首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 781 毫秒
1.
The incorporation of stable isotopes improves the assessment of glucose metabolism and, with some researchers using two tracers, (2)H-glucose assessed by gas chromatography/mass spectrometry (GC/MS) and (13)C-glucose by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS), a common derivative for both is advantageous. The most commonly used derivatives for GC/MS are inappropriate for GC/C/IRMS as additional functional groups dilute the label. We therefore considered the suitability of six derivatives for both GC/MS and GC/C/IRMS. Glucose alkylboronates were prepared by adding the appropriate alkylboronic acid (butyl- or methylboronic acid) in pyridine to desiccated glucose. The derivatisation was completed by reacting this with either (a) acetic anhydride or trifluoroacetic anhydride (acetate derivatives) or (b) bis(trimethylsilyl)trifluoroacetamide BSTFA (TMS derivatives). All six derivatives were assessed using GC/MS and (13)C GC/C/IRMS.Neither TMS derivative exhibited any signal intensity in the molecular ion, although a M-15 ion showed good agreement between experimental and theoretical data and, whilst still low in intensity, could be suitable for isotope work. Similarly, none of the acetate derivatives showed any intensity at the molecular ion although three key fragmentation series were identified. The most attractive sequence, initiated by the loss of 1,2 cyclic boronate, resulted in the main fragment ion of interest, m/z 240, corresponding to the fluorinated methylboronate derivate. Minimal carbon and hydrogen atoms are added to this derivative making it an excellent choice for stable isotope work, while proving suitable for analysis by both GC/MS and GC/C/IRMS.  相似文献   

2.
The confirmation by GC/C/IRMS of the exogenous origin of pseudo-endogenous steroids from human urine samples requires extracts of adequate purity. A strategy based on HPLC sample purification prior to the GC/C/IRMS analysis of human urinary endogenous androgens (i.e. testosterone, androsterone and/or androstenediols), is presented. A method without any additional derivatization step is proposed, allowing to simplify the urine pretreatment procedure, leading to extracts free of interferences permitting precise and accurate IRMS analysis, without the need of correcting the measured delta values for the contribution of the derivatizing agent. The HPLC extracts were adequately combined to both reduce the number of GC/C/IRMS runs and to have appropriate endogenous reference compounds (ERC; i.e. pregnanediol, 11-keto-etiocholanolone) on each GC–IRMS run. The purity of the extracts was assessed by their parallel analysis by gas chromatography coupled to mass spectrometry, with GC conditions identical to those of the GC/C/IRMS assay. The method has been validated according to ISO17025 requirements (within assay precision below 0.3 ‰ 13C delta units and between assay precision below 0.6 ‰ 13C delta units for most of the compounds investigated) fulfilling the World Anti-Doping Agency requirements.  相似文献   

3.
A detailed procedure for the analysis of exogenous hydrocortisone and cortisone in urine by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) is proposed. As urinary levels of hydrocortisone are rather low for GC/C/IRMS analysis, the focus is on the main corticosteroid metabolites, tetrahydrocortisone (THE) and tetrahydrocortisol (THF). Following different solid phase extraction purifications, THE and THF are oxidized to 5beta-androstanetrione before analysis by GC/C/IRMS. Significant differences in delta(13)C per thousand values of synthetic natural corticosteroids and endogenous human corticosteroids have been observed. Therefore, a positive criterion, to detect exogenous administration of synthetic corticosteroids in anti-doping control, is proposed.  相似文献   

4.
Since GHB (gamma-hydroxybutyric acid) is naturally produced in the human body, clinical and forensic toxicologists must be able to discriminate between endogenous levels and a concentration resulting from exposure. To suggest an alternative to the use of interpretative concentration cut-offs, the detection of exogenous GHB in urine specimens was investigated by means of gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). GHB was isolated from urinary matrix by successive purification on Oasis MCX and Bond Elute SAX solid-phase extraction (SPE) cartridges prior to high-performance liquid chromatography (HPLC) fractioning using an Atlantis dC18 column eluted with a mixture of formic acid and methanol. Subsequent intramolecular esterification of GHB leading to the formation of gamma-butyrolactone (GBL) was carried out to avoid introduction of additional carbon atoms for carbon isotopic ratio analysis. A precision of 0.3 per thousand was determined using this IRMS method for samples at GHB concentrations of 10 mg/L. The (13)C/(12)C ratios of GHB in samples of subjects exposed to the drug ranged from -32.1 to -42.1 per thousand, whereas the results obtained for samples containing GHB of endogenous origin at concentration levels less than 10 mg/L were in the range -23.5 to -27.0 per thousand. Therefore, these preliminary results show that a possible discrimination between endogenous and exogenous GHB can be made using carbon isotopic ratio analyses.  相似文献   

