共查询到20条相似文献,搜索用时 15 毫秒
1.
Tomáš Hložek Martin Štícha Miroslava Bursová Ivan Jelínek Petr Tůma Radomír Čabala 《Electrophoresis》2020,41(18-19):1564-1567
Riociguat is novel antihypertensive drug for treatment of pulmonary hypertension. As such, it is still being tested in many clinical and pharmacokinetic trials. Existing methods that determine serum riociguat and desmethylriociguat (DMR) are based solely on liquid chromatography with mass spectrometry. Therefore, we present a novel capillary electrophoresis with mass spectrometry method (CE-MS) for their determination in human serum as alternative method for ongoing trials. Complete resolution of both analytes was achieved by means of pH optimization of ammonium formate background electrolytes that are fully compatible with ESI/MS detection. Simple liquid-liquid extraction was used as sample pretreatment. The calibration dependence of the method was linear (in the range of 10–1000 ng/mL), with adequate accuracy (90.1–114.9%) and precision (13.4%). LOD and LOQ were arbitrarily set at 10 ng/mL for both analytes. Clinical applicability was validated using serum samples from patients treated with riociguat in pharmacokinetic study and the results corresponded with reference HPLC-MS/MS values. Capillary electrophoresis proved to be sensitive and selective tool for the analysis of riociguat and DMR. 相似文献
2.
The rapid gas chromatographic detection and determination of ethylene glycol in biological fluids is described. Phenylboronic acid in acetone was used for the esterification of glycol. The phenylboronates of ethylene glycol and 1,2-propylene glycol are not separated on a packed column of medium polarity (OV-17), but they can be separated on a non-polar column (OV-101). In both instances, 1,3-propylene glycol can be used as an internal standard. The method requires only 100 microliters of serum or urine and is suitable for trace analysis in an emergency toxicological laboratory. The utility of the method is demonstrated on two cases of human intoxication with ethylene glycol. 相似文献
3.
Analytical and Bioanalytical Chemistry - 相似文献
4.
Application of the Pummerer reaction to Biotin sulfoxides gives a good access to the corresponding thiolactol and thiolactone, which are key-compounds for the synthesis of new functionalized Biotin derivatives. 相似文献
5.
Potentiometric electrodes were developed for the rapid determination of proguanil hydrochloride in pure samples, pharmaceutical preparations and spiked serum and urine samples using PVC membrane,screen printed(SPE), coated wired(CWE), carbon paste(CPE) and modified carbon paste(MCPE)electrodes based on the ion-exchanger of proguanil with phosphotungestic acid(Pr-PT) as a chemical modifier. The prepared electrodes showed Nernestian slopes of 59.7, 58.1, 58.5, 58.5 and 57.0 for the PVC,SPE, CWE, CPE and MCPE for the proguanil ions in a wide concentration range of 1.0 * 10~(-5)–1.0 * 10~(-2)mol L~(-1) at 25°C with detection limits of 7.94 * 10~(-6), 1.0 * 10~(-5), 1.0 * 10~(-6), 7.07 * 10~(-6) and 2.5 * 10~(-6) mol L~(-1), respectively. The prepared electrodes exhibited high proguanil selectivity in relation to several inorganic ions and sugars and they could be successfully utilized for its determination in pure solutions, pharmaceutical preparations and serum and urine samples using the direct potentiometry and standard addition methods with very good recovery values. 相似文献
6.
For the internal dosimetry of plutonium, a urine bioassay method is very useful but requires several days to obtain the result of the analysis. To shorten the time required for the urine bioassay, a rapid method for plutonium analysis using the ICP-MS system was developed. In this chemical procedure, a microwave oven was applied for sample digestion, and an extraction chromatography resin was used for the separation of plutonium. The measurement time was extremely reduced by application of the ICP-MS as compared to alpha-spectrometry. The total analysis time was about 12 hours and the detection limit was 0.3 mBq/sample. The short analysis time and the low detection limit indicate that this method is useful not only for special monitoring but also for routine monitoring. 相似文献
7.
