 共查询到20条相似文献,搜索用时 15 毫秒
1.
Neumann T  Ermert H 《Ultrasonics》2006,44(Z1):e1561-e1566
The visualization of ultrasonic wave fields in optically transparent liquids using the acousto-optic interaction is a well proven tool for the experimental investigation of wave propagation including wave field interaction effects with certain discontinuities and obstacles like reflection, refraction, and diffraction effects as well as for transducer testing and design. For high resolution visualization of wave fields including pulsed waveforms, pulsed light sources and sensitive optical imaging sensors with certain specifications are needed. In this paper the technical requirements of optical and electronic components for high resolution visualization of ultrasound wave fields will be presented. Also, specifications and operation results of a new designed, inexpensive Schlieren optical system will be presented, which is capable of pulsed wave field visualization in the MHz frequency range. The spatial resolution is high enough, not only for accurate beam shape and wave pattern visualization, but also for a gray-scaled display of wave amplitudes including amplitude zero crossings in ultrasound pulses. Consequently, ultrasonic wavelengths can be visualized quantitatively as well as wavelength changes of the ultrasound pulses while traveling through transparent media with different sound velocities. Results to be presented will include 2 MHz and 10 MHz experiments using single transducers as well as linear arrays of commercial medical scanners during their standard operation showing the system beamforming characteristics.  相似文献   

2.
For medical ultrasonic imaging and for nondestructive testing, the attenuation of pressure waves and the resulting shift in wave velocity are important features in commonly used transmission media such as biological tissue. An algorithm for the numerical evaluation of pressure field distributions generated by ultrasonic transducers is presented. The attenuation and dispersion of the sound transmission medium are taken into consideration. The sound fields are computed numerically for continuous wave as well as pulse excitation. The transducer has plane or gently curved geometry and is embedded in a plane rigid baffle. The numerically determined pressure fields are presented as 3D plots, as gray-scale images for a fixed time stamp (like a snapshot), or as isobars regarding the maximum values over time for each local point in the area under investigation. The algorithm described here can be utilized as a tool for design of ultrasound transducers, especially array antennas.  相似文献   

3.
The pressure fields of two different high intensity focused ultrasound (HIFU) transducers operated in burst mode were measured at acoustical power levels of 25 and 50 W (continuous wave equivalent) with three different hydrophones: A fiber-optic displacement sensor, a commercial HIFU needle hydrophone, and a prototype of a membrane hydrophone with a protective coating against cavitation effects. Additionally, the fields were modeled using a freely available simulations software package. The measured waveforms, the peak pressure profiles, as well as the spatial-peak temporal-average intensities from the different devices and from the modeling are compared and possible reasons for differences are discussed. The results clearly show that reliable pressure measurements in HIFU fields remain a difficult task concerning both the reliability of the measured values and the robustness of the sensors used: Only the fiber-optic hydrophone survived all four exposure regimes and the measured spatial-peak temporal-average intensities varied by a factor of up to 1.5 between the measurements and the modeling and between the measurements among themselves.  相似文献   

4.
This paper describes the application of an acousto-optic method to the measurement of airborne ultrasound. The method consists of a heterodyne interferometric probing of the pressure emitted by the transducer combined with a tomographic algorithm. The heterodyne interferometer measures the optical phase shift of the probe laser beam, proportional to the acoustic pressure integrated along the light path. A number of projections of the sound field, e.g. a set of ray integrals obtained along parallel paths, are made in moving the transducer to be tested. The main advantage of the method is its very high sensitivity in air (2 x 10(-4) Pa Hz-1/2), combined with a large bandwidth. Using the same principle as X-ray tomography the ultrasonic pressure in a plane perpendicular to the transducer axis can be reconstructed. Several ultrasonic fields emitted by wide-band home made electrostatic transducers, with operating frequencies between 200 and 700 kHz, have been measured. The sensitivities compared favorably with those of commercial airborne transducers.  相似文献   

