首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
建立了原多甲藻酸毒素(azaspiracids,AZAs)及其代谢产物的液相色谱-串联质谱检测方法,考察了目标代谢产物检测方法和非目标多离子检测方法,将二级质谱图与标准品谱库进行比对,从而获得高精准定性。通过对产毒藻、蓄积代谢实验样品和实际阳性样品综合分析,共检出11种AZAs,其中包括AZA-2,3,6,11,12,16,17,28和36,以及AZAs的谷胱甘肽结合型代谢产物。结果发现,目标代谢产物检测法可无偏差地筛出常规代谢物,而且对低浓度代谢产物表现出更佳的响应。本方法重现性好,数据分析简单,对操作人员的专业要求不高,更适合AZAs的监控要求。  相似文献   

2.
付慧  陆一夫  胡小键  张续  杨艳伟  朱英 《色谱》2020,38(6):715-721
建立了灵敏、准确的液液萃取-高分辨气相色谱-高分辨双聚焦磁质谱(LLC-HRGC-HRMS)同时测定人体尿样中8种多环芳烃(PAHs)代谢物的方法。将2 mL尿液与氘或13C标记的同位素内标物进行混合,在抗坏血酸的存在下酶解偶联目标物,再将游离化合物用甲苯-戊烷(1:4,v/v)萃取后浓缩至近干,再用甲苯复溶,衍生后经HRGC-HRMS分离和测定。1-羟基萘在0.14~41.6 μg/L、1-羟基菲在0.05~8.33 μg/L、2-羟基菲在0.04~8.33 μg/L、其他5种代谢产物在0.02~8.33 μg/L范围内线性关系良好,相关系数>0.99,方法的检出限为0.006~0.042 μg/L,平均回收率为81.4%~127.0%,日内和日间精密度分别为2.7%~6.9%和5.1%~10.9%(n=6)。应用该方法测定330份人群尿液样本,3-羟基䓛和6-羟基䓛未检出,其他6种PAHs代谢物检出率为100%。该方法灵敏、准确、稳定,适用于人尿中8种PAHs代谢物的定量分析。  相似文献   

3.
建立了固相萃取-液相色谱-串联质谱同时测定尿中2-羟基萘、1-羟基萘、2-羟基芴、3-羟基菲、1-羟基芘等9种多环芳烃代谢物的液相色谱-串联质谱测定方法。尿样中结合态的多环芳烃代谢物在β-葡萄糖苷酸酶-芳基硫酸酯酶缓冲液(pH 5.0)作用下,于37℃水浴中避光水解4 h后,以C18固相萃取小柱富集、净化,以甲醇洗脱,采用Waters Symmetry C18色谱柱,流动相为乙腈-0.2%氨水(72∶27,V/V)等度淋洗分离后进入质谱测定。在喷雾电压4 kV,毛细管温度300℃下,以3-羟基菲13C为内标,采用SRM模式负离子扫描方式测定,内标法定量。9种多环芳烃代谢物在尿中的线性范围为0.90~100μg/L;相关系数为0.9970~0.9990;回收率为79.0%~119.8%;相对标准偏差为4.3%~12.4%;检出限为0.04~0.90μg/L;结果表明,本方法可用于尿中9种多环芳烃代谢物的测定。  相似文献   

4.
In this paper a solid-phase microextraction–gas chromatography–mass spectrometry (SPME–GC–MS) method is proposed for a rapid analysis of some frequently prescribed selective serotonin re-uptake inhibitors (SSRI)—venlafaxine, fluvoxamine, mirtazapine, fluoxetine, citalopram, and sertraline—in urine samples. The SPME-based method enables simultaneous determination of the target SSRI after simple in-situ derivatization of some of the target compounds. Calibration curves in water and in urine were validated and statistically compared. This revealed the absence of matrix effect and, in consequence, the possibility of quantifying SSRI in urine samples by external water calibration. Intra-day and inter-day precision was satisfactory for all the target compounds (relative standard deviation, RSD, <14%) and the detection limits achieved were <0.4 ng mL–1 urine. The time required for the SPME step and for GC analysis (30 min each) enables high throughput. The method was applied to real urine samples from different patients being treated with some of these pharmaceuticals. Some SSRI metabolites were also detected and tentatively identified.  相似文献   

