1.
Pressure assisted capillary electrophoresis in capillaries with internal diameters of 10 μm was found possible without significant penalty in terms of separation efficiency and sensitivity when using contactless conductivity detection. A sequential injection analysis manifold consisting of a syringe pump and valves was used to impose a hydrodynamic flow in the separation of some inorganic as well as organic cations. It is demonstrated that the approach may be used to optimize analysis time by superimposing a hydrodynamic flow parallel to the electrokinetic motion. It is also possible to improve the separation by using the forced flow to maintain the analytes in the capillary, and thus the separation field, for longer times. The use of the syringe pump allows flexible and precise control of the pressure, so that it is possible to impose pressure steps during the separation. The use of this was demonstrated for the speeding up of late peaks, or forcing repeated passage of the sample plug through the capillary in order to increase separation. 相似文献
2.
It is demonstrated that a hydrodynamic flow superimposed on the mobility of analyte anions can be used for the optimization of analysis time in capillary zone electrophoresis. It was also possible to use the approach for counter‐balancing the electroosmotic flow and this works as well as the use of surface modifiers. To avoid any band‐broadening due to the bulk flow narrow capillaries of 10 μm internal diameter were employed. This was enabled by the use of capacitively coupled contactless conductivity detection, which does not suffer from the downscaling, and detection down to between 1 and 20 μM for a range of inorganic and small organic anions was found feasible. Precisely controlled hydrodynamic flow was generated with a sequential injection manifold based on a syringe pump. Sample injection was carried out with a new design relying on a simple piece of capillary tubing to achieve the appropriate back‐pressure for the required split‐injection procedure. 相似文献
3.
A capillary electrophoresis (CE) instrument with capacitively coupled contactless conductivity detection (C4D) based on a sequential injection analysis (SIA) manifold was refined. Hydrodynamic injection was implemented to avoid a sampling bias by using a split-injection device based on a needle valve for precise adjustment. For safety and reliability, the integrity of the high voltage compartment at the detection end was fully maintained by implementing flushing of the high voltage interface through the capillary. With this set-up, extended fully automated monitoring applications are possible. The system was successfully tested in the field for the determination of the concentration levels of major inorganic cations and anions in a creek over a period of 5 days. 相似文献
4.
Thanh Duc Mai Benjamin Bomastyk Hong Anh Duong Hung Viet Pham Peter C. Hauser 《Analytica chimica acta》2012
An extension of a capillary electrophoresis instrument coupled to a sequential injection analysis manifold was developed for automated measurements with on-line solid-phase extraction preconcentration. An in-house built capacitively coupled contactless conductivity detector was employed for sensitive detection with narrow capillaries of 25 μm internal diameter. The system was assembled into standardized 19 in. frames and racks for easy transport and mobile deployment. The system can be left running unattendedly without manual intervention with good operation stability. To demonstrate the application of the system, a method for the determination of four drugs, namely ibuprofen, diclofenac, naproxen and bezafibrate, was developed with enrichment factors of up to several hundreds. Detection of the drug residues down to the nM-scale was found possible and the method was found suitable for the detection of ibuprofen in the waste water of a hospital in Hanoi. 相似文献
5.
The Raipore R1030 membrane, an anion-exchange membrane containing ammonium groups as ionogenic groups, was evaluated as the interface of an optical sensor for Cr(VI), and the effect of chemical parameters affecting Cr(VI) transport were studied. Good transport features were obtained, demonstrating the suitability of the Raipore R1030 membrane for this application. Thus, an optical sensor for chromium(VI) monitoring in industrial process waters was developed. The sensor is based on the renewable reagent approach and uses the Raipore R1030 membrane as the interface between the sample and the sensor head, which contains 1,5-diphenylcarbazide as spectrophotometric reagent for chromium. Chromium(VI) crosses the membrane and reacts with the reagent inside the sensor head, resulting in changes in the absorption of light. These changes are monitored in situ through a system of optical fibers. The sensor performance was tested by analysing samples from a waste water treatment plant for effluents from electroplating industries. 相似文献
6.