5.
The use of stable isotope labelled glucose provides insight into glucose metabolism. The 13C‐isotopic enrichment of glucose is usually measured by gas chromatography/mass spectrometry (GC/MS) or gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). However, in both techniques the samples must be derivatized prior to analysis, which makes sample preparation more labour‐intensive and increases the uncertainty of the measured isotopic composition. A novel method for the determination of isotopic enrichment of glucose in human plasma using liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) has been developed. Using this technique, for which hardly any sample preparation is needed, we showed that both the enrichment and the concentration could be measured with very high precision using only 20 µL of plasma. In addition, a comparison with GC/MS and GC/IRMS showed that the best performance was achieved with the LC/IRMS method making it the method of choice for the measurement of 13C‐isotopic enrichment in plasma samples. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
The effects of the gas chromatography flow rate on the determination of the deuterium/hydrogen (D/H) ratios of natural gas utilising gas chromatography/high-temperature conversion/isotope ratio mass spectrometry (GC/TC/IRMS) have been evaluated. In general, the measured deltaD values of methane, ethane and propane decrease with increase in column flow rate. When the column flow rate is 1 mL/min or higher, which is commonly used for the determination of D/H ratios of natural gas, the organic H in gas compounds may not be completely converted into hydrogen gas. Based on the results of experiments conducted on a GC column with an i.d. of 0.32 mm, a GC flow rate of 0.6 mL/min is proposed for determining the D/H ratios of natural gas by GC/TC/IRMS. Although this value may be dependent on the instrument conditions used in this work, we believe that correct deltaD values of organic compounds with a few carbon atoms are obtained only when relatively low GC flow rates are used for D/H analysis by GC/TC/IRMS. Moreover, as the presence of trace water could significantly affect the determination of D/H ratios, a newly designed inlet liner was used to remove trace water contained in some gas samples.  相似文献   

7.
Compound-specific stable carbon isotope analysis of amino acids by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) is a highly selective and sensitive method for probing the biosynthetic/diagenetic pathways, pool size and turnover rates of proteins, previously intractable to bulk isotope analyses. However, amino acids are polyfunctional, non-volatile compounds which require derivatisation prior to GC analysis. While a wide range of derivatives exist for the GC analysis of amino acids only a handful have been utilised for their GC/C/IRMS analysis. Significantly, none of those derivatives currently employed appear completely satisfactory and a thorough assessment of their relative utility is lacking. Seven derivatives (three previously reported and four novel) for obtaining delta(13)C values of amino acids via GC/C/IRMS analysis were compared. More specifically, standard mixtures of 15 protein amino acids were converted into N-acetylmethyl (NACME) esters, N-acetyl n-propyl (NANP) esters, N-acetyl i-propyl (NAIP) esters, N-trifluoroacetyl-i-propyl (TFA-IP) esters, N-pivaloyl methyl (NPME) esters, N-pivaloyl n-propyl (NPNP) esters and N-pivaloyl i-propyl (NPIP) esters. Each derivative was assessed with respect to its applicability to carbon isotope determinations of all the common alpha-amino acids, reaction yield, chromatographic resolution, stability, analyte-to-derivative carbon ratio, kinetic isotope effects and errors associated with their carbon isotope determinations. The NACME derivative was concluded to be the preferred derivative mainly due to the highest analyte-to-derivative carbon ratio being achieved, resulting in the lowest analytical errors for amino acid delta(13)C value determinations, ranging from +/-0.6 per thousand for phenylalanine, leucine and isoleucine to +/-1.1 per thousand for serine and glycine.  相似文献   

