This work explores slice profile effects in 2D slice-selective gradient-echo MRI of hyperpolarized nuclei. Two different sequences were investigated: a Spoiled Gradient Echo sequence with variable flip angle (SPGR-VFA) and a balanced Steady-State Free Precession (SSFP) sequence. It is shown that in SPGR-VFA the distribution of flip angles across the slice present in any realistically shaped radiofrequency (RF) pulse leads to large excess signal from the slice edges in later RF views, which results in an undesired non-constant total transverse magnetization, potentially exceeding the initial value by almost 300% for the last RF pulse. A method to reduce this unwanted effect is demonstrated, based on dynamic scaling of the slice selection gradient. SSFP sequences with small to moderate flip angles (<40°) are also shown to preserve the slice profile better than the most commonly used SPGR sequence with constant flip angle (SPGR-CFA). For higher flip angles, the slice profile in SSFP evolves in a manner similar to SPGR-CFA, with depletion of polarization in the center of the slice.  相似文献   

2.
优化重聚脉冲提高梯度场核磁共振信号强度   总被引:1,自引:0,他引:1       下载免费PDF全文
李新  肖立志  刘化冰  张宗富  郭葆鑫  于慧俊  宗芳荣 《物理学报》2013,62(14):147602-147602
缩短射频脉冲宽度, 有助于解决脉冲电力消耗大、样品吸收率高、信噪比低等极端条件核磁共振探测的关键问题. 本文首先分析射频脉冲角度对核磁共振自旋回波信号强度的影响机理, 基于Bloch方程推导了回波信号幅度与扳转角、重聚角的关系. 在特制核磁共振分析仪上采用变脉冲角度技术, 分别在均匀磁场和梯度磁场条件下实现对扳转角和重聚角与回波信号强度关系的数值模拟和实验测量. 结果表明, 梯度场中, 扳转角为90°、重聚角为140°的射频脉冲组合获得最大首波信号强度, 比180°脉冲对应的回波幅值提高13%, 能耗降低至78%. 选用该重聚角(140°) 优化设计饱和恢复脉冲序列探测流体的纵向弛豫时间T1特性, 准确获得 T1分布.该结果对于低电力供应、且对信噪比有较高要求的核磁共振测量, 如随钻核磁共振测井和在线核磁共振快速检测等, 具有重要意义. 关键词: 核磁共振 信号强度 重聚脉冲角度 Bloch方程  相似文献   

3.
Ultrashort TE (UTE) sequences allow direct visualization of tissues with very short T2 relaxation times, such as tendons, ligaments, menisci, and cortical bone. In this work, theoretical calculations, simulations, and phantom studies, as well as in vivo imaging were performed to maximize signal-to-noise ratio (SNR) for slice selective RF excitation for 2D UTE sequences. The theoretical calculations and simulations were based on the Bloch equations, which lead to analytic expressions for the optimal RF pulse duration and amplitude to maximize magnetic resonance signal in the presence of rapid transverse relaxation. In steady state, it was found that the maximum signal amplitude was not obtained at the classical Ernst angle, but at an either lower or higher flip angle, depending on whether the RF pulse duration or amplitude was varied, respectively.  相似文献   

4.
The influence of flip angle and flow velocity on the signal intensity achieved when imaging a hyperpolarized substance with a spoiled gradient echo sequence was investigated. The study was performed both theoretically and experimentally using hyperpolarized xenon dissolved in ethanol. Analytical expressions regarding the optimal flip angle with respect to signal and the corresponding signal level are presented and comparisons with thermally polarized substances are made. Both experimentally and theoretically, the optimal flip angle was found to increase with increasing flow velocity. Numerical calculations showed that the velocity dependence of the signal differs between the cases of hyperpolarized and thermally polarized substances.  相似文献   