A purpose-made set-up featuring an automated fast injector allowed the easy optimization of the injected amount and the adjustment of the separation length of conventional capillaries from a minimum of 5 cm upward. It was found that a compromise in capillary length for separation efficiency and analysis time also has to take into account the injected amount, which in turn affects the sensitivity and hence the detection limit. The versatility of the system was demonstrated by the analysis of the major cations and anions in natural water samples in less than 1 min, the concurrent determination of a mixture of amino acids and carbohydrates in 160 s, and of three active ingredients in a pharmaceutical preparation in 40 s. Plate numbers were typically around 50,000 and detection limits down to 1 M could be achieved. 相似文献
7.
Reproducible injection in capillary electrophoresis has been difficult to achieve with manual injection techniques using simple injection devices, such as gravity injection (siphoning) or hydrodynamic sample splitting. We demonstrate that the injection reproducibility can be improved using very simple means. With hydrodynamic sample splitter, a passive micro-metering valve can be inserted in-line to regulate the sample flow rate through the splitter interface. A significant improvement of both reproducibility and repeatability was achieved. The reproducibility of RSD of the peak areas improved from 25.4% to 4.4%, while the repeatability was below 4.1% when micro-metering valve was used. Additional simple correction that can be used to further improve the variability of injected sample volumes in any hydrodynamic injection mode in CE with conductivity detection was proposed and verified. The measured EOF peak can serve as a simple indicator of the injected volume and can be effectively used for additional correction. By a linear function between the injection volume and the peak area of the EOF, the RSD values of peak areas for both manual gravity injection and hydrodynamic sample splitter were further improved below 2% RSD. The linearity of the calibration curve was also significantly improved. The proposed correction works even with slight differences in matrix composition, as demonstrated on the analysis aqueous soil extract of model mixture of five nerve agent degradation products. 相似文献
8.
Compared to other volatile carbonylic compounds present in outdoor air, formaldehyde (CH(2)O) is the most toxic, deserving more attention in terms of indoor and outdoor air quality legislation and control. The analytical determination of CH(2)O in air still presents challenges due to the low-level concentration (in the sub-ppb range) and its variation with sampling site and time. Of the many available analytical methods for carbonylic compounds, the most widespread one is the time consuming collection in cartridges impregnated with 2,4-dinitrophenylhydrazine followed by the analysis of the formed hydrazones by HPLC. The present work proposes the use of polypropylene hollow porous capillary fibers to achieve efficient CH(2)O collection. The Oxyphan fiber (designed for blood oxygenation) was chosen for this purpose because it presents good mechanical resistance, high density of very fine pores and high ratio of collection area to volume of the acceptor fluid in the tube, all favorable for the development of air sampling apparatus. The collector device consists of a Teflon pipe inside of which a bundle of polypropylene microporous capillary membranes was introduced. While the acceptor passes at a low flow rate through the capillaries, the sampled air circulates around the fibers, impelled by a low flow membrane pump (of the type used for aquariums ventilation). The coupling of this sampling technique with the selective and quantitative determination of CH(2)O, in the form of hydroxymethanesulfonate (HMS) after derivatization with HSO(3)(-), by capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C(4)D) enabled the development of a complete analytical protocol for the CH(2)O evaluation in air. 相似文献
9.
The development of efficient and sensitive analytical methods for the separation, identification and quantification of complex biological samples is continuously a topic of high interest in biological science. In the present study, the possibility of using a polyether ether ketone (PEEK) capillary for the CE separation of peptides, proteins and other biological samples was examined. The performance of the tubing was compared with that of traditional silica capillaries. The CE analysis was performed using contactless conductivity detection (C4D), which eliminated any need for the detection window and was suitable for the detection of optically inactive compounds. In the PEEK capillary the cathodic EOF was low and of excellent stability even at extremes pH. In view of this fast biological anions were analyzed using an opposite end injection technique without compromising separation. A comparison of the performances of fused‐silica and polymer capillaries during the separation of model sample mixtures demonstrated the efficiency and separation resolution of the latter to be higher and the reproducibility of the migration times and peak areas is better. Furthermore, PEEK capillaries allowed using simple experimental conditions without any complicated modification of the capillary surface or use of an intricate buffer composition. The PEEK capillaries are considered as an attractive alternative to the traditional fused‐silica capillaries and may be used for the analysis of complex biological mixtures as well as for developing portable devices. 相似文献
10.