8.
A detailed procedure for the analysis of exogenous dehydroepiandrosterone (DHEA) in urine by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) has been established for detecting doping with DHEA. The average delta-value (parts per thousand difference of (13)C/(12)C ratio from the isotope ratio standard) of 26 synthetic steroids commercially available was -30.1 +/- 2.6, and was significantly lower than that of human endogenous DHEA in urine of the world class athletes who had participated in the XVIIth Olympic Winter Games (-20.3 +/- 2.1, n = 446). Although large inter-individual variations of urinary DHEA excretion were observed following a single oral administration of 50 mg of DHEA, no significant inter-individual difference was found when the excretion of exogenous DHEA was monitored in terms of delta-values using GC/C/IRMS; the minimum delta-values were observed around 6-8 h after the administration, and the values returned to the base level at over 72 h after the dosing. Thus, the deviations in delta-values of DHEA and its diol metabolites are considered to be conclusive evidence for detecting doping with DHEA. Some successful cases of detection of doping with DHEA from athletes are also reported.  相似文献   

9.
Important aspects of glucose metabolism can be quantified by using the minimal model of glucose kinetics to interpret the results of intravenous glucose tolerance tests. The power of this methodology can be greatly increased by the addition of stable isotopically labelled tracer to the glucose bolus dose. This allows the separation of glucose disposal from endogenous glucose production and also increases the precision of the estimates of the physiological parameters measured. Until now the tracer of choice has been deuteriated glucose and the analytical technique has been gas chromatography/mass spectrometry (GC/MS). The consequence of this choice is that nearly 2 g of labelled material are needed and this makes the test expensive. We have investigated the use of (13)C-labelled glucose as the tracer in combination with gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) as the analytical technique. This methodology offers superior analytical precision when compared with the conventional method and so the amount of tracer used, and hence the cost, can be reduced considerably. Healthy non-obese male volunteers were recruited for a standard intravenous glucose tolerance test (IVGTT) protocol but 6,6-(2)H-glucose and 1-(13)C-glucose were administered simultaneously. Tracer/tracee ratios were derived from isotope ratio measurements of plasma glucose using both GC/MS and GC/C/IRMS. The results of these determinations indicated that the two tracers behaved identically under the test protocol. The combination of these results with plasma glucose and insulin concentration data allowed determination of the minimal model parameters S*g and S*i. The parameter relating to insulin-assisted glucose disposal, S*i, was found to be the same in the two techniques, but this was not the case for the non-insulin-dependent parameter S*g.  相似文献   

10.
Carbohydrate is an important pool in the terrestrial carbon cycle. The potential offered by natural and artificial 13C-labelling techniques should therefore be applied to the investigation of the dynamics of individual sugars in soils. For this reason, we evaluated the method of 13C sugar analysis by gas chromatography/combustion/isotope-ratio mass spectrometry (GC/C/IRMS) after hydrolysis and direct trimethylsilylation. Trimethylsilylation involved the addition of several carbon atoms per sugar. These atoms have to be taken into account in the estimation of the carbon isotope ratio. The analysis of standard and natural pentoses and hexoses of known 13C enrichments revealed that the number of analysed added carbon atoms was less than expected from stoichiometry. This was attributed to incomplete derivatization and/or incomplete oxidation of methylsilyl carbon before IRMS. Using a calibration of the number of analysed added carbon atoms, the isotope excess of enriched samples could be determined with a relative error close to 5%. Concerning the determination of natural abundances by GC/C/IRMS, we could measure the delta 13C of standard C3- and C4-derived sugars with an accuracy of +/-1.5 per thousand using the previous calibration. We were able to apply this technique to plant-soil systems labelled by pulse-chase of 13CO2, revealing the nature and dynamics of sugars in the plant rhizosphere.  相似文献   

11.
We have developed a method based on a double labeling with stable isotopes and gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) analyses to study amino acid exchange in a symbiotic plant-microbe association. Isotopic precision was studied for 21 standards including 15 amino acid derivatives, three N-protected amino acid methyl esters, three amines and one international standard. High correlations were observed between the δ(13)C and δ(15)N values obtained by GC/C/IRMS and those obtained by an elemental analyzer (EA) coupled to an isotope ratio mass spectrometer (R(2) = 0.9868 and 0.9992, respectively). The mean precision measured was 0.04‰ for δ(13)C and 0.28‰ for δ(15)N (n = 15). This method was applied in vivo to the symbiotic relationship between alfalfa (Medicago sativa L.) and N(2)-fixing bacteria. Plants were simultaneously labeled over 10 days with (13)C-depleted CO(2) ((12)CO(2)), which was assimilated through photosynthesis by leaves, and (15)N(2) fixed via nodules. Subsequently, the C and N isotope compositions (i.e. δ(13)C and δ(15)N) of free amino acids were analyzed in leaves and nodules by GC/C/IRMS. The method revealed the pattern of C and N exchange between leaves and nodules, highlighting that γ-aminobutanoic acid and glycine may represent an important form of C transport from leaves to the nodules. The results confirmed the validity, reliability and accuracy of the method for assessing C and N fluxes between plants and symbiotic bacteria and support the use of this technique in a broad range of metabolic and fluxomic studies.  相似文献   