5.
An ultra‐performance liquid chromatography/quadrupole time‐of‐flight mass spectrometry method was established to detect as many constituents in rat plasma as possible after oral administration of Radix polygoni multiflori (RPM) extract. A C18 column (150 × 2.0 mm, 4 µm) was adopted to separate the samples, and mass spectra were acquired in negative modes. The fingerprints of RPM extract were established, resulting in 39 components being detected. Among these compounds, 29 were identified by comparing the retention times and mass spectral data with those of reference standards and relevant references, and eight compounds were separated and detected in RPM for the first time. In vivo, 23 compounds were observed in dosed rat plasma, 16 of 23 compounds were indicated as prototype components of RPM, and seven compounds were predicted to be metabolites of RPM. A high‐speed and sensitive method was developed and was successfully utilized for screening and characterizing the ingredients and metabolites of RPM. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

6.
Testosterone metabolism revisited: discovery of new metabolites   总被引:1,自引:0,他引:1  
The metabolism of testosterone is revisited. Four previously unreported metabolites were detected in urine after hydrolysis with KOH using a liquid chromatography–tandem mass spectrometry method and precursor ion scan mode. The metabolites were characterized by a product ion scan obtained with accurate mass measurements. Androsta-4,6-dien-3,17-dione, androsta-1,4-dien-3,17-dione, 17-hydroxy-androsta-4,6-dien-3-one and 15-androsten-3,17-dione were proposed as feasible structures for these metabolites on the basis of the mass spectrometry data. The proposed structures were confirmed by analysis of synthetic reference compounds. Only 15-androsten-3,17-dione could not be confirmed, owing to the lack of a commercially available standard. That all four compounds are testosterone metabolites was confirmed by the qualitative analysis of several urine samples collected before and after administration of testosterone undecanoate. The metabolite androsta-1,4-dien-3,17-dione has a structure analogous to that of the exogenous anabolic steroid boldenone. Specific transitions for boldenone and its metabolite 17β-hydroxy-5β-androst-1-en-3-one were also monitored. Both compounds were also detected after KOH treatment, suggesting that this metabolic pathway is involved in the endogenous detection of boldenone previously reported by several authors.  相似文献   

7.
This work presents a new multi-residue analytical method based on solid phase extraction (SPE) with Oasis HLB sorbent, followed by gas chromatography tandem mass spectrometry (GC-MS/MS) for the simultaneous determination of a group of 10 acidic and neutral pharmaceuticals and related compounds in wastewaters. The typical derivation step was avoided, allowing the determination of acidic and neutral pollutants in a single analysis as well as providing a fast and easy method suitable for routine monitoring. Target pollutants include: anti-inflammatory drugs (ibuprofen, acetaminophen and diclofenac); an antiepileptic agent (carbamazepine); stimulants (caffeine and nicotine); an antiseptic (triclosan); a plasticizer (bisphenol A) and two of their more relevant metabolites (2,8-dichlorodibenzo-p-dioxin and 1,7-dimethylxanthine). Recoveries between 66 and 112% were achieved for all the target compounds (except for 2,8-dichlorodibenzo-p-dioxin). Good linearity was observed within the studied ranges (R2 > 0.993). Acceptable intra and inter-day precision was obtained, with relative standard deviation between 2 and 18%. The application of the optimized MS/MS mode allowed method detection limits in the range of 0.2-16 ng/L, with the exception of ibuprofen (120 ng/L). Finally, the methodology was successfully applied to the analysis of hospital effluent samples. All target analytes were detected at concentrations between 1 ng/L and 83215 μg/L. Even in the absence of derivatization, all the analytes showed good peak shape, except acetaminophen, which exhibited peak tailing. However, the method proved to be repetitive and reproducible, and the peak shape did not represent a problem for the reliable quantification of this compound. For most of the analytes studied, the detection limits achieved compare well against values reported in previously published methods.  相似文献   

