共查询到20条相似文献,搜索用时 0 毫秒
1.
从迈克耳孙干涉仪到光学相干层析术 总被引:1,自引:0,他引:1
介绍了迈克耳孙干涉仪在物理学发展史上的重要作用及生物医学成像技术的发展状况.从迈克耳孙干涉仪的发展过程出发,讨论了光学相干层析术的原理、特性及其在生物医学成像、物理学、材料科学中的应用,并将频谱光学相干层析术与傅里叶变换光谱术作了比较,最后讨论了它在教学上的意义. 相似文献
2.
3.
4.
本文报道了一种基于拉锥结构的全光纤型内窥光学相干层析成像探针. 基于大纤芯多模光纤的低光束发散特性, 使用大纤芯多模光纤代替透镜作为成像元件, 并在单模光纤与大纤芯多模光纤之间引入过渡拉锥段以减少插入损耗. 首先利用光学仿真软件(Rsoft)确定探针的最佳结构, 然后通过拉锥、切割以及熔接工艺实现探针制作, 并对探针的出射光束特性与插入损耗进行测量, 最后将该探针与扫频光学相干层析成像主系统联机, 对人体指尖皮肤及鸡气管壁组织进行成像. 该探针直径为250 μm, 不锈钢保护管外径为325 μm, 硬端长度1 cm, 插入损耗约为0.3 dB, 空气中有效成像范围达800 μm. 该探针为内窥光学相干层析成像技术在心血管疾病的应用提供了高紧凑度、高传输效率与高灵活性的选择. 相似文献
5.
针对频域光学相干层析系统成像过程中产生的图像噪声,提出了一种干涉光谱解耦的方法。该方法通过消除干涉光谱中的直流项和自相关项,实现对图像去噪。利用白光作为光源,对聚苯乙烯单层薄膜进行成像实验,得到薄膜的一维深度图像以及二维层析图像。由二维层析图像可以清晰的获取薄膜的内部微观结构及表面形貌信息。实验结果表明,该检测方法可有效消除薄膜的图像噪声,提高图像信噪比和对比度。 相似文献
6.
We investigated the use of optical coherence tomography (OCT) to measure several materials immersed in optical adhesives. The effects of variations in the concentration, physical characteristics, and thickness of the materials were studied, and these parameters were found to significantly affect the OCT measurement. The materials were selected for their distinct spectral properties in the infrared region. To ensure reliability, we acquired images using a scanning electron microscope after performing the semiconductor production process. We verified the feasibility of the application of OCT for defect inspection and product verification of touch-screen panels. 相似文献
7.
研制了一套采用旋转1/2波片无色散移相器进行移相操作的全场光学相干层析成像系统.该移相器能在宽光谱范围内无色散地获得8倍于1/2波片旋转角的移相量,能快速、方便地为各种移相算法提供所需的移相量.移相量实测结果表明:系统获得了8倍旋转角的移相量,提出的移相器结构正确.采用Hariharan移相算法对反射镜样品进行的成像实验表明系统具有较高的移相精度.最后进行的实物样品成像实验,检验了系统的有效性.
关键词:
全场光学相干层析成像
无色散移相器
旋转1/2波片 相似文献
8.
We report in this paper the development of a spectral-domain optical coherence vibration tomography (OCVT) using a broadband CCD-based spectrometer and a short-coherence white light source. We demonstrate that both the vibration amplitude and frequency can be quantified, in the frequency range 0-250 Hz, with an axial resolution of 1 μm. Furthermore, the inner structure (layer thickness) of a vibrating sample can also be quantified simultaneously. The developed OCVT is non-contact and noninvasive in nature, thus is ideal for real time and in situ monitoring of low-frequency micro-vibrations that have critical impacts on many high-precision manufacturing and engineering processes. 相似文献
9.
10.
鉴于不同生理病理状态下组织复折射率实部的变化不大,传统光学相干层析(OCT)成像技术在分子特异性识别上存在先天不足.为此,本文提出了基于受激辐射信号的OCT成像方法,可在实现传统散射成像的同时,实现基于受激辐射信号的分子成像.在超高分辨率谱域OCT系统的基础上,通过增设光谱分光与调制抽运光支路,建立了基于单宽谱光源的抽运探测谱域OCT系统,详细推导了调制抽运下受激辐射信号的获取与成像公式.利用搭建的抽运探测谱域OCT系统,实现了瞬态受激辐射信号的相干探测.基于同时获取的受激辐射OCT信号和传统OCT信号,成功重构了氮化物粉末构建样品的基于受激辐射信号的分子对比OCT图像. 相似文献
11.
