1.
《Microchemical Journal》2011,97(2):337-343
An analytical protocol combining a headspace technique with gas chromatography and detection by photoionization detector and flame ionization detector (HS-GC-PID-FID) was developed. This procedure was used to measure volatile organic compounds (VOCs) in environmental aqueous matrices and was applied in determination of VOCs on the coast of Fortaleza, Brazil. At optimum operating conditions, analytical figures of merit such as linearity (R ranged from 0.9983 to 0.9993), repeatability (5.62 to 9.63% and 0.02 to 0.19% for the quantitative and qualitative analyses, respectively), detection limits (0.22 to 7.48 μg L1) and sensibility were estimated. This protocol favors a fast sampling/sample preparation (in situ), minimizes the use of laboratory material, eliminates the matrix effect from environmental samples, and can be applied to river, estuarine and oceanic waters. The advantage of detectors in series is that a low sensitivity in detection in one is compensated by the other. Toluene was the most abundant VOC in the studied area, with an average concentration of 1.63 μg L1. It was followed by o-xylene (1.15 μg L1), trichloroethene (1.08 μg L1), benzene (0.86 μg L1), ethylbenzene (0.74 μg L1), carbon tetrachloride (0.55 μg L1), m/p-xylene (0.48 μg L1) and tetrachloroethene (0.46 μg L1), compounds which are very commonly detected in urban runoff from most cities. The results of the VOC distribution showed that port activity was not the main source of VOCs along the Fortaleza Coast, but that the contribution from urban runoff seemed more significant.  相似文献   

2.
Poly (neutral red) nanowires (PNRNWs) have been synthesized for the first time by the method of cyclic voltammetric electrodeposition using porous anodic aluminum oxide (AAO) template and were examined by scanning electron microscopy (SEM) and transmission electron microscope (TEM). Moreover, horseradish peroxidase (HRP) was encapsulated in situ in PNRNWs (denoted as PNRNWs–HRP) by electrochemical copolymerization for potential biosensor applications. The PNRNWs showed excellent efficiency of electron transfer between the HRP and the glassy carbon (GC) electrode for the reduction of H2O2 and the PNRNWs–HRP modified GC electrode showed to be excellent amperometric sensors for H2O2 at −0.1 V with a linear response range of 1 μM to 8 mM with a correlation coefficient of 0.996. The detection limit (S/N = 3) and the response time were determined to be 1 μM and <5 s and the high sensitivity is up to 318 μA mM−1 cm−2.  相似文献   

3.
This work reports on a novel chitosan–hematite nanotubes composite film on a gold foil by a simple one-step electrodeposition method. The hybrid chitosan–hematite nanotubes (Chi–HeNTs) film exhibits strong electrocatalytic reduction activity for H2O2. Interestingly, two electrocatalytic reduction peaks are observed at −0.24 and −0.56 V (vs SCE), respectively, one controlled by surface wave and the other controlled by diffusion process. The Chi–HeNTs/Au electrode shows a linear response to H2O2 concentration ranging from 1 × 10−6 to 1.6 × 10−5 mol L−1 with a detection limit of 5 × 10−8 mol L−1 and a sensitivity as high as 1859 μA μM−1 cm−2.  相似文献   

4.
Using porous cuprous oxide (Cu2O) microcubes, a simple non-enzymatic amperometric sensor for the detection of H2O2 and glucose has been fabricated. Cyclic voltammetry (CV) revealed that porous Cu2O microcubes exhibited a direct electrocatalytic activity for the reduction of H2O2 in phosphate buffer solution and the oxidation of glucose in an alkaline medium. The non-enzymatic amperometric sensor used in the detection of H2O2 with detection limit of 1.5 × 10?6 M over wide linear detection ranges up to 1.5 mM and with a high sensitivity of 50.6 μA/mM. This non-enzymatic voltammetric sensor was further utilized in detection of glucose with a detection limit of 8.0 × 10?7 M, a linear detection range up to 500 μM and with a sensitivity of ?70.8 μA/mM.  相似文献   

5.
By grafting with poly(amidoamine) (PAMAM) dendrimer, novel carbon nanotube (CNT) nano-composites have been successfully prepared. The novel functionalized matrix with plenty amino groups circumvents the troublesome solubility problem of CNTs in solvents, especially in water, greatly expanding the scope of the application of carbon nanotubes. The GOx and HRP immobilized CNT-PAMAM based on the functional CNTs was synthesized. The bi-enzymatic CNT-PAMAM nano-composites are highly dispersible in water and show very promising applications in the fabrication of mediator-free bi-enzymatic biosensors for sensitive detection of glucose. The cooperation of nano-composite between CNT and high dense GOx and HRP results in very high sensitivity to glucose with a current response of 2200 nA mM−1 and fast response (∼1 s). The modified electrode exhibits a wide linear response range for glucose from 4.0 μM to 1.2 mM (R = 0.9971, N = 15), with a detection limit of 2.5 μM. The negative electrode potential of −0.34 V is favorable for glucose detection in real samples without interference caused by other biomolecules.  相似文献   

