首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
A liquid chromatography/tandem mass spectrometry (LC/MS/MS) method is described for the extraction, cleanup, determination, and confirmation of chloramphenicol (CAP) in cooked crab meat. The method involves pulverization of cooked crab meat with dry ice; extraction of the CAP into ethyl acetate (EtOAc); evaporation (by N2) of the EtOAc; addition of methanol, aqueous NaCl, and heptane; extraction of the lipids into the heptane, followed by extraction of the aqueous phase with EtOAc; evaporation (by N2) of the EtOAc; dissolution into methanol-water; filtration; and separation/detection/confirmation using LC/MS/MS. Crab meat was fortified at 0.25, 0.50, and 1.0 ng/g (ppb) chloramphenicol. Average absolute recoveries were 67, 84, and 86%, respectively, with relative standard deviation values all less than 1%. Four daughter ions (m/z 152, 176, 194, and 257) were monitored off the m/z 321 precursor ion. Determination was based on a standard curve using the peak areas of the m/z 152 daughter ion (the base peak) for standard solutions equivalent to 0.10, 0.20, 0.50, and 1.0 ppb in tissue (made with control crab extract). A set of 6 matrix controls (unfortified crab meat) was also analyzed, in which no chloramphenicol was detected. For identification purposes, the ion ratios (of each daughter ion versus the base daughter ion) of the fortified crab versus those of the chloramphenicol standards agreed within 10% (relative) at fortified chloramphenicol concentrations of 0.25-1.0 ppb.  相似文献   

3.
Liquid chromatography/atmospheric pressure photoionization tandem mass spectrometry (LC/APPI-MS/MS) was investigated as an instrumental method for the analysis of the halogenated norbornene flame retardants, Mirex, Dechloranes 602, 603, 604, and Dechlorane Plus (DP). The LC separation was optimized by screening a variety of stationary and mobile phases, resulting in a short LC separation time of 5 min. Different atmospheric pressure ionization approaches were examined including electrospray ionization, atmospheric pressure chemical ionization, and APPI, each with and without post-column addition. APPI without post-column addition was chosen for providing the best ionization response. The optimized LC/APPI-MS/MS approach resulted in instrument detection limits ranging between 25 and 50 pg. Good linearity was also achieved (up to 25.0 ng/μL; R >0.999). The method was applied to extracts of environmental samples including surface water, fish and sediments for screening purposes, and the results agreed well with those obtained by gas chromatography/mass spectrometry.  相似文献   

4.
An efficient, high throughput and cost-effective direct aqueous injection approach for the analysis of neonicotinoid pesticides and a common metabolite in environmental water has been described here. The method determines eight neonicotinoid pesticides (acetamiprid, clothianidin, dinotefuran, flonicamid, imidacloprid, nitenpyram, thiacloprid, thiamethoxam) and 6-chloronicotinic acid (a common metabolite of the first generation neonicotinoids, acetamiprid, imidacloprid, nitenpyram and thiacloprid) without any sample enrichment/cleanup steps. The method detection limits are 2–8 ng/L for the neonicotinoids and 93 ng/L for 6-chloronicotinic acid. The performance of the QTRAP®5500 mass spectrometer was compared against a 4000QTRAP®, and a QTRAP®6500, to provide insights for future method transfer among different generations of instrumentations. Critical mass spectrometric parameters such as collision energy were quite consistent among the three instruments evaluated. However, increased chemical background levels for some target compounds on the more sensitive instruments were observed. The application of differential ion mobility spectrometry combined with tandem mass spectrometry was demonstrated to have great potential in reducing chemical background and/or isobaric interferences inherited in sample matrices. This ISO 17025 accredited method was employed to quantitate neonicotinoids in Ontario stream water samples. Good correlation for analytical results of this direct aqueous injection approach and a previously published solid phase extraction approach warrant high confidence in data quality.  相似文献   

