首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Use of optimized instrument parameters that result from statistical experimentation revealed that the sensitivity of atmospheric pressure chemical ionization (APCI) liquid chromatography-mass spectrometry (LC/MS) is greater than the sensitivity of an optimized Thermabeam? LC/MS interface by about 3 orders of magnitude, when tested on aromatic compounds. APCI is one of the few LC/MS techniques in which the chromatogram is directly comparable with liquid chromatographs that use ultraviolet detection. The optimum instrument parameters for a Finnigan SSQ-7000 APCI LC/MS interface were found at low flow rates (e. g., 0. 1 mL/min), relatively low capillary heat (e. g., 225 °C), and high sheath-gas pressure (e. g., 60 lb/in2). The optimization was achieved by monitoring the responses of sensitivity, fragmentation, and cluster ion formation. The fine tuning for high sensitivity calls for a high percentage of water in the mobile phase. In contrast, a high percentage of organic content in the mobile phase is required to obtain abundant protonated molecular ions with respect to fragmentation and clustering. This is an important consideration for analyses of unknowns.  相似文献   

3.
A novel spray-ionization technique for nanoflow liquid chromatography/mass spectrometry (nLC/MS) has been developed by modifying the sonic spray ionization (SSI) technique. A solution from a tapered fused-silica capillary is sprayed by a gas flow coaxial to the capillary, and ions produced are analyzed with an ion-trap mass spectrometer. The ion intensity is shown to have a steep threshold at a low gas velocity and to be much less dependent on the gas velocity than that of conventional SSI, in which the ion intensity is strongly dependent on the gas velocity and reaches its maximum at sonic velocity. Thus, we conclude that the concentration of charge in the solution at the tapered capillary tip with an inner diameter of 15 microm is almost at saturation so that charged droplets are produced from the solution by electrical force, rather than by sheer stress due to the gas flow. The ions are readily produced from these charged droplets. Preliminary results are compared with results obtained with a miniaturized electrospray unit.  相似文献   

4.
The number and type of atmospheric pressure techniques suitable for sampling analytes from surfaces, forming ions from these analytes, and subsequently transporting these ions into vacuum for interrogation by MS have rapidly expanded over the last several years. Moreover, the literature in this area is complicated by an explosion in acronyms for these techniques, many of which provide no information relating to the chemical or physical processes involved. In this tutorial article, we sort this vast array of techniques into relatively few categories on the basis of the approaches used for surface sampling and ionization. For each technique, we explain, as best known, many of the underlying principles of operation, describe representative applications, and in some cases, discuss needed research or advancements and attempt to forecast their future analytical utility. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

5.
A previously uncharacterized source of detection mass bias is shown to be associated with atmospheric pressure ionization mass spectrometry (APIMS), and is attributed to a mass dependence in the sampling of ions from the supersonic free jet expansion of gas emerging from the ion source. The halide ions Cl ?, Br?, and I? are shown to be transported from the ion source aperture to a quadrupole mass filter with efficiencies that increase linearly with increasing mass of the ion. While the polyatomic anions SF 6 - and C7F 14 - are detected with even greater efficiencies than would be expected for monatomic anions of the same mass, this additional sensitivity to the polyatomic anions is thought to be related to ion loss processes occurring within the ion source. The experimental conditions under which these mass bias effects can be minimized or enhanced in APIMS are described.  相似文献   

6.
This technical note describes in detail the fabrication, operation and characterization of a pneumatically driven dopant introduction device, with a solvent reservoir capacity of 300 mL. Dopant flow rates and stability for this device are governed by the simple regulation of gas pressure rather than the progression of a stepper motor and syringe diameter, as is the case for typical infusion pumps. The device has the potential to provide days or even weeks of continuous, uninterrupted dopant flow at rates commonly adopted for atmospheric pressure photoionization (APPI) experiments without the need to replenish the dopant supply. Although not a refined instrumental design, this device was developed as an alternative cost-effective means of introducing stable dopant flow to an APPI source. The device was designed such that all components would be commercially available and easily procurable from common scientific part vendors. Figures and suggested part numbers are provided to allow those interested to fabricate similar devices to suit their individual experimental needs. Device characterization was performed while monitoring such factors as flow rate calibration, overall flow stability and reproducibility. In addition, a standard mixture of three polycyclic aromatic hydrocarbons was employed as a model sample for a typical reversed-phase liquid chromatography/atmospheric pressure photoionization mass spectrometry (LC/APPI-MS) application in order to demonstrate device performance.  相似文献   

