首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
Uncertainties associated with field assessments of daily exposure to whole-body vibration (WBV) have been investigated in four categories of work vehicles (fork lift trucks, wheel loaders, garbage trucks, buses) in different working conditions. A total of 50 vehicles were included in the study. WBV exposures were measured in different field conditions in marble quarries, marble laboratories, dockyards, paper mills, transportation and public utilities: over 700 individual vibration measurements were analysed to quantify relevant uncertainty components due to changes in the operators’ working methods, variations in the characteristics and conditions of the machines, changes in the characteristics of the travelling surface, uncertainty in the evaluation of exposure duration, and systematic errors due to measurement equipment. The methods used in the study to calculate measurement uncertainties are in accordance with the ISO publication “Guide to the Expression of Uncertainty in Measurement”. The study made it possible to isolate major sources of uncertainty in field assessment of daily exposures to WBV. The investigation revealed that, in all the field conditions, differences in the characteristics of the machines and/or in working cycles were the most relevant uncertainty components. The overall relative uncertainty p in WBV field assessment was in the range 14% <p<32%, whereas the relative uncertainty caused by transducer and measurement equipment in a correctly calibrated system is less than 4%.  相似文献   

2.
The prevalence of low back pain (LBP) was investigated in 598 Italian professional drivers exposed to whole-body vibration (WBV) and ergonomic risk factors (drivers of earth moving machines, fork-lift truck drivers, truck drivers, bus drivers). The control group consisted of a small sample of 30 fire inspectors not exposed to WBV. Personal, occupational and health histories were collected by means of a structured questionnaire. Vibration measurements were performed on representative samples of the machines and vehicles used by the driver groups. From the vibration magnitudes and exposure durations, alternative measures of vibration dose were estimated for each subject. Daily vibration exposure, expressed in terms of 8-h energy-equivalent frequency-weighted acceleration, A(8), averaged 0.28-0.61 (range 0.10-1.18) m s−2 rms in the driver groups. Duration of exposure to WBV ranged between 1 and 41 years. The 7-day and 12-month prevalence of LBP was greater in the driver groups than in the controls. In the professional drivers, the occurrence of 12-month LBP, high intensity of LBP (Von Korff pain scale score ?5), and LBP disability (Roland & Morris disability scale score ?12) significantly increased with increasing cumulative vibration exposure. Even though several alternative measures of vibration exposure were associated with LBP outcomes, nevertheless a more regular trend of association with LBP was found for vibration dose expressed as ∑aviti (m s−2 h), in which the frequency-weighted acceleration, av, and lifetime exposure duration, t, were given equal weight. In multivariate data analysis, individual characteristics (e.g. age, body mass index) and a physical load index (derived from combining manual materials handling and awkward postures) were significantly associated with LBP outcomes, while psychosocial work factors (e.g. job decision, job support) showed a marginal relation to LBP. This study tends to confirm that professional driving in industry is associated with an increased risk of work-related LBP. Exposure to WBV and physical loading factors at work are important components of the multifactorial origin of LBP in professional drivers.  相似文献   

3.
Seats with horizontal suspensions can help to reduce detrimental effects of whole-body vibration (WBV) on health, comfort and performance. Two seats were used to examine the effect of body mass and WBV-magnitude on the transmission of WBV from the seat base to the cushion. Both seats have suspension in the x-direction while Seat 2 has suspension also in the y-direction. Twelve subjects with a body mass ranging from 59.0 to 97.3 kg volunteered for the study. A set of anthropometric characteristics was acquired. Three magnitudes of WBV were used with a truck-like signal (Seat 1, 0.3-0.59 m s−2wd-weighted rms values at the seat base, x-direction) and a tractor-like signal (Seat 2, 0.55-1.09 m s−2wd-weighted rms values at the seat base, x-direction, 0.52-1.07 m s−2wd-weighted rms values, y-direction). The magnitude of WBV had a significant effect on the transmissibility characterized by SEAT-values. A significant influence of the body mass on SEAT-values was found for the y-direction only. Other anthropometric characteristics proved to be more important for the prediction of SEAT values by multiple regressions. There was no significant correlation of SEAT-values, x-direction, with the body mass. Other anthropometric characteristics enabled a satisfactory prediction of SEAT values also for x-direction in several cases. Tests with only two subjects of extreme body mass are not suited to obtain comparable and representative results required for a comparison of different seats with a suspension in the x-direction. The effect of the WBV-magnitude on the WBV-transmissibility should be considered with the design, testing and application of suspended seats.  相似文献   