5.
A study was undertaken to assess the use of excitation flip angles greater than 90° for T1 weighted spin-echo (SE) imaging with a single 180° refocusing pulse and short TR values. Theoretical predictions of signal intensity for SE images with excitation pulse angles of 90–180° were calculated based on the Bloch equations and then measured experimentally from MR images of MnCl2 phantoms of various concentrations. Liver signal-to-noise ratios (SNR) and liver-spleen contrast-to-noise ratios (CNR) were measured from breathhold MR images of the upper abdomen in 16 patients using 90 and 110° excitation flip angles. The theoretical predictions showed significant improvements in SNR with excitation flip angles >90°, which were more pronounced at small TR values. The phantom studies showed reasonably good agreement with the theoretical predictions in correlating the excitation pulse angle with signal intensity. In the human imaging studies, the 110° excitation pulse angle resulted in a 7.4% (p < .01) increase in liver SNR and an 8.2% (p = .2) increase in liver-spleen CNR compared to the 90° pulse angle at TR = 275 ms. Increased signal intensity resulting from the use of large flip angle excitation pulses with a single echo SE pulse sequence was predicted and confirmed experimentally in phantoms and humans.  相似文献   

6.
We present a method for rapid measurement of T1 relaxation times using gradient refocused images at limited flip angles and short repetition times. This "variable nutation" techniques was investigated using a T1 phantom. There was a high correlation between measurements obtained with the variable nutation and partial saturation techniques. The ability of this method to create calculated T1 images is also demonstrated. We conclude that the variable nutation method may allow measurement of T1 relaxation times with a significant reduction in acquisition time compared to partial saturation techniques.  相似文献   

7.
Significant artifacts arise in T(1rho)-weighted imaging when nutation angles suffer small deviations from their expected values. These artifacts vary with spin-locking time and amplitude, severely limiting attempts to perform quantitative imaging or measurement of T(1rho) relaxation times. A theoretical model explaining the origin of these artifacts is presented in the context of a T(1rho)-prepared fast spin-echo imaging sequence. Experimentally obtained artifacts are compared to those predicted by theory and related to B(1) inhomogeneity. Finally, a "self-compensating" spin-locking preparatory pulse cluster is presented, in which the second half of the spin-locking pulse is phase-shifted by 180 degrees. Use of this pulse sequence maintains relatively uniform signal intensity despite large variations in flip angle, greatly reducing artifacts in T(1rho)-weighted imaging.  相似文献   

8.
A novel method for mapping the longitudinal relaxation time in a clinically acceptable time is developed based on a recent proposal [J.-J. Hsu, I.J. Lowe, Spin-lattice relaxation and a fast T1-map acquisition method in MRI with transient-state magnetization, J. Magn. Reson. 169 (2004) 270-278] and the speed of the spiral pulse sequence. The method acquires multiple curve-fitting samples with one RF pulse train. It does not require RF pulses of specific flip angles (e.g., 90 degrees or 180 degrees ), nor are the long recovery waiting time and the measurement of the magnetization at thermal equilibrium needed. Given the value of the flip angle, the curve fitting is semi-logarithmic and not computationally intensive. On a heterogeneous phantom, the average percentage difference between measurements of the present method and those of an inversion-recovery method is below 2.7%. In mapping the human brain, the present method, for example, can obtain four curve-fitting samples for five 128 x 128 slices in less than 3.2s and the results are in agreement with other studies in the literature.  相似文献   

9.
Hyperpolarized 13C offers high signal-to-noise ratios for imaging metabolic activity in vivo, but care must be taken when designing pulse sequences because the magnetization cannot be recovered once it has decayed. It has a short lifetime, on the order of minutes, and gets used up by each RF excitation. In this paper, we present a new dynamic chemical-shift imaging method that uses specialized RF pulses designed to maintain most of the hyperpolarized substrate while providing adequate SNR for the metabolic products. These are multiband, variable flip angle, spectral-spatial RF pulses that use spectral selectivity to minimally excite the injected prepolarized 13C-pyruvate substrate. The metabolic products of lactate and alanine are excited with a larger flip angle to increase SNR. This excitation was followed by an RF amplitude insensitive double spin-echo and an echo-planar flyback spectral-spatial readout gradient. In vivo results in rats and mice are presented showing improvements over constant flip angle RF pulses. The metabolic products are observable for a longer window because the low pyruvate flip angle preserves magnetization, allowing for improved observation of spatially varying metabolic reactions.  相似文献   

