首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
采用顶空固相微萃取和气相色谱 质谱单离子监测技术,以己二酸二(1 丁基戊基)酯为内标,对水中的己二酸二乙酯、己二酸二异丁酯、己二酸二丁酯、己二酸二(2 丁氧基乙基)酯、己二酸二(乙基己基)酯进行了测定,考察了盐效应、萃取温度、萃取时间和热解吸时间等因素对方法灵敏度的影响。该方法对5种己二酸酯的检测限量为0.0220~5.49μg L,回收率为86.9%~102.0%,相对标准偏差为1.5%~7.3%。  相似文献   

2.
The original solid-phase microextraction (SPME) fibers use an epoxy resin adhesive that releases bisphenol A (BPA) during thermal desorption of the fiber. This adversely affects the method detection limit and accuracy when these products are used for the determination of BPA. In this work, 5 new metal alloy SPME fibers that do not use epoxy resins were compared for the extraction of BPA in water. The performance of the optimum SPME fiber with 60 microm carbowax-polyethylene glycol coating for the headspace SPME of BPA in water was investigated systematically under different extraction conditions. Salt was found to increase the partitioning of BPA from water into the headspace until saturation was reached. Partitioning of BPA from water into the headspace also increased at higher extraction temperatures, as did longer extraction times. However, extraction of BPA from water onto the SPME fiber was not improved for solutions adjusted to pH 2 compared to the unadjusted neutral solutions. The new BPA method showed good linearity over the concentration range of 2.5 to 40 microg/L [correlation coefficient (r2) = 0.995] .The method detection limit for BPA was 0.5 microg/L, while the instrument detection limit was as low as 0.05 microg/L. Good repeatability was observed for BPA at levels of 5 and 20 microg/L with relative standard deviation values < 10%. The automated headspace SPME method developed in this work was used to investigate migration of BPA from polycarbonate bottles into water, and levels of BPA in water ranged from 1.7 to 4.1 microg/L.  相似文献   

3.
A simple, sensitive and rapid method for the determination of diisopropylfluorophosphate (DFP) in rat plasma and brain tissue using headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS) is presented. A 65 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber was selected for sampling. The main parameters affecting the SPME process such as extraction and desorption temperature, extraction and desorption time, salt addition, and fiber preheating time were optimized in each matrix to enhance the extraction efficiency of the method. The lower limits of quantitation for DFP in plasma and brain tissue were 1 ng/mL and 3 ng/g, respectively. The method showed good linearity over the range from 1-100 ng/mL in plasma and 3-300 ng/g in brain tissue with correlation coefficient (R(2)) values higher than 0.995. The precision and accuracy for intra-day and inter-day were less than 10%. The relative recoveries in plasma and brain for DFP were greater than 50%. Stability tests including autosampler and freeze and thaw were also investigated. This validated method was successfully applied to study the neurobehavioral effects of low-level organophosphate exposures. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

4.
A method was developed for the selective determination of Se4+ in drinkable water by solid-phase microextraction (SPME) and gas chromatography/mass spectrometry (GC/MS). Se4+ was selectively derivatized to ethane, 1,1'-selenobis by reaction with sodium tetraethylborate, extracted by the SPME fiber, and determined by GC/MS. Both headspace (HS)-SPME and direct SPME were studied. The method requires only a few milliliters of sample and 20 min for completion. At 2.0 microg/L concentration, the relative standard deviation was 10.1% for HS-SPME and 9.1% for direct SPME. For HS-SPME, the theoretical detection limit was 81 ng/L and 166 ng/L for direct SPME. The recovery rate was 95%. The method was used to determine Se4+ in 10 tap water samples.  相似文献   

5.
The cultivar Anamed (A3) is a hybrid of Artemisia annua with a high content of the secondary metabolite artemisinin, a well-known antimalarial drug. Here we report for the first time the volatile profile of fresh leaves of this hybrid in comparison with that of Artemisia annua L. wild-type species. Evaluation and comparison of the volatile profiles of A. annua genotypes with different content in artemisinin were carried out by headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography/mass spectrometry (GC/MS) that was performed on fresh leaves of the plants under investigation using a polydimethylsiloxane (PDMS) fiber. The chromatograms obtained from hybrids with a high content of artemisinin (A. annua cv. Anamed A3 and A. annua cv. Artemis F2) reveal the total absence of artemisia ketone, one of the major and characteristic compounds of the wild-type A. annua L., along with a significantly lower variety of volatile compounds. In conclusion, HS-SPME coupled with GC/MS is a very useful, non-destructive and efficient method to describe the volatile pattern of Artemisia annua cultivars. It represents a rapid screening method for the evaluation of volatile biomarkers like artemisia ketone, whose absence is typical of artemisinin-rich A. annua cultivars.  相似文献   