7.
A new continuous chromatographic process (VARICOL) has been presented recently. The basic principle of the new VARICOL process consists of an asynchronous shift of the inlet/outlet lines in a multi-column system on a recycle loop. This process has been used to perform the separation of the optical isomers of the SB-553261 racemate. In this paper, we illustrate that for this specific separation, the VARICOL process is more efficient than the well-known SMB process.  相似文献   

8.
Super‐atmospheric pressure chemical ionization (APCI) mass spectrometry was performed using a commercial mass spectrometer by pressurizing the ion source with compressed air up to 7 atm. Similar to typical APCI source, reactant ions in the experiment were generated with corona discharge using a needle electrode. Although a higher needle potential was necessary to initiate the corona discharge, discharge current and detected ion signal were stable at all tested pressures. A Roots booster pump with variable pumping speed was installed between the evacuation port of the mass spectrometer and the original rough pumps to maintain a same pressure in the first pumping stage of the mass spectrometer regardless of ion source pressure. Measurement of gaseous methamphetamine and research department explosive showed an increase in ion intensity with the ion source pressure until an optimum pressure at around 4–5 atm. Beyond 5 atm, the ion intensity decreased with further increase of pressure, likely due to greater ion losses inside the ion transport capillary. For benzene, it was found that besides molecular ion and protonated species, ion due to [M + 2H]+ which was not so common in APCI, was also observed with high ion abundance under super‐atmospheric pressure condition. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
A method using liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (LC/APCI-MS) has been developed for the characterization and determination of pyridoquinoline derivatives 4,6-bis(dimethylaminoethylamino)-2,8,10-trimethylpyrido[3,2-g]quinoline, 4,6-bis(dimethylaminoethoxy)-2,8,10-trimethylpyrido[3,2-g]quinoline and 4,6-bis[(dimethylaminoethyl)thio]-2,8,10-trimethylpyrido[3,2-g] quinoline, all with potential antitumor properties. LC separation was performed on a conventional C18 column using a binary mobile phase composed of acetonitrile and 50 mM aqueous ammonium formate at pH 3. The APCI mass spectra obtained showed that proton addition giving [M + H]+ was the common mode of ionization to the amino- and thiopyridoquinolines, whereas the alkoxypyridoquinoline was identified by the main formation of the [M - (C2H3)N(CH3)2 + H]+, followed by the [M + H]+ ion. The LC separation conditions and MS detection parameters were optimized for the determination. The analytical method was also applied to the determination of these pyridoquinoline derivatives in fetal calf serum using liquid-liquid extraction with dichloromethane. Acceptable recovery values were obtained, ranging between 45 and 98%.  相似文献   

10.
High-performance liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (HPLC/APCI-MS) is a very promising approach to structural investigations of positional isomers and stereoisomers. This method was applied successfully to stereoisomeric norditerpenoid alkaloids differing in configuration at C-6. APCI-MS allowed the easy and precise control of energy deposition by varying the drift voltage. Comparison of the breakdown curves, observed by changing the potential difference between the first electrode and the second electrode of the APCI ion source, revealed the stereochemical dependence of different fragmentations. Comparison of the APCI spectra showed that the abundance of fragment ions was significantly higher for C-6beta alkaloid than for C-6alpha alkaloid. The axial positions of the corresponding substituents (6-methoxyl and 8-hydroxyl) strongly suggested a 1,3-diaxial interaction effect of the fragmentation. The characteristic fragment ions were formed by the loss of water or acetic acid at position 8, irrespective of the stereochemistry at position 6. The possibility of distinct fragmentation mechanisms depending on the stereochemistry of the precursor ion could be discerned by recording the spectra in a deuterated solvent system of 0.05 M ammonium acetate in D2O-acetonitrile-tetrahydrofuran. Loss of D2O from the precursor ion gave the fragment ion. This result indicated that the proton of protonation was included in the leaving water molecule. The peak intensity ratio R = [M+H]+/[M+H-H2O]+ manifested the stereochemical differentiation of alkaloids at position 6.  相似文献   

11.
Atmospheric pressure ionization (API) techniques are evaluated for the mass spectral analysis of N-methyl carbamate pesticides. Atmospheric pressure chemical ionization (APCI) using a heated nebulizer interface provided both protonated molecules and abundant, characteristic fragment ions. With ion spray (ISP; pneumatically assisted electrospray ionization), which utilizes a milder “ion evaporation” process, primarily protonated molecules were obtained, although fragment ions similar to those observed in APCI could be induced by variation of the API orifice voltage. Product ion spectra of ISP-derived protonated molecules, generated by tandem mass spectrometry using collision-induced dissociation, are also presented. The APCI and ISP spectra of the carbamates are compared to those obtained with a thermospray interface and also to their electron ionization and methane CI spectra obtained with a particle beam interface. For all four interfaces, combined liquid chromatography mass spectrometry methods using conventional (4.6 mm i.d.) columns are described for the separation and detection of pesticide mixtures. These methods are applied to the confirmatory analysis of three representative carbamate pesticides, spiked at the 0.1-ppm level in green peppers. For those carbamates amenable to gas chromatography mass spectrometry, comparative results are presented.  相似文献   

