首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
We describe a novel magnetic metal-organic framework (MOF) for the preconcentration of Cd(II) and Pb(II) ions. The MOF was prepared from the Fe3O4-pyridine conjugate and the copper(II) complex of trimesic acid. The MOF was characterized by IR spectroscopy, elemental analysis, SEM and XRD. A Box-Behnken design through response surface methodology and experimental design was used to identify the optimal parameters for preconcentration. Extraction time, amount of magnetic MOF and pH value were found to be critical factors for uptake, while type, volume, concentration of eluent, and elution time are critical in the elution step. The ions were then determined by FAAS. The limits of detection are 0.2 and 1.1 μg?L?1 for Cd(II), and Pb(II) ions, respectively, relative standard deviations are <4.5% (for five replicates at 50 μg?L?1 of Cd(II) and Pb(II) ions), and the enrichment capacity of the MOF is at around 190 mg?g?1 for both ions which is higher than the conventional Fe3O4-pyridine material. The magnetic MOF was successfully applied to the rapid extraction of trace quantities of Cd(II) and Pb(II) ions in fish, sediment, and water samples.
Figure
Schematic illustration of synthesized magnetic MOF-pyridine nanocomposite  相似文献   

2.
We report on the synthesis of Fe3O4-functionalized metal-organic framework (m-MOF) composite from Zn(II) and 2-aminoterephthalic acid by a hydrothermal reaction. The magnetic composite is iso-reticular and was characterized by FTIR, X-ray diffraction, SEM, magnetization, and TGA. The m-MOF was then applied as a sorbent for the solid-phase extraction of trace levels of copper ions with subsequent quantification by electrothermal AAS. The amount of sorbent applied, the pH of the sample solution, extraction time, eluent concentration and volume, and desorption time were optimized. Under the optimum conditions, the enrichment factor is 50, and the sorption capacity of the material is 2.4 mg g?1. The calibration plot is linear over the 0.1 to 10 μg L?1 Cu(II) concentration range, the relative standard deviation is 0.4 % at a level of 0.1 μg L?1 (for n?=?10), and the detection limit is as low as 73 ng L?1. We consider this magnetic MOF composite to be a promising and highly efficient material for the preconcentration of metal ions.
Figure
Magnetic metal-organic frameworks was synthesized and used as a new sorbent for lead adsorption with detection by electrothermal atomic absorption spectrometry.  相似文献   

3.
We have developed a fast method for sensitive extraction and determination of the metal ions silver(I), gold(III), copper(II) and palladium(II). Fe3O4 magnetic nanoparticles were modified with polythiophene and used for extraction the metal ions without a chelating agent. Following extraction, the ions were determined by flow injection inductively coupled plasma optical emission spectrometry. The influence of sample pH, type and volume of eluent, amount of adsorbent, sample volume and time of adsorption and desorption were optimized. Under the optimum conditions, the calibration plots are linear in the 0.75 to 100 μg L?1 concentration range (R2?>?0.998), limits of detection in the range from 0.2 to 2.0 μg L?1, and enhancement factors in the range from 70 to 129. Precisions, expressed as relative standard deviations, are lower than 4.2 %. The applicability of the method was demonstrated by the successful analysis of tap water, mineral water, and river water.
Figure
In the present work, polythiophene-coated Fe3O4 nanoparticles have been successfully synthesized and were applied as adsorbent for magnetic solid-phase extraction of some precious metal ions.  相似文献   

4.
We have developed a convenient, selective and reliable method for the rapid enrichment of trace quantities of Cu(II) by using a magnetic Cu(II) ion-imprinted polymer. This is followed by their determination by FAAS. The imprints were prepared by using (a) Cu(II) ions as the template, (b) 3-aminopropyltriethoxysilane as both the functional monomer and the crosslinking agent, and (c) Fe3O4 as the magnetic component. Enrichment is carried out in a single step, and adsorbed copper ions can be separated from the sample solution by applying a strong magnet. The effects of pH, elution condition, amount of imprint, and of potentially interfering ions were evaluated. Under the optimal conditions, the detection limit and enrichment factor are 0.3?μg L?1 and 100, respectively, and the recovery is >95?%. The procedure was successfully applied in the enrichment and detection of trace copper ions in environmental water.
Figure
General procedure for preconcentration/recovery of Cu (II) ions  相似文献   