5.
Liquid chromatography with atmospheric pressure chemical ionisation mass spectrometry (LC/APCI-MS), using negative ion detection in a triple quadrupole instrument, was used for the determination of chlorophenols (CPs) in environmental samples. In-source collision-induced dissociation (CID) was compared with MS/MS fragmentation. In general, less fragmentation was observed in MS/MS as compared with in-source CID, with the latter providing more intense fragment ions due to chemical ionisation. Under MS/MS conditions [M - H - HCl](-) was the main fragment ion observed for all compounds except for pentachlorophenol, which showed no fragmentation. For multiple reaction monitoring (MRM) acquisition mode, the transition from [M - H](-) to [M - H - HCl](-) was selected, leading to detection limits down to 0.3 ng injected. Direct and headspace-solid-phase microextraction (HS-SPME) were used as preconcentration procedures for the analysis of CPs in wood and in industrially contaminated soils. CPs were quantified by standard addition, which led to good reproducibility (RSD between 4 and 11%) in both SIM and MRM modes, and detection limits down to ng/g. The combination of MS/MS and in-source CID allowed confirmation of the presence of CPs in environmental samples.  相似文献   

6.
An improved and simplified analytical method which offers rapid, accurate determination and identification of phenolic compounds in honey samples is reported. The honey samples were diluted by acidified water (pH 2), and analyzed by HPLC–ESI-MS/MS. Simultaneously determination of phenolic acids and flavonoids was carried out by a liquid chromatography–mass spectrometry. Comparison between atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) was performed by analysis of standards. Fragmentation of analytes for subsequent selective Multiple Reaction Monitoring (MRM) analysis was investigated in negative mode. Sample preparation without separation of sugars and clean-up procedure, followed by fast chromatographic separation using a narrow-bore column C18 (50 mm × 2.1 mm, 3 μm) allowed the analysis to be completed in a short run time. LODs were ranged between 1 and 15 ng L−1 for p-coumaric acid and naringenin, respectively. The method was applied for determination of phenolic acids and flavonoids in honey samples from different botanical origin.  相似文献   

7.
Ginkgo biloba (ginkgo) is one of most frequently used botanical dietary supplements. The bioactive constituents include the terpenoid lactones consisting of bilobalide and the ginkgolides A, B, C and J. A new assay based on high-performance liquid chromatography/electrospray tandem mass spectrometry (LC/MS/MS) was developed for the measurement of the terpenoid lactones in ginkgo products such as leaf powder and extracts. Initially, the MS/MS fragmentation pathways of ginkgolides were investigated to identify abundant fragment ions that might be useful for the sensitive and selective detection of ginkgolides and bilobalide during LC/MS/MS. Then, sample preparation and clean-up procedures were streamlined to maximize throughput by taking advantage of the selectivity of LC/MS/MS detection. Analyte recoveries exceeded 90%, the intra-assay and inter-assay relative standard deviations were <5%, the relative error was <8% and the limits of detection and quantification were 3.6-120 and 11-350 fmol, depending on the analyte that was injected on to the LC column. Therefore, this LC/MS/MS assay facilitated the rapid quantitative analysis of ginkgolides A, B, C and J and bilobalide in ginkgo dietary supplements with excellent recovery, reproducibity, accuracy and sensitivity.  相似文献   

8.
9.
A liquid chromatography/tandem triple-quadrupole mass spectrometry assay to quantify paclitaxel in rat tissue homogenates containing taxol or paclitaxel nanoliposome (PTX-NLP) was developed and validated. Liquid-liquid extraction with tert-butyl methyl ether was used for tissue sample preparation and docetaxel was used as the internal standard. Paclitaxel and docetaxel were separated on a 200 mm x 4.6 mm x 5 microm C(18) column and quantified using a triple-quadrupole mass spectrometer operating in positive ion electrospray selective reaction monitoring mode (ESI(+)-SRM) with a total run time of 6.0 min. The peak area of the m/z 876.3 --> 307.9 transition of paclitaxel is measured versus that of the m/z 830.3 --> 549.1 transition of docetaxel to generate the standard curves. The standard curves were linear over the concentration range of 0.2008-2008 ng/mL for different tissues. The method had high extraction recovery (>90%) and accuracy (>90%) with the intra-day and inter-day precision <15%. Frozen stability, freeze/thaw stability, extraction stability and solution stability at ambient temperature were examined, which indicated the tissue samples should be extracted within 5 days and avoid being frozen and thawed repeatedly over 5 times. Extracted samples after evaporation could be stored at -20 degrees C for 20 days without drug degradation and no degradation was also observed after solution samples were left to stand at ambient temperature for 24 h. This assay was used to support an in vivo biodistribution study of PTX-NLP in rats.  相似文献   