采用场放大进样(FASI)-毛细管电泳非接触式电导检测法(CE-C4D),结合液液萃取(LLE)的样品净化预处理技术,分离检测了酱油中人工合成甜味剂安赛蜜。酱油样品经酸化后,用乙酸乙酯作为萃取剂,成功地消除了酱油中含有的大量无机盐等复杂基体对微量安赛蜜的干扰。实验对影响LLE萃取效率和FASI-CE-C4D分离检测的关键因素进行了讨论,特别是对样品净化前处理过程中萃取剂及用量、样品酸化pH值、萃取时间、萃取温度等条件进行了优化。结果表明,酱油中的安赛蜜可获得良好分离和灵敏检测,检出限和定量限分别为0.15 mg/kg和0.48 mg/kg。对市售酱油样品进行安赛蜜的加标回收测定,得到加标回收率为92.3%~108.1%,相对标准偏差<8.0%。该法具有简单快速、灵敏高效、分析成本低的优点,能满足酱油中安赛蜜的分析检测要求。 相似文献
11.
In the present study, field-amplified sample stacking injection using the electroosmotic flow pump (FAEP) was developed for the capillary electrophoretic separation of the four nerve agent degradation products methylphosphonic acid (MPA), ethyl methylphosphonic acid (EMPA), isopropyl methylphosphonic acid (IMPA) and cyclohexyl methylphosphonic acid (CMPA). Coupled to contactless conductivity detection, direct quantification of these non-UV active compounds could be achieved. Sensitivity enhancement of up to 500 to 750-fold could be obtained. The newly established approach was applied to the determination of the analytes in river water and aqueous extracts of soil. Detection limits of 0.5, 0.7, 1.4 and 2.7 ng/mL were obtained for MPA, EMPA, IMPA and CMPA, respectively, in river water and 0.09, 0.14, 0.44 and 0.22 μg/g, respectively, in soil. 相似文献
12.
A method of capillary electrophoresis with contactless conductivity detection has been developed for non‐enantioselective monitoring the anaesthetic ketamine and its main metabolite norketamine. The separation is performed in a 15 μm capillary with an overall length of 31.5 cm and length to detector of 18 cm; inner surface of the capillary is covered with a commercial coating solution to reduce the electroosmotic flow. In an optimised background electrolyte with composition 2 M acetic acid + 1% v/v coating solution under application of a high voltage of 30 kV, the migration time is 97.1 s for ketamine and 95.8 s for norketamine, with an electrophoretic resolution of 1.2. The attained detection limit was 83 ng/mL (0.3 μmol/L) for ketamine and 75 ng/mL (0.3 μmol/L) for norketamine; the number of theoretic plates for separation of an equimolar model mixture with a concentration of 2 μg/mL was 683 500 plates/m for ketamine and 695 400 plates/m for norketamine. Laboratory preparation of rat blood plasma is based on mixing 10 μL of plasma with 30 μL of acidified acetonitrile, followed by centrifugation. A pharmacokinetic study demonstrated an exponential decrease in the plasma concentration of ketamine after intravenous application and much slower kinetics for intraperitoneal application. 相似文献
13.
A single line flow injection analysis (FIA) method that incorporated a preconcentrator column packed with C(18) particles and capacitively coupled contactless conductivity detector (C(4)D) was developed for the determination of free fatty acid (FFA) in vegetable oils. The carrier stream was methanol/1.5 mM sodium acetate (pH 8) 80:20 (v/v) at a flow rate of 1.0 mL min(-1). Calibration curve was well correlated (r(2)=0.9995) within the range of 1-200 mg L(-1) FFA (expressed as palmitic acid). Sampling rate of 40-60 h(-1) was achieved. Good agreement was found between the standard non-aqueous titrimetry method and the proposed method when applied to the determination of FFA in palm (crude, olein, and refined, bleached and deodorised) and other vegetable (soybean, rice bran, walnut, corn and olive) oils. The proposed method offers distinct advantages over the official method, especially in terms of simplicity, high sampling rate, economy of solvents and sample, offering considerable promise as a low cost automated system that needs minimum human intervention over long periods of time. 相似文献
14.