12.
The depletion of glutathione (GSH) reported in very-low-birth-weight infants is implicated in several pathologies, especially if deficiency occurs during foetal development. The cause of this depletion is suggested to be modification of GSH turnover. To probe the role of GSH, a reliable non-invasive method adapted to very-low-birth-weight infants is required. In this paper, we report the preparation of the N,S-ethoxycarbonyl methyl ester derivatives of GSH and glycine and their application to the measurement of (13)C/(12)C ratios at natural abundance in erythrocyte samples by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). The technique allowed the determination of (13)C/(12)C ratios at natural abundance with a precision <3% and within-day and between-day variabilities both <4%. The method is able to determine accurately low (13)C-enrichments in GSH (0.00241 to 0.00753 Atom Percent Excess) in erythrocyte extracts following incubation with (13)C-glycine at low specific enrichment (approx. 1.5 atom %). Excellent agreement was obtained between the calculated GSH fractional synthesis rate (FSR) in human adult blood (approx. 300% day(-1)) using the low-enrichment (13)C-glycine/GC/C/IRMS protocol and that using highly enriched (13)C-glycine (99 atom %)/GC/MS with the same derivative. The GC/C/IRMS method was shown to be suitable to measure the in vitro GSH FSR (200-660% day(-1)) in human venous and arterial blood from the umbilical cord. This approach provides a good tool for studying the turnover of GSH in vitro in infants, allowing both the use of minimal amounts of tracer and negligible perturbation of endogenous precursor pools.  相似文献   

13.
The stable carbon isotope compositions of tetrols, erythritol and threitol were determined by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). Using four tetrols with various δ13C values derivatized by methylboronic acid, the carbon isotope analysis method achieved excellent reproducibility and high accuracy. There was no carbon isotopic fractionation during the derivatization processes. The differences in the carbon isotopic compositions of methylboronates between the measured and calculated ranged from ?0.20 to 0.12‰, within the specification of the GC/C/IRMS system. It was demonstrated that δ13C values of tetrols could be calculated by a simple mass balance equation between tetrols, methylboronic acid, and methylboronates. The analogous 2‐methyltetrols, marker compounds of photooxidation products of atmospheric isoprene, should have similar behavior using the same derivatization reagent. This method may provide insight on sources and sinks of atmospheric isoprene. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
A new derivatisation reaction applied to the analysis of steroids by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) was studied. The trimethylsilylated steroids were characterised by well-resolved chromatographic signals, no peak tailing, reproducible 13C/12C measurements (0.32 per thousand, n = 28), good signal-to-noise ratio and absolute intensity (5 x 10(-9) A, 20 ng), and a slow degradation of copper oxide pellets in the combustion furnace. In addition, two new metabolites and one precursor of testosterone in bovine have been brought into consideration and used for GC/C/IRMS measurements, namely, 3beta-hydroxy-5alpha-androstan-17-one (epiandrosterone), 3beta,17alpha-dihydroxy-5alpha-androstane, and 3beta,17alpha-dihydroxy-5-androstene. The new findings have been applied to an elimination study in bovine of testosterone metabolites after an intramuscular injection of testosterone enanthate. Significant differences (up to 4 per thousand) between testosterone metabolites and precursor were detectable at least three weeks after administration.  相似文献   