10.
We report a selective, sensitive and fast liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of diallyldimethylammonium chloride (DADMAC) in water. Hydrophilic interaction liquid chromatography (HILIC) was used to avoid ion-pairing reagents, which are generally employed to retain cationic compounds. The complementary information obtained in a triple quadrupole mass spectrometer and in an ion trap Orbitrap has been used to study the fragmentation of the DADMAC cation [M](+) and for the correct assignment of the products ions. The HILIC/MS/MS method developed, using electrospray ionization in positive ion mode and selected reaction monitoring (SRM) acquisition mode, led to a reliable determination and confirmation of the DADMAC cation in water samples down to 50 ng L(-1). The low detection limit achieved, in combination with the absence of matrix effects, allowed the direct analysis of samples without any pretreatment, preconcentration or clean-up step. DADMAC was determined in samples collected in a drinking water treatment plant (DWTP) in Barcelona (Spain) and it was found in the influent at the μg L(-1) level.  相似文献   

11.
Liquid chromatography/mass spectrometry (LC/MS) has been applied to the analysis of triphenylboron, which has been produced as a substitute for organotin compounds, in water. Although commercial triphenylboron compounds are produced as pyridinyl complexes, the chemical form in water is supposed to be mainly triphenylboron after liberating pyridine. The triphenylborons were extracted from water with an Empore C18 extraction disk under acidic condition, and the extracts were introduced directly into a liquid chromatograph-mass spectrometer equipped with a negative ion electrospray ionization interface. Identification of the compounds was performed with specific ions produced from the triphenylboron, and a quantitative analysis was carried out using the peak areas. The average recoveries from distilled water, seawater and river water at 0.30 ng/ml were 92.3, 100 and 85.3%, respectively. A detection limit of 0.023 ng/ml for triphenylboron was achieved.  相似文献   

12.
Fluorotelomer alcohols (FTOHs) are important polyfluorinated raw materials that belong to the general category of perfluoroalkyl substances (PFAS). PFAS, including perfluoroalkyl carboxylates (PFCAs) and perfluoroalkyl sulfonates, have recently attracted considerable attention because they are persistent and found globally in the environment. FTOHs are precursors that may degrade in the environment to PFCAs. The development of analytical methods for determination FTOHs in environmental samples is necessary to determine the environmental presence of FTOHs. This work presents the development and validation of a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of FTOHs (6-2, 8-2, 10-2) in aqueous samples. Chromatographic conditions were optimized in order to obtain focused FTOH chromatographic peaks. The mobile phase and mass spectrometric conditions were optimized to enable formation of deprotonated FTOH molecules in the negative ion electrospray mode. Two extraction methods were investigated using acetonitrile and methyl tert-butyl ether (MTBE). These methods were validated for a range of environmental water samples fortified with FTOHs at three different levels. Both extraction methods resulted in recoveries from 70 to 120%. Detection limits of FTOHs were estimated to be approximately 0.09 ng/mL for LC/MS/MS detection. An LC/MS method was also developed for FTOH determination with an estimated 1.2 ng/mL limit of detection. Various sample storage scenarios were investigated. It was determined that the aqueous samples of FTOHs are best preserved by storing them frozen in sealed vials with aluminum foil lined septa.  相似文献   

13.
This paper describes the development of a high performance liquid chromatography/tandem mass spectrometric (MS/MS) procedure for the specific qualitative and quantitative analysis of lipid aldehydes in biological matrices. A derivatisation method, which results in molecules that exhibit a common product ion on MS/MS, permits informative precursor ion scans, at high sensitivity. This has been applied to the examination of plasma in order to examine the production of aldehydes consequent on in vitro lipid oxidation. Quantitative analysis of target molecules using multiple reaction monitoring has been developed to permit quantitation in the same matrices.  相似文献   

