Vial liquid-phase microextraction (LPME) combined with capillary electrophoresis (CE) was evaluated for the determination of the acidic drugs ibuprofen, naproxen, and ketoprofen present in water samples and in human urine. The 2.5 mL samples containing the drugs were filled into conventional vials and subsequently acidified by 250 microL of 1-10 M HCl. Porous hollow fibers of polypropylene containing 25 microL of an aqueous solution of 0.01-0.1 M NaOH (acceptor solution) and with dihexyl ether immobilized in the pores of the wall were placed into each of the samples. The acidic drugs were extracted from the acidified sample solutions into the dihexyl ether phase, in the pores of the hollow fiber, and further into the alkaline acceptor solution forced by high partition coefficients. The drugs were extracted almost quantitatively (75-100% extraction efficiency) from the 2.5 mL samples and into the 25 microL acceptor solutions, providing 75-100 times preconcentration. The acceptor solutions were collected for automated CE analysis, which enabled the drugs to be detected down to the 1 ng/mL level.  相似文献   

2.
A high-performance liquid chromatographic assay has been developed for the determination of a number of non-steroidal anti-inflammatory drugs in plasma. The samples were prepared by adding acetonitrile and perchloric acid to 200 microliter of plasma. Diclofenac, fenoprofen, ketoprofen, naproxen, phenylbutazone, piroxicam and sulindac were quantified in the supernatant produced using a mobile phase of phosphoric acid 0.03% (pH 2.5)-acetonitrile and a detecting wavelength of 254 nm. The reproducibility, linearity, precision and specificity of the assay were determined and found to be satisfactory. Alteration of the detection wavelength to 229 nm also permitted accurate determination of ibuprofen concentration in plasma. While reduction of the organic solvent content of the mobile phase and alteration of wavelength to 313 nm produced a system capable of quantifying salicylate and its metabolites in plasma and by further reducing the detecting wavelength to 237 nm, aspirin also was quantifiable. These methods have been applied in a cross-sectional study of medication compliance among rheumatoid arthritis patients treated with non-steroidal anti-inflammatory drugs.  相似文献   

3.
This study describes a method to determine nonsteroidal anti‐inflammatory drugs (NSAIDs) in urine samples based on the use of single‐drop microextraction (SDME) in a three‐phase design as a preconcentration technique coupled in‐line to capillary electrophoresis. Different parameters affecting the extraction efficiency of the SDME process were evaluated (e.g. type of extractant, volume of the microdroplet, and extraction time). The developed method was successfully applied to the analysis of human urine samples with LODs ranging between 1.0 and 2.5 μg/mL for all of the NSAIDs under study. This method shows RSD values ranging from 8.5 to 15.3% in interday analysis. The enrichment factors were calculated, resulting 27‐fold for ketoprofen, 14‐fold for diclofenac, 12‐fold for ibuprofen, and 44‐fold naproxen. Samples were analyzed applying the SDME–CE method and the obtained results presented satisfactory recovery values (82–115%). The overall method can be considered a promising approach for the analysis of NSAIDs in urine samples after minimal sample pretreatment.  相似文献   

4.
An analytical method based on LC and UV detection has been developed for the determination of anti-inflammatory compounds and estrogens in water samples. The drugs investigated were diclofenac, ketoprofen, ibuprofen, naproxen, clofibric acid, estriol, 17beta-estradiol, estrone and ethynylestradiol. The detection limits were in the range of 6-74 microg/L and 0.041 -0.16 mg/L for acidic pharmaceuticals and estrogens, respectively, using narrow-bore C18 analytical column. Analyte enrichment from water samples was achieved by SPE procedure using polymeric Strata-X cartridges. Average recoveries obtained from 2.5 L of surface water sample were in the range of 77-98%.  相似文献   

