首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Ultrasound-assisted dispersive liquid–liquid microextraction coupled with high-performance liquid chromatography-fluorescence detection was used for the extraction and determination of three biogenic amines including octopamine, tyramine and phenethylamine in rice wine samples. Fluorescence probe 2,6-dimethyl-4-quinolinecarboxylic acid N-hydroxysuccinimide ester was applied for derivatization of biogenic amines. Acetonitrile and 1-octanol were used as disperser solvent and extraction solvent, respectively. Extraction conditions including the type of extraction solvent, the volume of extraction solvent, ultrasonication time and centrifuging time were optimized. After extraction and centrifuging, analyte was injected rapidly into high-performance liquid chromatography and then detected with fluorescence. The calibration graph of the proposed method was linear in the range of 5–500 μg mL−1 (octopamine and tyramine) and 0.025–2.5 μg mL−1 (phenethylamine). The relative standard deviations were 2.4–3.2% (n = 6) and the limits of detection were in the range of 0.02–5 ng mL−1. The method was applied to analyze the rice wine samples and spiked recoveries in the range of 95.42–104.56% were obtained. The results showed that ultrasound-assisted dispersive liquid–liquid microextraction was a very simple, rapid, sensitive and efficient analytical method for the determination of trace amount of biogenic amines.  相似文献   

2.
A rapid and sensitive reversed-phase high performance liquid chromatography– fluorescence-mass spectrometer (RP-HPLC–FLD-MS) method based on pre-column derivatization using 2-(5-benzoacridine)ethyl-p-toluenesulfonate (BAETS) as labelling reagent has been developed for simultaneous determination of five triterpenic acids (asiatic acid (AA), maslinic acid (MA), corosolic acid (CA), oleanolic acid (OA), and betulinic acid (BA). The presented method was validated for linearity (correlation coefficient R2 > 0.9994), precision (RSD 2.1%–3.9%) and reproducibility (RSD 0.01%–2.1%). The limits of detection (LODs) and the limits of quantitation LOQs were within the range of 0.71–1.02 ng mL?1 and 2.28–3.24 ng mL?1, respectively. The proposed method was successfully applied to simultaneously determine five triterpenic acids of four Corydalis plants and showed satisfactory reproducibility and credibility. Moreover, several main parameters affecting extraction procedure and derivatization efficiency were investigated by response surface methodology (RSM), respectively. Triterpenic acid content in four Corydalis plants was measured according to the established method and the results indicated that triterpenic acid contents were various in different organs and herbs.  相似文献   

3.
A simple and reliable method has been developed for the rapid analysis of trace levels of malachite green from water samples using dispersive liquid–liquid microextraction and high-performance liquid chromatography-diode array detection. Factors relevant to the microextraction efficiency, such as the type and volume of extraction solvent, nature and volume of the disperser solvent, the effect of salt, sample solution temperature and the extraction time were investigated and optimised. Under the optimal conditions the linear dynamic range of malachite green was from 0.2 to 100.0?µg?L?1 with a correlation coefficient of 0.9962. The detection limit and limit of quantification were 0.1?µg?L?1 and 0.3?µg?L?1, respectively. The relative standard deviation (RSD) was less than 2.6% (n?=?5) and the recoveries of malachite green (5.0?µg?L?1) from water samples were in the range of 99.2?±?1.7%. Finally the proposed method was successfully applied for the analysis of malachite green from fish farming water samples.  相似文献   

4.
A method for the highly sensitive determination of 2-, 3- and 4-nitrophenols was developed using reverse-phase high-performance liquid chromatography (RP-HPLC) with a UV photodiode array detector. Using a reverse-phase column and 40% aqueous acetonitrile as an eluent (i.e. isocratic elution), the integrated peak area of detector output was linear up to 300 mg/L and the detection limit was 150 µg/L. The sensitivity of this detection method was improved by pretreating the sample solutions with a solvent extraction procedure that makes use of the high partition coefficient of ethyl acetate (EA)/water system. To find an optimum condition for the extraction procedure, this process was simulated by plotting the concentration of nitrophenol extracted in organic solvent against the volume multiplication factor at various partition coefficient of solute. This simulation demonstrated that EA is a superior extractant to other organic solvents. With the newly developed method, the detection limit was extended to 0.3 µg/L. This method offers fast, reliable and more sensitive determination of nitrophenol isomers than any other HPLC method.  相似文献   

