首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 26 毫秒
1.
A simple and sensitive gas chromatography–electron ionization–mass spectrometry (GC‐EI‐MS) method using dried plasma spot testing cards was developed for determination of valproic acid and gabapentin concentrations in human plasma from patients receiving in‐home medical care. We have proposed that a simple, easy and dry sampling method is suitable for in‐home medical patients for therapeutic drug monitoring. Therefore, in the present study, we used recently developed commercially available easy handling cards: Whatman FTA DMPK‐A and Bond Elut DMS. In‐home medical care patients can collect plasma using these simple kits. The spots of plasma on the cards were extracted into methanol and then evaporated to dryness. The residues were trimethylsilylated using N‐methyl‐N‐trimethylsilyltrifluoroacetamide. For GC‐EI‐MS analysis, the calibration curves on both cards were linear from 10 to 200 µg/mL for valproic acid, and from 0.5 to 10 µg/mL for gabapentin. Intra‐ and interday precisions in plasma were both ≤13.0% (coefficient of variation), and the accuracy was between 87.9 and 112% for both cards within the calibration curves. The limits of quantification were 10 µg/mL for valproic acid and 0.5 µg/mL for gabapentin on both cards. We believe that the present method will be useful for in‐home medical care. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

2.
In this article, a step‐by‐step optimization procedure for improving analyte response with implementation of experimental design is described. Zwitterionic antiepileptics, namely vigabatrin, pregabalin and gabapentin, were chosen as model compounds to undergo chloroformate‐mediated derivatization followed by liquid chromatography coupled with tandem mass spectrometry (LC‐MS/MS) analysis. Application of a planned stepwise optimization procedure allowed responses of analytes, expressed as areas and signal‐to‐noise ratios, to be improved, enabling achievement of lower limit of detection values. Results from the current study demonstrate that optimization of parameters such as scan time, geometry of ion source, sheath and auxiliary gas pressure, capillary temperature, collision pressure and mobile phase composition can have a positive impact on sensitivity of LC‐MS/MS methods. Optimization of LC and MS parameters led to a total increment of 53.9%, 83.3% and 95.7% in areas of derivatized vigabatrin, pregabalin and gabapentin, respectively, while for signal‐to‐noise values, an improvement of 140.0%, 93.6% and 124.0% was achieved, compared to autotune settings. After defining the final optimal conditions, a time‐segmented method was validated for the determination of mentioned drugs in plasma. The method proved to be accurate and precise with excellent linearity for the tested concentration range (40.0 ng ml?1–10.0 × 103 ng ml?1). Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
A simple, sensitive and rapid liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) method was developed and validated for the quantification of valproic acid, an antiepileptic drug, in human plasma using benzoic acid as internal standard (IS). Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the single ion monitoring mode using the respective [M-H]- ions, m/z 143 for valproic acid and m/z 121 for the IS. The assay exhibited a linear dynamic range of 0.5-60 microg/mL for valproic acid in human plasma. The lower limit of quantification was 500 ng/mL with a relative standard deviation of less than 10%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The average absolute recoveries of valproic acid and the IS from spiked plasma samples were 96.1+/-4.2 and 95.6+/-2.7%, respectively. A run time of 4.5 min for each sample made it possible to analyze more than 250 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability and bioequivalence studies.  相似文献   

4.
A liquid chromatographic tandem mass spectrometric (LC-MS/MS) assay was developed and validated to determine valproic acid in human plasma. The method involved a solid-phase extraction of valproic acid and betamethasone valerate, an internal standard, from plasma and detection using an LC-MS/MS system with electrospray ionization source in negative ion mode. Separation was achieved within 3 min on a non-porous silica column with mobile phase containing ammonium acetate and methanol. Multiple reaction monitoring was utilized for detection monitoring at 142.89-142.89 for valproic acid and 457.21-457.21 for the internal standard. The calibration curve for valproic acid was linear over the range of 0.5-150 microg/mL. The limit of detection was 0.17 microg/mL and the lower limit of quantification was 0.5 microg/mL, when 0.2 mL plasma was used for extraction. The percentage coefficient of validation for accuracy and precision (inter- and intra-day) for this method was less than 9.5% with recovery ranging from 82.3 to 86.9% for valproic acid.  相似文献   

