首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method is described for the determination of C10-C20 hydrocarbons in natural gas. Enrichment by solid phase extraction on ODS followed by liquid desorption was found to give better results than adsorption on Tenax or charcoal followed by liquid or thermal desorption.  相似文献   

2.
The retention factor and height equivalent of a theoretical plate for gaseous hydrocarbons C1—C4 were studied on capillary columns with the layer of the new polymeric adsorbent polytrimethylsilylpropyne (PTMSP) as functions of the nature and pressure of the carrier gas. The retention factor k increases in the series helium < nitrogen < carbon dioxide. The k values depend linearly on the average pressure of the carrier gas in a capillary column with the adsorption PTMSP layer.  相似文献   

3.
Summary Results of studies on stationary phases containing copper(II), nickel(II) and cobalt(II) chloride chemically bonded via cyano—or thiol groups are presented. The retention parameters—i.e. retention factor (k), retention index (I) and molecular retention index (ΔMe) and specific retention volume (Vg)-enabled the characteristics of specific interaction between aromatic and cyclic hydrocarbons and metal complexes chemically bonded to stationary phases to be determined. Presented at Balaton Symposium on High Performance Separation Methods, Siófok, Hungary, September 1–3, 1999  相似文献   

4.
Summary A detection system for gas chromatography based on gas-phase, molecular absorption measurements is presented, in which the chromatographic column is directly joined to the spectrophotometer flow cell, without heated transfer lines. To maintain polyciclic aromatic hydrocarbons (PAHs) in the gas phase during detection an aluminium heater was constructed. A mixture of 13 PAHs was then separated and analyzed. Parameters affecting separation (temperature program and carrier gas flow) were studied and a program designed to modify the measurement wavelength during the chromatography. The analytical characteristics of each compound were calculated, obtaining detection limits 0.2–1.5 μg mL. Given that some compounds overlaped, it was necessary to resolve their peaks mathematicaly. Finally, the method was applied to a certified synthetic mixture, with good results.  相似文献   

5.
An analytical procedure using accelerated solvent extraction and gas chromatography with an electron capture detector has been optimized to simultaneously determine the residue of two insecticides (diazinon and EPN) and one fungicide (isoprothiolane) in polished rice and was confirmed by GC-mass spectrometry. Several parameters, including temperature, pressure, solvent ratio, cell size and cell cycle, were thoroughly investigated to find the optimal extraction conditions. The average recoveries of the three pesticides were between 82.7 and 126.4% at spiking levels of 0.1 and 0.5 ppm. The relative standard deviations were less than 7% for all of the recovery tests. The optimum accelerated solvent extraction operating conditions were 100 degrees C, 1500 atm, acetone-n-hexane (20:80 v/v) as the extraction solvent, two cycles, and a cell size of 33 ml. The total extraction time was approximately 20 min. The optimized procedure has also been applied to the determination of diazinon, isoprothiolane and EPN in real rice samples. In conclusion, accelerated solvent extraction was used for the first time for the analysis of diazinon, isoprothiolane and EPN in polished rice and offers the possibility of a fast and simple process for obtaining a quantitative extraction of the studied pesticides.  相似文献   

6.
Analyses of hydrocarbon fractions from different areas of the marine environment are described to illustrate the possibilities and limitations of high resolution gas chromatography (HRGC) in the analysis of environmental samples. Examples are given of dissolved, particulate, and sedimentary hydrocarbons and organochlorine compounds; the importance of an adequate sampling of the marine environment is stressed. HR chromatographic profiles obtained in two columns of low and high polarity (SE-52 and PEG 20M) permit the sources and transport pathways of both natural and anthropogenic hydrocarbons to be traced. Analysis of tissues of marine mammals, which metabolize or excrete many of the biogenic and petrogenic hydrocarbons present in other areas of the marine environment, may provide an opportunity to obtain relatively clean profiles of many anthropogenic compounds of interest. The plotting of mass chromatograms from data compiled by COM-GC-MS remains the most appropriate method for the conclusive indentification of these compounds.  相似文献   