4.
Humans are exposed to whole-body vibration in many types of environment. In almost all cases, the vibration to which the human is exposed comprises multi-axis vibration, such that vibration occurs in all directions simultaneously. Despite the complex nature of vibration to which humans are exposed in the workplace, almost all laboratory studies investigating the biomechanical response of the person have been completed using single-axis simulators. This paper presents a study whereby 15 male subjects were exposed to single-axis whole-body vibration in the x-, y- and z-directions and dual-axis vibration in the xy-, xz-, and yz-directions using a 6 degree-of-freedom vibration simulator. All vibration magnitudes were 0.4 ms−2 rms in each axis. Acceleration and force was measured in the x-, y-, and z-direction during all trials. Subjects sat in two postures (‘back-on’ and ‘back-off’) on a flat rigid seat. Apparent masses measured using single-axis and dual-axis vibration stimuli showed comparable results; similarly, cross-axis apparent masses (i.e. the ratio of the force in one direction to the acceleration in another direction) were almost identical for the single- and dual-axis vibration stimuli. All results were in agreement with data previously published using single-axis vibration. In most cases, the peaks in the apparent mass and the cross-axis apparent mass occurred at a slightly lower frequency for the dual-axis vibration than for the single-axis vibration. It is hypothesised that this change is due to a nonlinear effect, analogous to that which occurs with increasing vibration magnitude for single-axis vibration.  相似文献   

5.
US locomotive operators have exposure to multi-axis whole-body vibration (WBV) and shocks while seated. This study assessed operator-related and ergonomic seating design factors that may have confounding or mitigating influence on WBV exposure and its effects. Vibration exposure was measured according to international guidelines (ISO 2631-1; 1997); ergonomic work place factors and vibration effects were studied with a cross-sectional survey instrument distributed to a randomly selected group of railroad engineers (n=2546) and a control group; and during vehicle inspections. The survey response rate was 47% for the RR engineers (n=1195) and 41% for the controls (n=323). Results of the mean basic vibration measurements were for the x, y, z-direction and vector sum 0.14, 0.22, 0.28 and 0.49 m/s2 respectively; almost all crest factors (CF), MTVV and VDV values were above the critical ratios given in ISO 2631-1. The prevalence of serious neck and lower back disorders among locomotive engineers was found to be nearly double that of the sedentary control group without such exposure. Railroad engineers rated their seats mostly unacceptable regarding different adjustment and comfort aspects (3.02-3.51; scale 1=excellent to 4=unacceptable), while the control group rated their chairs more favorably (1.96-3.44). Existing cab and seat design in locomotives can result in prolonged forced awkward spinal posture of the operator combined with WBV exposure. In a logistic regression analysis, time at work being bothered by vibration (h/day) was significantly associated with an increased risk of low back pain, shoulder and neck pain, and sciatic pain among railroad engineers. Customized vibration attenuation seats and improved cab design of the locomotive controls should be further investigated.  相似文献   