5.
A rapid, sensitive and specific method for quantification of methoxsalen in human plasma using metaxalone as the internal standard is presented. An Applied Biosystems Sciex API 3200 triple quadrupole mass spectrometer in multiple reaction monitoring mode, using TurboIonSpray in the positive ion mode was used. Simple solid phase extraction was followed by C18 reverse phase chromatography and tandem mass spectrometry using metaxalone as the internal standard. The mean recovery for methoxsalen was 90.0% with a lower limit of quantification of 1.0 ng mL?1. This validated assay method makes use of the sensitivity and selectivity of tandem mass spectrometry detection to allow for a more rapid and selective method for the determination of methoxsalen in human plasma.  相似文献   

6.
A simple, sensitive, and rapid analytical method has been developed and validated for the extraction and quantification of valproic acid and its main metabolite (3-heptanone) in human plasma. Initially, the proteins of plasma were precipitated with trifluoroacetic acid. Then a very small volume of a water-immiscible extractant and acetonitrile was mixed and rapidly injected into the pre-treated plasma sample. For further turbidity (dispersion of the extractant into sample solution), the cloudy solution was vortexed. After centrifugation, the settled phase was injected into gas chromatography-flame ionization detection. The effective parameters, such as type and volume of extraction and disperser solvents, vortex time, and pH were studied and optimized. The limits of detection of valproic acid and 3-heptanone were obtained, 0.065 and 0.015 mg L?1, respectively. An acceptable precision was obtained for a concentration of 2 mg L?1 of each analyte (relative standard deviation?≤?8%). The average absolute recoveries (n?=?3) of valproic acid and 3-heptanone were 52?±?2 and 42?±?1%, respectively. The validated method has been successfully used in analysis of the analytes in human plasma samples.  相似文献   

7.
A rapid, simple and sensitive, liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed and validated for simultaneous determination of bergenin, chlorogenic acid and four flavonoids in a QingGanSanJie preparation in rat plasma. Puerarin was selected as the internal standard (IS). Plasma samples were precipitated with methanol and separated with a reverse phase Agilent Poroshell 120 EC‐C18 column using a gradient mobile phase of methanol–water containing 0.1% formic acid (v/v). A triple quadruple mass spectrometer was used for quantification (limit of detection 0.36–5.55 ng/mL). Intra‐day and inter‐day precisions were within 15% and the average extraction recoveries ranged from 85 to 115% for each analyte. The method allowed simultaneous quantification for the first time of the pharmacokinetics of bergenin, chlorogenic acid and four flavonoids after intragastric administration of a QingGanSanJie extract in Sprague–Dawley rats. It was found that bergenin and chlorogenic acid had typical extravascular administration concentration–time curves; flavonoids had a bimodal distribution improving bioavailability and extending the pharmacodynamics period. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

8.
顶空气相色谱-质谱法测定婴幼儿食品中的呋喃   总被引:2,自引:0,他引:2  
刘平  薛颖  金庆中  徐筠  张正  吴国华 《色谱》2008,26(1):35-38
通过顶空装置将样品中的呋喃提取出来,以D4-呋喃作为内标物,HP-PLOT Q石英毛细管柱作为分析柱,采用气相色谱分离,质谱定性定量,建立了婴幼儿食品中呋喃的顶空气相色谱-质谱联用分析方法。方法的低浓度工作曲线的线性范围为10~70 ng,高浓度工作曲线的线性范围为50.0~400.0 ng,两条曲线的相关系数均为0.997。方法的定性检出限(S/N≥3)为3.8 ng/g,定量检出限(S/N≥10)为10.0 ng/g。不同基底样品中高低添加浓度的加标回收率为90.0%~98.4%,相对标准偏差均小于10%。  相似文献   

