首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A need still exists for a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method that can detect broad classes of glutathione (GSH) conjugates and provide characterization of their structures. We now describe the development of a method that multiplexes high-resolution accurate mass analysis with isotope pattern triggered data-dependent product ion scans, for simultaneous detection and structural elucidation of GSH conjugates within a single analysis using a LTQ/Orbitrap. This method was initially developed to detect GSH conjugates generated from incubating 10 microM test compound with pooled human liver microsomes fortified with NADPH-regenerating system and a 2:1 ratio of 5 mM glutathione and [(13)C(2) (15)N-Gly]glutathione. The GSH conjugates were detected by isotope search of mass defect filtered and control subtracted full scan accurate MS data using MetWorks software. This was followed by elucidation of reactive intermediate structures using chemical formulae for both protonated molecules and their product ions from accurate masses in a single analysis. The mass accuracies measured for the precursor and product ions by the Orbitrap were <2 ppm in external mass calibration mode. Successful detection and characterization of GSH conjugates of acetaminophen, tienilic acid, clozapine, ticlopidine and mifepristone validated this method. In each case, the detected GSH conjugates were within the top five hits by isotope search. This method also has a broader detection capability since it is independent of the collision-induced dissociation behavior of the GSH conjugates. Furthermore, this method is amenable to a broad class of reactive intermediate trapping agents as exemplified by the simultaneous detection and structural elucidation of the cyano-N-methylene iminium ion conjugates of verapamil and its O-desmethyl metabolites, which we report for the first time. In addition to the chemically tagged reactive intermediates, this method also provides information on stable metabolites from the full scan accurate MS data.  相似文献   

2.
We report herein, facile metabolite identification workflow on the anti-depressant nefazodone, which is derived from accurate mass measurements based on a single run/experimental analysis. A hybrid LTQ/orbitrap mass spectrometer was used to obtain accurate mass full scan MS and MS/MS in a data-dependent fashion to eliminate the reliance on a parent mass list. Initial screening utilized a high mass tolerance ( approximately 10 ppm) to filter the full scan MS data for previously reported nefazodone metabolites. The tight mass tolerance reduces or eliminates background chemical noise, dramatically increasing sensitivity for confirming or eliminating the presence of metabolites as well as isobaric forms. The full scan accurate mass analysis of suspected metabolites can be confirmed or refuted using three primary tools: (1) predictive chemical formula and corresponding mass error analysis, (2) rings-plus-double bonds, and (3) accurate mass product ion spectra of parent and suspected metabolites. Accurate mass characterization of the parent ion structure provided the basis for assessing structural assignment for metabolites. Metabolites were also characterized using parent product ion m/z values to filter all tandem mass spectra for identification of precursor ions yielding similar product ions. Identified metabolite parent masses were subjected to chemical formula calculator based on accurate mass as well as bond saturation. Further analysis of potential nefazodone metabolites was executed using accurate mass product ion spectra. Reported mass measurement errors for all full scan MS and MS/MS spectra was <3 ppm, regardless of relative ion abundance, which enabled the use of predictive software in determining product ion structure. The ability to conduct biotransformation profiling via tandem mass spectrometry coupled with accurate mass measurements, all in a single experimental run, is clearly one of the most attractive features of this methodology.  相似文献   

3.
Current biological studies have been advanced by the continuous development of robust, accurate, and sensitive mass spectrometric technologies. The MALDI LTQ Orbitrap is a new addition to the Orbitrap configurations, known for their high resolving power and accuracy. This configuration provides features inherent to the MALDI source, such as reduced spectra complexity, forgiveness to contaminants, and sample retention for follow-up analyses with targeted or hypothesis-driven questions. Here we investigate its performance for characterizing the composition of isolated protein complexes. To facilitate the assessment, we selected two well characterized complexes from Saccharomyces cerevisiae, Apl1 and Nup84. Manual and automatic MS and MS/MS analyses readily resolved their compositions, with increased confidence of protein identification compared with our previous reports using MALDI QqTOF and MALDI IT. CID fragmentation of singly-charged peptides provided sufficient information for conclusive identification of the isolated proteins. We then assessed the resolution, accuracy, and sensitivity provided by this instrument in the context of analyzing the isolated protein assemblies. Our analysis of complex mixtures of singly-charged ions up to m/z 4000 showed that (1) the resolving power, inversely proportional to the square root of m/z, had over four orders of magnitude dynamic range; (2) internal calibration led to improved accuracy, with an average absolute mass error of 0. 5 ppm and a distribution centered at 0 ppm; and (3) subfemtomole sensitivity was achieved using both CHCA and DHB matrices. Additionally, our analyses of a synthetic phosphorylated peptide in mixtures showed subfemtomole level of detection using neutral loss scanning.  相似文献   