10.
The effects of varying the inversion or excitation RF pulse flip angles on image contrast and imaging time have been investigated in IR imaging theoretically, with phantoms and with normal volunteers. Signal intensity in an IR pulse sequence as a function of excitation, inversion and refocusing pulse flip angles was calculated from the solution to the Bloch equations and was utilized to determine the contrast behavior of a lesion/liver model. Theoretical and experimental results were consistent with each other. With the TI chosen to suppress the fat signal, optimization of the excitation pulse flip angle results in an increase in lesion/liver contrast or allows reduction in imaging time which, in turn, can be traded for an increased number of averages. This, in normal volunteers, improved spleen/liver contrast-to-noise ratio (9.0 vs. 5.7, n = 8, p less than 0.01) and suppressed respiratory ghosts by 33% (p less than 0.01). Reducing or increasing the inversion pulse from 180 degrees results in shorter TI needed to null the signal from the tissue of interest. Although this decreases the contrast-to-noise ratio, it can substantially increase the number of sections which can be imaged per given TR in conventional IR imaging or during breathold in the snapshot IR (turboFLASH) technique. Thus, the optimization of RF pulses is useful in obtaining faster IR images, increasing the contrast and/or increasing the number of imaging planes.  相似文献   

11.
We present a new method to determine in vivo the temporal evolution of intrapulmonary oxygen concentrations by functional lung imaging with hyperpolarized (3)Helium ((3)He-->). Single-breath, single-bolus visualization of (3)He--> administered to the airspaces is used to analyze nuclear spin relaxation caused by the local oxygen partial pressure p(O(2))(t). We model the dynamics of hyperpolarization in the lung by rate equations. Based hereupon, a double acquisition technique is presented to separate depolarization by RF pulses and oxygen induced relaxation. It permits the determination of p(O(2)) with a high accuracy of up to 3% with simultaneous flip angle calibration using no additional input parameters. The time course of p(O(2)) during short periods of breathholding is found to be linear in a pig as well as in a human volunteer. We also measured the wall relaxation time in the lung and deduced a lower limit of 4.3 min.  相似文献   

12.
In this paper, signals originating from a pure specific coherence of intermolecular three-spin orders were separated and characterized experimentally in highly polarized two-component spin systems. A modified CRAZED sequence with selective radio-frequency excitation was designed to separate the small signals from the strong conventional single-spin single-quantum signals. General theoretical expressions of the pulse sequence with arbitrary flip angle pulses were derived using dipolar field treatment. The expressions were used to predict the relaxation and diffusion properties and optimal experimental parameters such as flip angles. For the first time, relaxation and diffusion properties of pure intermolecular single-quantum, double-quantum, and triple-quantum coherences of three-spin orders were characterized and analyzed in one-dimensional experiments. All experimental observations are in excellent agreement with the theoretical predictions. The theoretical results show that the quantum-mechanical treatment leads to exactly the same predictions as the dipolar field treatment. The quantitative study of intermolecular multiple-quantum coherences of three-spin orders presented herein provides a better understanding of their mechanisms.  相似文献   

13.
In the classic spectroscopic steady-state free precession (SSFP) experiment, a regular sequence of phase-coherent radio frequency pulses is applied with constant flip angle and a repetition time shorter than the NMR relaxation times of the sample. As the steady state is reached, an NMR signal appears between pulses that consists of two distinct components: a free induction signal following the RF pulses and decaying during the repetition interval and a spin-echo-like signal forming at its end prior to the subsequent RF pulse. Both signals may be exploited for NMR imaging if the gradient schemes fulfill the phase coherence requirements of SSFP. This article describes two Fourier acquired steady-state sequences dubbed FAST and CE-FAST, which may be used for the rapid acquisition of NMR images from the SSFP signals.  相似文献   