《Journal of separation science》2017,40(4):940-947
An axial design of a capacitively coupled contactless conductivity detector was tested in combination with fused‐silica capillaries with internal diameters of 10, 15, and 25 μm, which are used for high‐efficiency electrophoretic separation. The transmission of the signal in the detection probe dependent on the specific conductivity of the solution in the capillary in the range 0–278 mS.m−1 has a complex character and a minimum appears on the curve at very low conductivities. The position of the minimum of the calibration dependence gradually shifts with decreasing frequency of the exciting signal from 1.0 to 0.25 MHz toward lower specific conductivity values. The presence of a minimum on the calibration curves is a natural property of the axial design of contactless conductivity detector, demonstrated by solution of the equivalent electrical circuit of the detection probe, and is specifically caused by the use of shielding foil. The behavior of contactless conductivity detector in the vicinity of the minimum was documented for practical separations of amino acids in solutions of 3.2 M acetic acid with addition of 0–50% v/v methanol. 相似文献
15.
Zacharis CK Tzanavaras PD Themelis DG Theodoridis GA Economou A Rigas PG 《Analytical and bioanalytical chemistry》2004,379(5-6):759-763
The present work reports for the first time a simple and rapid method for the spectrofluorimetric determination of lisinopril (LSP) in pharmaceutical formulations using sequential injection analysis (SIA). The method is based on reaction of LSP with o-phthalaldehyde (OPA) in the presence of 2-mercaptoethanol (borate buffer medium, pH=10.6). The emission of the derivative is monitored at 455 nm upon excitation at 346 nm. The various chemical and physical conditions that affected the reaction were studied. The calibration curve was linear in the range 0.3–10.0 mg L–1 LSP, at a sampling rate of 60 injections h–1. Consumption of OPA reagent was significantly reduced compared with conventional flow injection (FI) systems, because only 50 L of OPA was consumed per run. The method was found to be adequately precise (sr=2% at 5 mg L–1 LSP, n=10) and the 3 detection limit was 0.1 mg L–1. The method was successfully applied to the analysis of two pharmaceutical formulations containing LSP. The results obtained were in good agreement with those obtained by use of high-performance liquid chromatography (HPLC), because the mean relative error, er, was <1.8%. 相似文献
16.
A simultaneous detection sequential injection analysis (SIA) system is proposed for the determination of S and R captopril using a potentiometric, enantioselective membrane electrode based on maltodextrin (DE=14-17) for the assay of S-captopril and an amperometric biosensor for the assay of R-captopril. The proposed SIA system can be utilized reliably for the on-line simultaneous detection of the enantiomers in the synthesis process at a rate of 38 samples per hour in the following linear concentration ranges: 100-1000 nmol/l (R-captopril) and 1-1000 mumol/l (S-captopril) with a RSD better than 0.009% (n=10). 相似文献
17.
N,N'-Alkylmethylimidazolium cations have been separated in NACE when one of the N,N'-dialkylimidazolium salts (ionic liquids (ILs)) was used as an electrolyte additive to the organic solvent separation medium. The separated species were 1-methyl-, 1-ethyl-, 1-butyl-, 1-octyl-, 1-decyl-3-methylimidazolium and N-butyl-3-methylpyridinium cations and BGE composed of 1-ethyl-3-methylimidazolium ethylsulfate or 1-butyl-3-methylimidazolium trifluoroacetate [BMIm][FAcO] (A6; B2) diluted in ACN. It was demonstrated that contactless conductivity detection (CCD) may be applied to monitoring the separation process in nonaqueous separation media, allowing to use the UV light-absorbing imidazolium-based electrolyte additives. There could be marked three concentration regions of added ILs; at first ionic strength of BGE below 1-2 mM, and then the actual electrophoretic mobility of analytes rises from 0. At concentrations above 1-2 mM, the added IL facilitated separation. In concentration region of 1-20 mM, the actual electrophoretic mobility of analyzed imidazolium cations was increasing with decrease in separation medium ionic strength. At higher concentrations of BGE (above 30 mM), the conductivity of the separation media became too high for this detector. Some organic dyes were also successfully separated and detected by contactless conductivity detector in a 20 mM A6 separation electrolyte in ACN. 相似文献
18.