4.
Epimedium is an important traditional Chinese medicine that is widely used throughout China as a tonic, aphrodisiac, and antirheumatic medicine. Flavonoids are considered to be the active compounds in Epimedium. In the study reported here, high-performance liquid chromatography coupled with Fourier transform-ion cyclotron resonance mass spectrometry (HPLC/FTICR-MS) was developed to identify active compounds and their metabolites after oral administration of a herbal extract of Epimedium koreanum Nakai to rats, using parent mass list triggered data-dependent multiple-stage accurate mass analysis at a resolving power of 100 000 in the external calibration mode. Nine flavonoids were identified in rats. The chemical formulae with unsaturation numbers calculated from accurate m/z values of precursor and product ions were used to assign the structures of metabolites and the chemical sites of metabolism. The mass accuracies obtained for all full-scan MS and MS(n) spectra were within 3 ppm (<1 ppm in most cases). The majority of the metabolites identified have been previously reported, but three compounds were noted for the first time in rats. By contrasting the analytical results obtained from the herbal extract with those obtained from biological specimens, the profile of flavonoid biotransformation in Epimedium was obtained and the metabolic pathways of these components, in rats, are described. The results should be of use in targeting potential active ingredients in Epimedium. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

5.
The applicability of ultra-performance liquid chromatography (UPLC) combined with full-scan accurate mass time-of-flight (TOF) and Orbitrap mass spectrometry (MS) to the analysis of hormone and veterinary drug residues was evaluated. Extracts from blank bovine hair were fortified with 14 steroid esters. UPLC-Orbitrap MS performed at a resolving power of 60,000 (FWHM) enabled the detection and accurate mass measurement (<3 ppm error) of all 14 steroid esters at low ng/g concentration level, despite the complex matrix background. A 5 ppm mass tolerance window proved to be essential to generate highly selective reconstructed ion chromatograms (RICs) having reduced background from the hair matrix. UPLC-Orbitrap MS at a lower resolving power of 7500 and UPLC-TOFMS at mass resolving power 10,000 failed both to detect all of the steroid esters in hair extracts owing to the inability to mass resolve analyte ions from co-eluting isobaric matrix compounds. In a second application, animal feed extracts were fortified with coccidiostats drugs at levels ranging from 240 to 1900 ng/g. UPLC-Orbitrap MS conducted at a resolving power of 7500 and 60,000 and UPLC-TOFMS detected all of the analytes at the lowest investigated level. Thanks to the higher analyte-to-matrix background ratio, the utilization of very narrow mass tolerance windows in the RIC was not required. This study demonstrates that even when the targeted sample preparation from conventional LC-MS/MS is applied to UPLC with full-scan accurate mass MS, false compliant (false negative) results can be obtained when the mass resolving power of the MS is insufficient to separate analyte ions from isobaric co-eluting sample matrix ions. The current trend towards more generic and less selective sample preparation is expected to aggravate this issue further.  相似文献   

6.
A MALDI source is interfaced to a modified LTQ Orbitrap XL instrument. This work gives insight into the MALDI source design and shows results obtained with the MALDI source coupled to an accurate mass, high-resolution hybrid mass spectrometer. MALDI-produced ions and fragment ions thereof produced in the mass spectrometer may be analyzed and detected by the Orbitrap analyzer at a maximum mass resolution of 100,000 (FWHM) at m/z 400 with high mass accuracy. An accuracy of ≤2 ppm is achieved by internal mass calibration using lock mass functionality; using external mass calibration, an accuracy of ≤3 ppm is routinely obtained. External mass calibration of the hybrid mass spectrometer is performed using a standard calibration mixture of different peptides and matrix components. The instrumental capabilities are demonstrated for analytical methodologies such as Protein ID using Peptide Mass Fingerprint (PMF) and MS/MS analyses of small molecule samples. Stability of mass accuracy and signal-to-noise ratio for low samples loads (on plates) are demonstrated as well as the experimental dynamic range using α-cyano-4-hydroxy cinnamic acid (CHCA) matrix.  相似文献   