5.
A new highly sensitive and rapid approach to the determination of 1,1-dimethylhydrazine in natural water is developed (determination range is 0.03–1 μg/L). It is based on the use of high-performance liquid chromatography–tandem mass spectrometry with precolumn derivatization by phenylglyoxal and does not require any preconcentration. Derivatization, chromatographic separation conditions, and tandem mass spectrometry detection parameters are chosen. Intra-day precision of the results of measurements of 1,1- dimethylhydrazine in natural water is 12–16%, and inter-day precision is 16–22%. The lowest limit of detection and the lowest limit of quantification are 0.010 μg/L and 0.030 μg/L, respectively.  相似文献   

6.
A method termed dispersive liquid–liquid microextraction (DLLME) coupled with high-performance liquid chromatography-variable wavelength detection (HPLC-VWD) was developed. DLLME-HPLC-VWD is a method for determination of bisphenol A (BPA) in water samples. In this microextraction method, several parameters such as extraction solvent volume, sample volume, disperser solvent, ionic strength, pH, and disperser volume were optimised with the aid of interactive orthogonal array and a mixed level experiment design. First, an orthogonal array design was used to screen the significant variables for the optimisation. Second, the significant factors were optimised by using a mixed level experiment. Under the optimised extraction conditions (extraction solvent: ionic liquid [C6MIM][PF6], 60 µL; dispersive solvent: methanol, 0.4 mL; and pH = 4.0), the performance of the established method was evaluated. The response linearity of the method was observed in a range of 0.002–1.0 mg L?1 (three orders of magnitude) with correlation coefficient (R 2) of 0.9999. The repeatability of this method was 4.2–5.3% for three different BPA levels and the enrichment factors were above 180. The extraction recovery was about 50% for the three different concentrations with 3.4–6.4% of RSD. Limit of detection of the method was 0.40 µg L?1 at a signal-to-noise ratio of 3. In addition, the relative recovery of sample of Songhua River, tap water and barrel-drain water at different spiked concentration levels was ranged 95.8–103.0%, 92.6–98.6% and 87.2–95.3%, respectively. Compared with other extraction technologies, there have been the following advantages of quick, easy operation, and time-saving for the present method.  相似文献   

7.
The present work demonstrates the successful application of automated biocompatible in-tube solid-phase microextraction coupled with liquid chromatography (in-tube SPME/LC) for determination of interferon alpha(2a) (IFN α(2a)) in plasma samples for therapeutic drug monitoring. A restricted access material (RAM, protein-coated silica) was employed for preparation of a lab-made biocompatible in-tube SPME capillary that enables the direct injection of biological fluids as well as the simultaneous exclusion of macromolecules by chemical diffusion barrier and drug pre-concentration. The in-tube SPME variables, such as sample volume, draw/eject volume, number of draw-eject cycles, and desorption mode were optimized, to improve the sensitivity of the proposed method. The IFN α(2a) analyses in plasma sample were carried out within 25min (sample preparation and LC analyses). The response of the proposed method was linear over a dynamic range, from 0.06 to 3.0MIUmL(-1), with correlation coefficient equal to 0.998. The interday precision of the method presented coefficient of variation lower than 8%. The proposed automated method has adequate analytical sensitivity and selectivity for determination of IFN α(2a) in plasma samples for therapeutic drug monitoring.  相似文献   

8.
A novel universal aerosol-based detector Nano Quantity Analyte Detector – NQAD™, connected with an ultra-performance liquid chromatography system is described. The detector was employed for detection of selected antibiotic compounds – macrolides (oleandomycin, erythromycin, troleandomycin, clarithromycin and roxithromycin) that are hard to detect using classical UV detectors due to the lack of chromophores. The determined lowest detection limits under isocratic conditions for these compounds ranged from 3.0 to 5.4 μg/mL. The suitability of the detector connected with ultra high-performance liquid chromatography in the gradient mode was tested on a more complex mixture containing 12 antibiotics. The detector exhibited full compatibility under both the elution modes when UHPLC separations were achieved in relatively short run times.  相似文献   