6.
The biodynamic responses of the seated human body to whole-body vibration vary considerably between people, but the reasons for the variability are not well understood. This study was designed to determine how the physical characteristics of people affect their apparent mass and whether inter-subject variability is influenced by the magnitude of vibration and the support of a seat backrest. The vertical apparent masses of 80 seated adults (41 males and 39 females aged 18-65) were measured at frequencies between 0.6 and 20 Hz with four backrest conditions (no backrest, upright rigid backrest, reclined rigid backrest, reclined foam backrest) and with three magnitudes of random vibration (0.5, 1.0 and 1.5 m s-2 rms). Relationships between subject physical characteristics (age, gender, weight, and anthropometry) and subject apparent mass were investigated with multiple regression models. The strongest predictor of the modulus of the vertical apparent mass at 0.6 Hz, at resonance, and at 12 Hz was body weight, with other factors having only a marginal effect. After correction for other variables, the principal resonance frequency was most consistently associated with age and body mass index. As age increased from 18 to 65 years, the resonance frequency increased by up to 1.7 Hz, and when the body mass index was increased from 18 to 34 kg m−2 the resonance frequency decreased by up to 1.7 Hz. These changes were greater than the 0.9-Hz increase in resonance frequency between sitting without a backrest and sitting with a reclined rigid backrest, and greater than the 1.0-Hz reduction in resonance frequency when the magnitude of vibration increased from 0.5 to 1.5 m s−2 rms. It is concluded that the effects of age, body mass index, posture, vibration magnitude, and weight should be taken into account when defining the vertical apparent mass of the seated human body.  相似文献   

7.
The apparent mass and seat-to-head-transmissibility response functions of the seated human body were investigated under exposures to fore-aft (x), vertical (z), and combined fore-aft and vertical (x and z) axis whole-body vibration. The coupling effects of dual-axis vibration were investigated using two different frequency response function estimators based upon the cross- and auto-spectral densities of the response and excitation signals, denoted as H1 and Hv estimators, respectively. The experiments were performed to measure the biodynamic responses to single and uncorrelated dual-axis vibration, and to study the effects of hands support, back support and vibration magnitude on the body interactions with the seatpan and the backrest, characterized in terms of apparent masses and the vibration transmitted to the head. The data were acquired with 9 subjects exposed to two different magnitudes of vibration applied along the individual x- and z-axis (0.25 and 0.4 m/s2 rms), and along both the axis (0.28 and 0.4 m/s2 rms along each axis) in the 0.5-20 Hz frequency range. The two methods resulted in identical single-axis responses but considerably different dual-axis responses. The dual-axis responses derived from the Hv estimator revealed notable effects of dual-axis vibration, as they comprised both the direct and cross-axis responses observed under single axis vibration. Such effect, termed as the coupling effect, was not evident in the dual-axis responses derived using the commonly used H1 estimator. The results also revealed significant effects of hands and back support conditions on the coupling effects and the measured responses. The back support constrained the upper body movements and thus showed relatively weaker coupling compared to that observed in the responses without the back support. The effect of hand support was also pronounced under the fore-aft vibration. The results suggest that a better understanding of the seated human body responses to uncorrelated multi-axis whole-body vibration could be developed using the power-spectral-density based Hv estimator.  相似文献   

8.
Using a repeated measures study design, three different seats were evaluated as 12 metropolitan bus drivers drove a standardized test route including city streets, old and new freeways, and a street segment containing 10 large speed humps. Three comparisons were made: (1) comparing seats made by different manufactures (Seats 1 and 2), (2) comparing seats with a standard foam (Seat 2) and silicone foam (Seat 3) seat pans, and (3) comparing WBV exposures based on individual factors such as seat pressure settings and body weight. Whole body vibration (WBV) exposures were measured using a tri-axial seat pan accelerometer and the attenuation capabilities of each seat were evaluated by comparing the vibrations measured at the floor and seat of the bus. There were significant WBV exposure differences between the various street types, which was shown across all seat types. The city street and older freeway segments had the highest WBV exposures with both segments producing WBV exposures slightly above the action limit for vibration dose value (VDV). Relative to Seat 2, Seat 1 performed better at attenuating impulsive and shock related WBV exposures; however, neither seat performed significantly better when average vibration (Aw) and VDV WBV exposures were compared. In addition, no performance differences were seen between the standard foam (Seat 2) and silicone foam (Seat 3) seat pans. Seat suspension stiffness (air pressure) was also examined, and the results indicated that the higher the seat air pressure the lower the Aw, VDV, and static compressive dose (Sed) vibration exposures. This study provided a unique opportunity to evaluate on-the-job whole body vibration exposures in a standardized, controlled setting.  相似文献   