15.
A reference method to accurately define kinetics in response to the ingestion of glucose in terms of total, exogenous and endogenous glucose is to use stable‐isotope‐labelled compounds such as 2H and 13C glucose followed by gas chromatography/mass spectrometry (GC/MS) and gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) analysis. The use of the usual pentaacetyl (5Ac) derivative generates difficulties in obtaining accurate and reproducible results due to the two chromatographic peaks for the syn and anti isomers, and to the isotopic effect occurring during acetylation. Therefore, the pentaacetylaldononitrile derivative (Aldo) was validated for both isotopes, and compared with the 5Ac derivative. A correction factor including carbon atom dilution (stoichiometric equation) and the kinetic isotopic effect (KIE) was determined. Analytical validation results for the 2H GC/MS and 13C GC/C/IRMS measurements produced acceptable results with both derivatives. When 2H enrichments of plasma samples were ≤1 mol % excess (MPE), the repeatability (RSDAldo Intra assay and Intra day <0.94%, RSD5Ac Intra assay and Intra day <3.29%), accuracy (Aldo <3.4%, 5Ac <29.0%), and stability of the derivatized samples were significantly better when the Aldo derivatives of the plasma samples were used (p < 0.05). When the glucose kinetics were assessed in nine human subjects, after glucose ingestion, the plasma glucose 2H enrichments were identical with both derivatives, whereas the 13C enrichments needed a correction factor to fit together. Due to KIE variation, this correction factor was not constant and had to be calculated for each batch of analyses, to obtain satisfactory results. Mean quantities of exogenous glucose exhibit marked difference (20.9 ± 1.3g (5Ac) vs. 26.7 ± 2.5g (Aldo)) when calculated with stoichiometric correction, but fit perfectly when calculated after application of the correction factor (22.1 ± 1.3g (5Ac) vs. 22.9 ± 1.9g (Aldo)). Finally, the pentaacetylaldononitrile derivative, used here in GC/C/IRMS for the first time, enables measurement of 2H and 13C enrichments in plasma glucose with a single sample preparation. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
Two new procedures for wine ethanol 13C/12C isotope ratio determination, using high-performance liquid chromatography and gas chromatography isotope ratio mass spectrometry (HPLC/IRMS and GC/IRMS), have been developed to improve isotopic methods dedicated to the study of wine authenticity. Parameters influencing separation of ethanol from wine matrix such as column, temperature, mobile phase, flow rates and injection mode were investigated. Twenty-three wine samples from various origins were analyzed for validation of the procedures. The analytical precision was better than 0.15 per thousand, and no significant isotopic fractionation was observed employing both separative techniques coupled to IRMS. No significant differences and a very strong correlation (r = 0.99) were observed between the 13C/12C ratios obtained by the official method (elemental analyzer/isotope ratio mass spectrometry) and the proposed new methodology. The potential advantages of the developed methods over the traditional one are speed (reducing time required from hours to minutes) and simplicity. In addition, these are the first isotopic methods that allow 13C/12C determination directly from a liquid sample with no previous ethanol isolation, overcoming technical difficulties associated with sample treatment.  相似文献   

17.
We report a method for determining plasma und urinary [(15)N]urea enrichments in an abundance range between 0.37 and 0.52 (15)N atom% (0-0.15 atom% excess (APE) (15)N) using a dimethylaminomethylene derivative. Compared with conventional off-line preparation and (15)N analysis of urea, this method requires only small sample volumes (0.5 ml of plasma and 25 microl of urine). The (15)N/(14)N ratio of urea derivatives was measured by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). Two peaks were separated; one was identified by gas chromatography/mass spectrometry (GC/MS) as the complete derivatized urea. Calibration of the complete urea derivative was performed by linear regression of enrichment values of known standard mixtures. Replicate standard (6-465 per thousand delta(15)N) derivatizations showed a relative standard deviation ranging from 0.1 to 7%. In order to test the feasibility of the method, human subjects and rats ingested a single meal containing either 200 mg of [(15)N]glycine (95 AP (15)N) or 0.4 mg of [(15)N]-alpha-lysine (95 AP (15)N), respectively. Urine and plasma were collected at hourly intervals over 7 h after the meal intake. After (15)N glycine intake, maximum urinary urea (15)N enrichments were 330 and 430 per thousand delta(15)N (0.12 and 0.16 APE (15)N) measured by GC/C/IRMS, whereas plasma [(15)N]glycine enrichments were 2.5 and 3.3 APE (15)N in the two human subjects 2 h after the meal. (15)N enrichments of total urine and urine samples devoid of ammonia were higher enriched than urinary [(15)N]urea measured by GC/C/IRMS, reflecting the presence of other urinary N-containing substances (e.g. creatinine). In rats plasma urea (15)N enrichments were 15-20 times higher than those in urinary urea (10-20 per thousand delta(15)N). The different [(15)N]urea enrichments observed after ingestion of [(15)N]-labeled glycine and lysine confirm known differences in the metabolism of these amino acids.  相似文献   

