensional electrochromatography in a chip format. The steps involved included trypsin digestion, copper(II)-immobilized metal affinity chromatography [Cu(II)-IMAC] selection of histidine-containing peptides, and reversed-phase capillary electrochromatography of the selected peptides. Trypsin digestion and affinity chromatography were achieved in particle-based columns with a microfabricated frit whereas reversed-phase separations were executed on a column of collocated monolithic support structures. Column frits were designed to maintain constant cross sectional area and path length in all channels and to retain particles down to a size of 3 microm. Cu(II)-IMAC selection of histidine-containing peptides from standard peptide mixtures and protein digests followed by reversed-phase chromatography of the selected peptides was demonstrated in the electrochromatography mode. The possibility to run a comprehensive proteomic analysis by combining trypsin digestion, affinity selection, and a reversed-phase separation on chips was shown using fluorescein isothiocyanate-labeled bovine serum albumin as an example.  相似文献   

9.
This paper reports a microfluidic method of continuous separation of marine algae and particles by DC dielectrophoresis. The locally non-uniform electric field is generated by an insulating PDMS triangle hurdle fabricated within a PDMS microchannel. Both the particles and algae are subject to negative DEP forces at the hurdle where the gradient of local electric-field strength is the strongest. The DEP force acting on the particle or the algae depends on particles’ or algae’s volume, shape and dielectric properties. Thus the moving particles and algae will be repelled to different streamlines when passing the hurdle. In this way, combined with the electroosmotic flow, continuous separation of algae of two different sizes, and continuous separation of polystyrene particles and algae with similar volume but different shape were achieved. This first demonstration of DC DEP separation of polystyrene particles and algae with similar sizes illustrates the great influence of dielectric properties on particle separation and potentials for sample pretreatment.  相似文献   

10.
A poly(methylmethacrylate) chip, provided with two separation channels in the column-coupling (CC) arrangement and on-column conductivity detection sensors and intended, mainly, to isotachophoresis (ITP) and ITP-capillary zone electrophoresis (CZE) separations was developed recently. The present work was aimed at assessing its performance relevant to the detection and quantitation of the ITP analytes. Hydrodynamic (HDF) and electroosmotic (EOF) flows of the solution in the separation compartment of the CC chip were suppressed and electrophoresis was a dominant transport process in the ITP separations with model analytes carried out in this context. When the surfaces of the detection electrodes of the conductivity sensors on the chip were appropriately cleaned qualitative indices of the test analytes [relative step heights (RSHs)], provided by a particular detection sensor, agreed within 1% (expressed via RSDs of the RSH values). Their long-term reproducibilities for one sensor, as estimated from 70 ITP runs repeated in 5 days, were 2% or less. Sensor-to-sensor and chip-to-chip fluctuations of the RSH values for the test analytes were 2.5% or less. In addition, experimentally obtained RSH values agreed well with those predicted by the calculations based on the ITP steady-state model. Reproducibilities of the migration velocities attainable on the CC chips with suppressed EOF and HDF, assessed from the migration time measurements of the ITP boundary between well-defined positions on the separation channels of the chips (140 repeated runs on three chips), ranged from 1.4 to 3.3% for the migration times in the range of 100-200 s. Within-day repeatabilities of the time-based zone lengths for the test analytes characterized 2% RSDs, while their day-to-day repeatabilities were less than 5%. Chip-to-chip reproducibilities of the zone lengths, assessed from the data obtained on three chips for 100 ITP runs, were 5-8%.  相似文献   

11.
Concentration gradient and fluid shear stress(FSS) for cell microenvironment were investigated through microfluidic technology. The Darcy–Weisbach equation combined with computational fluid dynamics modeling was exploited to design the microfluidic chip, and the FSS distribution on the cell model with varying micro-channels(triangular, conical, and elliptical). The diffusion with the incompressible laminar flow model by solving the time-dependent diffusion–convection equation was applied to simu...  相似文献   

12.
Zhang L  Yin X 《Electrophoresis》2007,28(8):1281-1288
A simple and powerful microfluidic array chip-based electrophoresis system, which is composed of a 3-D microfluidic array chip, a microvacuum pump-based negative pressure sampling device, a high-voltage supply and an LIF detector, was developed. The 3-D microfluidic array chip was fabricated with three glass plates, in which a common sample waste bus (SW(bus)) was etched in the bottom layer plate to avoid intersecting with the separation channel array. The negative pressure sampling device consists of a microvacuum air pump, a buffer vessel, a 3-way electromagnet valve, and a vacuum gauge. In the sample loading step, all the six samples and buffer solutions were drawn from their reservoirs across the injection intersections through the SW(bus) toward the common sample waste reservoir (SW(T)) by negative pressure. Only 0.5 s was required to obtain six pinched sample plugs at the channel crossings. By switching the three-way electromagnetic valve to release the vacuum in the reservoir SW(T), six sample plugs were simultaneously injected into the separation channels by EOF and electrophoretic separation was activated. Parallel separations of different analytes are presented on the 3-D array chip by using the newly developed sampling device.  相似文献   