9.
Ytterbium tri-fluoromethanesulfonate (YbTFMS) single crystals are prepared from the slow evaporation of the aqueous solution of YbTFMS and the principal magnetic susceptibility perpendicular to the c-axis of the hexagonal crystal (χ) is measured from 300 K down to 13 K. Principal magnetic anisotropy Δχ(=χχ) is measured from 300 K down to 80 K which provides principal magnetic susceptibility parallel to the c-axis (χ) down to 80 K. Very good theoretical simulation of the observed magnetic properties of YbTFMS has been obtained using one electron crystal field (CF) analysis having C3h site symmetry. No signature of ordering effect in the observed magnetic data is noticed down to the lowest temperature (13 K) attained, indicating the inter-ionic interaction to be of predominantly dipolar type. The calculated g-values are found to be g=2.67 and g=2.51, respectively. CF analysis provides the electronic specific heat which gives two Schottky anomalies in its thermal variation down to ∼13 K. The temperature dependences of quadrupole splitting and hyperfine heat capacity are studied from the necessary information obtained from the CF analysis.  相似文献   

10.
Biodynamic responses of the hand-arm system have been mostly characterized in terms of driving-point force-motion relationships, which have also served as the primary basis for developing the mechanical-equivalent models. The knowledge of localized vibration responses of the hand-arm segments could help derive more effective biodynamic models. In this study, the transmission of zh-axis handle vibration to the wrist, elbow and the shoulder of the human hand and arm are characterized in the laboratory for the bent-arm and extended arm postures. The experiments involved six subjects grasping a handle subject to two different magnitudes of broad-band random vibration, and nine different combinations of hand grip and push forces. The vibration transmissibility data were acquired in the zh- and yh-axis at the wrist and shoulder, and along all the three axes around the elbow joint. The results show that the human hand-arm system in an extended arm posture amplifies the vibration transmitted to the upper-arm and the whole-body at frequencies below 25 Hz, but attenuates the vibration above 25 Hz more effectively than the bent-arm posture, except at the shoulder. The magnitudes of transmitted vibration under an extended arm posture along the yh-axis were observed to be nearly twice those for the bent-arm posture in the low frequency region. The results further showed that variations in the grip force mostly affect vibration transmissibility and characteristic frequencies of the forearm, while changes in the push force influenced the dynamic characteristics of the entire hand-arm system. The magnitudes of transmitted vibration in the vicinity of the characteristic frequencies were influenced by the handle vibration magnitude.  相似文献   

11.
The driving-point dynamic responses of standing people (e.g. their mechanical impedance or apparent mass) influence their dynamic interactions with structures on which they are supported. The apparent mass of the standing body has been reported previously for vertical excitation but not for lateral or fore-and-aft excitation. Twelve standing male subjects were exposed to fore-and-aft and lateral random vibration over the frequency range 0.1-5.0 Hz for 180 s at four vibration magnitudes: 0.016, 0.0315, 0.063, and 0.125 m s−2 rms. With lateral excitation at 0.063 m s−2 rms, subjects also stood with three separations of the feet. The dynamic forces measured at the driving-point in each of the three translational axes (i.e. fore-and-aft, lateral and vertical) showed components not linearly related to the input vibration, and not seen in previous studies with standing subjects exposed to vertical vibration or seated subjects exposed to vertical or horizontal vibration. A principal peak in the lateral apparent mass around 0.5 Hz tended to decrease in both frequency and magnitude with increasing magnitude of vibration and increase with increasing separation of the feet. The fore-and-aft apparent mass appeared to peak at a frequency lower than the lowest frequency used in the study.  相似文献   

12.
In this paper, we report the existence of anisotropic behavior along the crystallographic axes in optical, electrical and thermal properties of lithium tri borate, a recently developed vacuum UV-NLO material. The variation of refractive index with the wavelength along the crystallographic axes was investigated by prism coupling method. The results of impedance spectroscopy measurement reveal the presence of a strong anisotropy in ionic conductivity and dielectric constant along the axes and also show the super-ionic conduction behavior along the c-axis with the activation energy of Δ∼0.20 eV. A thermo-mechanical study in the temperature range of 300-900 K indicates the existence of a strong variation in the linear thermal expansion coefficient (positive value along the a-axis, and negative value along the c-axis) of LiB3O5 crystals.  相似文献   