6.
A new method of detection of perfluorocarbon molecules (PFCs) in blood sample has been established. After an extraction and pre-concentration step performed by headspace solid-phase microextraction (HS-SPME), the PFCs are detected by gas chromatography-mass spectrometry (GC/MS) with an ion trap mass spectrometer in MS and MS/MS modes. The influence of different parameters on the SPME process is discussed. The limit of detection and the linearity of the procedure have been determined for two PFCs.  相似文献   

7.
This paper describes the development of a headspace solid-phase microextraction gas chromatography-mass spectrometry (HS-SPME-GC-MS) method for determining phthalates in wine. The HS-SPME conditions were thoroughly studied: first, the performance of six fibres at three temperature values and two sample volumes was surveyed by means of a 6 x 3 x 2 multi-factor categorical experimental design. From this study, three fibres - carbowax-divinylbenzene (CW-DVB), polyacrylate (PA) and polydimethylsiloxane-divinylbenzene (PDMS-DVB) - were selected. Then, temperature, sample volume and sodium chloride concentration were optimised using a central composite design and the overall desirability function for each fibre. The optimal values were 70 degrees C, a NaCl concentration of 2.6, 3.6 and 5.5M for PA, CW-DVB and PDMS-DVB fibres, respectively, and sample volumes of 4.0, 3.5 and 3.0 mL. Next, the performance characteristics of the three fibres were obtained and compared. PDMS-DVB fibre showed the best repeatability values followed by CW-DVB. PA fibre was not suitable for diethylhexylphthalate extraction and showed poor repeatability for the heavier phthalates, and was therefore discarded. Finally, the performance of CW-DVB and PDMS-DVB fibres was checked for red, white and rosé wines.  相似文献   

8.
This study proposes the use of deuterated phthalates as internal standards for the accurate determination of phthalates in wine by headspace solid-phase microextraction followed by gas chromatography-mass spectrometry. Unlike other internal standards proposed previously such as benzyl benzoate, deuterated phthalates enabled matrix-error free determinations to be performed without standard addition because statistically equal slopes were obtained for synthetic, white, rose and red wines. The relative standard deviation values under intermediate precision conditions ranged from 0.24 to 4.6%, and detection limits below 35 ng L(-1) were obtained. Recovery values were around 100% in most of cases and the method provided similar results to standard addition. Finally, the method was used to screen phthalate levels in 10 wine samples.  相似文献   

9.
Headspace solid-phase microextraction (SPME) followed by gas chromatography and mass spectrometry was applied for quantification of 41 chemically diverse carbonyl compounds in beer. Therefore, in-solution derivatisation with o-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBHA) combined with SPME was optimised for fibre selection, PFBHA concentration, extraction temperature and time and ionic strength. Afterwards, the method was calibrated and validated successfully and extraction efficiency was compared to sampling with on-fibre derivatisation. In-solution derivatisation enabled the detection of several compounds that were poorly extracted with on-fibre derivatisation such as 5-hydroxymethylfurfural, acrolein, hydroxyacetone, acetoin, glyoxal and methylglyoxal. Others, especially (E)-2-nonenal, were extracted better with on-fibre derivatisation.  相似文献   

10.
A new method is described for the qualitative and quantitative analysis of midazolam, a short-acting 1,4-imidazole benzodiazepine, in human plasma. It involves a plasma deproteinization step, solid-phase microextraction (SPME) of midazolam using an 85-microm polyacrylate fiber, and its detection by gas chromatography/mass spectrometry (GC/MS) in selected ion monitoring (SIM) mode, using pinazepam as internal standard. The assay is linear over a midazolam plasma range of 1.5-300 ng/mL, relative intra- and inter-assay standard deviations at 5 ng/mL are below 7%, and the limit of detection is 1 ng/mL. The method is simple, fast and sufficiently sensitive to be applied in clinical and forensic toxicology as well as for purposes of therapeutic drug monitoring.  相似文献   