5.
Electro-magnetic acoustic transducers (EMATs) are intended as non-contact and non-destructive ultrasound transducers for metallic material. The transmitted intensities from EMATS are modest, particularly at notable lift off distances. Some time ago a concept for a “coil only EMAT” was presented, without static magnetic field. In this contribution, such compact “coil only EMATs” with effective areas of 1–5 cm2 were driven to excessive power levels at MHz frequencies, using pulsed power technologies. RF induction currents of 10 kA and tens of Megawatts are applied. With increasing power the electroacoustic conversion efficiency also increases. The total effect is of second order or quadratic, therefore non-linear and progressive, and yields strong ultrasound signals up to kW/cm2 at MHz frequencies in the metal. Even at considerable lift off distances (cm) the ultrasound can be readily detected. Test materials are aluminum, ferromagnetic steel and stainless steel (non-ferromagnetic). Thereby, most metal types are represented. The technique is compared experimentally with other non-contact methods: laser pulse induced ultrasound and spark induced ultrasound, both damaging to the test object’s surface. At small lift off distances, the intensity from this EMAT concept clearly outperforms the laser pulses or heavy spark impacts.  相似文献   

6.
An equivalent source model is developed for setting boundary conditions on the parabolic diffraction equation in order to simulate ultrasound fields radiated by strongly focused medical transducers. The equivalent source is defined in a plane; corresponding boundary conditions for pressure amplitude, aperture, and focal distance are chosen so that the axial solution to the parabolic model in the focal region of the beam matches the solution to the full diffraction model (Rayleigh integral) for a spherically curved uniformly vibrating source. It is shown that the proposed approach to transferring the boundary condition from a spherical surface to a plane makes it possible to match the solutions over an interval of several diffraction maxima around the focus even for focused sources with F-numbers less than unity. This method can be used to accurately simulate nonlinear effects in the fields of strongly focused therapeutic transducers using the parabolic Khokhlov–Zabolotskaya equation.  相似文献   

7.
Stable arrays of cylindrical bubbles with diameters 3 and 4 μm were produced by trapping air in the pores of hydrophobic Nuclepore filters. These bubble arrays were irradiated by beams of cw and pulsed ultrasound at carrier frequencies near the resonance frequencies of the trapped bubbles. By examining the frequency spectrum of the field scattered by the arrays it was found that the bubbles may oscillate as non-linear stable cavities of long duration. Using short pulses, the bubbles remain stable up to excitation pressure amplitudes of several bars. Mechanisms for the eventual growth and decay of the bubbles are discussed in light of the observations.  相似文献   

8.
Two pilot pulsed power sources were developed for fundamental investigations and industrial demonstrations of treatment of conducting liquids. The developed heavy-duty power sources have an output voltage of 100 kV (rise time 10 ns, pulse duration 150 ns, pulse repetition rate maximum 1000 pps). A pulse energy of 0.5-3 J/pulse and an average pulse power of 1.5 kW have been achieved with an efficiency of about 80%. In addition, adequate electromagnetic compatibility is achieved between the high-voltage pulse sources and the surrounding equipment. Various applications, such as the use of pulsed electric fields (PEFs) or pulsed corona discharges for inactivation of microorganisms in liquids or air, have been tested in the laboratory. For PEF treatment, homogeneous electric fields in the liquid of up to 70 kV/cm at a pulse repetition rate of 10-400 pps could be achieved. The inactivation is found to be 85 kJ/L per log reduction for Pseudomonas fluorescens and 500 kJ/L per log reduction for spores of Bacillus cereus. Corona directly applied to the liquid is found to be more efficient than PEF. With direct corona we achieve 25 kJ/L per log reduction for both Gram positive and Gram negative bacteria. For air disinfection using our corona pulse source, the measured efficiencies are excellent: 2 J/L per log reduction  相似文献   

9.
Ultrasonic transducers with a central hole are increasingly in use in high-intensity therapeutic ultrasound and similar medical applications. The hole is intended for the addition of a diagnostic device. Some fundamental properties of the fields produced by such transducers are investigated here theoretically, based on a Rayleigh integral algorithm. The approach is restricted to those cases where the Rayleigh integral can be fully solved to yield closed-formula results that can be easily used by the reader. This means a concentration on points on the field axis which, on the other hand, is most important under the aspect of the safety of the patient (maximum amplitudes). Closed-form expressions describing the influence of the central hole on the acoustic pressure, on the particle velocity and on the time-averaged intensity are presented. The relation between the true intensity and the intensity expression derived from the square of the acoustic pressure is discussed in some detail, an aspect which is important in ultrasonic measurement practice where the local intensity value is mostly assessed based on the square of a hydrophone signal.  相似文献   