13.
Microfluidic devices are increasingly used to perform biological experiments on a single-cell basis. However, long-term stability of cell positions is still an issue. A novel biocompatible method for cell entrapment and release on a microchip is presented. It is based on the controlled formation of an alginate hydrogel by bringing two laminar flows of alginate and calcium ions in the range of 2 mM to 40 mM into contact. The resulting growth of a gel bar is used to enclose and immobilize yeast cells. Adding ethylenediaminetetraacetic acid (EDTA) to the alginate solution allows for control of the hydrogel growth, and by varying the ratio of Ca(2+) to EDTA concentrations gel growth or gel shrinkage can be induced at will. Trapped cells are released during shrinkage of the gel. The trapping efficiency for different cell speeds is investigated and the properties of gel growth are discussed using a diffusion model. Precise positioning of a single cell is demonstrated. The technique presented allows not only the reversible immobilization of cells under gentle conditions but also offers the potential of long-term cell cultures as shown by on-chip incubation of yeast cells. The procedure may provide a simple and fully biocompatible technique for a multitude of innovative experiments on cells in microsystems.  相似文献   

14.
In this paper, we present an approach to perform electrochromatographic separations on poly(dimethylsiloxane) chips: a fused-silica capillary containing a stationary phase was introduced directly into the chip. This approach would offer great flexibility since capillary modification methods are well known, and thus, with this kind of chip, different microfluidic devices having various functions could be prepared. Electrophoretic separations were first achieved by integrating an empty capillary into the chip to evaluate the analytical performances of this system. They were compared to those obtained with a classical chip. Finally, an electrochromatographic separation involving a capillary containing a hexyl acrylate-based monolith was performed. These preliminary results show this approach to be promising.  相似文献   

15.
The use of a poly(methylmethacrylate) chip, provided with two separation channels in the column-coupling (CC) arrangement and on-column conductivity detection sensors, to electrophoretic separations of a group of inorganic anions (chloride, nitrate, sulfate, nitrite, fluoride and phosphate) that need to be monitored in various environmental matrices was studied. The electrophoretic methods employed in this study included isotachophoresis (ITP) and capillary zone electrophoresis (CZE) with on-line coupled ITP sample pretreatment (ITP-CZE). Hydrodynamic and electroosmotic flows of the solution in the separation compartment of the CC chip were suppressed and electrophoresis was a dominant transport process in the separations performed by these methods. ITP separations on the chip provided rapid resolutions of sub-nmol amounts of the complete group of the studied anions and made possible rapid separations and reproducible quantitations of macroconstituents currently present in water samples (chloride, nitrate and sulfate). However, concentration limits of detection attainable under the employed ITP separating conditions (2-3 x 10(-5) mol/l) were not sufficient for the detection of typical anionic microconstituents in water samples (nitrite, fluoride and phosphate). On the other hand, these anions could be detected at 5-7 x 10(-7) mol/l concentrations by the conductivity detector in the CZE stage of the ITP-CZE combination on the CC chip. A sample clean-up performed in the ITP stage of the combination effectively complemented such a detection sensitivity and nitrite, fluoride and phosphate could be reproducibly quantified also in samples containing the macroconstituents at 10(4) higher concentrations. ITP-CZE analyses of tap, mineral and river water samples showed that the CC chip offers means for rapid and reproducible procedures to the determination of these anions in water (4-6 min analysis times under our working conditions). Here, the ITP sample pretreatment concentrated the analytes and removed nanomol amounts of the macroconstituents from the separation compartment of the chip within 3-4 min. Both the ITP and ITP-CZE procedures required no or only minimum manipulations with water samples before their analyses on the chip. For example, tap water samples were analyzed directly while a short degassing of mineral water (to prevent bubble formation during the separation) and filtration of river water samples (to remove particulates and colloids) were the only operations needed in this respect.  相似文献   

16.
In this study, an aqueous two‐phase system (ATPS) with PEG and hydroxypropyl starch (HPS) was used to separate monoclonal antibody (mAb) from Chinese hamster ovary cell culture supernatant. The phase diagram of the PEG/HPS ATPS was determined, and the effects of NaCl addition were investigated. The results showed that NaCl addition could lead to a shift of the binodal curve and that phase separation would occur at higher PEG and HPS concentrations. The effects of NaCl addition, pH, and the load of cell supernatant on the partitioning of mAb in a PEG/HPS ATPS were investigated. It was found that with 6% cell supernatant and 15% NaCl addition at pH 6.0, the yield of mAb in the upper phase was 96.7% with a purity of 96.0%. The back‐extraction of mAb with a PEG/phosphate ATPS were also studied, and the results showed that after the two‐step extraction with ATPSs the purity of mAb could reach 97.6 ± 0.5% with a yield of 86.8 ± 1.0%, which was comparable to the purification with Protein A chromatography. These results indicate that the two‐step extraction with PEG/HPS and PEG/phosphate ATPSs might be a promising alternative for the separation of mAb from cell culture supernatant.  相似文献   