14.
A fundamental problem in Fourier transform NMR spectroscopy is the calculation of observed resonance amplitudes for a repetitively pulsed sample, as first analyzed by Ernst and Anderson in 1966. Applications include determination of spin-lattice relaxation times (T(1)'s) by progressive saturation and correction for partial saturation in order to determine the concentrations of the chemical constituents of a spectrum. Accordingly, the Ernst and Anderson formalism has been used in innumerable studies of chemical and, more recently, physiological systems. However, that formalism implicitly assumes that no chemical exchange occurs. Here, we present an analysis of N sites in an arbitrary chemical exchange network, explicitly focusing on the intermediate exchange rate regime in which the spin-lattice relaxation rates and the chemical exchange rates are comparable in magnitude. As a special case of particular importance, detailed results are provided for a system with three sites undergoing mutual exchange. Specific properties of the N-site network are then detailed. We find that (i) the Ernst and Anderson analysis describing the response of a system to repetitive pulsing is inapplicable to systems with chemical exchange and can result in large errors in T(1) and concentration measurements; (ii) T(1)'s for systems with arbitrary exchange networks may still be correctly determined from a one-pulse experiment using the Ernst formula, provided that a short interpulse delay time and a large flip angle are used; (iii) chemical concentrations for exchanging systems may be correctly determined from a one-pulse experiment either by using a short interpulse delay time with a large flip angle, as for measuring T(1)'s, and correcting for partial saturation by use of the Ernst formula, or directly by using a long interpulse delay time to avoid saturation; (iv) there is a significant signal-to-noise penalty for performing one-pulse experiments under conditions which permit accurate measurements of T(1)'s and chemical concentrations. The present results are analogous to but are much more general than those that we have previously derived for systems with two exchanging sites. These considerations have implications for the design and interpretation of one-pulse experiments for all systems exhibiting chemical exchange in the intermediate exchange regime, including virtually all physiologic samples.  相似文献   

15.
The Carr-Purcell pulse sequence, with low refocusing flip angle, produces echoes midway between refocusing pulses that decay to a minimum value dependent on T(2). When the refocusing flip angle was π/2 (CP(90)) and τ>T(2), the signal after the minimum value, increased to reach a steady-state free precession regime (SSFP), composed of a free induction decay signal after each pulse and an echo, before the next pulse. When τ相似文献   

16.
To explain the signal behavior in 2D-TrueFISP imaging, a slice excitation profile should be considered that describes a variation of effective flip angles and magnetization phases after excitation. These parameters can be incorporated into steady-state equations to predict the final signal within a pixel. The use of steady-state equations assumes that excitation occurs instantaneously, although in reality this is a nonlinear process. In addition, often the flip angle variation within the slice excitation profile is solely considered when using steady-state equations, while TrueFISP is especially known for its sensitivity to phase variations. The purpose of this study was therefore to evaluate the precision of steady-state equations in calculating signal intensities in 2D TrueFISP imaging. To that end, steady-state slice profiles and corresponding signal intensities were calculated as function of flip angle, RF phase advance and pulse shape. More complex Bloch simulations were considered as a gold standard, which described every excitation within the sequence until steady state was reached. They were used to analyze two different methods based on steady-state equations. In addition, measurements on phantoms were done with corresponding imaging parameters. Although the Bloch simulations described the steady-state slice profile formation better than methods based on steady-state equations, the latter performed well in predicting the steady-state signal resulting from it. In certain cases the phase variation within the slice excitation profile did not even have to be taken into account.  相似文献   

17.
Na+with both residual quadrupolar coupling and biexponential relaxation contributes to the signal acquired from DQF-4, while only Na+with residual quadrupolar coupling contributes to the signal acquired with the Jeener–Broekaert sequence. Since RF phases and flip angles for DQF-4 and Jeener-Broekaert sequences are identical, these different types of signals can be generated simultaneously. A phase-cycling scheme is developed to differentiate the signals corresponding to residual quadrupolar coupling and biexponential relaxation after the signals are acquired by use of the same RF sequences. This technique can maximize the attainable information from Na+in biological tissues in a given acquisition time.  相似文献   