11.
A simple solid-phase microextraction (SPME) device, coupled with gas chromatography-flame ionization detection (GC-FID), was developed to detect trace levels of phthalates in environmental water samples. Polyaniline (PANI) was chosen as the sorbent for the SPME device and was electrochemically deposited on a stainless steel wire to achieve high thermal and mechanical stability. The porous structure of the PANI film, characterized by scanning electron microscopy (SEM), suggested large extraction capability. Key parameters were optimized and five phthalates were selected to evaluate the SPME-GC procedures. The method was also applied to the analysis of lake and river water samples. Control experiments were carried out using commercial polyacrylate (PA) fiber. The new PANI-SPME-GC method offers high accuracy, precision and sensitivity and low detection limits. Thus, the method developed could be used as a new way to monitor the trace levels of phthalates in water medium. A possible extraction mechanism was investigated using electrochemical impedance spectroscopy (EIS).  相似文献   

12.
The frying of foods in the home can be a cause of indoor pollution due to the formation of acrolein. The emission of acrolein formed during frying in soybean, corn, canola, sunflower and palm oils was studied. A GC/MS method has been developed to determine acrolein in French fries using SPME as the sampling technique after derivatization with 2,4-dinitrophenylhydrazine (DNPH). Optimum SPME conditions included desorption at 250°C for 2min after an adsorption time of 10min at room temperature. The method presented good resolution, repeatability, detection and quantification limits, and linearity of response. French fries were prepared in five different oils with four frying steps. The results showed that changes in acrolein concentration occurred after frying potatoes in different types of oil and at different frying cycles. Potatoes fried in soybean oil contained the lowest concentration of acrolein. Shoestring potatoes contained a lower concentration of acrolein than potato chips and French fries, respectively, because of the higher surface/volume ratio.  相似文献   

13.
The aim of this study was to create a simple, solventless technique without derivatisation in order to analyze a broad range of volatiles in beer wort. A method was developed using headspace solid-phase microextraction coupled with gas chromatography and mass spectrometry. The procedure was optimised by selection of the appropriate fibre and optimisation of extraction temperature, extraction time, and salting-out. The detection limits were well below the actual wort concentrations of the selected volatiles, ranging from 12 ng/l for linalool to 0.53 microg/l for furfural. Moreover, the procedure showed a good linearity and was applied to the analysis of wort samples taken from a wort boiling process in an industrial brewery.  相似文献   

14.
A method for the determination of trace amounts of the herbicide oxadiazon was developed using headspace solid-phase microextraction (HS-SPME), gas chromatography-mass spectrometry (GC-MS) and selected ion monitoring. It was applied to determine oxadiazon in ground water, agricultural soil, must, wine and human urine samples. To determine oxadiazon in liquid samples, a response surface methodology generated with a Doehlert design was applied to optimize the HS-SPME conditions using a 100 microm polydimethylsiloxane fibre. For the analysis of soil samples, they were mixed with water and the SPME fibre suspended in the headspace above the slurry. Ground water, human urine and must show linear concentration range of application of 0.5-50 ng ml(-1)' with detection limits < or =0.02 ng ml(-1). HS-SPME-GC-MS analysis yielded good reproducibility (RSD values between 6.5 and 13.5%). The method validation was completed with spiked matrix samples. The developed analytical procedure is solvent free, cost effective and fast.  相似文献   

15.
16.
This paper describes a rapid and solvent-free method, microwave-assisted headspace solid-phase microextraction (MA-HS-SPME), for the extraction of six commonly used synthetic polycyclic musks: galaxolide (HHCB), tonalide (AHTN), celestolide (ADBI), traseolide (ATII), cashmeran (DPMI) and phantolide (AHMI) from water samples prior to their determination using gas chromatography-mass spectrometry (GC-MS). The effects of various extraction parameters for the quantitative extraction of these analytes by MA-HS-SPME were systematically investigated and optimized. The analytes in a 20-mL water sample (in a 40-mL sample-vial containing 4 g of NaCl) were efficiently extracted by a polydimethylsiloxane-divinylbenzene (PDMS-DVB) fiber placed in the headspace when the system was microwave irradiated at 180 W for less than 4 min. The limits of detection (LODs) ranged from 0.05 to 0.1 ng/L, and the limits of quantification (LOQs) were less than 0.2 ng/L. A preliminary analysis of wastewater samples revealed that HHCB and AHTN were the two most commonly detected synthetic polycyclic musks; using a standard addition method, their concentration were determined to range from 1.2 to 37.3 ng/L with relative standard deviation (RSD) ranging from 2 to 6%. The results obtained using this approach are better than those from the conventional oil-bath HS-SPME.  相似文献   