6.
In this work, a novel amperometric biosensor based on carbon nanoplatelets derived from ground cherry (Physalis peruviana) husks (GCHs-CNPTs) is reported for the sensitive and selective detection of ascorbic acid (AA). The structure of the nanoplatelets, the oxygen-containing groups and edge-plane-like defective sites (EPDSs) on the GCHs-CNPTs were characterized by scanning electron microscopy, X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy and Fourier transform infrared spectroscopy. The presence of GCHs-CNPTs with a high density of EPDSs effectively enhances the electron transfer between AA and the glassy carbon electrode (GCE), and thus induces a substantial decrease in the overvoltage for AA oxidation compared with both a bare GCE and a GCE modified with carbon nanotubes (CNTs/GCE). In particular, an amperometric biosensor based on GCHs-CNPTs exhibited a wider linear range (0.01–3.57 mM), higher sensitivity (208.63 μA mM 1 cm 2), a lower detection limit (1.09 μM, S/N = 3) and better resistance to fouling for AA determination compared to a CNTs/GCE. The great potential of the GCHs-CNPTs/GCE for practical and reliable AA analysis was demonstrated by the successful determination of AA in samples taken from a medical injection dose and a soft drink.  相似文献   

7.
We report here a wall-jet electrogenerated iodine approach for sensitive detection of arsenite (AsIII) by using a disposable screen-printed ring disk carbon electrode. Iodide (I) is first oxidized to iodine (I2) at the disk electrode; the electrogenerated I2 can be effectively reduced back to I in the presence of AsIII. The inhibited reduction current of I2 to I can thus be monitored at the ring electrode and used for AsIII analysis. Various factors influencing the flow injection analysis (FIA) of AsIII were thoroughly investigated in this study. Under the optimized conditions, a linear calibration plot up to 10 μM with a detection limit (S/N = 3) of 70 nM was obtained by using 50 μM KI as the mobile phase in FIA. Practical utility of the proposed method was demonstrated to detect AsIII in “Blackfoot” disease endemic village groundwater from southwestern coast area of Taiwan (Pei-Men).  相似文献   

8.
A novel three-dimensional (3D) electrochemical sensor was developed for highly sensitive detection of hydrogen peroxide (H2O2). Monolithic and macroporous graphene foam grown by chemical vapor deposition (CVD) served as the electrode scaffold. Using in-situ polymerized polydopamine as the linker, the 3D electrode was functionalized with thionine molecules which can efficiently mediate the reduction of H2O2 at close proximity to the electrode surface. Such stable non-enzymatic sensor is able to detect H2O2 with a wide linear range (0.4 to 660 μM), high sensitivity (169.7 μA mM 1), low detection limit (80 nM), and fast response (reaching 95% of the steady current within 3 s). Furthermore, this sensor was used for real-time detection of dynamic release of H2O2 from live cancer cells in response to a pro-inflammatory stimulant.  相似文献   

9.
The present work describes the development of a new strategy to photoelectrochemical detection of L-Dopa at low potential based on oxygen reduction on TiO2 sensitized with iron phthalocyanine (FePc/TiO2). The FePc/TiO2 composite shows a photocurrent 10-fold higher than that of pure TiO2 nanoparticles and it was 4-fold higher than that of FePc exploiting visible light. The band gaps of pure TiO2 nanoparticles, FePc and FePc/TiO2, calculated according to the Kubelka–Munk equation, were 3.22 eV, 3.11 eV and 2.82 eV, respectively. The FePc/TiO2 composite showed a low charge transfer resistance in comparison to the photoelectrode modified with FePc or TiO2. Under optimized conditions, the photoelectrochemical sensor shows a linear response range from 20 up to 190 μmol L 1 with a sensitivity of 31.8 μA L mmol 1 and limit of detection of 1.5 μmol L 1 for the detection of L-Dopa.  相似文献   

10.
A glassy carbon electrode (GCE) modified with internal-electrolysis deposited gold nanoparticles (AuNPsied) was applied to sensitively and selectively detect As(III) by anodic stripping linear sweep voltammetry (ASLSV). The AuNPsied/GCE was prepared based on the redox replacement reaction between a supporting-electrolyte-free aqueous HAuCl4 and a copper sheet in saturated KCl separated by a salt bridge. Under optimum conditions (0.5 M aqueous H2SO4, 300-s preconcentration at − 0.4 V), the ASLSV peak current for the As(0)–As(III) oxidation responded linearly to As(III) concentration from 0.02 to 3 μM with a limit of detection (LOD) of 0.9 nM (0.07 μg L 1) (S/N = 3), while that for the As(III)–As(V) oxidation was linear with As(III) concentration from 0.02 to 1 μM with a LOD of 4 nM (0.3 μg L 1) (S/N = 3). An appropriate high-scan-rate for ASLSV can enhance both the sensitivity and signal-to-noise ratio. This method was applied for analyses of As(III) in real water samples.  相似文献   