5.
We present a study on the application of magnetic nanoparticles (MNPs) prepared from Fe3O4 and functionalized with pyridine as an adsorbent for the solid-phase extraction of trace quantities of Pd(II) ion. The pyridine group was immobilized on the surface of the MNPs by covalent bonding of isonicotinamide. The modified MNPs can be readily separated from an aqueous solution by applying an external magnetic field. Effects of pH, the amount of functionalized MNPs, extraction time, type and quantity of eluent, desorption time, break-through volume and interfering ions on the extraction efficiency were optimized. The amount of Pd(II) was then determined using FAAS. Under the optimized conditions, the detection limit and preconcentration factor are 0.15?μg?L-1 and 196, respectively, and the relative standard deviation (at 20?μgL?1; for n?=?10) is 3.7?%. The method had a linear analytical range from 1 to 80?μg?L-1 and was applied to determine Pd(II) in spiked tape water and soil.
Figure
?  相似文献   

6.
We report on the separation and preconcentration of lead(II) and copper(II) ions using silver-coated titanium dioxide nanoparticles modified with cysteamine, and their determination by slurry analysis via flame atomic absorption spectrometry. The ions were adsorbed via a conventional batch technique, and the ion-loaded slurry was separated and directly introduced into the spectrometer, thereby eliminating a number of drawbacks. The effects of pH, amount of sorbent, slurry volume, sample volume and other ions on the recovery were investigated. Under optimized experimental conditions, copper and lead can be recovered within the 95% confidence level in certificated waste water, but also in spiked sea water samples. The technique is fast, simple, and leads to complete elution. The limit of detection (3δ, at n?=?10) was 0.37 μg L?1 for Cu(II), and 0.38 μg L?1 for Pb(II).
Figure
We report on the separation and preconcentration of lead(II) and copper(II) ions using silver-coated titanium dioxide nanoparticles modified with cysteamine (Fig. 1), and their determination by slurry analysis via flame atomic absorption spectrometry. Under optimized experimental conditions, copper and lead can be recovered within the 95% confidence level in certificated waste water and spiked sea water samples. The technique is fast, simple, and leads to complete elution. Figure 1. Schematic illustration of the preparation of TiO2@Ag–Cysteamine nanoparticles and inset shows the color of the nanoparticles.  相似文献   

7.
We report on a glassy carbon electrode (GCE) modified with a lead ionophore and multiwalled carbon nanotubes. It can be applied to square wave anodic stripping voltammetric determination of Pb(II) ion after preconcentration of Pb(II) at ?1.0?V (vs. SCE) for 300?s in pH?4.5 acetate buffer containing 400?μg?L?1 of Bi(III). The ionophore-MWCNTs film on the GCE possesses strong and highly selective affinity for Pb(II) as confirmed by quartz crystal microbalance experiments. Under the optimum conditions, a linear response was observed for Pb(II) ion in the range from 0.3 to 50?μg?L?1. The limit of detection (at S/N?=?3) is 0.1?μg?L?1. The method was applied to the determination of Pb(II) in water samples with acceptable recovery.
Figure
A glassy carbon electrode modified with a lead ionophore and multiwalled carbon nanotubes is successfully applied to sensitive and selective square wave anodic stripping voltammetric determination of Pb(II) ion after preconcentration of Pb(II) at ?1.0?V (vs. SCE) in pH?4.5 solutions containing 400?μg?L?1 of Bi(III).  相似文献   

8.
9.
We report on a sensitive, reliable and relatively fast method for separation, preconcentration and determination of trace quantities of copper(II) ion. It is making use of nanometer-sized γ-alumina nanoparticles modified with sodium dodecyl sulfate (SDS). The adsorptive potential was assessed via a Langmuir isotherm and the maximal sorption capacity was found to be 138 mg g-1. The effects of pH values, amount of ligand, flow rate, type of eluting agent, volume of eluent, and the volume of sample were examined. The effects of interfering ions on the recovery of the analyte were also investigated. Copper ion was then determined by flame atomic absorption spectrometry. The relative standard deviation for five replicate determinations (at 50 μg L?1 of copper) is 3.3%. The detection limit (at 3 s) is 2.5 μg L?1. This method was validated with a certified reference material of oyster tissue (NIST SRM 1566b) and the results coincided well with the certified values. The procedure was successfully applied to the determination of Cu in water and food samples.
Figure
Alumina nanoparticles modified with SDS have been used as sorbent for separation and preconcentration of copper after complexation with APDC.  相似文献   