7.
The yeast Saccharomyces cerevisiae synthesizes three classes of sphingolipids: inositolphosphoceramides (IPCs), mannosyl-inositolphosphoceramides (MIPCs), and mannosyl-diinositolphosphoceramides (M(IP)2C). Tandem mass spectrometry of their molecular anions on a hybrid quadrupole time-of-flight (QqTOF) instrument produced fragments of inositol-containing head groups, which were specific for each lipid class. MS(n) analysis performed on a hybrid linear ion trap-orbitrap (LTQ Orbitrap) mass spectrometer with better than 3 ppm mass accuracy identified fragment ions specific for the amide-linked fatty acid and the long chain base moieties in individual molecular species. By selecting m/z of class-specific fragment ions for multiple precursor ion scanning, we profiled yeast sphingolipids in total lipid extracts on a QqTOF mass spectrometer. Thus, a combination of QqTOF and LTQ Orbitrap mass spectrometry lends itself to rapid, comprehensive and structure-specific profiling of the molecular composition of sphingolipids and glycerophospholipids in important model organisms, such as fungi and plants.  相似文献   

8.
The objective of our work was to identify known and unknown metabolites of the drug NTBC (2‐(2‐nitro‐4‐trifluoromethylbenzoyl)‐1,3‐cyclohexanedione) in urine from patients during the treatment of hereditary tyrosinemia type 1 (HT‐1) disease, a severe inborn error of tyrosine metabolism. Two different mass spectrometric techniques, a triple stage quadrupole and an LTQ‐Orbitrap (Fourier transform mass spectrometry (FTMS)), were used for the identification and the structural elucidation of the detected metabolites. Initially, the mass spectrometric (MS) approach consisted of the precursor ion scan detection of the selected product ions, followed by the corresponding collision‐induced dissociation (CID) fragmentation analysis (MS2) for the targeted selected reaction monitoring (SRM) mode. Subsequently, accurate and high‐resolution full scan and MS/MS measurements were performed on the possible metabolites using the LTQ‐Orbitrap. Final confirmation of the identified metabolites was achieved by measuring commercially supplied or laboratory‐synthesized standards. Altogether six metabolites, including NTBC itself, were extracted, detected and identified. In addition, two new NTBC metabolites were unambiguously identified as amino acid conjugates, namely glycine‐NTBC and β‐alanine‐NTBC. These identifications were based on their characteristics of chromatographic retention times, protonated molecular ions, elemental compositions, product ions (using CID and higher‐energy C‐trap dissociation (HCD) techniques) and synthesized references. The applied MS strategy, based on two different MS platforms (LC/MS/MS and FTMS), allowed the rapid identification analysis of the drug metabolites from human extracts and could be used for pharmaceutical research and drug development. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
Analyzing brain microdialysate samples by mass spectrometry is challenging due to the high salt content of the artificial cerebral spinal fluid (aCSF), low analyte concentrations and small sample volumes collected. A drug and its major metabolites can be examined in brain microdialysates by targeted approaches such as selected reaction monitoring (SRM) which provides selectivity and high sensitivity. However, this approach is not well suited for metabolite profiling in the brain which aims to determine biotransformation pathways. Identifying minor metabolites, or metabolites that arise from brain metabolism, remains a challenge and, for a drug in early discovery, identification of metabolites present in the brain can provide useful information for understanding the pharmacological activity and potential toxicological liabilities of the drug. A method is described here for rapid metabolite profiling in brain microdialysates that involves sample clean‐up using C18 ZipTips to remove salts followed by direct infusion nanoelectrospray with an LTQ/Orbitrap mass spectrometer using real‐time internal recalibration. Full scan mass spectra acquired at high resolving power (100 K at m/z 400) were examined manually and with mass defect filtering. Metabolite identification was aided by sub‐parts‐per‐million mass accuracy and structural characterization was accomplished by tandem mass spectrometry (MS/MS) experiments in the Orbitrap or LTQ depending on the abundance of the metabolite. Using this approach, brain microdialysate samples from rats dosed with one of four CNS drugs (imipramine, reboxetine, citalopram or trazodone) were examined for metabolites. For each drug investigated, metabolites, some of which not previously reported in rat brain, were identified and characterized. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
Metabolite identification studies remain an integral part of pre-clinical and clinical drug development programs. Analysis of biological matrices, such as plasma, urine, feces and bile, pose challenges due to the large amounts of endogenous components that can mask a drug and its metabolites. Although direct infusion nanoelectrospray using capillaries has been used routinely for proteomic studies, metabolite identification has traditionally employed liquid chromatographic (LC) separation prior to analysis. A method is described here for rapid metabolite profiling in biological fluids that involves initial sample clean-up using pipette tips packed with reversed-phase material (i.e. ZipTips) to remove matrix components followed by direct infusion nanoelectrospray on an LTQ/Orbitrap mass spectrometer using a protonated polydimethylcyclosiloxane cluster ion for internal calibration. We re-examined samples collected from a prazosin metabolism study in the rat. Results are presented that demonstrate that sub parts-per-million accuracies can be achieved on molecular ions, facilitating identification of metabolites, and on product ions, facilitating structural assignments. The data also show that the high-resolution measurements (R = 100 000 at m/z 400) enable metabolites of interest to be resolved from endogenous components. The extended analysis times available with nanospray enables signal averaging for 1 min or more that is valuable when metabolites are present in low concentrations as encountered here in plasma and brain. Using this approach, the metabolic fate of a drug can be quickly obtained. A limitation of this approach is that metabolites that are structural isomers cannot be distinguished, although such information can be collected by LC/MS during follow-on experiments. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