10.
Experimental studies of a plasma-filled X-band backward-wave oscillator (BWO) are presented. Depending on the background gas pressure, microwave frequency upshifts of up to 1 GHz appeared along with an enhancement by a factor of 7 in the total microwave power emission. The bandwidth of the microwave emission increased from ⩽0.5 GHz to 2 GHz when the BWO was working at the RF power enhancement pressure region. The RF power enhancement appeared over a much wider pressure range in a high beam current case (10-100 mT for 3 kA) than in a lower beam case (80-115 mT for 1.6 kA). The plasma-filled BWO has higher power output than the vacuum BWO over a broader region of magnetic guide field strength. Trivelpiece-Gould modes (T-G modes) are observed with frequencies up to the background plasma frequency in a plasma-filled BWO. Mode competition between the T-G modes and the X-band Tm01 mode prevailed when the background plasma density was below 6×1011 cm-3 . At a critical background plasma density of ≃8×1011 cm-3 power enhancement appeared in both X-band and the T-G modes. Power enhancement of the S-band in this mode collaboration region reached up to 8 dB. Electric fields measured by the Stark-effect method were as high as 34 kV/cm while the BWO power level was 80 MW. These electric fields lasted throughout the high-power microwave pulse  相似文献   

11.
In high intensity focused ultrasound (HIFU) applications, tissue may be thermally necrosed by heating, emulsified by cavitation, or, as was recently discovered, emulsified using repetitive millisecond boiling caused by shock wave heating. Here, this last approach was further investigated. Experiments were performed in transparent gels and ex vivo bovine heart tissue using 1, 2, and 3 MHz focused transducers and different pulsing schemes in which the pressure, duty factor, and pulse duration were varied. A previously developed derating procedure to determine in situ shock amplitudes and the time-to-boil was refined. Treatments were monitored using B-mode ultrasound. Both inertial cavitation and boiling were observed during exposures, but emulsification occurred only when shocks and boiling were present. Emulsified lesions without thermal denaturation were produced with shock amplitudes sufficient to induce boiling in less than 20 ms, duty factors of less than 0.02, and pulse lengths shorter than 30 ms. Higher duty factors or longer pulses produced varying degrees of thermal denaturation combined with mechanical emulsification. Larger lesions were obtained using lower ultrasound frequencies. The results show that shock wave heating and millisecond boiling is an effective and reliable way to emulsify tissue while monitoring the treatment with ultrasound.  相似文献   

12.
The Shubnikov-de Haas (SdH) oscillation spectra of the -(BEDT-TTF)4(NH4)[ Cr(C2O4)3] .DMF organic metal have been studied in pulsed magnetic fields of up to either 36 T at ambient pressure or 50 T under hydrostatic pressures of up to 1 GPa. The ambient pressure SdH oscillation spectra can be accounted for by up to six fundamental frequencies which points to a rather complex Fermi surface (FS). A noticeable pressure-induced modification of the FS topology is evidenced since the number of frequencies observed in the spectra progressively decreases as the pressure increases. Above 0.8 GPa, only three compensated orbits are observed, as it is the case for several other isostructural salts of the same family at ambient pressure. Contrary to other organic metals, of which the FS can be regarded as a network of orbits, no frequency combinations are observed for the studied salt, likely due to high magnetic breakdown gap values or (and) high disorder level evidenced by Dingle temperatures as large as ≃7 K.  相似文献   

13.
Generating and detecting ultrasound is a standard method of nondestructive evaluation of materials. Pulsed lasers are used to generate ultrasound remotely in situations that prohibit the use of contact transducers. The scanning rate is limited by the repetition rates of the pulsed lasers, ranging between 10 and 100 Hz for lasers with sufficient pulse widths and energies. Alternately, a high-power continuous-wave laser can be scanned across the surface, creating an ultrasonic wavefront. Since generation is continuous, the scanning rate can be as much as 4 orders of magnitude higher than with pulsed lasers. This paper introduces the concept, comparing the theoretical scanning speed with generation by pulsed laser.  相似文献   

14.
Knowing the low-frequency response of hydrophones, down to 100 kHz at least, is important for accurate biomedical ultrasound measurements. However, current international standards do not extend below 500 kHz. Furthermore, commercial hydrophone sources typically do not supply sensitivity data below 1-2 MHz. Therefore, to help identify and validate practical calibration methods below 2 MHz, the authors have extended their previous individual efforts in an interlaboratory evaluation of sensitivity calibration using the swept-frequency technique, time delay spectrometry (TDS). Calibrations were performed for needle and membrane PVDF hydrophones using each laboratory's TDS system. Each site employed the same purpose-built broadband source transducers, comprising both plano-concave and biconcave 1-3 piezocomposite elements 4 cm in diameter, with maximum and minimum thicknesses of approximately 1.5 and 0.1 cm. Agreement between laboratories was within the estimated measurement precision of +/-0.6 dB. The results demonstrated that a TDS system employing such transducers constitutes a viable method for hydrophone calibrations in this frequency range.  相似文献   