9.
In this study we on-line coupled hollow fiber liquid–liquid–liquid microextraction (HF-LLLME), assisted by an ultrasonic probe, with high-performance liquid chromatography (HPLC). In this approach, the target analytes – 2-chlorophenol (2-CP), 3-chlorophenol (3-CP), 2,6-dichlorophenol (2,6-DCP), and 3,4-dichlorophenol (3,4-DCP) – were extracted into a hollow fiber (HF) supported liquid membrane (SLM) and then back-extracted into the acceptor solution in the lumen of the HF. Next, the acceptor solution was withdrawn on-line into the HPLC sample loop connected to the HF and then injected directly into the HPLC system for analysis. We found that the chlorophenols (CPs) could diffuse quickly through two sequential extraction interfaces – the donor phase – SLM and the SLM – acceptor phase – under the assistance of an ultrasonic probe. Ultrasonication provided effective mixing of the extracted boundary layers with the bulk of the sample and it increased the driving forces for mass transfer, thereby enhancing the extraction kinetics and leading to rapid enrichment of the target analytes. We studied the effects of various parameters on the extraction efficiency, viz. the nature of the SLM and acceptor phase, the compositions of the donor and acceptor phases, the fiber length, the stirring rate, the ion strength, the sample temperature, the sonication conditions, and the perfusion flow rate. This on-line extraction method exhibited linearity (r2 ≥ 0.998), sensitivity (limits of detection: 0.03–0.05 μg L−1), and precision (RSD% ≤ 4.8), allowing the sensitive, simple, and rapid determination of CPs in aqueous solutions and water samples with a sampling time of just 2 min.  相似文献   

10.
A simple ultrasound-assisted dispersive liquid–liquid microextraction method combined with liquid chromatography was developed for the preconcentration and determination of six pyrethroids in river water samples. The procedure was based on a ternary solvent system to formatting tiny droplets of extractant in sample solution by dissolving appropriate amounts of water-immiscible extractant (tetrachloromethane) in watermiscible dispersive solvent (acetone). Various parameters that affected the extraction efficiency (such as type and volume of extraction and dispersive solvent, extraction time, ultrasonic time, and centrifuging time) were evaluated. Under the optimum condition, good linearity was obtained in a range of 0.00059–1.52 mg L−1 for all analytes with the correlation coefficient (r2) > 0.999. Intra-assay and inter-assay precision evaluated as the relative standard deviation (RSD) were less than 3.4 and 8.9%. The recoveries of six pyrethroids at three spiked levels were in the range of 86.2–109.3% with RSD of less than 8.7%. The enrichment factors for the six pyrethroids were ranged from 767 to 1033 folds.  相似文献   

11.
An improved analytical method enabling rapid and accurate determination and identification of bisphenol F diglycidyl ether (novolac glycidyl ether 2-ring), novolac glycidyl ether 3-ring, novolac glycidyl ether 4-ring, novolac glycidyl ether 5-ring, novolac glycidyl ether 6-ring, bisphenol A diglycidyl ether, bisphenol A (2,3-dihydroxypropyl) glycidyl ether, bisphenol A (3-chloro-2-hydroxypropyl) glycidyl ether, bisphenol A bis(3-chloro-2-hydroxypropyl) ether, and bisphenol A (3-chloro-2-hydroxypropyl) (2,3-dihydroxypropyl) ether in canned food and their contact packaging materials has been developed by using, for the first time, ultra-performance liquid chromatography coupled with tandem mass spectrometry. After comparison of electrospray ionization and atmospheric pressure chemical ionization in positive and negative-ion modes, tandem mass spectrometry with positive electrospray ionization was chosen to carry out selective multiple reaction monitoring analysis of novolac glycidyl ethers, bisphenol A diglycidyl ether, and its derivatives. The analysis time is only 5.5 min per run. Limits of detection varied from 0.01 to 0.20 ng g(-1) for the different target compounds on the basis of a signal-to-noise ratio (S/N) = 3; limits of quantitation were from 0.03 to 0.66 ng g(-1). The relative standard deviation for repeatability was <8.01%. Analytical recovery ranged from 87.60 to 108.93%. This method was successfully applied to twenty samples of canned food and their contact packaging materials for determination of migration of NOGE, BADGE, and their derivatives from can coatings into food.  相似文献   

12.
The objective of the present study was to develop and validate a rapid, highly sensitive, and reliable extraction method to determine acrylamide in water samples. The method was based on the derivatisation of the acrylamide in the presence of KBr, HBr and saturated Br2 solution into 2,3-dibromopropionamide and dispersive liquid–liquid microextraction (DLLME) followed by gas chromatography–electron capture detection (GC–ECD) of the analyte. Different parameters that affect the DLLME process such as types and volumes of disperser solvent, ionic strength of aqueous solution and extraction time were investigated and optimised. Under optimal conditions, excellent linearity was obtained between concentration of acrylamide and the response of ECD with correlation of determination (R2) of 0.9999. The precision of the method, which was determined by calculating the relative standard deviations (RSD) of the at least three replicate measurements, was 3.6%. The method presented in this study is sensitive enough for the determination of acrylamide in different water samples with the limit of detection (LOD) value of 1?ng?L?1. The mean percentage recoveries exceeded 91% for all of spiking levels in the real water samples. The results obtained from DLLME method are validated by EPA method 8032A.  相似文献   