17.
A common drawback of paper‐based separation devices is their poor detection limit. In this study, we combined field‐amplified sample stacking with moving reaction boundary electrophoresis on a paper chip with six array channels for the parallel separation and concentration of multiple samples. With a new hyphenated technique, the brown I2 from the Fe3+/I oxidation–reduction reaction emerged near the boundary between the dilute ethylene diamine tetraacetic acid and potassium iodide and highly concentrated KCl solutions. For the separation and concentration of three components, Cr3+, Cu2+, and Fe3+, the Fe3+ detection limit was improved at least 266‐fold by comparing the hyphenated technique with moving reaction boundary electrophoresis. The detection limit of Fe3+ was found to be as low as 0.34 ng (20 μM) on the paper chip. We also demonstrated the analysis of a real sample of four metal ions, with detection limits as follows: 0.16 μg Cr3+, 1.5 μg Ni2+, 0.64 μg Cu2+, and 1.5 μg Co2+. The synergy of field‐amplified sample stacking and moving reaction boundary electrophoresis in the micron paper‐based array channels dramatically improved the detection limit and throughput of paper‐based electrophoresis.  相似文献   

18.
In this work we established differential pulse anodic stripping voltammetry (DPASV) as the tool for analysis of lead in the plant cell culture. For the cultivation procedure, lead in Pb(II)-ethylenediaminetetraacetic acid (Pb-EDTA) chelate has been used. The detection limit of lead was found at 500 pM in phosphate buffer (pH 5.5), and 100 nM in prepared cells intracellular extract (20 pg Pb(II)/mg cells). For determination of cysteine-rich peptides, voltammetry in differential mode (DPV) in cobalt(III)-containing ammonia buffer (Brdicka reaction) was used. In this short communication, we present suitable voltammetric techniques for the physiological study of lead and thiols in plant cell culture.  相似文献   

19.
Under the assumption that separation efficiencies are mainly affected by the velocity of flow-induced circulation due to buffer injection in a pendent drop, this paper describes an analysis of the separation efficiency of a droplet-based magnetically activated cell separation (DMACS) system. To investigate the velocity of the flow-induced circulation, we supposed that numerous flows in a pendent drop could be considered as a “theoretically normalized” flow (or conceptually normalized flow, CNF) based on the Cauchy–Goursat theorem. With the morphological characteristics (length and duration time) of a pendent drop depending on the initial volume, we obtained the velocities of the CNF. By measuring the separation efficiencies for different initial volumes and by analyzing the separation efficiency in terms of the velocity of the CNF, we found that the separation efficiencies (in the case of a low rate of buffer injection; 5 and 15 μl·min-1) are mainly affected by the velocity of the CNF. Moreover, we confirmed that the phenomenological features of a pendent drop cause a fluctuation of its separation efficiencies over a range of specific volumes (initial volumes ranging from 40 to 80 μl), because of the “sweeping-off” phenomenon, that is, positive cells gathered into the positive fraction are forced to move away from the magnetic side by flow-induced circulation due to buffer injection. In addition, from the variation of the duration time, that is, the interval between the beginning of injection of the buffer solution and the time at which a pendent drop detaches, it could also be confirmed that a shorter duration time leads to decrease of the number of positive cells in negative fraction regardless of the rate of buffer injection (5, 15, and 50 μl·min-1). Therefore, if a DMACS system is operated with a 15 μl·min-1 buffer injection flow rate and an initial volume of 80 μl or more, we would have the best efficiency of separation in the negative fraction.  相似文献   

20.
Two acyl and three fluoroacyl derivatives of 32 chiral alcohols have been chromatographed on a GC column coated with octakis(2,6-di-O-n-pentyl-3-O-trifluoroacetyl)- γ-cyclodextrin. Significant differences were observed between the stereoselectivity obtained for the derivatives and that for the underivatized alcohols. Of the derivatives, only the fluoroacylated compounds were separated into enantiomers. Derivatization with fluoroacyl groups reversed the elution order for at least some of the analytes. Stereoselectivity towards simple 2- and 3-hydroxy alkanes and their fluoroacyl derivatives was highest for those alcohols with a four-carbon chain attached to the stereogenic center. For longer-chain fluoroacyl derivative groups stereoselectivity was higher for the 2- and 3-hydroxy alkanes. Differences in stereoselectivity towards alcohols with a methyl-branched alkane chain and their fluoroacyl derivatives was related to the distance between the methyl group and the hydroxyl or fluoroacyl groups. Different degrees of saturation in the carbon chain resulted in differences in stereoselectivity. Thermodynamic data calculated for a number of analytes suggest that the alcohols and trifluoroacetate derivatives are interacting with the stationary phase by similar mechanisms. The stereospecific interaction appears to have a hydrogen bonding or dipole–dipole contribution and some form of steric component, depending upon the shape and/or size of the solute.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号