10.
We describe a method for the determination of inorganic selenium in water samples via gas-phase chemiluminescence (GPCL). Se(IV) was first derivatized with 4-nitro-o-phenylenediamine to form 5-nitropiazselenol. The latter was decomposed by persulfate through photocatalytic oxidation to give Se(VI), which was reduced to Se(IV). Selenium hydride was generated from Se(IV) through reduction with sodium borohydride and then preconcentrated using cryotrapping. The cryotrapped hydride was evaporated and carried to a reaction chamber by a stream of helium, where it produced GPCL as a result of ozonation. The method exhibits a wide linear calibration range (from 0.5?μg?L?1 to 1.0?mg?L?1) with a detection limit of 0.12?μg?L?1 (for n?=?11), and a relative standard deviation of 3.90?% (at n?=?11) at 5.0?μg?L?1 level of selenium. The method was applied to the determination of inorganic selenium in water samples and gave satisfactory results.
Figure
A GPCL detection system is developed for the determination of inorganic selenium in water samples. By using analytical technique in this figure, such as derivatization, UV/ S2O 8 2- decomposition, stopped-flow injection and cryotrapping, the system can separate and preconcentrate the analyte from the matrix, then produce GPCL as a result of ozonation. The method was simple, sensitive with low-cost instrumentation.  相似文献   

11.
We have synthesized the near-infrared water-soluble conjugated polymer poly[2,5-di(propyloxysulfonate)-1,4-phenylene-ethynylene-9,10-anthrylene (referred to as PPEASO3). Its fluorescence (at wavelengths between 650 and 800?nm following photoexcitation at 550?nm) is efficiently quenched by Cu(II) ions, while other physiologically relevant metal ions do not cause significant quenching at the same concentrations. Under optimum conditions, fluorescence intensity is inversely proportional to the concentration of Cu (II). The calibration curve displays two linear regions over the range of 0–3.2?×?10?7 mol L?1 and 3.2?×?10?7 mol L?1 to 1.0?×?10?4 mol L?1 of Cu(II), respectively. The long-wavelength excitation and emission can substantially reduce interferences by the autofluorescence and light scattering of biological matter under UV excitation. The method was successfully applied to the determination of Cu(II) in synthetic and tea samples.
Figure
Highly sensitive fluorescent sensor with low background interference was successfully applied to the determination of Cu (II) in synthetic and real samples, based on amplified fluorescence quenching of a water-soluble NIR emitting conjugated polymer.  相似文献   

12.
We report on a novel method for on-line cloud point extraction (CPE) for preconcentration of cadmium ions. It is based on electromagnetic induction-assisted heating (EMIH) of iron particles in a packed bed contained in a quartz tube that acts as an on-line CPE enrichment column. The cadmium complex of 1-(2-pyridylazo)-2-naphthol is quantitatively retained by the column under the cloud point temperature with the help of EMIH. The column was then eluted with alcoholic borax buffer at room temperature and on-line coupled to FAAS. Under optimum conditions, the limit of detection (3 sb/b) and limit of quantification (10 sb/b) are 0.21 μg?L?1 and 0.70 μg?L?1 of Cd(II), respectively, and the relative standard deviation is 3.8 % (for n?=?8; at 20 ng?mL?1). An enhancement factor of 76 is typically achieved. The correlation coefficient of the calibration graph using the present method was 0.9986. The method was successfully applied to determine Cd(II) in water samples
Figure
An on-line cloud point extraction method was developed. Iron particles packed bed acts as an enrichment column. The cadmium complex of 1-(2-pyridylazo)-2-naphthol is quantitatively retained by the column under the cloud point temperature with the help of electromagnetic induction-assisted heating technique  相似文献   