A spectrofluorimetric method, involving alkaline degradation and formation of a magnesium complex, is described for the determination of tetracycline (TC) and anhydrotetracycline (ATC) in their mixed solution. Tetracycline is degraded and determined in alkaline solution. This treatment of ATC produces almost no fluorescence, but a fluorescent magnesium complex forms at pH 7.5. Several synthetic samples of TC and ATC, with TC:ATC ratios ranging from 50:1 to 1:50, were analysed. The recoveries of TC and ATC are about 71-76 and 61-63% in serum, respectively, and are all about 100% in urine. 相似文献
8.
In the presented work, a disposable immunosensor for the detection of testosterone, an endogenous steroid hormone, in bovine urine has been developed using screen-printed electrodes (SPEs). Due to concerns over the use of steroid hormones as growth promoters, the EU prohibits their use in food producing animals. Consequently, rigorous screening procedures have been implemented in all member states to detect the illegal administration of such compounds. Competitive immunoassays were developed, initially by enzyme linked immunosorbent assay (ELISA), and subsequently transferred to an electrochemical immunosensor format using disposable screen-printed carbon electrodes. Horseradish peroxidase (HRP) was the enzyme label of choice and chronoamperometric detection was carried out using a tetramethylbenzidine/hydrogen peroxide (TMB/H2O2) substrate system, at +100 mV. The EC50 values obtained for the assay in buffer and urine gave relatively comparable results, 710 pg mL−1 and 960 pg mL−1, respectively. The linear range obtained for the assay in buffer extended from 0.03 ng mL−1 to 40 ng mL−1; while that in urine ranged from 0.03 ng mL−1 to 1.6 ng mL−1. The corresponding limits of detection (LOD) in buffer and urine were 26 pg mL−1 and 1.8 pg mL−1. Cross reactivity profiles of the antibody have been examined, with notable cross reactivities with 19-nortestosterone (11.6%) and boldenone (9.86%). Precision studies for the sensor demonstrated adequate reproducibility (CV < 13%, n = 3) and repeatability (CV < 9%, n = 3). Recovery data obtained showed good agreement between spiking studies and known concentrations of analyte. Sensors showed stability for 4 days at +4 °C. A sensitive, highly specific, inexpensive, disposable immunosensor, showing excellent overall performance for the detection of testosterone in bovine urine, has been developed. 相似文献
9.
Jing-Yuan Hou Tian-Cai LiuGuan-Feng Lin Zhi-Xiong LiLi-Ping Zou Ming LiYing-Song Wu 《Analytica chimica acta》2012
A novel immunoassay for the determination of tumor markers in human serum was established by combining a time-resolved fluoroimmunoassay (TRFIA) and immunomagnetic separation. Based on a sandwich-type immunoassay format, analytes in samples were captured by magnetic beads coated with one monoclonal antibody and “sandwiched” by another monoclonal antibody labeled with europium chelates. The immunocomplex was separated and washed by exposure to a magnetic field and treatment with enhancement solution; fluorescence was then measured according to the number of europium ions dissociated. Levels of the model analyte, carcinoembryonic antigen (CEA), were determined in a linear range (1–1000 ng mL−1) with a limit of detection of 0.5 ng mL−1 under optimal conditions. The reproducibility, recovery, and specificity of the immunoassay were demonstrated to be acceptable. To evaluate this novel assay for clinical applications, 239 serum samples were evaluated. Compared with the conventional TRFIA and chemiluminescence immunoassay (CLIA), the correlation coefficients of the developed immunoassay were 0.985 and 0.975, respectively. These results showed good correlation and confirmed that our method is feasible and could be used for the clinical determination of CEA (or other tumor antigens) in human serum. 相似文献
10.