9.
A method for the identification and quantification of residues of the antibiotic chloramphenicol was developed and validated. The method is based on combined gas chromatography-mass spectrometry with negative-ion chemical ionization and the use of [37Cl2]chloramphenicol as an internal standard. A set of identification criteria, in accordance with guidelines of the European Community, is described. For urine, muscle and eggs limits of detection and quantification of 0.1 μg kg?1 are obtained. The method shows good repeatability and reproducibility. Results for urine were compared with those obtained with a radioimmunochemical procedure and an enzyme immunoassay (Quik-Card). Screening with an immunochemical procedure followed by confirmation with gas chromatography-mass spectrometry was found to be an effective strategy for monitoring residues of chloramphenicol in biological matrices.  相似文献   

10.
A simple, reliable and rapid ultra‐performance liquid chromatography–tandem mass spectrometry method was developed and validated for the simultaneous quantification of four secoiridoid (gentiopicroside, swertiamarin, sweroside) and iridoid glycosides (loganic acid), the bio‐active ingredients in rat plasma. After liquid–liquid extraction, chromatographic separation was accomplished on a Shim‐pack XR‐ODS column with a mobile phase consisting of methanol and 0.1% formic acid in water. A triple quadrupole tandem mass spectrometry equipped with an electrospray ionization source was used as detector operating both in positive and negative ionization mode and operated by multiple‐reaction monitoring scanning. The lower limits of quantitation were 0.25–30 ng/mL for all the analytes. Both intra‐day and inter‐day precision and accuracy of analytes were well within acceptance criteria (±15%). The mean extraction recoveries of analytes and internal standard (amygdalin) from rat plasma were all >71.4%. The validated method was successfully applied to a comparative pharmacokinetic study of four analytes in rat plasma between normal and arthritic rats after oral administration of Huo Luo Xiao Ling Dan and Gentiana macrophylla extract, respectively. Results showed significant differences in pharmacokinetic properties of the analytes among the different groups. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

11.
Chae  Yoon-Jee  Koo  Tae-Sung  Lee  Kyeong-Ryoon 《Chromatographia》2012,75(19):1117-1128

A liquid chromatography-mass spectrometry (LC-MS) assay was developed and validated for the quantification of lurasidone, an atypical antipsychotic drug, in rat plasma, bile, and urine. Rat plasma, bile, or urine samples were processed by liquid–liquid extraction and injected onto an LC-MS system for the quantification of lurasidone and ziprasidone (an internal standard). Lurasidone and ziprasidone were separated from endogenous substances using a Gemini C6-Phenyl column with mixture of acetonitrile and 0.1 % formic acid (80:20, v/v) as the mobile phase. Quantification was performed using the selected ion monitoring mode at m/z 493 for lurasidone and m/z 413 for the IS. The detector response was specific and linear for lurasidone in the concentration range 5–5,000 ng mL−1 The intra- and inter-day accuracy and precision of the method were determined to be within the acceptable criteria for assay validation guidelines. In addition, lurasidone was stable under a variety of processing and handling conditions. Lurasidone concentrations could be readily measured in rat plasma, bile, and urine samples up to 24 h after an intravenous or oral administration, suggesting that the assay can be used in pharmacokinetic studies of lurasidone in rats.

  相似文献   

12.
Bilal Yilmaz  Sakir Arslan 《Talanta》2009,80(1):346-8122
A sensitive and efficient method was developed for determination of metoprolol in human plasma by gas chromatography-mass spectrometry (GC-MS). Metoprolol and atenolol (internal standard, IS) were extracted from human plasma with a mixture of ethylacetate and diethylether at basic pH with liquid-liquid extraction. Calibration curves were linear over the concentration range 15-500 ng/ml. Intra- and inter-day precision values for metoprolol in human plasma were less than 6.4, and accuracy (relative error) was better than 8.8%. The analytical recovery of metoprolol from human plasma averaged 91.20%. The limits of detection (LOD) and quantification (LOQ) of metoprolol were 5.0 and 15 ng/ml, respectively. Also the developed and validated GC-MS method was successfully applied to three patients with hypertension who had been given an oral tablet of 100 mg metoprolol.  相似文献   