13.
This study aimed to utilise a tissue mimicking material (TMM) in order to embed in vitro carotid plaque tissue so that its acoustic properties could be assessed. Here, an International Electrotechnical Commission (IEC) agar-based TMM was adapted to a clear gel by removal of the particulates. This clear TMM was measured with sound speed at 1540 ms−1 and an attenuation coefficient of 0.15 dB cm−1 MHz−1. Composite sound speed was then measured through the embedded material using a scanning acoustic microscope (SAM). Both broadband reflection and transmission techniques were performed on each plaque specimen in order to ensure the consistency of the measurement of sound speed, both at 21 °C and 37 °C. The plaque was measured at two temperatures to investigate any effect on the lipid content of the plaque. The contour maps from its associated attenuation plots were used to match the speed data to the photographic mask of the plaque outline. This physical matching was then used to derive the sound speed from the percentage composition seen in the histological data by solution of simultaneous equations. Individual speed values for five plaque components were derived; TMM, elastin, fibrous/collagen, calcification and lipid. The results for derived sound speed in the TMM were consistently close to the expected value of soft tissue, 1540 ms−1. The fibrous tissue showed a mean value of 1584 ms−1 at 37 °C. The derived sound speeds for elastic and lipid exhibited large inter-quartile ranges. The calcification had higher sound speed than the other plaque components at 1760–2000 ms−1. The limitations here lay in the difficulties in the matching process caused by the inhomogeneity of the plaque material and shrinkage during the histological process. Future work may concentrate on more homogeneous material in order to derive sound speed data for separate components. Nevertheless, this study increases the known data ranges of the individual components within a plaque. This information may be used help to assess the mechanical properties and structural integrity and its associated vulnerability or risk of embolization in future diagnostic ultrasound techniques.  相似文献   

14.
Al-N-codoped ZnO films were fabricated by RF magnetron sputtering in the ambient of N2 and O2 on silicon (1 0 0) and homo-buffer layer, subsequently, annealed in O2 at low pressure. X-ray diffraction (XRD) spectra show that as-grown and 600 °C annealed films grown by codoping method are prolonged along crystal c-axis. However, they are not prolonged in (0 0 1) plane vertical to c-axis. The films annealed at 800 °C are not prolonged in any directions. Codoping makes ZnO films unidirectional variation. X-ray photoelectron spectroscopy (XPS) shows that Al content hardly varies and N escapes with increasing annealing temperature from 600 °C to 800 °C.  相似文献   

15.
16.
The aim of this study was to investigate the effects of exposure to whole-body vibration (WBV) and the ISO 2631/1-1997 frequency weighting on gastric motility. The gastric motility was measured by electrogastrography (EGG) in nine healthy volunteers. Sinusoidal vertical vibration at a frequency of 4, 6·3, 8, 12, 16, 31·5, or 63 Hz was given to the subjects for 10 min. The magnitude of exposure at 4 Hz was 1·0m/s2 (r.m.s.). The magnitudes of the other frequencies gave the same frequency-weighted acceleration according to ISO 2631/1-1997. The pattern of the dominant frequency histogram (DFH) was changed to a broad distribution pattern by vibration exposure. Vibration exposure had the effect of significantly reducing the percentage of time for which the dominant component had a normal rhythm and increasing the percentage of time for which there was tachygastria (p<0·05). Vibration exposure generally reduced the mean percentage of time with the dominant frequency in normal rhythm component. There was a significant difference between the condition of no vibration and exposure to 4 and 6·3 Hz of vibration frequency (p<0·05). The frequency weighting curve given in ISO 2631/1-1997 was not adequate for use in evaluating the physiological effects of WBV exposure on gastric motility.  相似文献   