14.
15.
16.
High-throughput chiral liquid chromatography/tandem mass spectrometry   总被引:3,自引:0,他引:3  
Chiral liquid chromatography is a well-established area of bioanalytical chemistry and is often used during the processes of drug discovery and development. The development and use of a chiral drug require the understanding of the pharmacokinetic characteristics of each of the enantiomers, including potential differences in their absorption, distribution, metabolism, and excretion. Chromatographic techniques coupled to atmospheric pressure ionization-tandem mass spectrometry have shown potential as sensitive and robust tools in the quantitative and qualitative determination of enantiomers in biologic fluids and tissue extracts. However, development of a chiral liquid chromatography method requires time-consuming procedures that are devised empirically. Clearly, there is an incentive to design chromatographic approaches that are easy to use, compatible with mass spectrometry ionization interface conditions, exhibit relatively short run times without compromising sensitivity, and offer a broad analyte specificity. For these reasons, the present paper explores the feasibility of the bonded macrocyclic glycopeptide phases (teicoplanin and vancomycin) for analysis by chiral liquid chromatography/tandem mass spectrometry. Ritalinic acid, pindolol, fluoxetine, oxazepam, propranolol, terbutaline, metoprolol, and nicardipine were tested in this study. Furthermore, an example of a simultaneous chiral LC/MS/MS detection (chromatographic run time approximately 10 min) of four pharmaceutical products resulting in baseline resolutions of all four pairs of enantiomers is presented. Methanol, an MS-compatible mobile phase, was utilized in all the experiments.  相似文献   

17.
18.
Capillary liquid chromatography (cLC) hyphenated with tandem mass spectrometry (MS-MS) was used to separate and quantitate trace concentrations of five estrogens in aqueous samples. New C(18)-based sorption materials bound to the silica support by monomeric and polymeric mechanisms were compared and tested for solid-phase extraction (SPE) of selected analytes with respect to optimization of their preconcentration yield. Application of an endcapped, monomer-bound preconcentration Discovery DSC-18Lt column under the optimized conditions provides yields in the range from 95 to 100% with a high repeatability (n=3, RSD≤7.2%). Using the electrospray ionization in the positive mode (ESI+), the cLC-MS-MS system (the Zorbax SB C18 capillary column and a binary mobile phase of acetonitrile and water containing 0.1% formic acid in both the components) was optimized to attain a sufficient retention of the early eluting estriol, a satisfactory resolution of the analytes and the maximum sensitivity of the determination. Both the isocratic and gradient elution were used and the optimized gradient method permitted analyses of aqueous environmental samples in 14 min within a linearity range from 6.1 to 25.0 (LOQ of analytes) to 500 ng/L and with a very good linearity (r>0.9981) for all the estrogens studied. The detection limits are in the range from 3.0 to 6.8 ng/L (1 μL injection volume). Six environmental water samples were analyzed and the studied estrogens were found in the Vltava river sample collected in Prague (13.2 ng/L for 17β-estradiol) and in the inlet to the wastewater treatment plant in Prague, at an overall concentration of 371.4 ng/L.  相似文献   

19.
20.
A reliable, sensitive and selective liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed to determine four trichothecene mycotoxins (nivalenol, deoxynivalenol, fusarenon X and 3-acetyldeoxynivalenol) in maize. Sample preparation was performed by extracting the analytes with a mixture of acetonitrile and water, followed by a solid-phase extraction with Carbograph-4 cartridges as the purification step. For the LC/MS/MS analysis two interfacing systems, Turbo IonSpray (TISP) and atmospheric pressure chemical ionization (APCI), were compared in both negative and positive ion modes. LC and MS parameters were optimized to achieve better results and sensitivity. The effect of mobile phase modifiers such as ammonium acetate and formic acid on the ionization yield was also evaluated. The best results were obtained using the electrospray ionization (ESI) interface in negative ion mode and the multiple reaction monitoring mode (MRM) for the quantitation. The detection limits ranged between 10 ng/g for fusarenon X and 1.5 ng/g for deoxynivalenol. A linear working range was achieved with a standard deviation between 3 and 10% and recovery rates from the maize samples above 81%. The procedure was applied to the analysis of a set of maize samples collected from farms located in different areas of northern and central Italy. The investigated samples turned out to be contaminated primarily with deoxynivalenol and, to a minor extent, with its derivatives.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号