13.
We developed an LC method for the sensitive and selective fluorometric determination of polythiols. This method employs pre-column intramolecular excimer-forming fluorescence derivatization with N-(1-pyrene)iodoacetamide followed by LC separation. Polythiols were converted to the corresponding dipyrene-labeled derivatives, and the derivatives afforded intramolecular excimer fluorescence (440–540 nm). After the optimization using dithiothreitol and dimercaprol as model polythiols, α-lipoic acid (LA) and α-lipoamide were determined with high sensitivity and selectivity. The detection limits for polythiols were 0.6–3.5 fmol on column. Furthermore, this method could be successfully applied to the determination of LA in commercial dietary supplements and in human urine.  相似文献   

14.
A liquid chromatography–electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) procedure was developed for the simultaneous determination of enantiomers of the prevalent designer drug 3,4-methylenedioxymethamphetamine (MDMA) and its phase I and phase II metabolites in urine with chiral derivatization. The analytes in urine were directly derivatized with chiral Marfey’s reagent, N α- (5-fluoro-2,4-dinitrophenyl)-d-leucinamide, without extraction. The diastereomers of the N α-(2,4-dinitrophenyl)-d-leucinamide derivatives generated were determined by LC-MS/MS. Satisfactory chromatographic separation was achieved for the enantiomers of MDMA and its metabolites 3,4-methylenedioxyamphetamine, 4-hydroxy-3-methoxymethamphetamine (HMMA), HMMA glucuronide, and HMMA sulfate on a semimicro octadecylsilane column using linear gradient elution. With use of multiple reaction monitoring mode, the limits of detection of these analytes ranged from 0.01 to 0.03?μg/mL. Linear calibration curves were obtained for all enantiomers from 0.1 to 20?μg/mL in urine. The method showed sufficient reproducibility and quantitative ability. This is the first report of a simple LC-MS/MS-based analytical procedure with direct chiral derivatization in aqueous media that allows simultaneous enantiomeric determination of drugs and their metabolites, including glucuronide and sulfate derivatives.  相似文献   

15.
A fast liquid chromatographic separation, coupled with sensitive and straightforward detection using a boron-doped diamond (BDD) electrode, was developed and validated for the determination of α-lipoic acid in dietary supplement samples. The analysis was carried out using a reversed phase C18 (150 mm × 4.6 mm, 5 μm) column with a mobile phase consisting of a 1:1 (v/v) ratio of 0.05 M phosphate solution (pH 2.5):acetonitrile, at a flow rate of 1.0 mL/min. The detection potential obtained from hydrodynamic voltammetry was 1.05 V vs. Ag/AgCl. Under optimized conditions, the chromatographic separation was performed in less than 5 min, a good linear relationship was obtained between the current and the α-lipoic concentration within the range of 0.01-60 μg/mL (correlation coefficient of 0.9971), and a detection limit of 3.0 ng/mL was determined. Furthermore, this method was successfully applied to determine α-lipoic acid concentrations in selected commercial dietary supplement samples. The recovery of α-lipoic acid in spiked samples at 0.5, 5.0 and 30 μg/mL ranged from 94.4% to 103.6% with a relative standard deviation (RSD) of between 1.2% and 3.7%. In real samples, this developed methodology produced results that were highly correlated with the standard HPLC-UV approach. Therefore, the present method can be used for fast, selective and sensitive quantification of α-lipoic acid in dietary supplements.  相似文献   

16.
Dispersive liquid-liquid microextraction as a rapid, simple and efficient method coupled with high performance liquid chromatography-UV-Vis detection was used for sample preparation and subsequent determination of carbazole, tri nitro carbazole (TrNC) and tetra nitro carbazole in water samples. The influence of several important variables on the extraction efficiency has been evaluated. The methods works best with chloroform as an extractant and acetonitrile as the dispersive solvent. Under optimum conditions, the calibration curve is linear in the range from 0.007 to 1.75?μg?mL?1 for TNC, 0.006 to 1.52?μg?mL?1 for TrNC, and 0.008–2.10?μg?mL?1 for carbazole. The limits of detection (LODs; at a signal-to-noise ratio of 3), range from 1.7 to 1.1?ng?mL?1, for TNC, TrNC and carbazole. Also, the relative standard deviations (RSD, n?=?6) for the extraction of TNC (at 174?ng?mL?1), TrNC (at 151?ng?mL?1) and carbazole (at 84?ng?mL?1) vary between 4.1 and 5.2%. The enrichment factors range from 179 to 186. The method was successfully applied to the determination of TNC, TrNC and carbazole in environmental samples.
Figure
Dispersive liquid-liquid microextraction is presented for the determination of carbazole based explosives (tri nitro carbazole (TrTNC) and tetra nitro carbazole (TNC)) using high performance liquid chromatography and UV–vis detection.  相似文献   