8.
Adulterated products are continuously detected in society and cause problems. In this study, we developed and validated a method for determining synthetic sedative‐hypnotics and sleep inducers, including barbital, benzodiazepam, zolpidem, and first‐generation antihistamines, in adulterated products using Quadrupole‐Orbitrap mass spectrometry and ultrahigh performance liquid chromatography with tandem mass spectrometry. In Quadrupole‐Orbitrap mass spectrometry analysis, target compounds were confirmed using a combination of retention time, mass tolerance, mass accuracy, and fragment ions. For quantification, several validation parameters were employed using ultrahigh performance liquid chromatography with tandem mass spectrometry. The limit of detection and limit of quantitation was 0.05–53 and 0.17–177 ng/mL, respectively. The correlation coefficient for linearity was more than 0.995. The intra‐ and interassay accuracies were 86–110 and 84–111%, respectively. Their precision values were evaluated as within 4.0 (intraday) and 10.7% (interday). Mean recoveries of target compounds in adulterated products ranged from 85 to 116%. The relative standard deviation of stability was less than 10.7% at 4°C for 48 h. The 144 adulterated products obtained over 3 years (2014–2016) from online and in‐person vendors were tested using established methods. After rapidly screening with Quadrupole‐Orbitrap mass spectrometry, the detected samples were quantified using ultrahigh performance liquid chromatography with tandem mass spectrometry. Two of them were adulterated with phenobarbital.  相似文献   

9.
建立了高效液相色谱-串联质谱(HPLC-MS/MS)检测蔬菜水果中双甲脒(AMZ)及其降解或代谢产物单甲脒(DMPF)、2,4-二甲基苯基甲酰胺(DMF)和2,4-二甲基苯胺(DMA)的分析方法。样品经0.1 mol/L NaOH溶液稀释、正己烷-异丙醇(2:1,v/v)混合提取液提取,然后采用HPLC-MS/MS对目标物进行定性确证和定量分析。采用Phenomenex Kinetex C18色谱柱(100 mm×4.6 mm,2.6 μm)分离,以0.1%(v/v)甲酸水溶液和甲醇为流动相进行梯度洗脱,采用电喷雾电离(ESI)源、正离子监测模式进行检测。在1.0~200.0 μg/L范围内,4种目标化合物呈良好的线性关系,相关系数(r)大于0.99;方法的定量限为0.01~0.4 μg/kg。4种目标化合物在0.5、5.0和20.0 μg/kg 3个水平下的加标回收率为62.5%~105.0%,RSD为7.5%~17.6%。该法简便快捷,准确可靠,灵敏度高,定量限满足目前国内外残留限量要求。  相似文献   

10.
Valeriana jatamansi Jones is an important medicinal plant and its quality is closely related to its region of origin. In the current study, we utilized a flexible and powerful strategy for comprehensive evaluation of the quality diversity for 15 regions in China. The method was based on a hybrid linear ion trap‐Orbitrap mass spectrometry platform. For structure characterization, fragmentation patterns were detected by analyzing a series of standard compounds using data dependent multistage mass spectrometry acquisition. A fragment ion database for valepotriates was established, and the acquired data were high throughput filtered by fragment ion search for compound identification. For quantitative purposes, we normalized the mass spectrometry data of 15 samples using SIEVE 2.0 and the differences in composition were analyzed using principal component analysis combined with hierarchical clustering analysis. The results identified a total of 92 compounds from Valeriana jatamansi Jones. Samples from Dali, Kunming, and Baoshan have better qualities and concentrations of the main active constituents. To verify our strategy, we compared the valtrate, acevaltrate, and baldrinal contents using high‐performance liquid chromatography with diode array detector. We developed and validated a comprehensive qualitative and quantitative analytical method to achieve quality control of Valeriana jatamansi Jones.  相似文献   