12.
大气压离子化技术/飞行时间质谱联用进展   总被引:1,自引:0,他引:1  
综述了大气压离子化技术/飞行时间质谱联用技术及其应用的进展  相似文献   

13.
14.
A novel approach to the analysis of ecstasy tablets by direct mass spectrometry coupled with thermal desorption (TD) and counter‐flow introduction atmospheric pressure chemical ionization (CFI‐APCI) is described. Analytes were thermally desorbed with a metal block heater and introduced to a CFI‐APCI source with ambient air by a diaphragm pump. Water in the air was sufficient to act as the reactive reagent responsible for the generation of ions in the positive corona discharge. TD‐CFI‐APCI required neither a nebulizing gas nor solvent flow and the accompanying laborious optimizations. Ions generated were sent in the direction opposite to the air flow by an electric field and introduced into an ion trap mass spectrometer. The major ions corresponding to the protonated molecules ([M + H]+) were observed with several fragment ions in full scan mass spectrometry (MS) mode. Collision‐induced dissociation of protonated molecules gave characteristic product‐ion mass spectra and provided identification of the analytes within 5 s. The method required neither sample pretreatment nor a chromatographic separation step. The effectiveness of the combination of TD and CFI‐APCI was demonstrated by application to the direct mass spectrometric analysis of ecstasy tablets and legal pharmaceutical products. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

15.
16.
17.
Daniel JM  Ehala S  Friess SD  Zenobi R 《The Analyst》2004,129(7):574-578
A new technique is presented for the coupling of atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) mass spectrometry with liquid delivery systems. Mass measurements of polymers and peptides are demonstrated using a co-dissolved matrix, e.g. alpha-cyano-4-hydroxycinnamic acid (HCCA). Improvements in terms of sensitivity are achieved by optimizing the shape und control of the exit capillary and by using a laser (355 nm) at a 1 kHz repetition rate. Two calibration experiments promise a good applicability of the presented coupling method for quantitative measurements. The limit of detection achieved so far is 500 nM for peptides in methanol solution containing 25 mM HCCA.  相似文献   

18.
An analytical method is presented for the determination of chlorantraniliprole residues in crops. Chlorantraniliprole residues were extracted from crop matrixes with acetonitrile after a water soak. The extracts were passed through a strong anion-exchange (SAX) SPE cartridge stacked on top of a reversed-phase (RP) polymer cartridge. After both cartridges were rinsed and vacuum-dried, the SAX cartridge was removed, and chlorantraniliprole was eluted from the RP polymer cartridge with acetonitrile. The acetonitrile eluate was evaporated to dryness, reconstituted, and analyzed using an LC/MS/MS instrument equipped with an atmospheric pressure chemical ionization source. The method was successfully validated at 0.010, 0.10, and 10 mg/kg for the following crop matrixes: potatoes, sugar beets (tops), lettuce, broccoli, soybeans, soybean forage, tomatoes, cucumbers, oranges, apples, pears, peaches, almonds (nutmeat), rice grain, wheat grain, wheat hay, corn stover, alfalfa forage, cottonseed, grapes, and corn grain. The average recoveries from all crop samples fortified at the method LOQ ranged from 91 to 108%, with an overall average recovery of 97%. The average recoveries from all crop samples fortified at 10 times the method LOQ ranged from 89 to 115%, with an overall average recovery of 101%. For all of the fortified control samples analyzed in this study, the overall average recovery was 99%.  相似文献   

19.
The use of high-performance liquid chromatography combined with chloride-enhanced atmospheric pressure chemical ionization for the determination of polychlorinated n-alkanes (PCAs, also called chlorinated paraffins or CPs) is described as an alternative to gas chromatographic methods. Atmospheric pressure chemical ionization in the negative ion mode formed exclusively [M+Cl](-) adduct ions and suppressed fragmentation when a chlorinated solvent was added. Limits of detection were 1-2 ng/microL for technical PCA mixtures. Response factors for single short-chain PCA homologues with different degrees of chlorination varied by not more than a factor of 6.5. The developed method was applied for the determination of the composition of technical PCA mixtures as well as for the analysis of PCAs in household commodities. Medium-chain PCAs were found in paint samples at concentrations of 8.2-11.5% (w/w), compared with 7.4-11.5% obtained by gas chromatography combined with electron ionization tandem mass spectrometry.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号