5.
An open tubular wall-coated capillary column containing histidine functional groups was prepared and employed for the capillary electrochromatographic separation of non-steroidal anti-inflammatory drugs. The anion exchange along with the hydrogen bonding and hydrophobic properties of the surface coating allowed the separation of analytes with very similar ionic mobility. Selectivity and resolution were studied by changing the pH over the range from 3.5 to 5.0 and the concentration of the buffer from 10 to 25 mM, as well as variation of the organic modifier, such as methanol, ethanol and 1-propanol over the range 7.5 to 20%. The optimum experimental conditions for the separation of a drug mixture, which consisted of indoprofen, ketoprofen, suprofen, naproxen, flurbiprofen, fenoprofen and ibuprofen were using a mixture of acetate buffer (20 mM, pH 5.0)-ethanol (1:5, v/v) as background electrolyte and an applied voltage of -20 kV with UV detection at 220 nm. The separation of these drugs could be achieved with an average plate number of 1.0 x 10(5) m(-1).  相似文献   

6.
A sulfated beta-cyclodextrin (sulfated beta-CD)-mediated capillary electrophoresis method is described for the enantioseparation of cetirizine using achiral cefazolin as an internal standard. The enantioseparation of the drug was performed in a borate buffer (5 mM, pH 8.7) with 1% sulfated beta-CD (w/v) as chiral selector at 10 kV. Several parameters affecting the separation were studied, including the pH and the concentration of borate buffer and chiral selector. Under optimized conditions, a baseline separation of two enantiomers was achieved in less than 7 min. Using cefazolin as an internal standard (IS), the linear range of the method for the determination of levocetirizine was over 1.0 to 50.0 microg/mL; the detection limit (signal-to-noise ratio = 3) of levocetirizine was 0.5 microg/mL. The method allowed the enantioseparation of cetirizine in bulk samples and enantiomeric purity evaluation of levocetirizine (R-enantiomer) in pharmaceutical tablets (Xyzal), and it was also found to be suitable for enantioseparation in human plasma.  相似文献   

7.
A new micelle capillary electrophoresis based on cyclodextrin micellar electrokinetic chromatography (MEKC) for the determination of bisphenol A and 10 alkylphenols in rat serum is reported. Several surfactants and dextrins were studied. Bisphenol A and alkylphenols were separated using a 50 microm x 50 cm capillary with 20 mM borate phosphate buffer (pH 8.0) containing 20 mM sodium dodecylsulfate and 5 mM gamma-cyclodextrin as carrier. The method could determine 0.6-2000 microg/mL of phenols in 100 microL serum by photometric detection at 214 nm. Using 2.0 mL serum, 1.0 ng/mL of phenols could be determined. The relative standards deviations were 6.3-7.7% at 10 microg/mL in serum. The recoveries were 91.8-93.0% with 10 microg/mL serum samples.  相似文献   

8.
We developed capillary electrophoresis with a chemiluminescence detector using a polymer solution as the separation medium for the analysis of biopolymers, such as DNA and protein. A peroxyoxalate chemiluminescence reagent of bis(2,4,6-trichlorophenyl)oxalate was used together with fluorescein-labeling reagent. When a migration buffer solution containing carboxylmethylcellulose was used, the flow-type chemiluminescence detection cell was found to give a better resolution than the batch-type one. Fluorescein-labeled adenosine triphosphate of 1.0 x 10(-4) M was examined by means of capillary electrophoresis with absorption (260 nm), fluorescence (ex. 496 nm and em. 517 nm), and chemiluminescence detectors. The chemiluminescence detection showed the highest sensitivity among them; the S/N ratios obtained by absorption, fluorescence, and chemiluminescence detections were 4, 38, and 130, respectively. Fluorescein-labeled DNA was prepared through a polymerase chain reaction using fluorescein-labeled deoxyadenosine triphosphate. A mixture of the labeled DNA fragments (500, 600, 700, 800, 900, and 993 bp) was successfully separated and detected by the present system. A mixture of proteins (lysozyme, cytochrome C, and ribonuclease A) which were labeled with fluorescein isothiocyanate was also separated and detected.  相似文献   