11.
张秀尧  蔡欣欣 《色谱》2014,32(7):693-701
建立了超高效液相色谱-三重四极杆质谱快速测定牛奶中53种β-内酰胺类抗生素及其代谢产物残留的检测方法。牛奶样品经等量乙腈沉淀去蛋白、超滤后,以0.1%(v/v,下同)甲酸水溶液和0.1%甲酸乙腈溶液作为流动相进行梯度洗脱,在ACQUITY BEH C18色谱柱上实现分离,一次进样分析仅需10 min,正离子电喷雾多反应监测(MRM)模式检测,基体工作曲线内标法定量。线性范围从方法的定量限至200μg/kg,相关系数均优于0.991 1,平均加标回收率在71%~121%之间,相对标准偏差为1.7%~19%(n=6)。方法简单、快速,每人每天可处理50多份样品,检出限能够满足我国和欧盟对兽药残留的最高限量要求,适合于牛奶样品中53种β-内酰胺类抗生素及其代谢产物的快速筛查和定量测定。  相似文献   

12.
A novel magnetic metal‐organic framework composite was prepared by a self‐assembly approach. The material properties were characterized by Fourier‐transform infrared spectroscopy, vibrating sample magnetometry, thermogravimetry and differential thermogravimetric analysis, and X‐photoelectron spectroscopy. Then, the as‐prepared material was used as an adsorbent and indicated great enrichment ability toward glyphosate, glufosinate, bialaphos, and their main metabolites aminomethylphosphonic acid and 3‐methylphosphinicopropionic acid. Based on this, an efficient magnetic solid‐phase extraction method combined with ultra high performance liquid chromatography with high‐resolution mass spectrometry for the pretreatment and determination of five target compounds in environmental waters was established. Parameters that could impact on the adsorption performance had been studied in detail. The proposed method was successfully applied for the simultaneous determination of glyphosate, glufosinate, bialaphos, and their main metabolites aminomethylphosphonic acid and 3‐methylphosphinicopropionic acid in environmental water with recoveries in range of 86.2–104.6% with relative standard deviations less than 10%. Desired linearity was achieved varying from 1 to 100 μg/L for five target analytes, respectively. The limits of detection were between 0.01 and 0.03 μg/L.  相似文献   

13.
A reliable quantification by LC-ESI-MS/MS as the most suitable analytical method for polar substances in the aquatic environment is usually hampered by matrix effects from co-eluting compounds, which are unavoidably present in environmental samples. The standard addition method (SAM) is the most appropriate method to compensate matrix effects. However, when performed manually, this method is too labour- and time-intensive for routine analysis. In the present work, a fully automated SAM using a multi-purpose sample manager “Open Architecture UPLC®-MS/MS” (ultra-performance liquid chromatography tandem mass spectrometry) was developed for the sensitive and reliable determination of 29 polar pesticide metabolites in environmental samples. A four-point SAM was conducted parallel to direct-injection UPLC-ESI-MS/MS determination that was followed by a work flow to calculate the analyte concentrations including monitoring of required quality criteria. Several parameters regarding the SAM, chromatography and mass spectrometry conditions were optimised in order to obtain a fast as well as reliable analytical method. The matrix effects were examined by comparison of the SAM with an external calibration method. The accuracy of the SAM was investigated by recovery tests in samples of different catchment areas. The method detection limit was estimated to be between 1 and 10 ng/L for all metabolites by direct injection of a 10-μL sample. The relative standard deviation values were between 2 and 10 % at the end of calibration range (30 ng/L). About 200 samples from different water bodies were examined with this method in the Rhine and Ruhr region of North Rhine-Westphalia (Germany). Approximately 94 % of the analysed samples contained measurable amounts of metabolites. For most metabolites, low concentrations ≤0.10 μg/L were determined. Only for three metabolites were the concentrations in ground water significantly higher (up to 20 μg/L). In none of the examined drinking water samples were the health-related indication values (between 1 and 3 μg/L) for non-relevant metabolites exceeded.  相似文献   

