首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A microcomputer-controlled automatic potentiometric titrator withP controlled intelligent auto-sampler has been built for serial analysis. Controlling and evaluating programs have also been written. In order to use the most powerful evaluating method, a comparison was made between the methods. The data of the titration curves were obtained by the implicit relation characterizing the curve. The different evaluating methods were tested by using these data. The effects of random errors stemming from measurements were also investigated. The methods used were: two point differentiating formula, differentiation of interpolating and smoothing spline functions, the Gran method, and implicit regression with the Gauss-Newton-Marquardt method. Regression is outstanding among the methods, but it needs much more computing time compared with others. The second-best method is the differentiation with smoothing spline function with end point determination based on finding the sign reversal of the second derivative. This method is much faster than regression.  相似文献   

2.
The feasibility of a metal palladium electrode as the pH sensor in air-saturated aqueous solutions was evaluated. The measurement was based on an “on-site” precleaning step and a potential decay process. The experimental results showed a linear pH response with a sensitivity of around 60 mV/pH and good reproducibiliry. The temperature effect on the measurement was also evaluated.  相似文献   

3.
A chemically modified electrode (CME) for use as a potentiometric pH sensor was constructed by electropolymerizing a poly(4,4′-diaminobiphenyl) coating on a platinum electrode. The resulting CME gave a linear response to pH in the range 1–12 with a slope of ?56 mV pH?1. The CME functioned well in titration experiments and in pH measurements. No significant interference of a coexisting redox couple with the pH measurements was observed. The mechanism of the pH response of the CME is considered.  相似文献   

4.
分别采用紫外分光光度法和电位滴定法测定了脱落酸、3-吲哚乙酸、赤霉素、水杨酸等几种植物激素的电离常数,对比分析了两种测试方法的原理、测试步骤和数据处理方法.结果表明,采用两种方法测定的四种样品的电离常数与文献报道值一致,且测量结果的重现性较好;这表明紫外分光光度法和电位滴定法可方便地用于测定有机化合物的电离常数.  相似文献   

5.
A fast novel complexometric titration procedure is proposed, in which equivalence concentrations were determined using a potentiometric electronic tongue. The titration consists in a reduced number of fixed additions of titrant and the recording of the potentials of an array of ion-selective electrodes with cross-selectivity response. The generated data (number of sensors × number of additions) were used as input data to an artificial neural network response model previously trained with standards. The application of this procedure is demonstrated with automated EDTA titrations of Ca2+, Mg2+ and Sr2+ mixtures, up to 3.3 mM total ion concentration. In the studied case, good results predicting the three concentrations were obtained using five 1 mL fixed volume additions plus the readings of eight sensors. The unique additional step required was the pH buffering of the sample to pH 9.5. Good comparisons were observed between obtained and expected concentrations for the three cations with the external validation samples (n = 17, with RMSE values of 0.18, 0.28 and 0.32 mM for Ca2+, Mg2+ and Sr2+, respectively). The proposed procedure was applied to mineral waters and compared with reference methods.  相似文献   

6.
Masadome T  Imato T 《Talanta》2003,60(4):663-668
A plasticized poly (vinyl chloride) (PVC) membrane electrode sensitive to stearyltrimethylammonium (STA) ion is applied to the determination of cationic polyelectrolytes such as poly (diallyldimethylammonium chloride) (Cat-floc) by potentiometric titration, using a potassium poly (vinyl sulfate) (PVSK) solution as a titrant. The end-point of the titration is detected as the potential change of the plasticized PVC membrane electrode caused by decrease in the concentration of STA ion added to the sample solution as a marker ion due to the ion association reaction between the STA ion and PVSK. The effects of the concentration of STA ion, coexisting electrolytes in the sample solution and pH of the sample on the degree of the potential change at the end-point were examined. A linear relationship between the concentration of cationic polyelectrolyte and the end-point volume of the titrant exists in the concentration range from 2×10−5 to 4×10−4 N for Cat-floc, glycol chitosan, and methylglycol chitosan.  相似文献   