7.
Curvers  J.  Noij  T.  Cramers  C.  Rijks  J. 《Chromatographia》1984,19(1):225-230
Summary A slightly modified steam distillation-extraction device is described for the continuous extraction and preconcentration of organic traces in aqueous samples, prior to capillary G.C.-analysis. The quantitative performance, both theoretically and practically, is studied using phenols as the test substances. The final recovery is determined by the flow-ratio of the water and the extracting solvent and by the extraction coefficient. The process is found to be highly reproducible even at low concentration levels (ppb’s). Using 30 ml. samples with a concentration of 30 ppb (1:10^9), 100 % recoveries are obtained for the phenolic substances studied, with a relative standard deviation of about 3 %, both for methylene chloride and ethylacetate as the extracting solvents. Using methylene chloride as the extracting solvent, for phenol a maximum recovery of 80 % was obtained. Presented at the 15th International Symposium on Chromatography, Nürnberg, October 1984  相似文献   

8.
A method for the determination of 16 polycyclic aromatic hydrocarbons in water has been developed. First, we made a solid‐phase extraction column. After this, the parameters affecting the efficacy of the experimental method were optimized, including appropriate selection of a solid‐phase extraction column and cleanup conditions on columns. The separation was achieved by gas chromatography and detection with triple quadrupole tandem mass spectrometry. The method showed satisfactory linearity (R> 0.999) over the range assayed (0.01–1 μg/mL), and limits of quantification ranging from 0.0011 to 0.0199 μg/L. The recoveries ranged from 83 to 113%. The relative standard deviation is in the range 0.86–3.1%. The results indicated that this method had high selectivity and precision that was suitable for the simultaneous determination of 16 polycyclic aromatic hydrocarbons in water.  相似文献   

9.
10.
Summary The retention index of a planar polynuclear aromatic hydrocarbon on the GC phases OV-101, SE-52, and OV-17 is strictly related only to the boiling point, and less closely to the relative molecular mass. The very approximates relation with connectivity index ins only a consequence of the latter. On a nematic lqiuid crystal phase, a variation of activity coefficient, expressed in terms of a shape factor, also influences the retention of PAH.  相似文献   

11.
A fast and reliable analytical technique for the determination of total sulfur levels in complex hydrocarbon matrices is introduced. The method employed flow injection technique using a gas chromatograph as a sample introduction device and a gas phase dual‐plasma sulfur chemiluminescence detector for sulfur quantification. Using the technique described, total sulfur measurement in challenging hydrocarbon matrices can be achieved in less than 10 s with sample‐to‐sample time <2 min. The high degree of selectivity and sensitivity toward sulfur compounds of the detector offers the ability to measure low sulfur levels with a detection limit in the range of 20 ppb w/w S. The equimolar response characteristic of the detector allows the quantitation of unknown sulfur compounds and simplifies the calibration process. Response is linear over a concentration range of five orders of magnitude, with a high degree of repeatability. The detector's lack of response to hydrocarbons enables direct analysis without the need for time‐consuming sample preparation and chromatographic separation processes. This flow injection‐based sulfur chemiluminescence detection technique is ideal for fast analysis or trace sulfur analysis.  相似文献   

12.
Shun-Li Fan  Lixia Zhao  Jin-Ming Lin   《Talanta》2007,72(5):1618-1624
In the present work, a simple method of sample preparation for the determination of polycyclic aromatic hydrocarbons (PAHs) in water rich in colloidal particulate was developed. The technique was mainly based on the effect of the flocculation of aluminum sulfate and the adsorption of the flocculation aid florisil. The method contained three steps: flocculation, ultrasonic extraction, and solid-phase extraction cleanup. Major parameters of the procedure were optimized with high performance liquid chromatography (HPLC) separation and ultraviolet-fluorescence detection. When 250 mL model sample containing 16 EPA PAHs was processed, the developed method provided detection limits in the range of 0.02–5 ng/L. Both spiked and non-spiked polluted river water samples rich in suspended particles and organic matters were analyzed. Recoveries and relative standard deviations for the 16 PAHs were in ranges of 86–94% and 3–13% (n = 5), respectively.  相似文献   

13.
Lubov Oliferova  Yury Zolotov 《Talanta》2007,72(4):1386-1391
Naphthalene, biphenyl, acenaphtene, anthracene and pyrene were extracted from water samples using inner walls of polytetrafluoroethylene capillary. Optimum conditions for sorption, desorption and heart-cutting of the analyte zone were found. Combined on-line solid-phase extraction and HPLC method for determination of these compounds was proposed. Limits of detection were: (μg L−1): 0.4 (naphthalene), 0.3 (biphenyl), 0.6 (acenaphtene), 0.2 (anthracene) and 0.1 (pyrene).  相似文献   