14.
A simple and rapid liquid chromatography–mass spectrometry (LC‐MS) method was developed and validated for analysis of ginsenoside Rb1, Rb2, Rc, Rd, Re, Rf, Rg1, icariin and epimedin A, B, C in rat target tissues (spinal cord, brain, muscle and sciatic nerve) after intravenous administration of Jiweiling freeze‐dried powder using genistein as an internal standard (IS). The tissue samples were treated by protein precipitation with methanol prior to HPLC and chromatographic separation was performed on a C18 column utilizing a gradient elution program with acetonitrile and 0.1% formic acid aqueous. Electrospray ionization (ESI) source was employed and the 11 analytes and IS were detected by multiple reaction monitoring (MRM) scanning under the negative ionization mode. Higher sensitivity was achieved and the optimized mass transition ion‐pairs (m/z) for quantitation were selected. The calibration curves were linear over the investigated concentration ranges with correlation coefficients higher than 0.995. The intra‐ and inter‐day RSDs were all less than 10% with the relative error (RE) within ±9.3%. The mean extraction recoveries for all compounds were between 93.3 and 106%. The proposed method was successfully applied to investigate the target tissue distribution of the 11 compounds in rat after intravenous administration of Jiweiling freeze‐dried powder. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

15.
欧洲鸡蛋污染事件爆发后,氟虫腈及其代谢物氟甲腈、氟虫腈砜和氟虫腈亚砜残留受到人们较多关注.该研究通过优化前处理方法和色谱条件,建立了畜禽肝脏中氟虫腈及其代谢物的高效液相色谱-串联质谱测定分析方法.样品经10 mL乙腈提取,150 mg PSA、100 mg C18填料净化后,将提取液直接进样分析,以乙腈和水为流动相进行...  相似文献   

16.
A liquid chromatography/time-of-flight mass spectrometry (LC-TOF-MS) method for targeted toxicological screening in human postmortem blood samples from forensic autopsy cases has been developed, validated and compared with a previously used method using gas chromatography with nitrogen–phosphorus detection (GC-NPD). Separation was achieved within 12 min by high-resolution gradient chromatography. Ions were generated in positive and negative electrospray ionization mode and were detected in 2-GHz single mass spectrometry mode, m/z range 50–1,000. Before injection, 0.25 g blood was prepared by protein precipitation with 500 μL of a mixture of acetonitrile and ethanol containing deuterated internal standards. An in-house database comprising 240 drugs and metabolites was built by analysing solutions from certified standards or other documented reference material available. Identification was based on scoring of retention time, accurate mass measurement and isotopic pattern. Validation was performed on spiked blood samples and authentic postmortem blood samples. The thresholds defined as minimum required performance levels were for most compounds in the range from 0.01 to 0.10 μg/g. Typically, a mass error of less than 2 ppm and a precision of area measurements of less than 5 % coefficient of variation were achieved. Positive identification was confirmed at concentrations up to 500 μg/g. Most compounds were determined in positive ionization mode, but for a limited number of compounds (fewer than 4 %) negative ionization was needed and a few early-eluted compounds could not be identified owing to substantial influence of interferences from the matrix and were thus not included in the screening. A robust and valid toxicological screening by LC-TOF-MS for postmortem blood samples, covering 50 % more compounds, and with higher precision and sensitivity than the previously used screening by GC-NPD was achieved.  相似文献   