13.
In this research, we developed and validated a liquid chromatography coupled to mass spectrometry (LC–QToF–MS) method for simultaneous quantification of the anti-tuberculosis drugs ethambutol, isoniazid, pyrazinamide and rifampicin in human plasma. Plasma samples spiked with cimetidine (internal standard) were extracted using protein precipitation with acetonitrile containing 1% formic acid. Separation was performed using a C18 column under flow gradient conditions with water and acetonitrile, both containing 5 mm ammonium formate and 0.1% formic acid. The method was validated according to the ANVISA and US Food and Drug Administration guidelines for bioanalytical method validation. The calibration curve was linear over a concentration range of 0.2–5 μg ml−1 for ethambutol, 0.2–7.5 μg ml−1 for isoniazid, 1–40 μg ml−1 for pyrazinamide and 0.25–2 μg ml−1 for rifampicin, all with adequate precision and accuracy. The method was reproducible, selective and free of carryover and matrix effects. The validated LC–QToF–MS method was successfully applied to real samples and shown to be applicable to future therapeutic and pharmacokinetic monitoring studies.  相似文献   

14.
A two-dimensional (2D) gas chromatography/electron impact-mass spectrometry (GC/EI-MS) method for simultaneous quantification of Delta(9)-tetrahydrocannabinol (THC), 11-hydroxy-Delta(9)-tetrahydrocannabinol (11-OH-THC), and 11-nor-Delta(9)-tetrahydrocannabinol-9-carboxylic acid (THCCOOH) in human plasma was developed and validated. The method employs 2D capillary GC and cryofocusing for enhanced resolution and sensitivity. THC, 11-OH-THC, and THCCOOH were extracted by precipitation with acetonitrile followed by solid-phase extraction. GC separation of trimethylsilyl derivatives of analytes was accomplished with two capillary columns in series coupled via a pneumatic Deans switch system. Detection and quantification were accomplished with a bench-top single quadrupole mass spectrometer operated in electron impact-selected ion monitoring mode. Limits of quantification (LOQ) were 0.125, 0.25 and 0.125 ng/mL for THC, 11-OH-THC, and THCCOOH, respectively. Accuracy ranged from 86.0 to 113.0% for all analytes. Intra- and inter-assay precision, as percent relative standard deviation, was less than 14.1% for THC, 11-OH-THC, and THCCOOH. The method was successfully applied to quantification of THC and its 11-OH-THC and THCCOOH metabolites in plasma specimens following controlled administration of THC.  相似文献   

15.
A method for the quantification of phenylalanine in whole blood and plasma by isotope dilution gas chromatography-mass spectrometry is presented. The use of an uncommon derivative allows a simple extraction procedure and the most basic mass spectrometer. The relative standard deviation was found to be 1.3% within-batch and 2.1% between-batch under optimum conditions, and the detection limit was found to be 7 pmol injected. The ruggedness of the procedure and sample handling conditions were also examined.  相似文献   

16.
A sensitive and specific method was developed and validated for the quantitation of one major metabolite of genipin in rats plasma. The major metabolite was isolated from rat bile via semi‐preparative HPLC technology and its chemical structure was identified as genipin‐1‐o‐glucuronic acid (GNP‐GLU), which was for the first time used as a standard compound for quantitative analysis in rat plasma after administration of genipin. The application of high‐performance liquid chromatography–tandem mass spectrometry in negative mode in multiple reaction monitoring mode was investigated. Chromatographic separation was achieved on an Eclipse XDB‐C18 column using a mobile phase consisting of water with 0.1% formic acid (A)–acetonitrile (B). The limit of detecation was 0.214 ng/mL and the lower limit of quantification was 0.706 ng/mL. The calibration curve was linear from 1.27 to 3810 ng/mL for plasma samples, with a correlation coefficient of 0.9924. The intra‐ and inter‐day precisions and accuracy were all within 15%. The recoveries of GNP‐GLU and puerarin were above 90.0 and 76.2%, respectively. The highly sensitive method was successfully applied to estimate pharmacokinetic parameters of GNP‐GLU following oral and intravenous administration of genipin to rats. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