14.
An automated system employing a purge and trap technique with capillary gas chromatography and electron-capture detection (ECD) has been developed for the analysis of trace levels of volatile halogenated hydrocarbons and applied to the determination of the compounds in environmental samples such as rainwater and ambient air. The operation of the method, its application to environmental samples, and the results obtained are described. Use of the system ensured good chromatographic resolution and high accuracy, even with trace levels of the compounds.  相似文献   

15.
In order to investigate the relationship between terpenoid content and black bear foraging preference, an analytical method was required to quantify mono- and sesquiterpenoids present in Douglas-fir sapwood. Sapwood samples were scraped from trees, immediately frozen in liquid nitrogen, and then homogenized. A simple extraction requiring no clean-up step was performed with ethyl acetate. Extracts were analyzed by gas chromatography with mass selective detection versus external standards. The recoveries of 22 terpenoids from fortified controls were approximately 90% with good precision (relative standard deviations of approximately 10%).  相似文献   

16.
We propose a method for the simultaneous determination of 15 kinds of polycyclic aromatic hydrocarbons in marine samples (muscle) employing gas chromatography with mass spectrometry after saponification with ultrasound‐assisted extraction and solid‐phase extraction. The experimental conditions were optimized by the response surface method. In addition, the effects of different lyes and extractants on polycyclic aromatic hydrocarbons extraction were discussed, and saturated sodium carbonate was first used as the primary saponification reaction and extracted with 10 mL of ethyl acetate and secondly 1 mol/L of sodium hydroxide and 10 mL of n‐hexane were used to achieve better results. The average recovery was 67–112%. Satisfactory data showed that the method has good reproducibility with a relative standard deviation of <13%. The detection limits of polycyclic aromatic hydrocarbons were 0.02–0.13 ng/g. Compared with other methods, this method has the advantages of simple pretreatment, low solvent consumption, maximum polycyclic aromatic hydrocarbons extraction, the fast separation speed, and the high extraction efficiency. It is concluded that this method meets the batch processing requirements of the sample and can also be used to determine polycyclic aromatic hydrocarbons in other high‐fat (fish, shrimp, crab, shellfish) biological samples.  相似文献   

17.
18.
Guo K  Zhou J  Liu Z 《色谱》2012,30(2):128-134
通过对升温速度、二维补偿温度、调制周期等关键实验参数的优化,建立了全二维气相色谱-飞行时间质谱(GC×GC-TOF MS)分析重馏分油中芳烃组分的方法,得到了重馏分油芳烃组分按环数分布的二维点阵图。根据谱库检索、标准化合物对照及文献报道,对重馏分油芳烃组分中菲、甲基菲及芘、苯并蒽等常见多环芳烃(PAH)进行了准确定性,并将该方法应用到重馏分油加氢处理工艺研究中,对菲、芘的加氢处理产物进行了定性分析。该研究为重馏分油芳烃组分的准确定性提供了新的技术手段,为加深对油品加氢规律的认识提供了技术支持。全二维气相色谱与普通一维色谱对比,在重馏分油的芳烃组分分析上体现了极大优势。  相似文献   

19.
20.
固相萃取-气相色谱法测定北京市水样中的邻苯二甲酸酯   总被引:16,自引:0,他引:16  
研究了使用毛细管柱(OV-1701)分离、FID作为检测器的气相色谱法测定水中5种邻苯二甲酸酯(PAEs)[邻苯二甲酸二乙酯(DEP),邻苯二甲酸二丁酯(DBP),邻苯二甲酸丁基苄基酯(BBP),邻苯二甲酸二(2-乙基己基)酯(DEHP),邻苯二甲酸二环己酯(DCHP)]的色谱条件。5种PAEs检出限在0.1~0.3μg/L之间,所测PAEs的质量浓度在0.5~100μg/L范围内,RSD在2.2%~3.3%之间,各物质校正曲线(质量浓度与峰面积)的相关系数在0.9970~0.9993之间。利用固相萃取技术萃取水中PAEs,回收率在82.5%~110.5%之间,RSD在1.1%~4.0%之间。北京市吴家村污水处理厂4个采样点中邻苯二甲酸酯浓度在(0.7~193.3)μg/L之间。北京市南护城河的3个采样点中邻苯二甲酸酯浓度在(0.1~241.8)μg/L之间。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号