11.
In addition to mass accuracy, the ability of a mass spectrometer to faithfully measure the isotopic distribution of an ion, defined as spectral accuracy, is also important. Although time-of-flight mass spectrometers are reported to possess high spectral accuracy capability compared with other mass spectrometers, the Orbitrap has not yet been investigated. Ten natural products (moxidectin, erythromycin, digoxin, rifampicin, amphotericin B, rapamycin, gramicidin S, cyclosporin A, vancomycin, and thiostrepton) ranging in molecular weight from 639 to 1663 Da were measured on an LTQ/Orbitrap mass spectrometer with resolving power settings of 7.5, 15, 30, 60, and 100 K. The difference in the observed profile isotope pattern compared with the theoretical calculation after peak shape calibration, denoted spectral error, was calculated using the program MassWorks (Cerno Bioscience, Danbury, CT, USA). Spectral errors were least at 7.5 K resolving power (≤3%) but exceeded 10% for some compounds at 100 K. The increasing spectral error observed at higher resolving power for compounds with complex fine structure might be explained by the phenomena of isotopic beat patterns as observed in FTICR. Several compounds with prominent doubly charged ions allowed comparison of spectral accuracies of singly-versus doubly-charged ions. When using spectral error to rank elemental compositions with formula constraints (C0–100H0–200N0–50O0–50Cl0–5S0–5) and a mass tolerance ≤2 parts-per-million, the correct formula was ranked first 35% of the time. However, spectral error considerations eliminated >99% of possible elemental formulas for compounds with molecular weight >900 Da.  相似文献   