9.
A suite of 12 widely used pharmaceuticals (ibuprofen, diclofenac, naproxen, bezafibrate, gemfibrozil, ofloxacin, norfloxacin, carbamazepine, primidone, sulphamethazine, sulphadimethoxine and sulphamethoxazole) commonly found in environmental waters were separated by highly sulphated CD-modified MEKC (CD-MEKC) with UV detection. An experimental design method, face-centred composite design, was employed to minimize run time without sacrificing resolution. Using an optimized BGE composed of 10 mM ammonium hydrogen phosphate, pH 11.5, 69 mM SDS, 6 mg/mL sulphated beta-CD and 8.5% v/v isopropanol, a separation voltage of 30 kV and a 48.5 cm x 50 microm id bare silica capillary at 30 degrees C allowed baseline separation of the 12 analytes in a total analysis time of 6.7 min. Instrument LODs in the low milligram per litre range were obtained, and when combined with offline preconcentration by SPE, LODs were between 4 and 30 microg/L.  相似文献   

10.
A vesicle-forming chiral cationic surfactant (1R,2S)-(-)-N-dodecyl-N-methyl-ephedrinium bromide was evaluated as a pseudo-stationary phase in micellar electrokinetic chromatography (MEKC) for enantioseparation of eight non-steroidal anti-inflammatory drugs e.g., carprofen, flurbiprofen, fenoprofen, ibuprofen, indoprofen, ketoprofen, naproxen and suprofen by capillary electrophoresis. The effects of varying experimental conditions such as pH and concentration of surfactant in the running buffer on the enantiomer separation of the drugs are reported. A mixture of five of the above drugs was separated and each enantiomeric pair was also separated simultaneously in a single run by use of the surfactant. The strong electrostatic interactions between the analytes and the vesicles seemed to have a major role in the enantiomeric separation of the profens.  相似文献   

11.
A method using capillary zone electrophoresis was developed for the simultaneous separation of 14 antiarrhythmic drugs belonging to various classes. The drugs are separated on a fused-silica capillary, 90 cm x 75 microm (72 cm effective length), with phosphate and acetate buffers as background electrolytes and UV detection at 217 nm. The effects of buffer pH, temperature, and applied voltage on the migration of the drugs were studied. The pH was found to be the most significant factor determining effective separation. The antiarrhythmic compounds are completely separated within a relatively short time (< 7 min) by using 70 mM phosphate buffer at pH 7.91, an applied voltage of 28 kV, and a temperature of 32 degrees C. Mexiletine (MEX) and flecainide (FLE) were quantified under conditions of the optimum separation. The calibration graphs were constructed over the concentration range of 4.0-14.0 microg/mL for both drugs with good correlation (r > or = 0.9999). Detection and quantitation limits were found to be 0.5 and 1.5 microg/mL for FLE and 0.7 and 2.1 microg/mL for MEX, respectively. The proposed method was used for the determination of both drugs in their commercial forms with satisfactory precision (relative standard deviations of 0.36-1.21% for FLE and 0.78-1.66% for MEX) and accuracy (relative standard errors of 0.13-1.17% for FLE and 0.35-1.18% for MEX).  相似文献   

12.
Non-steroidal anti-inflammatory drugs (NSAIDs) are among the most common groups of pharmaceuticals detected in environmental matrices. Although several derivatization procedures have been employed in the gas chromatographic analysis of NSAIDs, the application of trimethylsilyldiazomethane has never yet been reported. This work has studied the derivatization of widely used NSAIDs (ibuprofen, ketoprofen and naproxen) by trimethylsilyldiazomethane. Special emphasis was placed on the influence of temperature and reaction time on the reaction yield, and on the determination of the instrumental detection limit. The results are compared with those obtained by methylation using boron trifluoride methanol solution, and by silylation with a mixture of N,O-bis(trimethylsilyl)trifluoroacetamide and trimethylchlorosilane (99:1, v/v) and with N-methyl-N-[tert-butyldimethylsilyl]trifluoroacetamide. The derivatization of ibuprofen, ketoprofen and naproxen by trimethylsilyldiazomethane was shown to be simple, fast, efficient, and suitable for trace analysis (the respective instrumental detection limits for ibuprofen naproxen, and ketoprofen were 2, 4, and 4 ng). Trimethylsilyldiazomethane can be used as an alternative reagent for determining acidic drugs in environmental matrices.  相似文献   