13.
We have developed a solid phase extraction method for the determination of cadmium ions in aqueous samples. It is based on the adsorption of Cd(II) on alumina nanoparticles coated with sodium dodecyl sulfate and modified with a newly synthesized Schiff base. Analytical parameters such as pH value, amount of adsorbent, type and concentration of eluent, flow rates of the sample and eluent, sample volume and matrix effects were optimized. Desorption is accomplished with 2?mol?L?1 nitric acid. Cd(II) was then determined by flame atomic absorption spectrometry. The maximum enrichment factor is 75. Under the optimum experimental conditions, the detection limit is 0.14???g?L?1 in original solution. The adsorption capacity of the modified sorbent is 4.90?mg?g?1 for cadmium ions. The method was applied to the determination of trace quantities of Cd(II) in water, wastewater, and biological and food samples with satisfactory results.
Figure
Schematic representation of the loading L on the alumina nanoparticles  相似文献   

14.
A new sorbent was prepared by immobilization of 2,6-diaminopyridine on activated carbon and then used as a solid-phase extractant for trace Au(III), Pd(II) and Pt(IV) before their determination by ICP-AES. Effects of pH, the shaking time, the sample flow rate and volume, the elution condition and the potentially interfering ions were investigated. The optimum pH value is 1. The maximum static adsorption capacity for the three ions is 202.7, 38.5 and 30.1?mg?g?1, respectively. The adsorbed metal ions can be completely eluted by 2?mL of the eluent solution that contains 0.05?mol?L?1 HCl and 5% thiourea. Common other ions do not interfere. The detection limits (3??) are 0.16, 0.33 and 0.29?ng?mL?1, respectively. The relative standard deviation (RSD) was lower than 3.0% (n?=?8). The new sorbent was applied to the preconcentration of the three ions in ore and rock samples with satisfactory results.
Figure
Au(III), Pd(II), Pt(IV) are absorbed at pH 1. The maximum static adsorption capacity is 202.7, 38.5 and 30.1?mg?g?1. The eluent is 2?mL of the eluent solution that contains 0.05?mol?L?1 HCl and 5% thiourea. The relative standard deviation (RSD) was lower than 3.0% (n?=?8).  相似文献   

15.
We report on the synthesis and evaluation of aminated-CoFe2O4/SiO2 nanoparticles that can serve as a selective solid-phase sorbent for the extraction of cadmium ion. The nanoparticles consist of a magnetic CoFe2O4 core and an amino-modified silica shell. They can efficiently extract cadmium(II) ion and then can be isolated from the sample solution due to the magnetic nature of the core. The effects of the experimental conditions on the extraction process were optimized. Cadmium was then quantified by hydride generation atomic fluorescence spectrometry. The resulting calibration curve is linear in the concentration range of 0.01–10 μg?L?1, the instrumental detection limits (3σ) is 3.15 ng?L?1 and the relative standard deviation is 4.9 % at the 1.0 μg?L?1 level (for n?=?11). The enrichment factor is 50 (for 50 mL samples), and the adsorbent can be used for at least 45 cycles of preconcentration and elution. The method was applied to the determination of cadmium in environmental water samples, and successfully validated by analyzing two certified reference materials.
Figure
Magnetic solid-phase extraction coupled with hydride generation atomic fluorescence spectrometry for the determination of cadmium is described.  相似文献   

16.
Silver nanoparticles (Ag NPs) modified with sodium 2-mercaptoethanesulfonate (mesna) exhibit strong surface-enhanced Raman scattering (SERS). Their specific and strong interaction with heavy metal ions led to a label-free assay for Hg(II). The covalent bond formed between mercury and sulfur is stronger than the one between silver and sulfur and thus prevents the adsorption of mesna on the surface of Ag NPs. This results in a decrease of the intensity of SERS in the presence of Hg(II) ions. The Raman peak at 795?cm?1 can be used for quantification. The effect of the concentration of mesna, the concentration of sodium chloride, incubation time and pH value on SERS were optimized. Under the optimal conditions, the intensity of SERS decreases with increasing concentration of Hg(II). The decrease is linear in the 0.01 and 2?μmol L?1 concentration range, with a correlation coefficient (R2) of 0.996 and detection limit (S/N?=?3) is 0.0024?μmol L?1. The method was successfully applied to the determination of the Hg(II) in spiked water samples.
Figure
SERS spectra of mesna-Ag NPs system in the presence of Hg2+. Concentrations of Hg2+: (1) 0.1×10-7, (2) 1×10-7, (3) 3.5×10-7, (4) 5×10-7, (5) 12×10-7, (6) 20×10-7mol L-1  相似文献   