12.
The relatively high background matrix in in vivo samples typically poses difficulties in drug metabolite identification, and causes repeated analytical runs on unit resolution liquid chromatography/mass spectrometry (LC/MS) systems before the completion of biotransformation characterization. Ballpark parameter settings for the LTQ‐Orbitrap are reported herein that enable complete in vivo metabolite identification within two HPLC/MS injections on the hybrid LTQ‐Orbitrap data collection system. By setting the FT survey full scan at 60K resolution to trigger five dependent LTQ MS2 scans, and proper parameters of Repeat Duration, Exclusion Duration and Repeat Count for the first run (exploratory), the Orbitrap achieved the optimal parallel data acquisition capability and collected maximum number of product ion scans. Biotransformation knowledge based prediction played the key role in exact mass ion extraction and multiple mass defect filtration when the initial data was processed. Meanwhile, product ion extraction and neutral loss extraction of the initial dependent data provided additional bonus in identifying metabolites. With updated parent mass list and the data‐dependent setting to let only the ions on the parent mass list trigger dependent scans, the second run (confirmatory) ensures that all precursor ions of identified metabolites trigger not only dependent product ion scans, but also at or close to the highest concentration of the eluted metabolite peaks. This workflow has been developed for metabolite identification of in vivo or ADME studies, of which the samples typically contain a high level of complex matrix. However, due to the proprietary nature of the in vivo studies, this workflow is presented herein with in vitro buspirone sample incubated with human liver microsomes (HLM). The major HLM‐mediated biotransformation on buspirone was identified as oxidation or hydroxylation since five mono‐ (+16 Da), seven di‐ (+32 Da) and at least three tri‐oxygenated (+48 Da) metabolites were identified. Besides the metabolites 1‐pyrimidinylpiperazine (1‐PP) and hydroxylated 1‐PP that formed by N‐dealkylation, a new metabolite M308 was identified as the result of a second N‐dealkylation of the pyrimidine unit. Two new metabolites containing the 8‐butyl‐8‐azaspiro[4,5]decane‐7,9‐dione partial structure, M240 and M254, were also identified that were formed apparently due to the first N‐dealkylation of the 1‐PP moiety. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
In this study, we benefit from the combination of liquid chromatography (LC)/time-of-flight (TOF) MS accurate mass measurements to generate elemental compositions of ions and LC/ion trap multiple MS (MSn) providing complementary structural information, which is useful for the elucidation of unknown organic compounds at trace levels in complex food extracts. We have applied this approach to investigate different citrus fruits extracts, and we have identified two post-harvest fungicides (imazalil and prochloraz), the main degradation product of imazalil ([M + H]+, m/z 257) and a non-previously reported prochloraz degradation product ([M + H]+, m/z 282). The database-mediated identification of the parent compounds was based on the generated elemental composition obtained from accurate mass measurements and additional qualitative information from the high resolution chlorine isotopic clusters of both the protonated molecules (imazalil, [M + H]+ 297.0556, <0.1 ppm error, 2-Cl; prochloraz, [M + H]+ 376.0381, 1.9 ppm error, 3-Cl) and their characteristic fragments ions (imazalil: m/z 255 and 159; prochloraz: m/z 308 and 266). The correlation between the structural information provided by ion trap MS/MS fragmentation pathways of the parent species and the TOF accurate mass elemental composition data of the degradation products were the key to elucidate the structures of the degradation products of both post-harvest fungicides. Finally, where standards were not available (prochloraz), further confirmation was obtained by synthesizing the proposed degradation product by acid hydrolysis of the parent standard and confirmation by LC/TOF-MS.  相似文献   

14.
The mass spectral properties of glucuronides of the 9- and 10-hydroxylated metabolites of RT-3003 (Vintoperol; (-)-1beta-ethyl-1alpha-hydroxymethyl-1,2,3,4,6,7, 12balpha-octahydroindolo[2,3-a]quinolizine), which were fractionated by high-performance liquid chromatography with fluorescence detection, were investigated using the positive ion electrospray ionization mode. These glucuronides showed predominantly the protonated molecular ion ([M + H](+) ion), and the [M + H](+) ion provided a characteristic product ion spectrum in which abundant ions were obtained at m/z 301, 160 and 142. The first ion, corresponding to the [aglycone + H](+) ion, was produced by neutral loss of the glucuronic acid moiety from the [M + H](+) ion. The product ion spectrum of the [M + H](+) ion of hydroxy-RT-3003 revealed a number of ions common to the glucuronide spectra, suggesting that other two ions observed most likely represent fragmentation of hydroxy-RT-3003. In turn, these glucuronides were positional isomers with respect to the binding site of glucuronic acid. The structures of the isomer pairs were discriminated by the presence of the ion of m/z 318 or 336 in the product ion spectrum. These ions were produced by fission of the C-ring, the same as for the formation of the ions of m/z 160 and 142, as were observed in the product ion spectrum from the [M + H](+) ion of hydroxy-RT-3003. For the formation of these ions, an unusual fragmentation process was proposed, and these ion structures were supported by evidence from the accurate mass measurement data. Additionally, in the sulfates of hydroxylated metabolites, a similar product ion corresponding to the ion of m/z 336 found in the phenolic glucuronides was observed, and was applied for identification of the sulfate metabolites.  相似文献   