17.
Time series of ac conductivities are measured at 2 kHz along three crystal directions in terbium nitrate crystal below 50 K. The anisotropy is found in the structure of the fluctuation observed in the time series of the conductivities. The bursts with non-periodic oscillations are found in only the measurements of the time series of the ac conductivities for one direction perpendicular to the c-axis (c2-axis). The anisotropy is seen in probability distribution functions and power spectral ones derived from the time series of the conductivities. The characteristic behaviors are found in the time series of the conductivity for the one crystal direction perpendicular to the c-axis. Asymmetric non-Gaussian line shape of the probability distribution function is seen for the c2-axis. Chaotic behavior is also found in the function of the correlation exponent to the embedding dimension derived from the time series of the conductivities.  相似文献   

18.
Based on the coupled mode equations and elastic optic effect theory, the relationship between polarization maintaining fiber (PMF) beat length and external pressure was analyzed. Moreover, the beat length variation with different external pressure values F as well as angles θ between the pressure direction and PMF's x-axis was calculated numerically. The results demonstrated that the beat length variation was determined both by F and θ simultaneously. When F was a constant, the beat length was changed periodically in π cycle sinusoidal form with θ variation. Then, the minimum and maximum values of beat length would be obtained when θ were even and odd multiples of π/2, respectively. Meanwhile, the beat length variation was linear with F as θ was fixed. In this situation and with F increasing, if θ ∈ ( + π/4,  + 3π/4) (k ∈ Z), the beat length would increase linearly; otherwise, the beat length variation would be in the opposite direction while θ ∈ ( − π/4,  + π/4) (k ∈ Z); however, it remained almost unchanged in the case of θ =  ± π/4 (k ∈ Z). Finally, the beat length was measured with different pressure values F and angles θ based on a Sagnac interferometer system, and the results shown a great agreement with the theoretical analysis and simulation.  相似文献   

19.
Oscillatory motions can cause injury in transport when standing passengers or crew lose balance and fall. To predict the loss of balance of standing people, a model is required of the relationship between the input motion and the stability of the human body. This experimental study investigated the effect of frequency, magnitude and direction of oscillation on the postural stability of standing subjects and whether response to rotational oscillation can be predicted from knowledge of response to translational oscillation.Twelve male subjects stood on a floor that oscillated in either horizontal (fore-and-aft or lateral) or rotational (pitch or roll) directions. The oscillations were one-third octave bands of random motion centred on five preferred octave centre frequencies (0.125, 0.25, 0.5, 1.0, and 2.0 Hz). The horizontal motions were presented at each of four velocities (0.04, 0.062, 0.099, and 0.16 ms−1 rms) and the rotational motions were presented at each of four rotational angles (0.73, 1.46, 2.92, and 5.85° rms) corresponding to four accelerations (0.125, 0.25, 0.5, and 1.0 ms−2 rms), where the acceleration is that caused by rotation through the gravitational vector. Postural stability was determined by subjective methods and by measuring the displacement of the centre of pressure at the feet during horizontal oscillation.During horizontal oscillation, increases in motion magnitude increased instability and, with the same velocity at all frequencies from 0.125 to 2.0 Hz, most instability occurred in the region of 0.5 Hz. Fore-and-aft oscillation produced more instability than lateral oscillation, although displacements of the centre of pressure were similar in both directions. With the same angular displacement at all frequencies from 0.125 to 2.0 Hz, pitch oscillation caused more instability than roll oscillation, but in both directions instability increased with increased frequency of oscillation. Frequency weightings for acceleration in the plane of the floor during translational and rotational excitation show the significance of low-frequency translational oscillation and high-frequency rotational motion, and show that it is necessary to know whether the measured acceleration is caused by translation or rotation through gravity.  相似文献   

20.
A novel setup for imaging and interferometry through reflection holography with Bi12TiO20(BTO) sillenite photorefractive crystals is proposed. A variation of the lensless Denisiuk arrangement was developed resulting in a compact, robust and simple interferometer. A red He-Ne laser was used as light source and the holographic recording occurred by diffusion with the grating vector parallel to the crystal [0 0 1]-axis. In order to enhance the holographic image quality and reduce noise a polarizing beam splitter (PBS) was positioned at the BTO input and the crystal was tilted around the [0 0 1]-axis. This enabled the orthogonally polarized transmission and diffracted beams to be separated by the PBS, providing the holographic image only. The possibility of performing deformation and strain analysis as well as vibration measurement of small objects was demonstrated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号