18.
Gas chromatography/pyrolysis/isotope ratio mass spectrometry (GC/P/IRMS) is a relatively new method for on-line determination of (2)H/(1)H isotope ratios. The influence of different parameters on the (2)H/(1)H isotope ratios obtained in GC/P/IRMS has been thoroughly studied using several flavor compounds, such as 5-nonanone, linalool, menthol, linalyl acetate and 4-decanolide. The requirement of "conditioning" the pyrolysis reactor to obtain reliable delta(2)H(V-SMOW) values is discussed. Furthermore, the influence of the carrier gas flow of the gas chromatograph on the completeness of pyrolysis and subsequently on the delta(2)H(V-SMOW) values is investigated in detail. The linear range of the compounds investigated is determined. The results show that calibrating the GC/P/IRMS system with secondary standard substances is absolutely necessary in order to obtain reliable delta(2)H(V-SMOW) values. In view of interlaboratory comparability, validation procedures are recommended.  相似文献   

19.
Under most physiological conditions, glucose, or carbohydrate (CHO), homeostasis is tightly regulated. In order to mechanistically appraise the origin of circulating glucose (e.g. via either gluconeogenesis, glycogenolysis or oral glucose intake), and its regulation and oxidation, the use of stable isotope tracers is now a well-accepted analytical technique. Methodologically, liquid chromatography coupled to isotope ratio mass spectrometry (LC/IRMS) can replace gas chromatography coupled to combustion-isotope ratio mass spectrometry (GC/C/IRMS) for carrying out compound-specific (13)C isotopic analysis. The LC/IRMS approach is well suited for studying glucose metabolism, since the plasma glucose concentration is relatively high and the glucose can readily undergo chromatography in an aqueous mobile phase. Herewith, we report two main methodological approaches in a single instrument: (1) the ability to measure the isotopic enrichment of plasma glucose to assess the efficacy of CHO-based treatment (cocoa-enriched) during cycling exercise with healthy subjects, and (2) the capacity to carry out bulk isotopic analysis of labeled solutions, which is generally performed with an elemental analyzer coupled to IRMS. For plasma samples measured by LC/IRMS the data show a isotopic precision SD(δ(13)C) and SD(APE) of 0.7 ‰ and 0.001, respectively, with δ(13)C and APE values of -25.48 ‰ and 0.06, respectively, being generated before and after tracer administration. For bulk isotopic measurements, the data show that the presence of organic compounds in the blank slightly affects the δ(13)C values. Despite some analytical limitations, we clearly demonstrate the usefulness of the LC/IRMS especially when (13)C-glucose is required during whole-body human nutritional studies.  相似文献   

20.
Quantifying the concentrations of organics such as phospholipid fatty acids (PLFAs) and n‐alkanes and measuring their corresponding 13 C/12 C isotope ratios often involves two separate analyses; (1) quantification by gas chromatography flame ionisation detection (GC‐FID) or gas chromatography/mass spectrometry (GC/MS), and (2) 13 C‐isotope abundance analysis by gas chromatography/combustion/isotope ratio mass spectrometry (GC‐C‐IRMS). This requirement for two separate analyses has obvious disadvantages in terms of cost and time. However, there is a history of using the data output of isotope ratio mass spectrometers to quantify various components; including the N and C concentrations of solid materials and CO2 concentrations in gaseous samples. Here we explore the possibility of quantifying n‐alkanes extracted from sheeps' faeces and fatty acid methyl esters (FAMEs) derivatised from PLFAs extracted from grassland soil, using GC‐C‐IRMS. The results were compared with those from GC‐FID analysis of the same extracts. For GC‐C‐IRMS the combined area of the masses for all the ions (m/z 44, 45 and 46) was collected, referred to as 'area all', while for the GC‐FID analysis the peak area data were collected. Following normalisation to a common value for added internal standards, the GC‐C‐IRMS 'area all' values and the GC‐FID peak area data were directly compared. Strong linear relationships were found for both n‐alkanes and FAMEs. For the n‐alkanes the relationships were 1:1 while, for the FAMEs, GC‐C‐IRMS overestimated the areas relative to the GC‐FID results. However, with suitable reference material 1:1 relationships were established. The output of a GC‐C‐IRMS system can form the basis for the quantification of certain organics including FAMEs and n‐alkanes. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号