15.
Reliable methods are needed for detection of allergenic milk proteins in complex food matrixes. The feasibility of an LC/high-resolution MS method for the analysis of milk proteins in a thermally processed model food (incurred cookies) and in white wine spiked, respectively, with milk powder and caseinate is described. Detection of milk proteins was based on the identification of unique peptides in the tryptic digests of cookie/wine extracts using an RP-HPLC separation coupled to an Exactive nonhybrid mass spectrometer using Orbitrap technology. The extremely high mass accuracy and resolution provided by the Orbitrap analyzer allowed a fast preliminary identification of four previously proposed peptide markers of caseins using only accurate values of the m/z of their ions. No interference was observed, despite the complexity of the analyzed matrixes. Moreover, the availability of a high- energy, collisionally activated dissociation cell integrated in the mass spectrometer enabled acquisition of peptide MS/MS-like spectra through post-source fragmentation. Confirmation of peptide marker identity could then be achieved by a comparison between experimental and predicted product ions. The described method shows the great potential of Orbitrap MS as a reliable technique in the field of protein allergen detection once the peptide markers are identified.  相似文献   

16.
This study offers a unique insight into the mass accuracy and resolving power requirements in MS/MS analyses of complex product ion spectra. In the examples presented here, accurate mass assignments were often difficult because of multiple isobaric interferences and centroid mass shifts. The question then arose whether the resolving power of a medium-resolution quadrupole time-of flight (QqTOF) is sufficient or high-resolution Fourier-transform ion cyclotron resonance (FT-ICR) is required for unambiguous assignments of elemental compositions. For the comparison, two paralytic shellfish poisons (PSP), saxitoxin (STX) and neosaxitoxin (NEO), with molecular weights of 299 and 315 g x mol(-1), respectively, were chosen because of the high peak density in their MS/MS spectra. The assessment of QqTOF collision-induced dissociation spectra and FT-ICR infrared multiphoton dissociation spectra revealed that several intrinsic dissociation pathways leading to isobaric fragment ions could not be resolved with the QqTOF instrument and required FT-ICR to distinguish very close mass differences. The second major source of interferences was M + 1 species originating from coactivated 13C12Cc-1 ion contributions of the protonated molecules of the PSPs. The problem in QqTOF MS results from internal mass calibration when the MH+ ions of analyte and mass calibrant are activated at the same time in the collision or trapping cell. Although FT-ICR MS readily resolved these interfering species, the QqTOF did not provide resolving power >20,000 (full width at half maximum) required to separate most isobaric species. We were able to develop a semi-internal QqTOF calibration technique that activated only the isolated 12C isotope species of the protonated molecules, thus reducing the M + 1 interferences significantly. In terms of overall automated elemental formulas assignment, FT-ICR MS achieved the first formula hit for 100% of the product ions, whereas the QqTOF MS hit rate was only 56 and 65% for STX and NEO product ions, respectively. External mass calibration from commercial FT-ICR and QqTOF instruments gave similar results.  相似文献   