A rapid, sensitive procedure for the analysis of Oltipraz in serum and urine using high-performance liquid chromatography was developed. The proposed method illustrates recovery of Oltipraz from biological fluids was greater than 80%. Detection and separation of Oltipraz required as little as 1 ml of serum or urine. Oltipraz was detectable when 2 ng or more of drug was present in 1 ml of serum or urine; the method is highly reproducible when 5 ng/ml or more Oltipraz is present in the biological fluid. 相似文献
11.
The anti-schizophrenic drug risperidone (RSP) exerts an inhibitory effect on the chemiluminescence (CL) of the luminol-lysozyme system. This finding forms the basis for a sensitive flow injection method for its determination at picogram levels. RSP binds to Trp62 in the lysozyme, and this leads to a conformational change upon which the CL of the system is quenched. The decrease in CL is proportional to the logarithm of the concentration of RSP, and the calibration graph is linear in the range from 0.1 pg?mL?1 to 1.0 ng?mL?1, with relative standard deviations of <5.0%, and a detection limit of 0.05 pg?mL?1 (3σ). At a flow rate of 2.0 mL?min?1, the whole process including sampling and washing is completed within 20 s. The method was successfully applied to monitoring RSP in human urine after incorporation of 2 mg of RSP, with a total excretion of 16.6% within 8.5 h. Figure
The reaction of lysozyme with risperidone using luminol as luminescence reagent by the luminol-lysozyme FI-CL system and its application. 相似文献
12.
An enzyme-linked immunosorbent assay (ELISA) method was employed for determination of the pyrethroid biomarker, 3-phenoxybenzoic acid (3-PBA) in human urine samples. The optimized coating antigen concentration was 0.5 ng/mL with a dilution of 1:4000 for the 3-PBA antibody and 1:6000 for the enzyme conjugate. Urine samples were hydrolyzed with concentrated hydrochloric acid; extracted with dichloromethane and solvent-exchanged into a methanol/buffer solution, prior to analysis in a 96-microwell plate immunoassay. Quantitative recoveries of 3-PBA were obtained for fortified urine samples by ELISA (92 ± 18%) as well as by gas chromatography/mass spectrometry (GC/MS) (90 ± 13%). The overall method precision of these samples was within ±20% for both the ELISA and GC/MS methods. Analytical results from over one hundred urine samples showed that the ELISA and GC/MS data were highly correlated, with a correlation coefficient of 0.95. At the 10 ng/mL comparative concentration level, the false positive rate was 0% and the false negative rate was 0.8% for ELISA when using GC/MS as the reference method. The ELISA method has a suitable low detection limit for 3-PBA to assess pyrethroid exposures in non-occupational settings. 相似文献
13.
Determination of sparfloxacin in serum and urine by high-performance liquid chromatography. 总被引:3,自引:0,他引:3
A specific and sensitive analytical method for the determination of sparfloxacin in serum and urine is described. Serum proteins are removed by precipitation with acetonitrile after the addition of ofloxacin as an internal standard. The supernatant solvent is evaporated in a vacuum concentrator and the dry residue is redissolved in the mobile phase. Separation is performed on a cation-exchange column (Nucleosil 100 5SA, 125 x 4.0 mm I.D., 5 microns particle size) protected by a guard column (Perisorb RP-18, 30 x 4.0 mm I.D., 30-40 microns particle diameter). The mobile phase consisted of 750 ml of acetonitrile and 250 ml of 100 mmol/l phosphoric acid (v/v) to which sodium hydroxide had been added. The final concentration of sodium was 23 mmol/l and the pH was 3.82. Sparfloxacin and ofloxacin were determined by spectrofluorimetry (excitation wavelength 295 nm; emission wavelength 525 nm). The flow-rate was 1.5 ml/min and the retention times were 4.7 (sparfloxacin) and 8.0 (ofloxacin) min. Validation of the method yielded the following results for serum: detection limit 0.05 mg/l; precision between series 10.4-3.6%; recovery 99.5-100.0%; comparison with a microbiological assay c(bioassay) = 1.035c(HPLC) - 0.06. The test organism was Bacillus subtilis ATCC 6633. For urine the results were: detection limit 0.5 mg/l; precision between series 7.8-5.0%; recovery 97.0-97.8%; method comparison c(bioassay) = 1.092c(HPLC) - 1.09. No interferences were observed in human volunteers. The method can also be applied to stool samples. 相似文献
14.