13.
This paper reports the development of a rapid method for the enantioselective analysis of the nonsteroidal anti-inflammatory drug ibuprofen in human plasma by capillary electrophoresis employing the anionic cyclodextrin-modified electrokinetic chromatography mode. Sample cleanup was carried out by acidification with HCl followed by liquid-liquid extraction with hexane:isopropanol (99:1 v/v). The complete enantioselective analysis was performed within 10 min, using 100 mmol L(-1) phosphoric acid/triethanolamine buffer, pH 2.6, containing 2.0% w/v sulfated beta-cyclodextrin as chiral selector; fenoprofen, another nonsteroidal anti-inflammatory drug, was used as internal standard. The calibration curves were linear over the concentration range of 0.25-125.0 microg mL(-1) for each enantiomer of ibuprofen. The mean recoveries for ibuprofen enantiomers were up to 85%. The enantiomers studied could be quantified at three different concentrations (0.5, 5.0 and 50.0 microg mL(-1)) with a coefficient of variation and relative error not higher than 15%. The quantitation limit was 0.2 microg mL(-1) for (+)-(S)- and (-)-(R)-ibuprofen using 1 mL of human plasma. The plasma endogenous compounds and other drugs did not interfere with the present assay. The analysis of real plasma samples obtained from a healthy volunteer after administration of 600 mg of racemic ibuprofen showed a maximum plasma level of 29.6 and 39.9 microg mL(-1) of (-)-(R)- and (+)-(S)-ibuprofen, respectively, and the area under plasma concentration-time curve AUC(0-infinity) (+)-(S)/AUC(0-infinity) (-)-(R) ratio was 1.87.  相似文献   

14.
Lu X  Luo Z  Liu C  Zhao S 《Journal of separation science》2008,31(16-17):2988-2993
An HPLC-resonance Rayleigh scattering (RRS) (HPLC-RRS) detection system is described for separation and detection of proteins. This system is based on the modification of a commercial HPLC instrument involving the addition of a pump and a T-shaped interface, and a common fluorescence detector was used for detection. The detection principle is based on the change of RRS intensity of the ion-association complex formed from biebrich scarlet (BS) and protein. The RRS signal was detected at lambdaex=lambdaem=376 nm. The utility of the presented method was demonstrated by the separation and determination of four proteins involving cytochrome (Cyt-c), lysozyme (Lys), HSA, and gamma-globulin (gamma-Glo). An LOD of 0.2-1.0 microg/mL was reached and a linear range was found between peak area and concentration in the range of 0.20-3.0 microg/mL for Cyt-c, 0.25-2.5 microg/mL for Lys, 1.5-10 microg/mL for HSA, and 2.0-15 microg/mL for gamma-Glo, with linear regression coefficients all above 0.99. The method presented has been applied to determine HSA and gamma-Glo in human serum samples synchronously.  相似文献   

15.
Profens, including pranoprofen, fenoprofen, flurbiprofen, ketoprofen and ibuprofen (Ib), were derivatized by a water-soluble benzofurazan fluorescent reagent, 4-N-(4-N'-aminoethyl)piperazino-7-nitro-2,1,3-benzoxadiazole and then were run on capillary electrophoresis in a NH4Ac-HAc buffer of pH 3.1 containing 2.4 mM beta-cyclodextrin. At room temperature, the derivatization reaction was catalyzed by triphenyl phosphine and diphenyl disulfide in acetonitrile medium, and the derivatives fluoresce around 530 nm when excited at 488 nm. With the CE running on a 50 cm x 50 microm I.D. length fused-silica capillary of by using Ar+ laser induced-fluorescence detection, the detection limits attained were in the range of 0.16 to 0.3 fmol.  相似文献   

16.
Isotachophoresis (ITP) was applied for the determination of some antirheumatic drugs (fenoprofen, naproxen, ibuprofen, and ketoprofen) in human serum. The leading electrolyte contained hydrochloric acid (10 mmol x L(-1)), creatinine (pH 4.5) and methylhydroxyethyl cellulose (0.1%). The terminating electrolyte was 2-(N-morpholino)ethanesulfonic acid (10 mmol x L(-1)) adjusted with tris(hydroxymethyl)aminomethane to pH 6.9. The ITP separations were carried out in column-coupling configuration of the separation unit provided with a preseparation column of 160 x 0.8 mm inner diameter (ID) and analytical column of 160 x 0.3 mm ID. The limit of detection for ibuprofen, fenoprofen, and naproxen in serum by direct sampling was 0.008, 0.005 and 0.004 mmol x L(-1). The limit of detection for ketoprofen in serum after ethanol precipitation was 0.001 mmol x L(-1).  相似文献   