7.
A chemically modified electrode (CME) was prepared and studied as a potentiometric sensor for the end-point detection in the automatic titration of vanadium(V) with EDTA. The CME was constructed with a paste prepared by mixing spectral-grade graphite powder, Nujol oil and N-2-naphthoyl-N-p-tolylhydroxamic acid (NTHA). Buffer systems, pH effects and the concentration range were studied. Interference ions were separated by applying a liquid-liquid extraction procedure.The CME did not require any special conditioning before using. The electrode was constructed with very inexpensive materials and was easily made. It could be continuously used, at least two months without removing the paste.Automatic potentiometric titration curves were obtained for V(V) within 5 × 10−5 to 2 × 10−3 M with acceptable accuracy and precision. The developed method was applied to V(V) determination in alloys for hip prothesis.  相似文献   

8.
pH电位滴定法测定溶液中钙、镁离子与聚天冬氨酸的生成稳定常数;pH电位滴定;聚天冬氨酸;配位化学;钙离子;镁离子  相似文献   

9.
A novel ion selective carbon paste electrode for Cd2+ ions based on 2,2′-thio-bis[4-methyl(2-amino phenoxy) phenyl ether] (TBMAPPE) as an ionophore was prepared. The carbon paste was made based on a new nano-composite including multi-walled carbon nanotubes (MWCNTs), nanosilica and room-temperature ionic liquid, 1-Butyl-3-methylimidazolium hexafluorophosphate (BMIM-PF6). The constructed nano-composite electrode showed better sensitivity, selectivity, response time, response stability and lifetime in comparison with typical Cd2+ carbon paste sensor for the successful determination of Cd2+ ions in water and in waste water samples. The best performance for nano-composite sensor was obtained with an electrode composition of 18% TBMAPPE, 20% BMIM-PF6, 48% graphite powder, 10% MWCNT and 4% nanosilica. The new electrode exhibited a Nernstian response (29.95?±?0.10?mV?decade?1) toward Cd2+ ions in the range of 3.0?×?10?8 to 1.0?×?10?1?mol?L?1 with a detection limit of 7.5?×?10?9?mol?L?1. The potentiometric response of prepared sensor was independent of the pH of test solution in the pH range 3.0 to 5.5. It had a quick response with a response time of about 6?s. The proposed electrode showed fairly good selectivity over some alkali, alkaline earth, transition and heavy metal ions.  相似文献   

10.
A new carbon paste electrode modified with tetramethyl thiuram disulfide is prepared to use as copper potentiometric sensor in batch and flow analysis. The influence of pH and carbon paste composition on the potentiometric response is studied. The principal parameters of the flow system are optimized and the detection limits and the selectivity coefficients of the potentiometric sensor are calculated for static and flow mode. In both cases, the sensor shows high selectivity to copper ions but in flow analysis this selectivity is higher. The obtained detection limits are 4.6 × 10−8 M for batch measurements and 2.0 × 10−7 M for on-line analysis. The potentiometric sensor is applied to copper(II) determination in real samples in static and flow measurements. In both analysis modes, successful results are obtained.  相似文献   

11.
In this study, a novel potentiometric titration of hydroperoxide in degraded polypropylene (PP) is proposed. This titration is quite sensitive compared with the conventional ones such as UV and manual titrations, and its detection limit was about 2 meq/kg. The sensitivity was equal to that of molecular weight measurement by GPC for the degraded PP and, in addition, the volatilization behavior of the hydroperoxide could be detected. This titration was found to be very effective for the determination of PP degradation.  相似文献   