11.
The advantages of using membrane micropumps rather than peristaltic pumps to introduce both sample and reagent solutions for hydride generation atomic fluorescence spectrometry are discussed. Arsenic was used as a test analyte to check the performance of the proposed manifold. Sample and reagent consumption was reduced 8–9 fold compared with continuous mode measurements made with peristaltic pumps, with no deterioration in sensitivity. The calibration graph was linear in the 0.05 to 2.5 μg l 1 As range using peak area as the analytical signal and maximum gain in the detector setting. A limit of detection (3σ) of 0.02 μg l 1 and relative standard deviation values close to 2% for 10 independent measurements of a 1 μg l 1 As solution were obtained. The sampling frequency increased from 45 to 102 h 1 with the subsequent saving in carrier gas used and reduction in wastes generated. The instrumental modification, which could be used for other elements currently determined by atomic fluorescence spectrometry, will permit hydride generators of more reduced dimensions to be constructed.  相似文献   

12.
A new PVC membrane based strontium(II) ion-selective electrode has been constructed using acetophenone semicarbazone as a neutral carrier. The sensor exhibits a Nerstian response for strontium(II) ion over a wide concentration range 1.0 × 10−2–1.0 × 10−7 M with the slope of 29.4 mV/per decade. The limit of detection was 2.7 × 10−8 M. It was relatively fast response time (<10 s for concentration ⩾1.0 × 10−3 and <15 s for concentration of ⩾1.0 × 10−6 M) and can be used for 8 months without any considerable divergence in potentials. The proposed sensor revealed relatively good selectivity and high sensitivity for strontium(II) over a mono, di, trivalent cation and can be used in a pH range of 2.5–10.5. It was also successfully used as an indicator electrode in potentiometer titration and in the analysis of concentration in various real samples.  相似文献   

13.
This communication describes the electron transport behaviour of basal plane pyrolytic graphite electrodes (BPPGEs) modified with nickel powder (BPPGE-Ni), single-walled carbon nanotube (BPPGE-SWCNT) and BPPGE-Ni decorated with SWCNT via drop-dry method (BPPGE-Ni-SWCNT). The BPPGE-Ni gave enhanced Faradaic response for the redox probe (Ferricyanide/Ferrocyanide species) and also displayed enhanced electrocatalytic behaviour towards the detection of degradation products of V-type nerve agents, dimethylaminoethanethiol (DMAET) and diethylaminoethanethiol (DEAET) with high sensitivity (∼23 × 10−3 AM−1) and low detection limits (4.0–9.0 μM range). When compared to the notable electrodes and detection protocols reported in the literature, BPPGE-Ni exhibits more promising features required for a simple, highly sensitive, fast and less expensive electrode for the detection of these V-type nerve agents in aqueous solution. The efficient response of the BPPGE-Ni is attributed to the high microscopic surface area of the nickel powder. The poor response of the BPPGE-Ni-SWCNT suggests that nickel impurity in the SWCNT did not show any detectable impact on its electron transfer kinetics.  相似文献   

14.
Analytical performances of metal coated slotted quartz tube flame atomic absorption spectrometry (SQT-FAAS) and slotted quartz tube in situ atom trapping flame atomic absorption spectrometry (SQT-AT-FAAS) systems were evaluated for determination of Bi. Non-volatile elements such as Mo, Zr, W and Ta were tried as coating materials. It was observed that W-coated SQT gave the best sensitivity for the determination of Bi for SQT-FAAS and SQT-AT-FAAS. The parameters for W-coated SQT-FAAS and W-coated SQT-AT-FAAS were optimized. Sensitivity of FAAS for Bi was improved as 4.0 fold by W-coated SQT-FAAS while 613 fold enhancement in sensitivity was achieved by W-coated SQT-AT-FAAS using 5.0 min trapping with respect to conventional FAAS. MIBK was selected as organic solvent for the re-atomization of Bi from the trapping surface. Limit of detection values for W-coated SQT-FAAS and W-coated SQT-AT-FAAS was obtained as 0.14 μg mL 1 and 0.51 ng mL 1, respectively. Linear calibration plot was obtained in the range of 2.5–25.0 ng mL 1 for W-coated SQT-AT-FAAS. Accuracy of the W-coated SQT-AT-FAAS system was checked by analyzing a standard reference material, NIST 1643e.  相似文献   