17.
Dispersive liquid–liquid microextraction (DLLME) coupled with liquid chromatography-tandem mass spectrometry detection was applied for determination of selected anti-inflammatory pharmaceuticals: ibuprofen, ketoprofen, naproxen and diclofenac. Development of DLLME procedure included optimisation of several important parameters such as kind and volume of extracting and dispersive solvents as well as sample pH. Under optimised conditions a two-step extraction with sonication was used. Chloroform was applied as the extracting and acetone as dispersing solvent. Calibration curves ranges were 1–500 μg L?1 for naproxen and ibuprofen and 0.25–500 μg L?1 for ketoprofen and diclofenac with correlation coefficients at least 0.997. Limits of quantitation were from 0.5 to 10 ng L?1. The developed analytical method was employed for determination of ibubrofen, ketoprofen, naproxen and diclofenac in river and tap water samples. The results showed that DLLME is a simple, rapid and sensitive analytical technique for the pre-concentration of trace amounts of pharmaceuticals in environmental water samples.  相似文献   

18.
A new fabrication procedure for integration of ultraviolet transparent pure-silica planar waveguides, fiber couplers and high-aspect ratio submicrometer channels is presented. Only a single photolithographic mask step is required. The channels are 80-90 microm deep and the width can be reduced to about 0.5 microm, corresponding to a height-to-width ratio of more than 150. The core of the waveguides consists of pure silicon dioxide, which is favorable over doped silica, due to the absence of absorption centers associated with the dopants. This furthermore improves the long-term stability of the waveguides, because of an increased radiation resistance of the glass. The propagation loss decreases from 1.0 dB/cm at 200 nm to 0.2 dB/cm at 800 nm, which, to our knowledge, is the lowest propagation loss reported for integrated planar waveguides in the ultraviolet wavelength region to date. The effective optical path length is 1.2 mm for an absorbance cell with a nominal length of 1.0 mm, indicating effective suppression of stray light. The limit of detection for paracetamol when present in the entire channel network was determined to 3 microg/mL. Finally, the applicability of the fabricated devices for capillary electrophoresis was evaluated by separation of caffein, paracetamol and ketoprofone using absorbance detection at 254 nm.  相似文献   

19.
A method is described for the derivatization of several non-steroidal anti-inflammatory arylalkanoic acids (ibuprofen, ketoprofen, naproxen, fenoprofen, flurbiprofen, pirprofen, cicloprofen, tiaprofenic acid, etodolic acid) with optically active amphetamine. The usefulness of this reagent compared to alpha-methylbenzylamine is described. The enantiomers are separated as diastereoisomers using capillary gas chromatography with nitrogen-phosphorus detection. The procedure is readily applied to the quantification of the enantiomers in urine and plasma samples.  相似文献   

20.
A new, automatic method for the clean-up, preconcentration, separation, and quantitation of nonsteroidal anti-inflammatory drugs (NSAIDs) in biological samples (human urine and serum) using solid-phase extraction coupled on-line to capillary electrophoresis is proposed. Automatic pretreatment is carried out by using a continuous flow system operating simultaneously with the capillary electrophoresis equipment, to which it is linked via a laboratory-made mechanical arm. This integrated system is controlled by an electronic interface governed via a program developed in GWBasic. Capillary electrophoresis is conducted by using a separation buffer consisting of 20 mM NaHPO4, 20 mM beta-cyclodextrin and 50 mM SDS at pH 9.0, an applied potential of 20 kV and a temperature of 20 degrees C. The analysis time is 10 min and the detection limits were between 0.88 and 1.71 microg mL(-1). Automatic clean-up and preconcentration is accomplished by using a C-18 minicolumn and 75% methanol as eluent. The limit of detection of NSAIDs can be up to 400-fold improved when using sample clean-up. The extraction efficiency for these compounds is between 71.1 and 109.7 microg mL(-1) (RSD 2.0-7.7%) for urine samples and from 77.2 to 107.1 microg mL(-1) (RSD 3.5-7.1%) for serum samples.  相似文献   