12.
Solid-contact electrode for pH measurements in acidic media is described. The sensor membrane is made of polyvinyl chloride plasticized with bis(2-ethylhexyl)phthalate and contains neutral pH-selective ionophore hexabutyltriamidophosphate and potassium tetrakis-p-Cl-phenylborate cation exchanger. The transducer layer of the solid-contact electrode contains the same membrane composition and also carbon black and electron–ion-exchanger resin EI-21(a cation exchange resin containing fine dispersion of metal copper) for stabilization of the electrode potential. The electrode is suitable for measurements of pH in the range 0–6 and works also in hydrofluoric acid (HF) solutions up to 0.1 M HF. Chronopotentiometric measurements show diffusion-limited polarization at the interface between sensor membrane and transducer layer. The slope of the linearized polarization curve correlates with the long-term stability of the electrode potentials providing a tool for prediction of the long-term stability of solid-contact potentiometric sensors.  相似文献   

13.
本文报道用铂制作的电量型pH传感器,其原理是铂电极表面上氧化物在形成单分子氧化物覆盖前的覆盖度与溶液pH值之间存在一定的关系,pH值的改变会导致铂表面氧化物覆盖度的改变,并以一定的电量变化为表现形式。在碱性溶液中,该传感器对pH值变化的响应呈线性变化规律,且响应时间小于100ms,精度小于0.2个pH值。该pH传感器可检测反应过程中pH值的暂态变化,适用于研究电极反应或有中间体生成的反应的机理。该传感器的有效性在用扫描电化学显微镜(SECM)探针-基底伏安模式研究氢氧化镍的充放电的过程中得到验证。  相似文献   

14.
There are some electrocatalytic reactions in which the key parameter explaining their behavior is a local change in pH. Therefore, it is of utter importance to develop an electrode that could quantify this parameter in situ, but also be customizable to be used in different systems. The purpose of this work is to build a versatile rotating ring/disc electrode (RRDE) with IrOx deposited on a glass tube as a ring and any kind of material as disc. As the IrOx is sensitive to pH variation, the reactions promoted on the disc can trigger proportional pH shifts on the ring. In such assembly, the IrOx ring presents a fast response time even during the pH transients due to the small thickness of the ring (approximately 10 μm), which enables the detection of interfacial pH changes. The ring electrode was tested toward the interfacial pH shift observed during the electrolytic reduction of water on the disc and also characterized by acid–base titration to determine the response time. As the main conclusions, fast response and durable RRDE were obtained, and this assembly could be used to revisit many electrocatalytic reactions in order to test the importance of local pH on the process.  相似文献   

15.
This work demonstrates the extended application of microscale chemistry which has been used in the educational discipline to the real analytical purposes. Using Volhard's titration for the determination of sodium chloride as a paradigm, the reaction was downscaled to less than 2 mL conducted in commercially available microcentrifuge tubes and using micropipettes for the measurement and transfer of reagents. The equivalence point was determined spectrophotometrically on the microplates which quickened the multi-sample measurements. After the validation and evaluation with bulk and dosage forms, the downsized method showed good accuracy comparable to the British Pharmacopeial macroscale method and gave satisfactory precision (intra-day, inter-day, inter-analyst and inter-equipment) with the relative standard deviation of less than 0.5%. Interestingly, the amount of nitric acid, silver nitrate, ferric alum and ammonium thiocyanate consumed in the miniaturized titration was reduced by the factors of 25, 50, 50 and 215 times, respectively. The use of environmentally dangerous dibutyl phthalate was absolutely eliminated in the proposed method. Furthermore, the release of solid waste silver chloride was drastically reduced by about 25 folds. Therefore, microscale chemistry is an attractive, facile and powerful green strategy for the development of eco-friendly, safe, and cost-effective analytical methods suitable for a sustainable environment.  相似文献   