15.
There has been interest for a number of years in the possibility of separating blood into cells and plasma by methods other than centrifugation, so that the plasma can be analysed on-line. Cells in whole blood normally occupy about 45% of the suspension volume. It has been shown with a number of different cell types, such as yeast and bacteria, that for concentrations of this order the cells are not as efficiently harvested by ultrasound as those for lower concentrations. In this study, removal of cells from 3-4 ml whole blood volumes has been examined in ultrasonic standing wave fields from tubular transducers driven at a frequency of 1.6 MHz. Samples of whole human blood (n = 11) from two volunteers have been processed by three tubular transducers where high levels of cell removal, 99.7% on average, have been demonstrated with high reproducibility between samples as well as for different transducers.  相似文献   

16.
To address the challenges associated with measuring the ultrasonic power from high-intensity focused ultrasound transducers via radiation force, a technique based on pulsed measurements was developed and analyzed. Two focused ultrasound transducers were characterized in terms of an effective duty factor, which was then used to calculate the power during the pulse at high applied power levels. Two absorbing target designs were used, and both gave comparable results and displayed no damage and minimal temperature rise if placed near the transducer and away from the focus. The method yielded reproducible results up to the maximum pulse power generated of approximately 230 W, thus allowing the radiated power to be calibrated in terms of the peak-to-peak voltage applied to the transducer.  相似文献   

17.
A generalized impulse response formulation to evaluate the harmonic pressure field of ultrasonic planar vibrators having axisymmetric nonuniform surface velocity distributions is presented. The harmonic pressure is expressed as a Fourier transform of a generalized impulse response which is a function of the spatially nonuniform velocity of the vibrator. A backward projection method is then developed to reconstruct the normal surface velocity of axisymmetric vibrators from harmonic field pressures using an angular spectrum or Hankel transform formulation. The numerical accuracy of the backward projection technique is evaluated using the impulse response formulation to evaluate the pressure fields for several velocity distributions on disk vibrators. Experiments were performed to reconstruct the velocity distributions over the surface of a uniformly driven piezoelectric ceramic disk and ceramic ring using farfield measurements of the complex pressure. The experimental results were in good agreement with theoretical results based on the electrode patterns of the transducers.  相似文献   

18.
New techniques of forming high intensity focused ultrasound (HIFU) fields using dynamic focusing and harmonic multifrequency excitation are developed for ultrasonic diagnostics and therapy. New designs of HIFU transducers based on high-performance composite materials are developed and studied. Finite-element and finite-difference simulations of HIFU transducers and processes of ultrasonic wave propagation in biological tissues are performed. The parameters of piezoceramic materials, piezoelements, and the acoustic fields of focusing ultrasonic transducers are measured. Experiments are performed on biological tissues ex vivo that confirm the efficiency, selectivity, and safety of the developed HIFU transducers and techniques of forming acoustic fields.  相似文献   

19.
The present paper proposes a new characterization technique for air-coupled ultrasound probes. The technique is based on a shock tube to generate a controlled pressure wave to calibrate transducers within their operating frequency range. The aim is to generate a high frequency pressure wave (at least up to 200 kHz) with the low energy levels typical of commonly used air-coupled ultrasound probes. A dedicated shock-tube has been designed and tested to assess calibration performances. The sensor transfer function has been measured by using a pressure transducer as reference.  相似文献   

20.
Acoustic fields of powerful ultrasound sources with Gaussian spatial apodization and initial excitation in the form of a periodic wave or single pulse are examined based on the numerical solution of the Khokhlov-Zabolotskaya-Kuznetsov equation. The influence of nonlinear effects on the spatial structure of focused beams, as well as on the limiting values of the acoustic field parameters is compared. It is demonstrated that pressure saturation in periodic fields is mainly due to the effect of nonlinear absorption at a shock front, while in pulsed fields is due to the effect of nonlinear refraction. The limiting attainable values for the peak positive pressure in periodic fields turned out to be higher than the analogous values in pulsed acoustic fields. The total energy in a beam of periodic waves decreases with the distance from the source faster than in the case of a pulsed field, but it becomes concentrated within much smaller spatial region in the vicinity of the focus. These special features of nonlinear effect manifestation provide an opportunity to use pulsed beams for more efficient delivery of wave energy to the focus and to use periodic beams for attaining higher values of pressure in the focal region.  相似文献   