15.
A novel in-situ prepared copper film electrode (CuFE) for anodic stripping voltammetric measurement of trace levels of Hg(II) and Pb(II) is presented. The optimal electroanalytical performance of the CuFE was achieved in electrolyte solution comprising 0.1 M HCl and 0.4 M NaCl. The CuFE exhibited excellent operation in the presence of dissolved oxygen with calculated LoD of 0.1 μg L 1 Hg(II) and 0.06 μg L 1 Pb(II) in combination with 300 s accumulation time, repeatability with RSD of 4.5% for Hg(II) and 0.9% for Pb(II) (n = 12), and favourable linear response in the examined concentration range of 10–100 μg L 1 (R2 = 0.997) for Hg and 5–70 μg L 1 (R2 = 0.999) for Pb after 120 s accumulation. The electrode enabled also simultaneous detection of both investigated metal ions and revealed promising electroanalytical characteristics similar to or in certain cases surpassing those of commonly used gold electrodes.  相似文献   

16.
We demonstrate the application of differential pulse voltammetry (DPV) for the electrochemical detection of perchloroethylene (PCE) on an unmodified glassy carbon electrode surface. Detection sensitivity was substantially improved using DPV, in which dechlorination was denoted by a cathodic peak observed at approximately − 0.6 V (vs Ag/AgCl). Peak current intensity was found to correlate linearly with concentration over a tested range of 0 to 10 μM. The utility of this technique was subsequently evaluated for PCE-spiked environmental samples containing either Methylobacterium adhaesivum (1 × 106 cells/mL) or creek water (10% v/v). In all environmental samples, a linear dynamic range was also observed from approximately 0 to 10 μM. The limit of detection was determined to be 0.3 μM in blank buffer, 0.4 μM in bacteria-containing samples and 1.2 μM in creek water samples.  相似文献   

17.
Electrode fouling is a major challenge for the long term use of sensors in real samples as it leads to the decay of the electroanalytical signal and is often caused by the formation of an inhibiting layer formed by biomolecules. We demonstrate here that ordered and vertically aligned mesoporous silica generated at the surface of an indium tin oxide electrode by electrochemically assisted self-assembly act as a molecular sieve and a protective layer for the electrode surface. They indeed prevent the adsorption of size excluded large undesired molecules (e.g. haemoglobin) while allowing the detection of small redox active molecules likely to reach the electrode surface through the film (e.g. propranolol) with almost no loss of sensitivity. At a bare electrode, the oxidation of propranolol is completely inhibited in the presence of 5 μM haemoglobin. At a modified electrode, the sensitivity for propranolol in the absence of haemoglobin is (72.8 ± 2.9) mA mol 1 (R2 = 0.992, N = 7) and it remains similar in the presence of 5 μM haemoglobin with a value of (67.4 ± 7.2) mA mol 1 (R2 = 0.992, N = 7).  相似文献   

18.
New biocomposite materials, based on the incorporation of DNA doped p-aminobenzensulfonic acid, was fabricated by electrochemical method. A carbon fiber microelectrode modified by this thin film was fabricated for selective determination of uric acid (UA) in the presence of a larger amount of ascorbic acid (AA). It was found that the voltammetric oxidation peak separation between UA and AA is about 260 mV at the modified electrode. A linear response of the peak current versus the concentration was found in the range of 8 × 10−7–6 × 10−4 M with correlation coefficient of 0.9991 and the detection limit was 5 × 10−7 M (s/n = 3) at the 5 × 10−4 M AA. The presence of high concentration AA did not interference the determination. The electropolymerized film was characterized by SEM techniques. The modified electrode shows good sensitivity, selectivity and stability.  相似文献   

19.
A novel electrochemical method for measuring transglutaminase activity was reported. This approach was based on the patterning of gold electrodes with a mixed self-assembled monolayer of perthiolated β-cyclodextrin and 1-octanethiol. The proper functionalization of β-cyclodextrin with primary amino groups allowed it to act as amino-donor substrates for transglutaminase and molecular nanopores for the enzyme-controlled diffusion of Fe(CN)63 −/4  to the electrode surface. Voltamperometric measurements allowed detection of transglutaminase in the range of 1.9–37 mU/mL with a sensitivity of 1.42 nA μL U 1 s 1.  相似文献   

20.
A new noncovalent approach for the dissolution of MWNTs in water by azocarmine B (ACB) is reported. Through a simple electro-polymerization procedure, a novel electrochemical NO sensor based on water-soluble MWNTs and polyazocarmine B (PACB) nanofilm electrode was prepared, which showed excellent electrocatalytic activity towards the oxidation of nitric oxide (NO). The oxidation current linearly increased with the nitric oxide concentration in the range of 2.2 × 10−7–1.2 × 10−4 mol L−1 with a low detection limit of 2.8 × 10−8 mol L−1. The sensor has the merit of good stability, reproducibility, high sensitivity and selectivity, and it can be used to monitor NO released from rat liver cells effectively.  相似文献   