16.
The potentiometric characteristics of a new Cu2+‐selective electrode based on 2‐(benzyliminomethyl)‐6‐methoxy‐4‐(4‐methoxyphenyl‐azo) phenol as an efficient ionophore has been evaluated. The effects of influential parameters on the potentiometric responses such as the amount of plasticizer, the amount of ionophore, pH of the sample solution, and the effect of coexisting ions on the electrode signal were subsequently investigated . The selectivity of the electrode was assessed by calculating the selectivity coefficients using the matched potential method. The optimum ratio of the amount of materials required for the preparation of the electrode was found to be 1.7: 32.1: 64.2: 2.0 corresponding to carboxylated PVC, dimethyl sebacate as solvent mediators, potassium tetrakis (p‐chlorophenyl) borate as the anion localizing agent, and ionophore, respectively. The electrode had a fast response (7s) as well as a satisfactory Nernstian slope (29.26±0.91 mV/decade) to Cu2+ over a wide concentration range of 2.0×10?6‐ 5.0×10?2 M with a low detection limit of 5.9×10?7 M. The developed sensor was successfully used for the potentiometric titration of Cu2+ ion with EDTA and subsequently, efficient determination of this metal ion in a mineral water sample was performed.  相似文献   

17.
Degradation process of polymer electrolyte was investigated by pH titration and solution analysis. Perfluorosulfonic acid, which is generally used for fuel cells and sensors, was irradiated with gamma-ray. Irradiated samples were immersed in distilled water, and the suspensions were titrated with NaCl solution while pH was monitored. Initial pH without any sodium ion decreased as increase in absorbed dose, indicating acid release from polymer electrolyte. To identify the chemical structure of dissolved species, solution analysis was performed by ion chromatography, total organic carbon (TOC) analyzer, and inductively-coupled plasma atomic emission spectrometry (ICP-AES). It was shown that proton, sulfide ion, fluorine ion and organic carbon were detected in the solution, and the ratio among these ions and atoms changed depending on the irradiation conditions. It shows that the solution analysis can identify the scission site by irradiation sensitively, and gives useful information for investigation of polymer degradation process.  相似文献   

18.
A new potentiometric sensor for the rapid determination of Hg2+ based on modified carbon paste electrode consisting of room temperature ionic liquid, 1-Butyl-3-methylimidazolium hexafluorophosphate (BMIM-PF6), multi-walled carbon nanotubes (MWCNTs), alumina nanoparticles and a synthetic macrocyclic diamide ‘7,10,13-triaza-1-thia-4,16-dioxa-6,14-dioxo-2,3;17,18-dinaphtho-cyclooctadecane’ as an efficient ionophore was constructed. Prepared composite is an ideal paste because it has low drift of potential, high selectivity and fast response time (10 s), which leads to a more stable potential signal. The morphology and properties of electrodes surface were characterised by scanning electron microscopy (SEM) and electrochemical impedance spectroscopy. A linear dynamic range of 2.01–2.01 × 107 µg L?1 with detection limit of 1.40 µg L?1 Hg2+ was obtained at pH range of 2.5 to 4.5. The prepared modified electrode shows several advantages such as simple preparation method, high stability of the composite paste, high sensitivity, long-term life time (at least 13 weeks) and remarkable potentiometric reproducibility. The modified electrode was successfully applied for the accurate determination of trace amounts of Hg 2+ in environmental samples.  相似文献   

19.
《Analytical letters》2012,45(5):711-724
Abstract

A flow injection potentiometric procedure is proposed for the determination of acidity of several samples using an antimony/ antimony oxide electrode. The ΔE/pH curve in phosphate buffer solutions in the pH range from 1.58 to 12.00 showed a linear sub-Nernstian behavior with an operational slope S =-42.1mV/pHc and a conditional standard potential of 264.8mV. This flow potentiometric electrode responds linearly to low acidity variations of dilute acetic acid solutions from 3.16 to 100mM with a slope of 30.1mV/dec and analytical frequency of 23 results/h. Good reproducibility and an average standard deviation of ±0.5% was obtained. The application of this sensor for the determination of coke acidity and acetic acid in vinegar is reported.  相似文献   

20.
采用一种具有平头结构的pH电极作为流动注射分析(FIA)的检测器,构建了流动注射自动化酸度滴定系统.优化了样品进样量、流速、载液浓度和反应管长度等参数.用NaOH溶液作为载液,在4.639×10-4~0.212 mol·L-1范围内醋酸浓度的对数与FIA峰的峰面积成正比,该方法的相对标准偏差(RSD)小于0.5%.采用...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号