18.
本文探讨1.5 T磁共振化学交换饱和转移(Chemical Exchange Saturation Transfer,CEST)成像的影响因素.通过试管模型和临床病例,采用GE Signa HDe 1.5 T磁共振成像(Magnetic Resonance Imaging,MRI)扫描仪分别进行不同矩阵、激励次数、翻转角、磁化传递翻转角的CEST成像对比分析,以及不同激励次数、磁化传递翻转角的Z谱分析,并从成像组织、成像设备、成像技术等方面对原始图信号、酰胺质子转移(Amide Proton Transfer,APT)信号及Z谱进行分析研究.实验结果表明1.5 T MRI扫描仪的CEST图像信噪比相对较低,且磁场稳定性及均匀度影响了CEST成像的效果.在其他参数不变的情况下,降低采集矩阵和增加激励次数与翻转角可以增加原始图像信噪比.磁化传递翻转角为105°时,CEST成像效果最好.激励次数为2、磁化传递翻转角为105°时,所得数据符合组织Z谱情况.模型Z谱在磁化传递频率为-294~-194 Hz范围可显示30%谷氨酸(Glu)、碘剂(I320)、纯水(H2O)、肌酸(Cr)的信号差异,与H2O差异最大处在-244~-214 Hz.原始图像信号30% I320明显高于Glu、H2O、Cr,Cr略低于Glu,APT图Cr略低于Glu.25例脑肿瘤的APT图呈高信号、12例脑梗塞的APT图呈低信号,CEST原始图像均可区分病变区域.有12例因采集时间、患者配合情况、环境及室温等影响导致CEST成像的失败.由此得出1.5 T场强下,CEST技术受到成像组织、设备、技术等因素的影响,需要进行多方面优化.在保证磁场稳定性及均匀度的情况下,优化参数的CEST成像和Z谱成像可以区分代谢物及其浓度.  相似文献   

19.
Relaxation effects in the quantification of fat using gradient echo imaging   总被引:4,自引:0,他引:4  
Quantification of fat has been investigated using images acquired from multiple gradient echoes. The evolution of the signal with echo time and flip angle was measured in phantoms of known fat and water composition and in 21 research subjects with fatty liver. Data were compared to different models of the signal equation, in which each model makes different assumptions about the T1 and/or T2* relaxation effects. A range of T1, T2*, fat fraction and number of echoes was investigated to cover situations of relevance to clinical imaging. Results indicate that quantification is most accurate at low flip angles (to minimize T1 effects) with a small number of echoes (to minimize spectral broadening effects). At short echo times, the spectral broadening effects manifest as a short apparent T2 for the fat component.  相似文献   

20.

Purpose

To include the flip angle distribution caused by the slice profile into the model used for describing the relaxation curves observed in inversion recovery Look–Locker FLASH T1 mapping for a more accurate determination of the relaxation parameters.

Materials and methods

For each inversion time, the flip angle dependent signal of the mono-exponential relaxation model is integrated across the slice profile. The resulting Consideration of Slice Profiles (CSP) relaxation curves are compared to the mono-exponential signal model in numerical simulations as well as in phantom and in-vivo experiments.

Results

All measured relaxation curves showed systematic deviations from a mono-exponential curve increasing with flip angle and T1 but decreasing with repetition time. Additionally, the accuracy of T1 was found to be largely dependent on the temporal coverage of the relaxation curve. All these systematic errors were largely reduced by the CSP model.

Conclusion

The proposed CSP model represents a useful extension of the conventionally used mono-exponential relaxation model. Despite inherent model inaccuracies, the mono-exponential model was found to be sufficient for many T1 mapping situations. However, if only a poor temporal coverage of the relaxation process is achievable or a very precise modeling of the relaxation course is needed as in model-based techniques, the mono-exponential model leads to systematic errors and the CSP model should be used instead.  相似文献   