17.
Dichlorodiphenyltrichloroethane,1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane (DDT) and its main metabolites have been paid much more attention, and present paper describes a new process for the rapid determination of such pollutants in environmental water samples based on dispersive liquid–liquid microextraction (DLLME) and high performance liquid chromatography with ultraviolet detector, which has merits such as high enrichment factor and sensitivity, low cost and easy to operate. Significant parameters such as extraction solvent and dispersive solvent type and volume, pH, extraction time and centrifuging time, which would have important impact on the enrichment of target pollutants, have been investigated in detail. The results exhibited that excellent performance could be achieved with carbon tetrachloride and acetonitrile as the extraction solvent and dispersive solvent, respectively. Under the optimal conditions, excellent linear relationship was gained in the range of 1.0–50 μg L−1, and detection limits were in the range of 0.32–0.51 μg L−1. The precisions of the proposed method were in the range of 2.80–7.50% (RSD). The proposed method was validated with real water samples, and the results indicated the spiked recoveries were in the range of 85.58–119.6% and the established method was very good and competitive in the determination of DDT and its metabolites.  相似文献   

18.
19.
A new up-and-down shaker-assisted dispersive liquid–liquid microextraction (UDSA-DLLME) for extraction and derivatization of five chlorophenols (4-chlorophenol, 4-chloro-2-methylphenol, 2,4-dichlorophenol, 2,4,6-trichloro-phenol, and pentachlorophenol) has been developed. The method requires minimal solvent usage. The relatively polar, water-soluble, and low-toxicity solvent 1-heptanol (12 μL) was selected as the extraction solvent and acetic anhydride (50 μL) as the derivatization reagent. With the use of an up-and-down shaker, the emulsification of aqueous samples was formed homogeneously and quickly. The derivatization and extraction of chlorophenols were completed simultaneously in 1 min. The common requirement of disperser solvent in DLLME could be avoided. After optimization, the linear range covered over two orders of magnitude, and the coefficient of determination (r 2) was greater than 0.9981. The detection limit was from 0.05 to 0.2 μg L?1, and the relative standard deviation was from 4.6 to 10.8 %. Real samples of river water and lake water had relative recoveries from 90.3 to 117.3 %. Other emulsification methods such as vortex-assisted, ultrasound-assisted, and manual shaking-enhanced ultrasound-assisted methods were also compared with the proposed UDSA-DLLME. The results revealed that UDSA-DLLME performed with higher extraction efficiency and precision compared with the other methods.  相似文献   

20.
A novel method is reported, whereby screen-printed electrodes (SPELs) are combined with dispersive liquid–liquid microextraction. In-situ ionic liquid (IL) formation was used as an extractant phase in the microextraction technique and proved to be a simple, fast and inexpensive analytical method. This approach uses miniaturized systems both in sample preparation and in the detection stage, helping to develop environmentally friendly analytical methods and portable devices to enable rapid and onsite measurement. The microextraction method is based on a simple metathesis reaction, in which a water-immiscible IL (1-hexyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide, [Hmim][NTf2]) is formed from a water-miscible IL (1-hexyl-3-methylimidazolium chloride, [Hmim][Cl]) and an ion-exchange reagent (lithium bis[(trifluoromethyl)sulfonyl]imide, LiNTf2) in sample solutions. The explosive 2,4,6-trinitrotoluene (TNT) was used as a model analyte to develop the method. The electrochemical behavior of TNT in [Hmim][NTf2] has been studied in SPELs. The extraction method was first optimized by use of a two-step multivariate optimization strategy, using Plackett–Burman and central composite designs. The method was then evaluated under optimum conditions and a good level of linearity was obtained, with a correlation coefficient of 0.9990. Limits of detection and quantification were 7 μg L?1 and 9 μg L?1, respectively. The repeatability of the proposed method was evaluated at two different spiking levels (20 and 50 μg L?1), and coefficients of variation of 7 % and 5 % (n?=?5) were obtained. Tap water and industrial wastewater were selected as real-world water samples to assess the applicability of the method.
Figure
?  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号