17.
In the present article, a headspace solid-phase microextraction method coupled to GC/MS was developed and applied for the simultaneous determination of mono- and sesquiterpenic hydrocarbons in virgin olive oils of different olive variety and geographical origin. Analysis of various oils resulted in the simultaneous detection of 15 monoterpenes and 30 sesquiterpenes. Some of these hydrocarbons were previously reported to be constituents of virgin olive oil terpenoid fraction, although we also detected some terpenic hydrocarbons that have not previously been documented as present in virgin olive oil. Significant differences were detected in the proportion of terpenic compounds in oils obtained from different olive varieties grown in different geographical areas. The monoterpene, and particularly the sesquiterpene composition of olive oil may be used to distinguish samples from different cultivar and geographical areas.  相似文献   

18.
The gastronomic relevance and high price of white truffle are related mainly to its unique aroma. Here we evaluate, for the first time, the possibility of characterizing in a rapid and non-destructive way the aroma of white truffles based on proton transfer reaction mass spectrometry (PTR-MS). We indicate that anonymous PTR-MS fingerprinting allows sample classification and we also compare qualitatively and quantitatively PTR-MS data with measurements made by solid-phase microextraction gas chromatography (SPME-GC) of the same samples under the same conditions. PTR-MS fragmentation data of truffle-relevant compounds are also published here for the first time. Most of the sulfur-containing compounds detected by GC and relevant for white truffle aroma have a high positive correlation with single PTR-MS peaks. Our work indicates that, after preliminary comparison with GC data, PTR-MS is a new tool for the rapid, quantitative and non-invasive characterization of white truffle by direct headspace injection without any pre-concentration.  相似文献   

19.
A method using headspace solid-phase microextraction (HS-SPME) followed by gas chromatography/mass spectrometry (GC/MS) analysis has been developed to gain insight into the degradation of the chemical warfare agent sulfur mustard in solution. Specifically, the described approach simplifies the sample preparation for GC/MS analysis to provide a rapid determination of changes in sulfur mustard abundance. These results were found to be consistent with those obtained using liquid-liquid extraction (LLE) GC/MS. The utility of the described approach was further demonstrated by the investigation of the degradation process in a complex matrix with surfactant added to assist solvation of sulfur mustard. A more rapid reduction in sulfur mustard abundance was observed using the HS-SPME approach with surfactant present and was similar to results from LLE experiments. Significantly, this study demonstrates that HS-SPME can simplify the sample preparation for GC/MS analysis to monitor changes in sulfur mustard abundance in solution more rapidly, and with less solvent and reagent usage than LLE.  相似文献   

20.
Asarones (alpha-asarone and beta-asarone) are the active components in the traditional Chinese medicine (TCM) of Acorus tatarinowii Schott, which has been used to treat epilepsy for several thousand years. To perform the pharmacokinetics (PK) study of alpha- and beta-asarone from the TCM essential oil, a simple, rapid and sensitive method was developed for the determination of asarones from the TCM in rabbit plasma, based on headspace solid-phase microextraction (HS-SPME) followed by gas chromatography/mass spectrometry (GC/MS) with electron ionization (EI). The extraction parameters of headspace volume, fiber coating, sample temperature, extraction time, stirring rate and ion strength were systemically optimized. Furthermore, the method linearity, detection limit and precision were also investigated. It was shown that the proposed method provided a good linearity (0.02-20 microg/mL, R(2) > 0.99), low detection limit (<2.0 ng/mL) and good precision (RSD < 7.0%). Finally, HS-SPME followed by GC/MS was applied to fast determination of alpha- and beta-asarone in rabbit plasma at different time points after oral adminstration of the essential oil from A. tatarinowii. The experimental results suggest that the proposed method provides an alternative approach to the PK studies of volatile compounds in TCMs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号