17.
We have developed a surface-enhanced Raman scattering (SERS) probe for the determination of mercury(II) using methimazole-functionalized and cyclodextrin-coated silver nanoparticles (AgNPs). These AgNPs in pH 10 solution containing sodium chloride exhibit strong SERS at 502 cm?1. Its intensity strongly decreases in the presence of Hg(II). This effect serves as the basis for a new method for the rapid, fast and selective determination of trace Hg(II). The analytical range is from 0.50 μg L?1 to 150 μg L?1, and the limit of detection is 0.10 μg L?1. The influence of 11 metal ions commonly encountered in environmental water samples was found to be quite small. The method was applied to the determination of Hg(II) in spiked water samples and gave recoveries ranging from 98.5 to 105.2 % and with relative standard deviations of <3.5 % (n?=?5). The total analysis time is <10 min for a single sample.
Figure
A high-sensitive SERS probe for the determination of Hg2+ using methimazole-functionalized cyclodextrin-protected AgNPs was designed. The limit of detection is 0.10 μg L?1.  相似文献   

18.
We report on a carbon paste electrode that was modified with a binuclear manganese(II) complex by the drop-coating method. A study on the mechanism of the electro-oxidation of tryptophan (Trp) at this electrode indicated that it enables Trp to be determined with good sensitivity and selectivity. Second-order derivative linear sweep voltammetry at pH 4.1 revealed that a sensitive anodic peak appears at 812?mV (vs. SCE) whose current is proportional to the concentration of Trp in the concentration range from 0.1 to 1.0???mol?L?1 and 1.0 to 80???mol?L?1, with a detection limit (S/N?=?3) of 0.08???mol?L?1 (60?s of accumulation). The method was applied to the determination of Trp in amino acid injection solutions with satisfactory results.
Figure
The electrochemical behavior of tryptophan at a carbon paste electrode modified with a binuclear manganese(II) complex Mn2(phen)2(p-MBA)4(H2O) was investigated. The modified electrode showed high electrocatalytic activity toward the oxidation of tryptophan and the peak current increases linearly with tryptophan concentration in the range of 0.1 to 80???mol L?1.  相似文献   

19.
Rapidly synergistic cloud point extraction (RS-CPE) was coupled with thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) to result in new CPE patterns and accelerated (1?min) protocols. It is demonstrated, for the case of copper (II) ion, that TS-FF-AAS improves the sampling efficiency and the sensitivity of FAAS determinations. Problems of nebulization associated with previous methods based on the coupling of FAAS and RS-CPE are overcome. TS-FF-AAS also improves sensitivity and gives a limit of detection for copper of 0.20?μg?L-1, which is better by a factor of 32. Compared to direct FAAS, the factor is 114.
Figure
The coupling of RS-CPE with TS-FF-AAS for copper detection  相似文献   

20.
We have developed a simple method for the microextraction of the carbamate pesticides carbofuran, pirimicarb, and carbaryl. It is termed ionic liquid magnetic bar microextraction (ILMB-ME) and based on an ionic liquid deposited on a magnetic stirrer bar placed in a sealed short PCR tube into which microholes where pinned. When placed in a vial containing the aqueous sample solution, the ILMB tumbles freely in the aqueous solution and the carbamates are extracted into the ionic liquid phase which then was determined by HPLC. The enrichment factors for carbofuran, pirimicarb, and carbaryl are 107, 94, 95, respectively. The limits of detection, calculated as three times the signal-to-noise ratio (S/N), are 1.4?μg?L?1 for carbofuran, 3.4?μg?L?1 for pirimicarb, and 1.7?μg?L?1 for carbaryl. The repeatability, carried out by extracting water samples spiked with carbamate levels of 200?μg?L?1, yielded relative standard deviations between 2.9 and 6.0?%, (for n?=?5). The recoveries of all the three fungicides from tap, lake and rain water samples at spiking levels of 5 and 50?μg?L?1 are in the range from 86 to 98?%, and from 80 to 96?%, respectively. We conclude that this is a simple, practical and efficient method for the determination of fungicide residues in real water samples.
Figure
?  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号