15.
I Helleberg 《Journal of chromatography. A》1976,117(1):167-173
A specific and sensitive method for the quantitative determination of indomethacin in serum and urine is described. The drug is extracted at pH 5.0 with 1,2-dichloroethane and a portion of the organic extract is concentrated and made to react with diazoethane in diethyl ether. The ethyl ester derivative is analyzed by electron-capture gas-liquid chromatography, quantitation being achieved by comparison of peak areas for samples and standards, which are prepared in serum or urine and treated in the same manner as the samples. The limit of sensitivity is 50 ng/ml and the relative standard derivation for repeat determinations on the same sample is about 3%. 相似文献
16.
17.
N. P. Singh 《Journal of Radioanalytical and Nuclear Chemistry》1995,197(1):41-50
A critical review is presented of bioassay techniques for actinides in light of ICRP recommendations for monitoring workers. It is obvious that very sensitive techniques are required to meet these recommendations. Alpha spectrometry, the most commonly employed technique for measuring actinides in bioassay samples, has limited sensitivity. There are, however, certain techniques which are sensitive enough to meet the recommendations of ICRP, such as, fission track analysis for239Pu and235U, neutron activation analysis for232Th, mass spectrometry for a number of radionuclides, and many techniques for uranium. ICP-mass spectrometry does not have enough sensitivity to be implemented as a method of choice for the bioassay of actinides at present, however, it is quite promising. 相似文献
18.
Determination of disopyramide and its mono-N-dealkylated metabolite in blood serum and urine. 总被引:2,自引:0,他引:2
A rapid, precise and accurate assay for disopyramide and mono-N-dealkylated disopyramide concentrations in blood serum and urine is described. The method involves extraction of the drugs from a basic aqueous medium into chloroform, derivatization of the metabolite, purification of the extract and gas chromatographic analysis using an OV-17 liquid phase and flame ionization detection. Unique characteristics of the procedure, direct derivatization in the organic phase and the use of Florisil to separate the drugs from interfering materials, should be applicable to the analysis of other basic drugs in biological specimens. 相似文献
19.
A rapid immunochromatographic assay was developed and validated for detection of 1-aminohydantoin (AHD) in urine specimens. Colloidal gold-labeled polyclonal antibody specific to AHD derivative was used as the marker; based on the competitive reactivity theory, the metabolite of nitrofurantoin after derivatization with benzaldehyde would compete with carboxyphenyl AHD derivative-conjugated ovalbumin. The test strip could efficaciously detect the novel analyte with a visual detection limit of 10 ng mL(-1) and high specificity. The reliability of the assay was determined by testing 80 standard samples comparing with enzyme-linked immunosorbent assay. The semi-quantitative detection was accomplished in less than 15 min with low cost, especially for requirements of rapid and simple screening. This is the first publication of an immunochromatographic assay for detection of nitrofuran residues. 相似文献
20.
A high-pressure anion-exchange chromatographic system has been modified to provide measurement of large numbers of molecular constituents in serum and for direct comparison to similar measurement in urine. Operating parameters have been adopted which greatly extend the range of elution for strongly retained anionic constituents and limit resolution of early-eluting basic and neutral compounds which were of less interest in this study. Dual monitoring by UV absorption and fluorescence produced by cerate oxidation provides both sensitive and wide-ranging detection capability. Comparative serum and urine chromatograms for a clinically normal subject, a subject after ingesting the drug 4-hydroxyacetanilide, and an infant suffering from extreme acidosis, illustrate the potential usefulness of this analysis in studying the origin, transport, in vivo reactions, and disposition of metabolites. 相似文献