17.
采用固相萃取-气相色谱-质谱联用技术,建立了水体中9种药品及个人护理用品(水杨酸、萘普生、布洛芬、对乙酰氨基酚、降固醇酸、三氯生、双氯酚酸、酮洛芬和双酚A)的定量分析方法。水样品经稀盐酸调节至pH=3后,采用Oasis HLB固相萃取小柱进行富集净化;选用三甲基氢氧化硫(TMSH)为衍生化试剂,在常温条件下对目标物进行快速甲基化;以气相色谱-质谱法选择离子监测模式(GC-MS-SIM)进行检测,由2,4,5-涕丙酸为内标进行定量分析。本实验分别对固相萃取和衍生化等前处理条件进行了系统的研究。在优化的实验条件下,方法的回收率为50.7~115.4%,相对标准偏差均不高于10%,检出限为0.03~0.30 μg/L,定量限为0.15~1.50 μg/L。利用该方法对东莞市某农田灌溉水进行了分析,4种目标物在样品中有检出,最大质量浓度范围为0.176~0.998 μg/L。结果表明该方法操作简便,灵敏可靠。  相似文献   

18.
A rapid, simple and specific method for estimation of anastrazole in human plasma was validated using letrozole as internal standard. The analyte and internal standard were extracted from plasma using simple solid‐phase extraction. The compound were separated on a reverse‐phase column with an isocratic mobile phase consisting of 0.1% formic acid in water and acetonitrile (12 : 88, v/v) and detected by tandem mass spectrometry in positive ion mode. The ion transitions recorded in multiple reaction monitoring mode were m/z 294.1 → 225.1 for anastrazole and m/z 286.1 → 217.1 for internal standard. Linearity in plasma was observed over the concentration range 0.3–30 ng/mL for anastrazole. The mean recovery for anastrazole was 83.7% with a lower limit of quantification of 0.3 ng/mL. The coefficient of variation of the assay was less than 6.8% and the accuracy was 96.1–102.2%. The validated method was applied to a bioequivalence study of 1 mg anastrazole tablet in healthy human volunteers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

19.
In the present study, the solid–liquid extraction with low temperature purification was validated for the determination of 16 polycyclic aromatic hydrocarbons from sewage sludge by gas chromatography-mass spectrometry. Recoveries ranged 70–114% for naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo[a]anthracene and chrysene, while the compounds benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, indeno[1,2,3-cd]pyrene, dibenzo[a,h]anthracene and benzo[g,h,i]perylene showed recoveries of between 40 and 70%. The relative standard deviation was less than 13% for all of the compounds. Negative matrix effect was observed on the 10 compounds with less retention time in the chromatographic analysis and positive matrix effect noticed on the others. The limits of quantification were from 2 to 20 μg kg?1, about 30 times less than the maximum residue limit allowed in sludge by the European Union. The validated method produced quantification of 11 PAHs in one sludge sample at concentrations ranging 20–2000 μg kg?1.  相似文献   

20.
In this study, a simple, rapid, and sensitive method was developed and validated for the quantification of valproic acid (VPA), an antiepileptic drug, in human plasma, which was based on water-phase derivatization followed by headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS). In the proposed method, VPA in plasma was rapidly derivatized with a mixture of isobutyl chloroformate, ethanol and pyridine under mild conditions (room temperature, aqueous medium), and the VPA ethyl ester formed was headspace-extracted and simultaneously concentrated using the SPME technique. Finally, the analyte extracted on SPME fiber was analyzed by GC/MS. The experimental parameters and method validations were studied. The optimal conditions were obtained: PDMS fiber, stirring rate of 1100 rpm, sample temperature of 80 degrees C, extraction time of 20 min, NaCl concentration of 30%. The proposed method had a limit of quantification (0.3 microg/mL), good recovery (89-97%) and precision (RSD value less than 10%). Because the proposed method combined a rapid water-phase derivatization with a fast, simple and solvent-free sample extraction and concentration technique of SPME, the sample preparation time was less than 25 min. This much shortens the whole analysis time of VPA in plasma. The validated method has been successfully used to analyze VPA in human plasma samples for application in pharmacokinetic studies. All these results show that water-phase derivatization followed by HS-SPME and GC/MS is an alternative and powerful method for fast determination of VPA in biological fluids.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号