Optical coherence tomography (OCT) is a noninvasive technique that provides micrometer-scale imaging of tissue. As most biological tissues are considered turbid, it causes attenuation of the OCT signal and limits the depth penetration. Although a few algorithms had been developed to compensate the attenuation, almost all of them need to extract the scattering parameters before doing the compensation procedure. Because the real biological samples are anisotropic and multilayer-like structure, it is not time-efficient to model and solve these scattering parameters. This paper introduces a new method to compensate the OCT signal attenuation in depth. By analyzing the input signal, a compensation function is adaptively derived for each A-scan line, which can be used effectively to compensate the energy loss in the large sections and enhance the details in the deep, dark-like areas. Three bio-samples, a piece of onion, a Poecilia Wingei fish and a piece of rabbit abdominal aorta, were used to test our method. OCT images obtained by a swept-source OCT system were processed by the proposed method. Results show the visualization of structures in OCT images has been evidently improved, especially in deep region. 相似文献
12.
报道了一种新型的专用于光学相干层析系统的输出光谱为准高斯型的宽带超荧光光纤光源.该光源采用掺饵光纤作为增益介质.其关键技术是在抽运源的输出端增加了光耦合器,并在光源输出端插入多级长周期光纤光栅对铒离子的自发光谱进行调制和整形;同时采用光控器和温控器来控制抽运源的输出以提高光源输出功率的稳定性.该光源的中心波长为1.57μm,输出光谱的3dB带宽大于75nm,输出功率为27mW.实验结果表明,该光源输出光谱的自相关函数的旁瓣峰被大大削弱,可以满足光学相干层析系统的应用.
关键词:
光学相干层析术
超荧光光纤光源
长周期光纤光栅
光耦合器 相似文献
13.
I. Abdulhalim 《Annalen der Physik》2012,524(12):787-804
Low‐coherence optical microscopy or optical coherence microscopy uses light with short coherence length. The well‐known case is: “white‐light interferometry”, which became recently more known as: “optical coherence tomography”. However, when lenses and microscope objectives are used to create interferometric images, in what is known classically as “interference microscopy” or today as “full‐field optical coherence tomography” the spatial coherence starts to play a critical role. In this article the coherence effects in low‐coherence optical microscopy are reviewed. As this technology is becoming increasingly publicized due to its importance in three‐dimensional imaging, particularly of scattering biological media and optical metrology, the understanding of the fundamental physics behind it is essential. The interplay between longitudinal spatial coherence and temporal coherence and the effects associated with them are discussed in detail particularly when high numerical apertures are used. An important conclusion of this study is that a high‐contrast, high‐resolution system for imaging of multilayered samples is the one that uses narrowband illumination and high‐NA objectives with an index‐matching fluid. Such a system, when combined with frequency‐domain operation, can reveal nearly real‐time three‐dimensional images, and is thus competitive with confocal microscopy. 相似文献
14.
提出了一种基于谱域相位分辨光学相干层析的纳米级表面形貌成像方法,由干涉光谱计算样品相邻两点的相位差,得到样品表面相位差分图,经过积分,重建样品表面形貌的定量分布.当相邻两点相位差的绝对值小于π,不产生相位包裹,避免了目前的干涉法相位解包裹存在的问题,将干涉法相邻两点相位差绝对值的限制条件由目前的π扩大到2π,提高了干涉法表面形貌成像的适用范围.参考面和样品置于同一平台之上,消除环境干扰及系统振动的影响,噪声幅度小于0.3 nm.通过对光学分辨率片及表面粗糙度标准样板的表面形貌成像,对本方法进行了验证,系统的轴向分辨率优于1 nm. 相似文献
15.
本文报道了一种超高分辨率谱域光学相干层析成像(SD-OCT)系统. 该系统基于超连续谱激光光源并截取部分光谱作为宽带光源, 其中心波长为665 nm, 光谱半高全宽(FWHM) 230 nm. 系统轴向分辨率0.9 μm, 轴向扫描速率28600行/秒, 横向分辨率3.9 μm, 横向视场1 mm, 最大成像深度0.6 mm(空气中). 利用研制的超高分辨率SD-OCT系统, 对不同型号的工业砂纸精细结构进行了成像, 并与普通SD-OCT的成像结果进行对比, 充分展示了研制系统在材料无损检测中优势. 相似文献
16.