A simple method for producing PMMA electrophoresis microchips with in‐plane electrodes for capacitively coupled contactless conductivity detection is presented. One PMMA plate (channel plate) is embossed with the microfluidic and electrode channels and lamination bonded to a blank PMMA cover plate of equal dimensions. To incorporate the electrodes, the bonded chip is heated to 80°C, above the melting point of the alloy (≈70°C) and below the glass transition temperature of the PMMA (≈105°C), and the molten alloy drawn into the electrode channels with a syringe before being allowed to cool and harden. A 0.5 mm diameter stainless steel pin is then inserted into the alloy filled reservoirs of the electrode channels to provide external connection to the capacitively coupled contactless conductivity detection detector electronics. This advance provides for a quick and simple manufacturing process and negates the need for integrating electrodes using costly and time‐consuming thin film deposition methods. No additional detector cell mounting structures were required and connection to the external signal processing electronics was achieved by simply slipping commercially available shielded adaptors over the pins. With a non‐optimised electrode arrangement consisting of a 1 mm detector gap and 100 μm insulating distance, rapid separations of ammonium, sodium and lithium (<22 s) yielded LODs of approximately 1.5–3.5 ppm. 相似文献
19.
Jonas Josef Peter Mark Paolo Piccinelli Frank-Michael Matysik 《Analytical and bioanalytical chemistry》2014,406(24):6069-6073
A method for conducting fast and efficient capillary electrophoresis (CE) based on short separation capillaries in vertical alignment was developed. The strategy enables for high-throughput analysis from small sample vials (low microliter to nanoliter range). The system consists of a lab-made miniaturized autosampling unit and an amperometric end-column detection (AD) cell. The device enables a throughput of up to 200 separations per hour. CE-AD separations of a dye model system in capillaries of only 4 to 7.5 cm length with inner diameters (ID) of 10 or 15 μm were carried out under conditions of very high electric field strengths (up to 3.0 kV/cm) with high separation efficiency (half peak widths below 0.2 s) in less than 3.5 s migration time. A non-aqueous background electrolyte, consisting of 10 mM ammonium acetate and 1 M acetic acid in acetonitrile, was used. The practical suitability of the system was evaluated by applying it to the determination of dyes in overhead projector pens. Fig. 1
Schematic illustration of high-throughput capillary electrophoresis with electrochemical detection 相似文献
20.
Reine Nehmé 《Analytica chimica acta》2010,663(2):190-197
In this work, a capillary electrophoresis (CE) procedure was developed for the simultaneous determination of a pharmaceutical drug and its counter-ion, namely labetalol hydrochloride. For this purpose, an uncoated fused-silica capillary, a low conductivity background electrolyte (BGE) and a capacitively coupled contactless conductivity detector (C4D) were employed. This detection system is highly sensitive and enables detection of inorganic as well as organic ions unlike with direct UV detection. Moreover, to be able to simultaneously analyze the cationic drug (labetalol+) and its anionic counter-ion (Cl−) in the same electrophoretic run without the need of a coated capillary, a dual-opposite end injection was performed. In this technique, the sample is hydrodynamically injected into both ends of the capillary. This method is simple and easy to perform since the different injection steps are automated by the CE software.This novel CE-C4D procedure with dual-opposite end injection has been successfully validated and applied for the analysis of chloride content in an adrenergic antagonist (labetalol hydrochloride). Thus, the hereby developed method has been shown to enable fast (analysis time < 10 min), precise (repeatability of migration times < 0.7% and of corrected-peak areas < 3.3%; n = 6) and rugged analyses for the simultaneous determination of a pharmaceutical drug and its counter-ion. 相似文献