17.
A comprehensive method was developed for the simultaneous trace analysis of ten hormone antagonist pharmaceuticals (raloxifene, exemestane, letrozole, anastrozole, mifepristone, finastride, tamoxifen, N-desmethyltamoxifen, clomiphene, and toremifene) in municipal sewage and hospital wastewater samples. The target compounds were firstly extracted using an Oasis HLB cartridge, followed by purification by an aminopropyl cartridge, and were then analyzed by liquid chromatography electrospray ionization tandem mass spectrometry in positive ion mode. The recoveries for the analytes based on internal standard calibration in different test matrices ranged from 67.6 to 118.6% (with the exception of mifepristone in clinical wastewater samples), with relative standard deviations less than 20%. The method quantification limits of the ten pharmaceuticals were in the range 0.10–2.0 ng/L. Excluding exemestane and N-desmethyltamoxifen, eight drugs were detected at 0.20–195.0 ng/L in hospital wastewater and municipal wastewater samples from Beijing.  相似文献   

18.
A novel method for the analysis of endogenous lipids and related compounds was developed employing hydrophilic interaction liquid chromatography with electrospray ionization tandem mass spectrometry. A hydrophilic interaction liquid chromatography with carbamoyl stationary phase achieved clear separation of phosphatidylcholine, lysophosphatidylcholine, sphingomyelin, ceramide, and mono‐hexsosyl ceramide groups with good peak area repeatability (RSD% < 10) and linearity (R2 > 0.99). The established method was applied to human plasma assays and a total of 117 endogenous lipids were successfully detected and reproducibly identified. In addition, we investigated the simultaneous detection of small polar metabolites such as amino and organic acids co‐existing in the same biological samples processed in a single analytical run with lipids. Our results show that hydrophilic interaction liquid chromatography is a useful tool for human plasma lipidome analysis and offers more comprehensive metabolome coverage.  相似文献   

19.
A high-performance liquid chromatographic method with fluorescence detection has been developed to determine the urinary polycyclic aromatic hydrocarbon metabolites 2-hydroxynaphthalene, 2-hydroxyfluorene, 9-hydroxyphenanthrene, 1-hydroxypyrene and 3-hydroxybenz[a]pyrene. Solid phase extraction (SPE) was used to clean up the samples, and washing with 30% methanol was found to be the best way to remove interferences in the matrix. The method detection limits ranged from 0.044 μg/L for 1-hydroxypyrene to 1.615 μg/L for 3-hydroxybenz[a]pyrene, and the recoveries ranged between 40% for 3-hydroxybenz[a]pyrene and 99% for 2-hydroxynaphthalene. The within-day relative standard deviation was lowest for 2-hydroxynaphthalene at 0.67% and went up to 2.42% for 3-hydroxybenz[a]pyrene, and the between-day relative standard deviation ranged from 3.84% for 9-hydroxyphenanthrene to 10.42% for 2-hydroxyfluorene. The correlation coefficients were between 0.9962 and 0.9998. The developed method was successfully used to analyze samples from student volunteers in a high school.  相似文献   

20.
l ‐Isocorypalmine, an active alkaloid compound isolated from Rhizoma Corydalis yanhusuo, has been reported to possess biological activity for treating cocaine use disorder. A high‐performance liquid chromatography coupled to Fourier transform ion cyclotron resonance mass spectrometry method was established for identification of the metabolites of l ‐isocorypalmine in urine, plasma and feces samples of rats after a single intragastric gavage of l ‐isocorypalmine at a dose of 15 mg/kg. As a result, a total of 21 metabolites (six phase ? metabolites and fifteen phase II metabolites) were detected and tentatively identified by mass spectrometry and fragment ions from tandem mass spectrometry spectra. All metabolites were present in the urine samples, nine metabolites were found in the plasma samples and three metabolites were found in the feces samples. Results indicated that metabolic pathways of l ‐isocorypalmine included oxidation, dehydrogenation, demethylation, sulfate conjugation, and glucuronide conjugation. In addition, glucuronidation was the major metabolic reaction. Results of this investigation could provide significant experimental basis for efficacy, safety and action mechanism of l ‐isocorypalmine, which will be advantageous to new drug development for treating cocaine addiction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