High performance wavelength-swept laser with mode-locking technique for optical coherence tomography
We demonstrate a Fourier-domain mode-locked wavelength-swept laser that uses a polygon-based narrowband optical scanning filter and a high-efficiency semiconductor optical amplifier. Peak and average output powers of 98 mW and 71 mW have been achieved, respectively, without an external amplifier, while the wavelength was swept continuously from 1247 nm to 1360 nm. A unidirectional wavelength sweeping rate of 7452 nm/ms (65.95 kHz repetition rate) was achieved by using a 72 facet polygon scanner with a rotation rate of 916 revolutions per second. The instantaneous linewidth of this laser is 0.09 nm, which corresponds to a coherence length of 16 mm. This laser is most suitable for optical coherence tomography applications. 相似文献
17.
谱域光学相干层析(spectral domain optical coherence tomography, 简记为SD-OCT)系统的轴向点扩散函数(point spread function, 简记为PSF)并不具备空不变特性,无法直接应用于解卷积运算.为实现SD-OCT系统成像质量基于解卷积算法的优化,本文采用数值校正后的轴向扫描信号和轴向有效PSF来实施基于Lucy-Richardson算法的解卷积运算,进而实现了SD-OCT系统中图像质量尤其是轴向分辨率的改善.本文理论分析了SD-OCT系统中导致轴向有效PSF随成像深度增大而下降和图像模糊的因素,阐述了利用解卷积算法实现图像质量优化的过程,基于建立的SD-OCT系统实施了不同成像深度位置处PSF的标定,并利用离散轴向位置处PSF的峰值拟合了轴向有效PSF的调制函数.利用调制函数对所有轴向扫描信号进行数值校正,然后根据轴向有效PSF进行解卷积算法.典型样品的解卷积图像重建结果表明,提出的解卷积方法能有效提高系统的轴向分辨率,同时有效抑制系统灵敏度随成像深度增大而下降的趋势.
关键词:
谱域光学相干层析
Lucy-Richardson解卷积
有效点扩散函数 相似文献
18.
谱域光学相干层析(spectral domain optical coherence tomography, 简记为SD-OCT)系统的轴向点扩散函数(point spread function, 简记为PSF)并不具备空不变特性,无法直接应用于解卷积运算.为实现SD-OCT系统成像质量基于解卷积算法的优化,本文采用数值校正后的轴向扫描信号和轴向有效PSF来实施基于Lucy-Richardson算法的解卷积运算,进而实现了SD-OCT系统中图像质量尤其是轴向分辨率的改善.本文理论分析了SD-OCT系统中导致轴向有效PSF随成像深度增大而下降和图像模糊的因素,阐述了利用解卷积算法实现图像质量优化的过程,基于建立的SD-OCT系统实施了不同成像深度位置处PSF的标定,并利用离散轴向位置处PSF的峰值拟合了轴向有效PSF的调制函数.利用调制函数对所有轴向扫描信号进行数值校正,然后根据轴向有效PSF进行解卷积算法.典型样品的解卷积图像重建结果表明,提出的解卷积方法能有效提高系统的轴向分辨率,同时有效抑制系统灵敏度随成像深度增大而下降的趋势. 相似文献
19.
In the present cosmetic market, the skin image obtained from a hand-held camera is two-dimensional (2-D). Due to insufficient
penetration, only the skin surface can be detected, and thus phenomena in the dermis cannot be observed. To take the place
of the conventional 2D camera, a new hand-held imaging system is proposed for three-dimensional (3-D) skin imaging. Featuring
non-invasiveness, optical coherence tomography (OCT) has become one of the popular medical imaging techniques. The dermal
images shown in OCT-related reports were mainly single-colored because of the use of a monotonic light source. With three
original-colored beams applied in OCT, a full-colored image can be derived for dermatology. The penetration depth of the system
ranges from 0.43 to 0.78 mm, sufficient for imaging of main tissues in the dermis. Colorful and non-invasive perspectives
of deep dermal structure help to advance skin science, dermatology and cosmetology. 相似文献
20.
提出了基于互相关的多普勒OCT(correlated Doppler optical coherence tomography, CD-OCT)方法, 能够有效的抑制噪声, 实现低信噪比条件下的流速探测. 对CD-OCT算法进行了详细的推导, 分析了噪声的相关性对该算法结果的影响, 最后基于谱域和时域联合探测方法(joint spectral and time domain optical coherence tomography, STD-OCT)以及CD-OCT算法的对比实验证明了该算法能够进一步实现信噪比的提高, 使测量的结果更为稳定. 相似文献