17.
TM‐2 (13‐(N‐Boc‐3‐i‐butylisoserinoyl‐4,10‐β‐diacetoxy‐2‐α‐benzoyloxy‐5‐β‐20‐epoxy‐1,13‐α‐dihydroxy‐9‐oxo‐19‐norcyclopropa[g]tax‐11‐ene) is a novel semisynthetic taxane derivative. Our previous study suggested that TM‐2 is a promising antitumor analogue. In this paper, the metabolism of TM‐2 was investigated in rats following intravenous administration. Two different types of mass spectrometry—hybrid linear trap quadrupole orbitrap (LTQ‐Orbitrap) mass spectrometry and triple‐quadrupole tandem (QQQ) mass spectrometry—were employed to acquire structural information of TM‐2 metabolites. A total of 17 components were identified as the metabolites of TM‐2 in bile, feces, and urine samples. Accurate mass measurement using LC–LTQ‐Orbitrap‐MS was used to determine the accurate mass data and elemental composition of metabolites thereby confirming the proposed structures of the metabolites. The metabolites proposed were mainly oxidates of TM‐2, including methoxy, hydroxyl, dihydroxy, and trihydroxyl analogues. The major metabolic pathway of TM‐2 was the hydroxylation of the taxane ring or the lateral chain. These important metabolic data serve as a useful resource to support further research of TM‐2.  相似文献   

18.
Forsythoside A (FTA), the main active constituent isolated from Fructus Forsythiae, has various biological functions including anti‐oxidant, anti‐viral and anti‐microbial activities. However, while research on FTA has been mainly focused on the treatment of diseases on a material basis, FTA metabolites in vivo have not been comprehensively evaluated. Here, a rapid and sensitive method using a UHPLC‐LTQ‐Orbitrap mass spectrometer with multiple data processing techniques including high‐resolution extracted ion chromatograms, multiple mass defect filters and diagnostic product ions was developed for the screening and identification of FTA metabolites in rats. As the result, a total of 43 metabolites were identified in biological samples including 42 metabolites in urine, 22 metabolites in plasma and 15 metabolites in feces. These results demonstrated that FTA underwent a series of in vivo metabolic reactions including methylation, dimethylation, sulfation, glucuronidation, diglucuronidation, cysteine conjugation and their composite reactions. The research enhanced our understanding of FTA metabolism and built a foundation for further toxicity and safety studies.  相似文献   

19.
The structural elucidation of fourteen metabolites of CKD-732, formed in vitro with rat liver microsomes, was performed using high-performance liquid chromatography/electrospray ionization-tandem mass spectrometry (HPLC/ESI-MS/MS). To identify proposed structures of the metabolites, the product ion mass spectra of the protonated molecules ([M + H]+), the retention times on reversed-phase HPLC, and UV-Vis spectra were utilized. Characteristic product ions for the identification of CKD-732 metabolites were observed at m/z 231, 236, and 252. The fragment ions at m/z 236 and 252 indicated the unchanged form and the N-oxide of the dimethylaminoethoxycinnamoyl group, respectively. The ion at m/z 231 indicated the presence of the hydroxylated form of the fumagillol group. The N-oxide of CKD-732, which was detected at m/z 515 and eluted later than CKD-732 in the reversed-phase HPLC system, was measured as a major metabolite. Three cis-trans isomers were also found.  相似文献   

20.
We have investigated the potential and robustness of the off‐line coupling of polymerase chain reaction (PCR) with electrospray ionization mass spectrometry (ESI‐MS), for further applications in the screening of single‐nucleotide polymorphisms (SNPs). This was based on recently reported data demonstrating that anion‐exchange solid‐phase extraction was the most efficient technique for efficiently desalting PCR products, with a recovery of ~70%. Results showed that this purification approach efficiently removes almost all the chemicals commonly added to PCR buffers. ESI‐MS analysis of a model 114‐bp PCR product performed on the LTQ‐Orbitrap instrument demonstrated that detection limits in the nM range along with an average mass measurement uncertainty of 9.15 ± 7.11 ppm can be routinely obtained using an external calibration. The PCR/ESI‐MS platform was able to detect just a few copies of a targeted oligonucleotide. However, it was shown that if two PCR products are present in a mixture in a ratio higher than 10 to 1, the lower abundance one might not be reproducibly detected. Applications to SNPs demonstrated that an LTQ‐Orbitrap with a resolution of 30 000 (at m/z 400) easily identified a single (A ? G) switch, i.e. a 16 Da difference, in binary mixtures of ~ 35 kDa PCR products. Complementary experiments also showed that the combination of endonucleases and ESI‐MS could be used to confirm base composition and sequence, and thus to screen for unknown polymorphisms in specific sequences. For example, a single (T ? A) switch (9 Da mass difference) was successfully identified in a 114‐bp PCR product. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号